INTRODUCTION: Behavioral and electrophysiological auditory evaluations contribute to the understanding of the auditory system and of the process of intervention. OBJECTIVE: To study P300 in subjects with severe or profound sensorineural hearing loss. METHODS: This was a descriptive cross-sectional prospective study. It included 29 individuals of both genders with severe or profound sensorineural hearing loss without other type of disorders, aged 11 to 42 years; all were assessed by behavioral audiological evaluation and auditory evoked potentials. RESULTS: A recording of the P3 wave was obtained in 17 individuals, with a mean latency of 326.97 ms and mean amplitude of 3.76 V. There were significant differences in latency in relation to age and in amplitude according to degree of hearing loss. There was a statistically significant association of the P300 results with the degrees of hearing loss (p = 0.04), with the predominant auditory communication channels (p < 0.0001), and with time of hearing loss. CONCLUSIONS: P300 can be recorded in individuals with severe and profound congenital sensorineural hearing loss; it may contribute to the understanding of cortical development and is a good predictor of the early intervention outcome.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: to analyze the levels of noise emitted by nationally-sold toys for use by children from 1 to 5 year old; to compare the values among the toys with and without the seal of Inmetro (National Institute of Metrology, Standardization and Industrial Quality) and to analyze the sound spectrum of toys, in order to identify the area of the cochlea that may be more affected by these noises. METHOD: measurements were performed on 20 sound toys (10 with the seal of the Inmetro and 10 without the seal) with the use of digital sound level meter in an acoustically treated room, and the sound analysis was performed using the Praat program. RESULTS: toys placed at 2.5 cm from the equipment with the seal of the Inmetro had an intensity ranging from 61.50 to 91.55 dB (A) and from 69.75 to 95.05 dB (C), positioned at 25 cm ranged from 58.3 to 79.85 dB (A) and from 62.50 to 83.65 dB (C). The results of the toys without warranty stamps placed at 2.5 cm ranged from 67.45 to 94.30 dB (A) and 65.4 to 99.50 dB (C) and the distance of 25 cm recorded from 61. 30 to 87.45 dB (A) and 63.75 to 97.60 dB (C), so that the findings demonstrated that there are noisy toys that go beyond the values recommended by the current legislation in both groups, with and without warranty stamps . CONCLUSION: the toys without the seal of Inmetro showed intensities values significantly higher than the other group, offering more risk to the children s hearing health.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: A variety of hypotheses have been proposed to explain the association between temporomandibular disorders and hearing symptoms, including the many anatomical and/or neurological ways, as of a muscle or joint dysfunction, can cause such symptoms. Objective: The purpose of this study is to discuss, through a systematic review of literature, the interrelation between hearing symptoms and temporomandibular disorders. Material and Methods: We consulted the Medline/PubMed, ISI and Scielo in the period 1918 to 2008. The terms related to the research were: “temporomandibular disorders”, “signs and symptoms of temporomandibular disorders”, “otologic symptoms” and “aural symptoms”, where 19 papers were included using the pre-selected criteria for the manufacture of a meta-analysis. Results: According to the findings, the hearing symptoms most often associated with temporomandibular disorders were otalgia and tinnitus, followed by vertigo and hearing loss, respectively. Conclusions: It’s clear the correlation between hearing symptoms and temporomandibular disorders, however there is a need clinical and scientific research more complex to prove the specific cause-effect relationships between them.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

According to Statistical Yearbook of Social Security (2011), the number of accidents at work recorded in the agricultural sector is quite high, in the year 2010 there are records of thirty-four thousand nine hundred and ninetysix accidents, and in the year of 2011 there were thirty-one thousand and ninety-six accidents in the industry. Among so many diseases and accidents at work hearing loss is one of them. According to the Pan American Health Organization (2011) the Occupational hearing loss is then jury to the worker's health, often in the workplace. Mechanical vibrations are also present in many human activities exposing employees to an extremely aggressive agent. The combined action of these two factors can cause damage to the health of the worker, in this way, noise and vibration are the two major occupational agents present in the brush cutter operator activity. In the case there is another risk factor, the open work, which exposes the employee to the Sun’s rays and the high temperature indices. Studies have shown that: noise exceeds 115 dB (A) vibration 4.0 m/s2 and thermal stress of 29.9 o C. Ergonomic evaluations also demonstrated that the activity cause injury to workers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A inexistência de espaços adaptados às pessoas com algum tipo de deficiência compromete o direito à vida, à liberdade e à segurança pessoal, assegurados a todos os seres humanos. Nesse contexto, observa-se a necessidade de planejar um local adequado aos deficientes auditivos, sejam eles surdos ou com perda auditiva. Todas as deficiências têm características próprias e acessibilidades necessárias, que refletem na importância de criar espaços planejados. O intuito não é criar um espaço que os separe e sim que crie condições de aprendizado e os insira na sociedade. O presente trabalho objetiva o projeto de um Centro de Apoio e Lazer para Deficientes Auditivos na cidade de Presidente Prudente - SP

