779 resultados para radiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to assess the occurrence of apical root transportation after the use of Pro Taper Universal rotary files sizes 3 (F3) and 4 (F4). Methods: Instruments were worked to the apex of the original canal, always by the same operator. Digital subtraction radiography images were produced in buccolingual and mesiodistal projections. A total of 25 radiographs were taken from root canals of human maxillary first molars with curvatures varying from 23-31 degrees. Quantitative data were analyzed by intraclass correlation coefficient and Wilcoxon nonparametric test (P = .05). Results: Buccolingual images revealed a significantly higher degree of apical transportation associated with F4 instruments when compared with F3 instruments in relation to the original canal (Wilcoxon test, P = .007). No significant difference was observed in mesiodistal images (P = .492). Conclusions: F3 instruments should be used with care in curved canals, and F4 instruments should be avoided in apical third preparation of curved canals. (J Endod 2010;36:1052-1055)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All methods to detect experimental loss of bone present technique limitations. The sensitivities of image and histological analyses to detect the effects of teriparatide in rats with bone loss after ovariectomy were evaluated. All methods were qualitatively valid.The standardization of methods to assess bone loss after ovariectomy is crucial to establish the degree of experimental osteoporosis. In general, methods per image or histological techniques are used. To validate these two ways to determine the degree of bone loss in ovariectomized rats, we evaluated the sensitivities of bone densitometry, conventional radiography, and histological analysis of the area occupied by collagen, detecting the effects of teriparatide treatment in the femur of ovariectomized rats with bone loss.Wistar rats were divided into three groups: a control group, in which the animals were only subjected to laparotomy; an ovariectomized group, in which bilateral removal of the ovaries was performed; and an ovariectomized + teriparatide group, in which bilateral removal of the ovaries was performed, and the animals were treated with 3 mu g/100 g/day of teriparatide. Three months following the ovariectomy, bone densitometry, radiographic densitometry, and histological analysis of the area occupied by collagen fibers were carried out in the femur diaphysis.The bone densitometry revealed 11.2% reduction in femur density; in the conventional radiography, the loss of bone mass was 14.5%, and with the histological analysis, a 40.9% reduction in the area occupied by collagen was detected in the femur diaphysis.In conclusion, histological analysis could not be quantitatively compared with the methods of bone densitometry and conventional radiography; however, all of these methods were qualitatively valid for assessing the loss of bone stemming from ovariectomy and the therapeutic effect of teriparatide in the prevention of osteoporosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied the effects of niobium beam filtration on absorbed doses, on image density and contrast, and on photon spectra with conventional and high-frequency dental x-ray generators. Added niobium reduced entry and superficial absorbed doses in periapical radiography by 9% to 40% with film and digital image receptors, decreased the radiation necessary to produce a given image density on E-speed film and reduced image contrast on D- and E-speed films. As shown by increased half-value layers for aluminum, titanium, and copper and by pulse-height analyses of beam spectra, niobium increased average beam energy by 6% to 19%. Despite the benefits of adding niobium on patient dose reduction and on narrowing the beams' energy spectra, the beam can be overhardened. Adding niobium, therefore, strikes the best balance between radiation dose reduction and beam attenuation, with its risks of increased exposure times, motion blur, and diminished image contrast, when it is used at modest thicknesses (30 μm) and at lower kVp (70) settings. © 1995 Mosby-Year Book, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two auxiliary methods of diagnosing nasopharyngeal airway obstruction were compared. Cephalometric radiography and nasopharyngeal videoendoscopy were evaluated for efficacy in terms of reproducibility and validity. Thirty orthodontic patients (7 to 12 years of age) seeking otorhinolaryngologic treatment for mouth breathing, or mouth and nose breathing, had nasopharyngeal endoscopy and radiographic examinations performed on the same day. Two otorhinolaryngologists analyzed the results. Nasopharyngeal endoscopy was more reliable in identifying all the obstructive nasopharyngeal processes. Endoscopy obtained kappa index scores of almost perfect agreement for diagnosis of posterior nasal septum deviation, of substantial agreement for anterior nasal septum deviation and lower turbinate hypertrophy, and of moderate agreement for middle turbinate hypertrophy. Lateral cephalometric radiography obtained scores of perfect agreement for imaging hypertrophy of the middle turbinate, of almost perfect agreement for imaging hypertrophy of the posterior portion of the