992 resultados para slow cooling storage


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, quality of fresh, slow frozen and quick frozen tilapia fillets and its changes during storage at -18C° were investigated. For preparation the samples, fresh tilapia fillets were frozen by slow and quick frozen methods. Slow frozen samples were prepared by storing the packed fillets directly in the -18 C°. The sprila freezing tunle with -30C° was also used for preparation the quick frozen sample. The quick frozen samples were then stored at -18C°for six months. Proximate composition, fatty acid profiles, TBA, PV, TVN, Total cuont, Drip loss, and sensory evaluation of the samples were determined in every month. Scanning Electron Microscopy (SEM) was used for study on the effects of the frozen condition on the microstructure of the fillets. Results indicated that two different frozen methods had significantly different effects on the quality of the fillets. Most of the proximate composition (protein, moistre and fat) reduced during the storage. Quick frozen filets had significantly (P<0.05) lower reduction than slow frozen samples. All of the chemical quality indexes (PV, TBA, and TVN) increased during the storage as compered to the fresh samples. In these paramethers, the slow freezing had higher changes than quick freezing metods (P<0.05). The microbial properties of the samples showed decrese during the storage. Lower amont of total cuont was observed at the end of the storage time in the quick frozen samples than slow frozen once (P<0.05). The large changes in the fatty acid profiles of the sample were fond in all samples. During the storage SFA and MUF of the samples increased however, the PUFA decresed. A lower change was obseved in the quick frozen samples than slow frozen samples (P<0.05). Drip loss was increased in both frozen samples during the storage period. The percentage of the drip in the slow frozen samples was significantly higer than quick frozen samples (P<0.05). SEM micrographs were also showed that the chnges in the microstructur of the samples was different in the slow and frozen samples. Slow freezing methods had higher damge in the microstructure of the sample then quick freezing mathods. Sensory evaluation of the samples indicated that a better acceptability in the quick frozen samples than slow frozen sample (P<0.05).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low-cost optical switches based on SLMs have conventionally been considered unsuitable for packet switching due to slow reconfiguration time. In this paper, we demonstrate that the constraint of SLM reconfiguration time in a hybrid three-stage electronic/optical switching node architecture can be compensated through the utilization of MPLS label switching mechanism to achieve the best performance for SAN applications. © 2012 SEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The formations of the surface plasmonpolariton (SPP) bands in metal/air/metal (MAM) sub-wavelength plasmonic grating waveguide (PGW) are proposed. The band gaps originating from the highly localized resonances inside the grooves can be simply estimated from the round trip phase condition. Due to the overlap of the localized SPPs between the neighboring grooves, a Bloch mode forms in the bandgap and can be engineered to build a very flat dispersion for slow light. A chirped PGW with groove depth varying is also demonstrated to trap light, which is validated by finite-difference time-domain (FDTD) simulations with both continuous and pulse excitations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Application of electron-cooling upgrades the quality of ion beams in the storage rings and brings new problems. The transverse magnetic field distorts the ion orbit while guiding the intense electron beam. The closed-orbit distortion should be and can be localized and controlled well inside the ring acceptance. This paper deals with the field in the e-cool section and concomitant COD of ion orbit and shows the correction scheme.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The commissioning of the cooler storage rings (CSR) was successful, and the facility provides new possibilities for atomic physics with highly charged ions. Bare carbon, argon ions, were successfully stored in the main ring CSRm, cooled by cold electron beam, and accelerated up to 1 GeV/u. Heavier ions as Xe44+ and Kr28+ were also successfully stored in the CSRs. Both of the rings are equipped with new generation of electron coolers which can provide different electron beam density distributions. Electron-ion interactions, high precision X-ray spectroscopy, complete kinematical measurements for relativistic ion-atom collisions will be performed at CSRs. Laser cooling of heavy ions are planned as well. The physics programs and the present status will be summarized.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper will discuss Computational Fluid Dynamics (CFD) results from an investigation into the accuracy of several turbulence models to predict air cooling for electronic packages and systems. Also new transitional turbulence models will be proposed with emphasis on hybrid techniques that use the k-ε model at an appropriate distance away from the wall and suitable models, with wall functions, near wall regions. A major proportion of heat emitted from electronic packages can be extracted by air cooling. This flow of air throughout an electronic system and the heat extracted is highly dependent on the nature of turbulence present in the flow. The use of CFD for such investigations is fast becoming a powerful and almost essential tool for the design, development and optimization of engineering applications. However turbulence models remain a key issue when tackling such flow phenomena. The reliability of CFD analysis depends heavily on the turbulence model employed together with the wall functions implemented. In order to resolve the abrupt fluctuations experienced by the turbulent energy and other parameters located at near wall regions and shear layers a particularly fine computational mesh is necessary which inevitably increases the computer storage and run-time requirements. The PHYSICA Finite Volume code was used for this investigation. With the exception of the k-ε and k-ω models which are available as standard within PHYSICA, all other turbulence models mentioned were implemented via the source code by the authors. The LVEL, LVEL CAP, Wolfshtein, k-ε, k-ω, SST and kε/kl models are described and compared with experimental data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the manufacture of granular NPK fertilizer the