47 resultados para volumetry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

As lipofilling of the female breast is becoming more popular in plastic surgery, the use of MRI to assess breast volume has been employed to control postoperative results. Therefore, we sought to evaluate the accuracy of magnetic resonance imaging (MRI)-based breast volumetry software tools by comparing the measurements of silicone implant augmented breasts with the actual implant volume specified by the manufacturer. MRI-based volume analysis was performed in eight bilaterally augmented patients (46 ± 9 years) with three different software programs (Brainlab© I plan 2.6 neuronavigation software; mass analysis, version 5.3, Medis©; and OsiriX© v.3.0.2. 32-bit). The implant volumes analysed by the BrainLab© software had a mean deviation of 2.2 ± 1.7% (r?=?0.99) relative to the implanted prosthesis. OsiriX© software analysis resulted in a mean deviation of 2.8 ± 3.0% (r?=?0.99) and the Medis© software had a mean deviation of 3.1 ± 3.0% (r?=?0.99). Overall, the volumes of all analysed breast implants correlated very well with the real implant volumes. Processing time was 10 min per breast with each system and 30 s (OsiriX©) to 5 min (BrainLab© and Medis©) per silicone implant. MRI-based volumetry is a powerful tool to calculate both native breast and silicone implant volume in situ. All software solutions performed well and the measurements were close to the actual implant sizes. The use of MRI breast volumetry may be helpful in: (1) planning reconstructive and aesthetic surgery of asymmetric breasts, (2) calculating implant size in patients with missing documentation of a previously implanted device and (3) assessing post-operative results objectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Methods Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). Results A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CVW. Conclusions Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Cognitive complaints, such as poor concentration and memory deficits, are frequent after whiplash injury and play an important role in disability. The origin of these complaints is discussed controversially. Some authors postulate brain lesions as a consequence of whiplash injuries. Potential diffuse axonal injury (DAI) with subsequent atrophy of the brain and ventricular expansion is of particular interest as focal brain lesions have not been documented so far in whiplash injury. OBJECTIVE: To investigate whether traumatic brain injury can be identified using a magnetic resonance (MR)-based quantitative analysis of normalized ventricle-brain ratios (VBR) in chronic whiplash patients with subjective cognitive impairment that cannot be objectively confirmed by neuropsychological testing. MATERIALS AND METHODS: MR examination was performed in 21 patients with whiplash injury and symptom persistence for 9 months on average and in 18 matched healthy controls. Conventional MR imaging (MRI) was used to assess the volumes of grey and white matter and of ventricles. The normalized VBR was calculated. RESULTS: The values of normalized VBR did not differ in whiplash patients when compared with that in healthy controls (F = 0.216, P = 0.645). CONCLUSIONS: This study does not support loss of brain tissue following whiplash injury as measured by VBR. On this basis, traumatic brain injury with subsequent DAI does not seem to be the underlying mechanism for persistent concentration and memory deficits that are subjectively reported but not objectively verifiable as neuropsychological deficits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous MRI-volumetric studies in schizophrenic psychoses have demonstrated more or less pronounced volume reductions of the hippocampus in patients. Correspondingly, neuropathological examinations on the brains of schizophrenics showed diverse structural changes of the hippocampus. Employing a high-resolution 3D-MPRAGE sequence, we found volume reductions in most hippocampal subregions of schizophrenic patients, which, however, did not reach significant levels. An analysis of co-registered diffusion tensor imaging (DTI) data revealed significant alterations of the inter-voxel coherences in single hippocampal subdivisions of these patients, supporting the assumption of characteristic microstructural tissue changes relevant for the pathogenesis of schizophrenic psychoses. Our results argue for the usage of additional MRI modalities like DTI in order to detect subtle regional alterations of hippocampal structure in schizophrenics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative data obtained by means of design-based stereology can add valuable information to studies performed on a diversity of organs, in particular when correlated to functional/physiological and biochemical data. Design-based stereology is based on a sound statistical background and can be used to generate accurate data which are in line with principles of good laboratory practice. In addition, by adjusting the study design an appropriate precision can be achieved to find relevant differences between groups. For the success of the stereological assessment detailed planning is necessary. In this review we focus on common pitfalls encountered during stereological assessment. An exemplary workflow is included, and based on authentic examples, we illustrate a number of sampling principles which can be implemented to obtain properly sampled tissue blocks for various purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD. METHODS