936 resultados para sensitivity and specificity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To retrospectively assess the diagnostic sensitivity of 45° Dunn view and cross-table lateral radiographs for the assessment of cam deformity by comparison with radial MRI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Meta-analysis of predictive values is usually discouraged because these values are directly affected by disease prevalence, but sensitivity and specificity sometimes show substantial heterogeneity as well. We propose a bivariate random-effects logitnormal model for the meta-analysis of the positive predictive value (PPV) and negative predictive value (NPV) of diagnostic tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The German version of the Conners Adult ADHD Rating Scales (CAARS) has proven to show very high model fit in confirmative factor analyses with the established factors inattention/memory problems, hyperactivity/restlessness, impulsivity/emotional lability, and problems with self-concept in both large healthy control and ADHD patient samples. This study now presents data on the psychometric properties of the German CAARS-self-report (CAARS-S) and observer-report (CAARS-O) questionnaires.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluorescence microlymphography (FML) is used to visualize the lymphatic capillaries. A maximum spread of the fluorescence dye of ≥ 12 mm has been suggested for the diagnosis of lymphedema. However, data on sensitivity and specificity are lacking. The aim of this study was to investigate the accuracy of FML for diagnosing lymphedema in patients with leg swelling. Patients with lower extremity swelling were clinically assessed and separated into lymphedema and non-lymphatic edema groups. FML was studied in all affected legs and the maximum spread of lymphatic capillaries was measured. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess possible threshold values that predict lymphedema. Between March 2008 and August 2011 a total of 171 patients (184 legs) with a median age of 43.5 (IQR 24, 54) years were assessed. Of those, 94 (51.1%) legs were diagnosed with lymphedema. The sensitivity, specificity, positive and negative likelihood ratio and positive and negative predictive value were 87%, 64%, 2.45, 0.20, 72% and 83% for the 12-mm cut-off level and 79%, 83%, 4.72, 0.26, 83% and 79% for the 14-mm cut-off level, respectively. The area under the ROC curve was 0.82 (95% CI: 0.76, 0.88). Sensitivity was higher in the secondary versus primary lymphedema (95.0% vs 74.3%, p = 0.045). No major adverse events were observed. In conclusion, FML is a simple and safe technique for detecting lymphedema in patients with leg swelling. A cut-off level of ≥ 14-mm maximum spread has a high sensitivity and high specificity of detecting lymphedema and should be chosen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the study was to determine the sensitivity and specificity for typical abdominal injuries after major blunt trauma in postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Anecdotal evidence suggests that the sensitivity and specificity of a diagnostic test may vary with disease prevalence. Our objective was to investigate the associations between disease prevalence and test sensitivity and specificity using studies of diagnostic accuracy. METHODS We used data from 23 meta-analyses, each of which included 10-39 studies (416 total). The median prevalence per review ranged from 1% to 77%. We evaluated the effects of prevalence on sensitivity and specificity using a bivariate random-effects model for each meta-analysis, with prevalence as a covariate. We estimated the overall effect of prevalence by pooling the effects using the inverse variance method. RESULTS Within a given review, a change in prevalence from the lowest to highest value resulted in a corresponding change in sensitivity or specificity from 0 to 40 percentage points. This effect was statistically significant (p < 0.05) for either sensitivity or specificity in 8 meta-analyses (35%). Overall, specificity tended to be lower with higher disease prevalence; there was no such systematic effect for sensitivity. INTERPRETATION The sensitivity and specificity of a test often vary with disease prevalence; this effect is likely to be the result of mechanisms, such as patient spectrum, that affect prevalence, sensitivity and specificity. Because it may be difficult to identify such mechanisms, clinicians should use prevalence as a guide when selecting studies that most closely match their situation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

People with sequence-space synesthesia (SSS) report stable visuo-spatial forms corresponding to numbers, days, and months (amongst others). This type of synesthesia has intrigued scientists for over 130 years but the lack of an agreed upon tool for assessing it has held back research on this phenomenon. The present study builds on previous tests by measuring the consistency of spatial locations that is known to discriminate controls from synesthetes. We document, for the first time, the sensitivity and specificity of such a test and suggest a diagnostic cut-off point for discriminating between the groups based on the area bounded by different placement attempts with the same item.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The most commonly used method for formally assessing grapheme-colour synaesthesia (i.e., experiencing colours in response to letter and/or number stimuli) involves selecting colours from a large colour palette on several occasions and measuring consistency of the colours selected. However, the ability to diagnose synaesthesia using this method depends on several factors that have not been directly contrasted. These include the type of colour space used (e.g., RGB, HSV, CIELUV, CIELAB) and different measures of consistency (e.g., city block and Euclidean distance in colour space). This study aims to find the most reliable way of diagnosing grapheme-colour synaesthesia based on maximising sensitivity (i.e., ability of a test to identify true synaesthetes) and specificity (i.e., ability of a test to identify true non-synaesthetes). We show, applying ROC (Receiver Operating Characteristics) to binary classification of a large sample of self-declared synaesthetes and non-synaesthetes, that the consistency criterion (i.e., cut-off value) for diagnosing synaesthesia is considerably higher than the current standard in the field. We also show that methods