product is cooled before packaging and storage in moisture-proof bags. It has been shown that the temperature of the fertilizer prior to packing is significant in that at high temperatures, drying of the granules takes place in the bag which causes an increase in the humidity of the air surrounding the granules and thus an increase in moisture content at the granule - granule interface. This surface moisture was shown to increase the likelihood of agglomeration in the fertilizer by a capillary adhesion/unconfined yield stress model. An iterative model was set up to establish conditions that would prevent drying occurring, which takes into account fertilizer drying rate, fertilizer cooling rate cooling rate and the effect of coating oils on the drying mechanism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heating and cooling temperature jumps (T-jumps) were performed using a newly developed technique to trigger unfolding and refolding of wild-type ribonuclease A and a tryptophan-containing variant (Y115W). From the linear Arrhenius plots of the microscopic folding and unfolding rate constants, activation enthalpy (ΔH#), and activation entropy (ΔS#) were determined to characterize the kinetic transition states (TS) for the unfolding and refolding reactions. The single TS of the wild-type protein was split into three for the Y115W variant. Two of these transition states, TS1 and TS2, characterize a slow kinetic phase, and one, TS3, a fast phase. Heating T-jumps induced protein unfolding via TS2 and TS3; cooling T-jumps induced refolding via TS1 and TS3. The observed speed of the fast phase increased at lower temperature, due to a strongly negative ΔH# of the folding-rate constant. The results are consistent with a path-dependent protein folding/unfolding mechanism. TS1 and TS2 are likely to reflect X-Pro114 isomerization in the folded and unfolded protein, respectively, and TS3 the local conformational change of the β-hairpin comprising Trp115. A very fast protein folding/unfolding phase appears to precede both processes. The path dependence of the observed kinetics is suggestive of a rugged energy protein folding funne

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Improved upland rice cultivars introduced in Volta Region, Ghana, have been perceived to store poorly compared to farmers' traditional cultivars. A survey was conducted in 2003 in the Hohoc district of this region, where a participatory Varietal Selection programme had started in 1997, to gain insight into fanners' seed production and storage practices that are likely to affect seed quality in storage. Farmers rated keeping quality (p < 0.001), tolerance to storage pests (p < 0.001), seed quality (p < 0.001) and establishment of their local cultivars Kawomo, Viono and Wuwulili as much better than the improved cultivar IDSA 85. Initial seed moisture content ranged from 12.8 to 18% and germination from 0 to 82%. There was a significant relationship between seed moisture content and duration of drying prior to storage (p < 0.001) and storage method (p = 0.015). Germination loss in storage was rapid at high moisture content and slow at low moisture content. Between 60 and 80% of seeds germinated after six Months storage at 12.8% moisture content. The viability equation predicted accurately germination of farmer-saved seed stored under ambient temperature in Ghana. Except for the japonica rice cultivar WAB 126-18-HB, the traditional cultivars Kawomo, Viono and Wuwulili survived better in storage than improved cultivars. There is a need to improve seed quality of improved cultivars if farmers are to benefit from their higher yields and grain quality and to improve storage practices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Changes occurring in the viability of Salmonella enterica subsp. enterica during the preparation and cold storage of Domiati cheese, Kariesh cheese and ice-cream were examined. A significant decrease in numbers was observed after whey drainage during the manufacture of Domiati cheese, but Salmonella remained viable for 13 weeks in cheeses prepared from milks with between 60 and 100 g/L NaCl; the viability declined in Domiati cheese made from highly salted milk during the later stages of storage. The method of coagulation used in the preparation of Kariesh cheese affected the survival time of the pathogen, and it varied from 2 to 3 weeks in cheeses made with a slow-acid coagulation method to 4-5 weeks for an acid-rennet coagulation method. This difference was attributed to the higher salt-in-moisture levels and lower pH values of Kariesh cheese prepared by the slow-acid coagulation method. A slight decrease in the numbers of Salmonella resulted from ageing ice-cream mix for 24 h at 0degreesC, but a greater reduction was evident after one day of frozen storage at -20degreesC. The pathogen survived further frozen storage for four months without any substantial change in numbers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the 1960s and early 1970s sea surface temperatures in the North Atlantic Ocean cooled rapidly. There is still considerable uncertainty about the causes of this event, although various mechanisms have been proposed. In this observational study it is demonstrated that the cooling proceeded in several distinct stages. Cool anomalies initially appeared in the mid-1960s in the Nordic Seas and Gulf Stream Extension, before spreading to cover most of the Subpolar Gyre. Subsequently, cool anomalies spread into the tropical North Atlantic before retreating, in the late 1970s, back to the Subpolar Gyre. There is strong evidence that changes in atmospheric circulation, linked to a southward shift of the Atlantic ITCZ, played an important role in the event, particularly in the period 1972-76. Theories for the cooling event must account for its distinctive space-time evolution. Our analysis suggests that the most likely drivers were: 1) The “Great Salinity Anomaly” of the late 1960s; 2) An earlier warming of the subpolar North Atlantic, which may have led to a slow-down in the Atlantic Meridional Overturning Circulation; 3) An increase in anthropogenic sulphur dioxide emissions. Determining the relative importance of these factors is a key area for future work.