inferior turbinate, and of substantial agreement for imaging hypertrophy of the inferior turbinate. Radiographic diagnoses of hypertrophy of the middle and lower turbinates exhibited high sensitivity and low specificity when compared with diagnoses by nasopharyngeal endoscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: This in vitro study evaluated the accuracy of primary incisor lengths determined by digital and conventional radiography compared to the actual tooth length. Methods: Twenty extracted primary maxillary incisors were mounted in acrylic blocks. Tooth length was estimated by using a straight-line measurement provided by the distance measurement tool of a digital dental imaging system (Computed Dental Radiography, Schick Technologies Inc.) and conventional E-speed film radiographs by using a digital caliper. Two operators familiar with both radiographic methods performed the estimates. The estimated tooth lengths were compared to the actual tooth lengths measured with the digital caliper. Data were statistically analyzed by Dahlberg's equation, paired t test, Pearson's correlation coefficient and ANOVA at 5% significance level. Results: There were no statistically significant differences (p = 0.85) between tooth length estimated on digital and conventional radiographs. Admitting as clinically acceptable a 0.5-mm discrepancy between the actual tooth lengths and the radiographically estimated lengths, 60% of the radiographic measurements were considered as accurate. When the acceptable difference range was 1.0 mm, the accuracy of the radiographic measurements increased to 100%. Conclusions: Digital and conventional radiography provided similar tooth length measurements and were equivalent to the actual tooth lengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional radiography, using industrial radiographic films, has its days numbered. Digital radiography, recently, has taken its place in various segments of products and services, such as medicine, aerospace, security, automotive, etc. As well as the technological trend, the digital technique has brought proven benefits in terms of productivity, sensitivity, the environment, tools for image treatment, cost reductions, etc. If the weld to be inspected is on a serried product, such as, for example, a pipe, the best option for the use of digital radiography is the plane detector, since its use can reduce the length of the inspection cycle due to its high degree of automation. This work tested welded joints produced with the submerged arc process, which were specially prepared in such a way that it shows small artificial cracks, which served as the basis forcomparing the sensitivity levels of the techniques involved. After carrying out the various experiments, the digital meth odshowed the highest sensitivity for the image quality indicator (IQI) of the wire and also in terms of detecting small discontinuities, indicating that the use of digital radiography using the plane detector had advantages over the conventional technique (Moreira et al. Digital radiography, the use of plane detectors for the inspection of welds in oil pipes and gas pipes.9th COTEQ and XXV National Testing Congress for Non Destructive Testing and Inspection; Salvador, Bahia, Brazil and Bavendiek et al. New digital radiography procedure exceeds film sensitivity considerably in aerospace applications. ECNDT; 2006; Berlin). The works were carried out on the basis of the specifications for oil and gas pipelines, API 5L 2004 edition (American Petroleum Institute. API 5L: specification for line pipe. 4th ed. p. 155; 2004) and ISO 3183 2007 edition (International Organization for Standardization, ISO 3183. Petroleum and gas industries - steel pipes for pi pelines transportation systems. p. 143; 2007). © 2010 Taylor & Francis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atherosclerosis is a serious chronic disease, responsible for thousands of deaths worldwide and is characterized by thickening and loss of elasticity of the arterial walls, associated with the presence of atheromatous plaques. Various risk factors act directly on predisposition to the disease, among which the following are pointed out: diabetes mellitus, arterial hypertension and inadequate diet and eating habits. More recent researches have elucidated new risk factors acting in the development of this disease, such as, for example: periodontitis, chronic renal disease and menopause. The panoramic radiograph, commonly used in dental practice, makes it possible to see calcified atherosclerotic plaques that are eventually deposited in the carotid arteries. The aim of this review article was to emphasize the dentist's important role in the detection of carotid artery atheromas in panoramic radiographs and the immediate referral of patients affected by these calcifications to doctors. In addition, the study intended to guide the dentist, especially the dental radiologist, with regard to differential diagnosis, which should be made taking into consideration particularly the triticeal cartilage when it is calcified. © Henriques et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The daily-to-day of medical practice is marked by a constant search for an accurate diagnosis and therapeutic assessment. For this purpose the doctor serves