based on perceptual CIELUV and CIELAB colour models (rather than RGB and HSV colour representations) and Euclidean distances offer an even greater sensitivity and specificity than most currently used measures. Together, these findings offer improved heuristics for the behavioural assessment of grapheme-colour synaesthesia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Gastrointestinal Short Form Questionnaire (GSFQ) is a questionnaire for gastroesophageal reflux disease (GERD) diagnosis, with a version in Spanish language, not yet compared to an objective test. Aims: To establish GSFQ diagnostic performance against 24-hour pH monitoring carried out in two tertiary care hospitals. Methods: Consecutive adult patients with typical GERD symptoms (heartburn, regurgitation) referred for pH monitoring fulfilled the GSFQ (score range 0-30, proportional to probability of GERD). Diagnosis of GERD was established when acid exposure time in distal esophagus was superior to 4.5% or symptom association probability was greater than 95%. Receiver-operator characteristic (ROC) curves were calculated and best cut-off score determined, with corresponding sensitivity, specificity and likelihood ratios (LR) (95% confidence interval for each). Results: One hundred and fifty-two patients were included (59.9% women, age 47.9 ± 13.9; 97.4% heartburn; 71.3% regurgitation). pH monitoring was abnormal in 65.8%. Mean GSFQ score was 11.2 ± 6. Area under ROC was 56.5% (47.0-65.9%). Optimal cut-off score was 13 or greater: sensitivity 40% (30.3-50.3%), specificity 71.2% (56.9-82.9%), positive LR 1.39 (0.85-2.26) and negative LR 0.84 (0.67-1.07). Exclusion of questions 1 and 3 of the original GSFQ, easily interpreted as referred to dyspepsia and not GERD, improved only marginally the diagnostic performance: AUROC 59.1%. Conclusion: The GSFQ does not predict results of pH monitoring in patients with typical symptoms in a tertiary care setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Brazil, human and canine visceral leishmaniasis (CVL) caused by Leishmania infantum has undergone urbanisation since 1980, constituting a public health problem, and serological tests are tools of choice for identifying infected dogs. Until recently, the Brazilian zoonoses control program recommended enzyme-linked immunosorbent assays (ELISA) and indirect immunofluorescence assays (IFA) as the screening and confirmatory methods, respectively, for the detection of canine infection. The purpose of this study was to estimate the accuracy of ELISA and IFA in parallel or serial combinations. The reference standard comprised the results of direct visualisation of parasites in histological sections, immunohistochemical test, or isolation of the parasite in culture. Samples from 98 cases and 1,327 noncases were included. Individually, both tests presented sensitivity of 91.8% and 90.8%, and specificity of 83.4 and 53.4%, for the ELISA and IFA, respectively. When tests were used in parallel combination, sensitivity attained 99.2%, while specificity dropped to 44.8%. When used in serial combination (ELISA followed by IFA), decreased sensitivity (83.3%) and increased specificity (92.5%) were observed. Serial testing approach improved specificity with moderate loss in sensitivity. This strategy could partially fulfill the needs of public health and dog owners for a more accurate diagnosis of CVL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Leishmaniasis, caused by Leishmania infantum, is a vector-borne zoonotic disease that is endemic to the Mediterranean basin. The potential of rabbits and hares to serve as competent reservoirs for the disease has recently been demonstrated, although assessment of the importance of their role on disease dynamics is hampered by the absence of quantitative knowledge on the accuracy of diagnostic techniques in these species. A Bayesian latent-class model was used here to estimate the sensitivity and specificity of the Immuno-fluorescence antibody test (IFAT) in serum and a Leishmania-nested PCR (Ln-PCR) in skin for samples collected from 217 rabbits and 70 hares from two different populations in the region of Madrid, Spain. A two-population model, assuming conditional independence between test results and incorporating prior information on the performance of the tests in other animal species obtained from the literature, was used. Two alternative cut-off values were assumed for the interpretation of the IFAT results: 1/50 for conservative and 1/25 for sensitive interpretation. Results suggest that sensitivity and specificity of the IFAT were around 70–80%, whereas the Ln-PCR was highly specific (96%) but had a limited sensitivity (28.9% applying the conservative interpretation and 21.3% with the sensitive one). Prevalence was higher in the rabbit population (50.5% and 72.6%, for the conservative and sensitive interpretation, respectively) than in hares (6.7% and 13.2%). Our results demonstrate that the IFAT may be a useful screening tool for diagnosis of leishmaniasis in rabbits and hares. These results will help to design and implement surveillance programmes in wild species, with the ultimate objective of early detecting and preventing incursions of the disease into domestic and human populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we consider applying derived knowledge base regarding the sensitivity and specificity of damage(s) to be detected by an SHM system being designed and qualified. These efforts are necessary toward developing capabilities in SHM system to classify reliably various probable damages through sequence of monitoring, i.e., damage precursor identification, detection of damage and monitoring its progression. We consider the particular problem of visual and ultrasonic NDE based SHM system design requirements, where the damage detection sensitivity and specificity data definitions for a class of structural components are established. Methodologies for SHM system specification creation are discussed in details. Examples are shown to illustrate how the physics of damage detection scheme limits particular damage detection sensitivity and specificity and further how these information can be used in algorithms to combine various different NDE schemes in an SHM system to enhance efficiency and effectiveness. Statistical and data driven models to determine the sensitivity and probability of damage detection (POD) has been demonstrated for plate with varying one-sided line crack using optical and ultrasonic based inspection techniques.