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To evaluate the hearing status of patients being treated for pulmonary tuberculosis at referral hospitals in Brazil. Methods: This was a descriptive study involving 97 male and female inpatients/outpatients between 18 and 60 years of age who were undergoing treatment for active pulmonary tuberculosis at one of two referral hospitals in the state of Rio de Janeiro. After being interviewed, all of the patients underwent pure tone audiometry. Results: OF the 97 patients studied, 65 (67%) were male, 52 (54%) were receiving first-line treatment, and 45 (46%) were receiving second-line treatment, which included aminoglycosides. Smoking, alcohol consumption, exposure to noise, and ototoxic medication use were identified in 65 (67%), 51 (53%), 53 (55%), and 45 (46.4%) of the patients, respectively. The most common auditory and vestibular complaints were dizziness, in 28 patients (28.8%); tinnitus, in 27 (27.8%); and hypoacusis, in 23 (23.7%). Conclusions: Due to the great number of patients with hearing loss in the present study, we recommend that all patients under tuberculosis treatment be submitted to auditory monitoring.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of cochlear implant (CI) in children enables the development of listening and communication skills, allowing the child's progress in school and to be able to obtain, maintain and carry out an occupation. However, the progress after the CI has different results in some children, because many children are able to interact and participate in society, while others develop limited ability to communicate verbally. The need for a better understanding of CI outcomes, besides hearing and language benefits, has spurred the inclusion of quality of life measurements (QOL) to assess the impact of this technology. OBJECTIVE: Identify the key aspects of quality of life assessed in children with cochlear implant. METHOD: Through a systematic literature review, we considered publications from the period of 2000 to 2011. CONCLUSION: We concluded that QOL measurements in children include several concepts and methodologies. When referring to children using CI, results showed the challenges in broadly conceptualizing which quality of life domains are important to the child and how these areas can evolve during development, considering the wide variety of instruments and aspects evaluated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To validate a monitoring questionnaire about hearing and language development applied by community health agents in the first year of life. Methods: Seventy six community health agents, previously trained on infant hearing health, administered a questionnaire to the families of 304 children with ages from 0 to 1 year. The questionnaire contains questions regarding hearing and language development and, for all age groups, the question “Does your child hear well?” was presented. The validity of the questionnaire was assessed by analyzing false positive and false negative rates of the identified children. A double-blind study was conducted so that all children assessed by the questionnaire were submitted to hearing evaluation performed by audiologists. Results: Four children (1.32%) were diagnosed with sensorineural hearing loss (two unilateral), and 69 (22.7%) with conductive hearing loss. The monitoring questionnaire showed specificity of 96% and sensitivity of 67%, with a false-negative rate of 33% for not identifying the unilateral hearing loss, and a false-positive rate of 4%. Conclusion: The questionnaire used has shown to be feasible and relevant to actions of the community health agents of the Family Health Strategy program, with high specificity and moderate sensitivity. The use of the validated instrument should be considered to complement Newborn Hearing Screening Programs, in order to identify late onset or acquired hearing loss.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the present days it is critical to identify the factors that contribute to the quality of the audiologic care provided. The hearing aid fitting model proposed by the Brazilian Unified Health System (SUS) implies multidisciplinary care. This leads to some relevant and current questions. OBJECTIVE: To evaluate and compare the results of the hearing aid fitting model proposed by the SUS with a more compact and streamlined care. METHOD: We conducted a prospective longitudinal study with 174 participants randomly assigned to two groups: SUS Group and Streamline Group. For both groups we assessed key areas related to hearing aid fitting through the International Outcome Inventory for Hearing Aids (IOI-HA) questionnaire, in addition to evaluating the results of Speech Recognition Index (SRI) 3 and 9 months after fitting. RESULTS: Both groups had the same improvement related to the speech recognition after nine months of AASI use, and the IOI-HA didn't show any statically significant difference on three and nine months. CONCLUSION: The two strategies of care did not differ, from the clinical point of view, as regards the hearing aid fitting results obtained upon the evaluation of patients in the short and medium term, thus changes in the current model of care should be considered.