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate how sea surface temperatures (SSTs) around Antarctica respond to the Southern An- nular Mode (SAM) on multiple timescales. To that end we examine the relationship between SAM and SST within unperturbed preindustrial control simulations of coupled general circulation models (GCMs) included in the Climate Modeling Intercomparison Project phase 5 (CMIP5). We develop a technique to extract the re- sponse of the Southern Ocean SST (55◦S−70◦S) to a hypothetical step increase in the SAM index. We demonstrate that in many GCMs, the expected SST step re- sponse function is nonmonotonic in time. Following a shift to a positive SAM anomaly, an initial cooling regime can transition into surface warming around Antarctica. However, there are large differences across the CMIP5 ensemble. In some models the step response function never changes sign and cooling persists, while in other GCMs the SST anomaly crosses over from negative to positive values only three years after a step increase in the SAM. This intermodel diversity can be related to differences in the models’ climatological thermal ocean stratification in the region of seasonal sea ice around Antarctica. Exploiting this relationship, we use obser- vational data for the time-mean meridional and vertical temperature gradients to constrain the real Southern Ocean response to SAM on fast and slow timescales.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The need for heating and cooling in buildings constitutes a considerable part of the total energy use in a country and reducing this need is of outmost importance in order to reach national and international goals for reducing energy use and emissions. One important way of reaching these goals is to increase the proportion of renewable energy used for heating and cooling of buildings. Perhaps the largest obstacle with this is the often occurring mismatch between the availability of renewable energy and the need for heating or cooling, hindering this energy to be used directly. This is one of the problems that can be solved by using thermal energy storage (TES) in order to save the heat or cold from when it is available to when it is needed. This thesis is focusing on the combination of TES techniques and buildings to achieve increased energy efficiency for heating and cooling. Various techniques used for TES as well as the combination of TES in buildings have been investigated and summarized through an extensive literature review. A survey of the Swedish building stock was also performed in order to define building types common in Sweden. Within the scope of this thesis, the survey resulted in the selection of three building types, two single family houses and one office building, out of which the two residential buildings were used in a simulation case study of passive TES with increased thermal mass (both sensible and latent). The second case study presented in the thesis is an evaluation of an existing seasonal borehole storage of solar heat for a residential community. In this case, real measurement data was used in the evaluation and in comparisons with earlier evaluations. The literature reviews showed that using TES opens up potential for reduced energy demand and reduced peak heating and cooling loads as well as possibilities for an increased share of renewable energy to cover the energy demand. By using passive storage through increased thermal mass of a building it is also possible to reduce variations in the indoor temperature and especially reduce excess temperatures during warm periods, which could result in avoiding active cooling in a building that would otherwise need it. The analysis of the combination of TES and building types confirmed that TES has a significant potential for increased energy efficiency in buildings but also highlighted the fact that there is still much research required before some of the technologies can become commercially available. In the simulation case study it was concluded that only a small reduction in heating demand is possible with increased thermal mass, but that the time with indoor temperatures above 24 °C can be reduced by up to 20%. The case study of the borehole storage system showed that although the storage system worked as planned, heat losses in the rest of the system as well as some problems with the system operation resulted in a lower solar fraction than projected. The work presented within this thesis has shown that TES is already used successfully for many building applications (e.g. domestic hot water stores and water tanks for storing solar heat) but that there still is much potential in further use of TES. There are, however, barriers such as a need for more research for some storage technologies as well as storage materials, especially phase change material storage and thermochemical storage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a Nordic climate, space heating (SH) and domestic hot water (DHW) used in buildings constitute a considerable part of the total energy use in the country. For 2010, energy used for SH and DHW amounted to almost 90 TWh in Sweden which corresponds to 60 % of the energy used in the residential and service sector, or almost 24 % of the total final energy use for the country. Storing heat and cold with the use of thermal energy storage (TES) can be one way of increasing the energy efficiency of a building by opening up possibilities for alternative sources of heat or cold through a reduced mismatch between supply and demand. Thermal energy storage without the use of specific control systems are said to be passive and different applications using passive TES have been shown to increase energy efficiency and/or reduce power peaks of systems supplying the heating and cooling needs of buildings, as well as having an effect on the indoor climate. Results are however not consistent between studies and focus tend to be on the reduction of cooling energy or cooling power peaks. In this paper, passive TES introduced through an increased thermal mass in the building envelope to two single family houses with different insulation standard is investigated with building energy simulations. A Nordic climate is used and the focus of this study is both on the reduction of space heating demand and space heating power, as well as on reduction of excess temperatures in residential single family houses without active cooling systems. Care is taken to keep the building envelope characteristics other than the thermal mass equal for all cases so that any observations made can be derived to the change in thermal mass. Results show that increasing the sensible thermal mass in a single family house can reduce the heating demand only slightly (1-4 %) and reduce excess temperatures (temperatures above 24 degrees C) by up to 20 %. Adding a layer of PCM (phase change materials) to the light building construction can give similar reduction in heating demand and excess temperatures, however the phase change temperature is important for the results.