up a wide variety of imaging techniques, however, the methods using ionizing radiation still the most widely used because it is considered cheaper and above all very efficient when used with control and quality. The optimization of the risk-benefit ratio is considered a major breakthrough in relation to conventional radiology, though this is not the reality of computing and digital radiology, where Brazil has not established standards and protocols for this purpose. This work aims to optimize computational chest radiographs (anterior-posterior projection-AP). To achieve this objective were used a homogeneous phantoms that simulate the characteristics of absorption and scattering of radiation close to the chest of a patient standard. Another factor studied was the subjective evaluation of image quality, carried out by visual grading assessment (VGA) by specialists in radiology, using an anthropomorphic phantom to identify the best image for a particular pathology (fracture or pneumonia). Quantifying the corresponding images indicated by the radiologist was performed from the quantification of physical parameters (Detective Quantum Efficiency - DQE, Modulation Transfer Function - MTF and Noise Power Spectrum - NPS) using the software MatLab®. © 2013 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper was to report the diagnosis and evaluation of periradicular bone repair by using computed tomography and digital subtraction radiography in an endodontic surgery case treated with mineral trioxide aggregate (MTA). The patient had local swelling and fistula 7years after trauma in the upper jaw. Periapical lesion on tooth #12 and root resorption of tooth #11 were detected radiographically. Endodontic therapy and placement of intracanal medication were carried out. After 3months, with no improvement in the clinical signs and symptoms, computed tomography was performed, showing extensive apical bone resorption on tooth #12 and dental resorption promoting communication of the root canal with the periodontium of tooth #11. The patient was referred to endodontic surgery. After surgery and postoperative periods of 15, 30, 60, 90, and 120days, standardized radiographs were taken, digitized, and subjected to digital subtraction of the images using Adobe Photoshop CS software. Four years later, a cone-beam computed tomography was performed, showing bone repair and absence of root resorption at tooth #11. In this clinical case, digital subtraction radiography was effective for early detection of new bone formation and evolution of repair. © 2011 John Wiley & Sons A/S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The imaging is essential to aid the diagnosis of horses that have performance decrease associated with any pain or clinical signs related to the vertebral column. Radiography is the first imaging examination performed in these cases, particularly for disorders affecting the cervical region. However, this technique has limitations when the study of subtle changes due to the overlapping of adjacent structures. Computed tomography is a new diagnostic method in Brazil for the study of bone disorders in horses, but it is of great diagnostic value associate with the radiographic examination in order to provide an accurate assessment of the study area, owing to superiority in image quality when compared to conventional radiography. The aim of this study is increase and update knowledge of diagnostic imaging available to investigate cervical disorders in horses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption) that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm). The apparent tooth length (APTL) was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0), whereas the actual tooth length (ACTL) was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson’s correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to optimize a radiographic technique for hand examinations using a computed radiography (CR) system and demonstrate the potential for dose reductions compared with clinically established technique. An exposure index was generated from the optimized technique to guide operators when imaging hands. Homogeneous and anthropomorphic phantoms that simulated a patient's hand were imaged using a CR system at various tube voltages and current settings (40-55 kVp, 1.25-2.8 mAs), including those used in clinical routines (50 kVp, 2.0 mAs) to obtain an optimized chart. The homogeneous phantom was used to assess objective parameters that are associated with image quality, including the signal difference-to-noise ratio (SdNR), which is used to define a figure of merit (FOM) in the optimization process. The anthropomorphic phantom was used to subjectively evaluate image quality using Visual Grading Analysis (VGA) that was performed by three experienced radiologists. The technique that had the best VGA score and highest FOM was considered the gold standard (GS) in the present study. Image quality, dose and the exposure index that are currently used in the clinical routine for hand examinations in our institution were compared with the GS technique. The effective dose reduction was 67.0%. Good image quality was obtained for both techniques, although the exposure indices were 1.60 and 2.39 for the GS and clinical routine, respectively.