The effect of implementing a modified early warning scoring (MEWS) system on the adequacy of vital sign documentation


Autoria(s): Hammond, Naomi E.; Spooner, Amy J.; Barnett, Adrian G.; Corley, Amanda; Brown, Peter; Fraser, John F.
Data(s)

2012

Resumo

Introduction and objectives Early recognition of deteriorating patients results in better patient outcomes. Modified early warning scores (MEWS) attempt to identify deteriorating patients early so timely interventions can occur thus reducing serious adverse events. We compared frequencies of vital sign recording 24 h post-ICU discharge and 24 h preceding unplanned ICU admission before and after a new observation chart using MEWS and an associated educational programme was implemented into an Australian Tertiary referral hospital in Brisbane. Design Prospective before-and-after intervention study, using a convenience sample of ICU patients who have been discharged to the hospital wards, and in patients with an unplanned ICU admission, during November 2009 (before implementation; n = 69) and February 2010 (after implementation; n = 70). Main outcome measures Any change in a full set or individual vital sign frequency before-and-after the new MEWS observation chart and associated education programme was implemented. A full set of vital signs included Blood pressure (BP), heart rate (HR), temperature (T°), oxygen saturation (SaO2) respiratory rate (RR) and urine output (UO). Results After the MEWS observation chart implementation, we identified a statistically significant increase (210%) in overall frequency of full vital sign set documentation during the first 24 h post-ICU discharge (95% CI 148, 288%, p value <0.001). Frequency of all individual vital sign recordings increased after the MEWS observation chart was implemented. In particular, T° recordings increased by 26% (95% CI 8, 46%, p value = 0.003). An increased frequency of full vital sign set recordings for unplanned ICU admissions were found (44%, 95% CI 2, 102%, p value = 0.035). The only statistically significant improvement in individual vital sign recordings was urine output, demonstrating a 27% increase (95% CI 3, 57%, p value = 0.029). Conclusions The implementation of a new MEWS observation chart plus a supporting educational programme was associated with statistically significant increases in frequency of combined and individual vital sign set recordings during the first 24 h post-ICU discharge. There were no significant changes to frequency of individual vital sign recordings in unplanned admissions to ICU after the MEWS observation chart was implemented, except for urine output. Overall increases in the frequency of full vital sign sets were seen.

Identificador

http://eprints.qut.edu.au/53382/

Publicador

Elsevier

Relação

DOI:10.1016/j.aucc.2012.05.001

Hammond, Naomi E., Spooner, Amy J., Barnett, Adrian G., Corley, Amanda, Brown, Peter, & Fraser, John F. (2012) The effect of implementing a modified early warning scoring (MEWS) system on the adequacy of vital sign documentation. Australian Critical Care.

Fonte

Faculty of Health; Institute of Health and Biomedical Innovation; School of Public Health & Social Work

Palavras-Chave #110310 Intensive Care #Intensive care #Modified early warning scores (MEWS); Intensive care; Vital signs; Deteriorating patients; Medical emergency teams (MET)
Tipo

Journal Article