An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm) was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp). For each protocol, at least 127 different nodules were scanned in 21-25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD) software. RESULTS The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7% ± 4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6% ± 4.3% (p = 0.031)]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists' sensitivity for detecting solid nodules at all dose levels (5-11%). No significant volume measurement errors (VMEs) were documented for the radiologists or the CAD software at any dose level. CONCLUSIONS Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Information about the size of a tumor and its temporal evolution is needed for diagnosis as well as treatment of brain tumor patients. The aim of the study was to investigate the potential of a fully-automatic segmentation method, called BraTumIA, for longitudinal brain tumor volumetry by comparing the automatically estimated volumes with ground truth data acquired via manual segmentation. Longitudinal Magnetic Resonance (MR) Imaging data of 14 patients with newly diagnosed glioblastoma encompassing 64 MR acquisitions, ranging from preoperative up to 12 month follow-up images, was analysed. Manual segmentation was performed by two human raters. Strong correlations (R = 0.83-0.96, p < 0.001) were observed between volumetric estimates of BraTumIA and of each of the human raters for the contrast-enhancing (CET) and non-enhancing T2-hyperintense tumor compartments (NCE-T2). A quantitative analysis of the inter-rater disagreement showed that the disagreement between BraTumIA and each of the human raters was comparable to the disagreement between the human raters. In summary, BraTumIA generated volumetric trend curves of contrast-enhancing and non-enhancing T2-hyperintense tumor compartments comparable to estimates of human raters. These findings suggest the potential of automated longitudinal tumor segmentation to substitute manual volumetric follow-up of contrast-enhancing and non-enhancing T2-hyperintense tumor compartments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

DNA vaccines or proteins are capable of inducing specific immunity; however, the translation to the clinic has generally been problematic, primarily due to the reduced magnitude of immune response and poor pharmacokinetics. Herein we demonstrate a composite microsphere formulation, composed of mesoporous silica spheres (MPS) and poly(d,l-lactide-co-glycolide) (PLGA), enables the controlled delivery of a prime-boost vaccine via the encapsulation of plasmid DNA (pDNA) and protein in different compartments. Method with modified dual-concentric-feeding needles attached to a 40 kHz ultrasonic atomizer was studied. These needles focus the flow of two different solutions, which passed through the ultrasonic atomizer. The process synthesis parameters, which are important to the scale-up of composite microspheres, were also studied. These parameters include polymer concentration, feed flowrate, and volumetric ratio of polymer and pDNA-PEI/MPS-BSA. This fabrication technique produced composite microspheres with mean D[4,3] ranging from 6 to 34 μm, depending upon the microsphere preparation. The resultant physical morphology of composite microspheres was largely influenced by the volumetric ratio of pDNA-PEI/MPS-BSA to polymer, and this was due to the precipitation of MPS at the surface of the microspheres. The encapsulation efficiencies were predominantly in the range of 93-98% for pDNA and 46-68% for MPS. In the in vitro studies, the pDNA and protein showed different release kinetics in a 40 day time frame. The dual-concentric-feeding in ultrasonic atomization was shown to have excellent reproducibility. It was concluded that this fabrication technique is an effective method to prepare formulations containing a heterologous prime-boost vaccine in a single delivery system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The recognition of the potential efficacy of plasmid DNA (pDNA) molecules as vectors in the treatment and prevention of emerging diseases has birthed the confidence to combat global pandemics. This is due to the close-to-zero safety concern associated with pDNA vectors compared to viral vectors in cell transfection and targeting. Considerable attention has been paid to the potential of pDNA vectors but comparatively less thought has been given to the practical challenges in producing large quantities to meet current rising demands. A pilot-scale fermentation scheme was developed by employing a stoichiometrically-designed growth medium whose exceptional plasmid yield performance was attested in a shake flask environment for pUC19 and pEGFP-N1 transformed into E. coliDH5α and E. coliJM109, respectively. Batch fermentation of E. coliDH5α-pUC19 employing the stoichiometric medium displayed a maximum plasmid volumetric and specific yield of 62.6 mg/L and 17.1 mg/g (mg plasmid/g dry cell weight), respectively. Fed-batch fermentation of E. coliDH5α-pUC19 on a glycerol substrate demonstrated one of the highest ever reported pilot-scale plasmid specific yield of 48.98 mg/g and a volumetric yield of 0.53 g/L. The attainment of high plasmid specific yields constitutes a decrease in plasmid manufacturing cost and enhances the effectiveness of downstream processes by reducing the proportion of intracellular impurities. The effect of step-rise temperature induction was also considered to maximize ColE1-origin plasmid replication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Current developments in