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: At the initial consultation, the speech-language pathologist and audiologist may consider possible diagnostic hypotheses based on the child's history and the parents' complaint. Aim: To investigate the association of hearing complaints with the findings obtained in the conventional audiologic assessment in children with cleft lip and palate. Retrospective study. Methods: We analyzed medical charts of 1000 patients with cleft lip and palate who underwent surgical repair between 1988 and 1995 at a mean age of 6 years 8 months. We excluded charts with records of inconsistent audiological responses and charts with missing data for any of the audiologic evaluations considered. Thus, the sample consisted of 393 records. Results: Two hundred thirty-nine patients presented hearing loss in one or both ears, but only 3.8% reported hearing complaints. The most frequent were otorrhea followed by otalgia. There was no statistical significance between the complaint and gender (p = 0.26) nor between the complaint and hearing loss (p = 0.83). Conclusion: This study showed no association between the hearing complaint and the conventional audiologic assessment

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening. Aim: To evaluate the TS audiometer for conducting audiometric screening. Methods: A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated. Results: For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively. Conclusions: The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: In recent years, the benefits associated with the use of cochlear implants (CIs), especially with regard to speech perception, have proven to surpass those produced by the use of hearing aids, making CIs a highly efficient resource for patients with severe/profound hearing loss. However, few studies so far have assessed the satisfaction of adult users of CIs. Objective: To analyze the relationship between the level of speech perception and degree of satisfaction of adult users of CI. Method: This was a prospective cross-sectional study conducted in the Audiological Research Center (CPA) of the Hospital of Craniofacial Anomalies, University of São Paulo (HRAC/USP), in Bauru, São Paulo, Brazil. A total of 12 users of CIs with pre-lingual or post-lingual hearing loss participated in this study. The following tools were used in the assessment: a questionnaire, "Satisfaction with Amplification in Daily Life" (SADL), culturally adapted to Brazilian Portuguese, as well as its relationship with the speech perception results; a speech perception test under quiet conditions; and the Hearing in Noise Test (HINT)Brazil under free field conditions. Results: The participants in the study were on the whole satisfied with their devices, and the degree of satisfaction correlated positively with the ability to perceive monosyllabic words under quiet conditions. The satisfaction did not correlate with the level of speech perception in noisy environments. Conclusion: Assessments of satisfaction may help professionals to predict what other factors, in addition to speech perception, may contribute to the satisfaction of CI users in order to reorganize the intervention process to improve the users' quality of life.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Hearing loss (HL) is defined as the complete or partial loss of hearing ability. Aims: To characterize (1) the degree of satisfaction among adult and elderly hearing aid (HA) users who were treated by a public hearing health service and (2) the relationship between satisfaction and the variables of gender, age, degree of HL, and type of HA. Method: The clinical and experimental study included the administration of the Satisfaction with Amplification in Daily Life (SADL) questionnaire to 110 patients who had used HAs for more than 3 months and were 18 years of age or older. Results: Test patients were sex-balanced (48% were women) and had a mean age of 67 years. A relatively high incidence of sensorineural moderate HL was detected in the study patients (66%) and device B was the most commonly used HA type (48%). No significant differences were evident between HA satisfaction and sex. The importance placed on services/costs and personal image varied between age groups. Correlation was evident at all levels between user satisfaction and amplification. Decreased satisfaction was observed in individuals with severe and/or profound HL. The type of HA used yielded statistically significant differences in the positive effects referring. Conclusion: No correlations were evident between the different factors proposed. HA users exhibited high levels of satisfaction in all SADL areas