gene medicine and vaccination studies are utilizing plasmid DNA (pDNA) as the vector. For this reason, there has been an increasing trend towards larger and larger doses of pDNA utilized in human trials: from 100-1000 μg in 2002 to 500-5000 μg in 2005. The increasing demand of pDNA has created the need to revolutionalize current production levels under optimum economy. In this work, different standard media (LB, TB and SOC) for culturing recombinant Escherichia coli DH5α harbouring pUC19 were compared to a medium optimised for pDNA production. Lab scale fermentations using the standard media showed that the highest pDNA volumetric and specific yields were for TB (11.4 μg/ml and 6.3 μg/mg dry cell mass respectively) and the lowest was for LB (2.8 μg/ml and 3.3 μg/mg dry cell mass respectively). A fourth medium, PDMR, designed by modifying a stoichiometrically-formulated medium with an optimised carbon source concentration and carbon to nitrogen ratio displayed pDNA volumetric and specific yields of 23.8 μg/ml and 11.2 μg/mg dry cell mass respectively. However, it is the economic advantages of the optimised medium that makes it so attractive. Keeping all variables constant except medium and using LB as a base scenario (100 medium cost [MC] units/mg pDNA), the optimised PDMR medium yielded pDNA at a cost of only 27 MC units/mg pDNA. These results show that greater amounts of pDNA can be obtained more economically with minimal extra effort simply by using a medium optimised for pDNA production.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone mass acquired during childhood is the primary determinant of adult bone mineral density (BMD) and osteoporosis risk. Bone accrual is subject to genetic influences. Activating and inactivating LRP5 gene mutations elicit extreme bone phenotypes, while more common LRP5 polymorphisms are associated with normal variation of BMD. Our aim was to test the hypothesis that LRP5 gene polymorphisms influence bone mass acquisition during childhood. The association between LRP5 gene polymorphisms and bone size and mineralization was examined in 819 unrelated British Caucasian children (n = 429 boys) aged 9 years. Height, weight, pubertal status (where available), total-body and spinal bone area, bone mineral content (BMC), BMD, and area-adjusted BMC (aBMC) were assessed. Dual-energy X-ray absorptiometry (DXA)-gene associations were assessed by linear regression, with adjustment for age, gender, pubertal status, and body size parameters. There were 140, 79, 12, and 2 girls who achieved Tanner stages I-IV, respectively, and 179 and 32 boys who achieved Tanner stages I and II, respectively. The rs2306862 (N740N) coding polymorphism in exon 10 of the LRP5 gene was associated with spinal BMD and aBMC (each P = 0.01) and total-body BMD and aBMC (P = 0.04 and 0.03, respectively). Adjusting for pubertal stage strengthened associations between this polymorphism and spinal BMD and aBMC (P = 0.01 and 0.002, respectively). Individuals homozygous for the T allele had greater spinal BMD and aBMC scores than those homozygous for the C allele. A dose effect was apparent as the mean spinal BMD and aBMC of heterozygous TC individuals were intermediate between those of their TT and CC counterparts. The N740N polymorphism in exon 10 of LRP5 was associated with spinal BMD and aBMC in pre- and early pubertal children. These results indicate that LRP5 influences volumetric bone density in childhood, possibly through effects on trabecular bone formation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Na reação de desidrogenação oxidativa de propano (ODHP), propano reage com oxigênio da superfície de metais de transição para produzir propeno e água, em temperaturas de 300-700C. Porém, o propeno pode facilmente oxidar, formando CO e CO2. Assim, busca-se catalisadores que promovam a seletividade do propeno. Compostos tipo hidrotalcitas estão sendo apontados como catalisadores de grande potencial para a reação. Portanto, o principal objetivo desse trabalho foi sintetizar precursores tipo hidrotalcitas (contendo íons Ni2+, Mg2+ e Al3+ e tereftalato, heptamolibdato e decavanadato como ânions de compensação) para serem testados na reação de desidrogenação oxidativa de propano. Esses precursores foram sintetizados com uma razão Al/(Al+Ni+Mg)=0,5, variando a razão de Ni/Mg. Além disso, realizou-se a troca iônica do tereftalato (TA) por heptamolibdato (Mo7O24) e decavanadato (V10O28). Esses compostos foram calcinados, obtendo-se assim, óxidos mistos de NiMgAl, NiMgAlMo e NiMgAlV que foram testados como catalisadores na reação de ODHP. Para a determinação das propriedades dos catalisadores foram usadas as técnicas de caracterização: DRX, TGA, volumetria de N2, TPR, Raman e FTIR e ICP. Os resultados indicaram que os materiais tipo hidrotalcita foram obtidos com sucesso. No caso dos precursores preparados por troca iônica a cristalinidade foi menor que os da série NiMgAl-TA. Estes mesmos precursores quando calcinados apresentaram áreas muito altas. Nas três séries, os precursores calcinados são constituídos por óxidos mistos como NiO, NiMoO4, Ni2V2O7 cristalinos e espécies de alumínio e magnésio não detectados na DRX. No teste catalítico de ODHP, observou-se que com o aumento da conversão diminuía a seletividade de propeno, para os óxidos mistos que não continham molibdênio. Os catalisadores da série molibdênio foram os que obtiveram melhor desempenho com altas seletividades, mesmo em altas conversões e a série de cujo precursor foi o tereftalato foi a que exibiu maiores conversões, mas com seletividades menores que da série de Mo