987 resultados para nutrition assessment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mineral series triplite-zwieselite with theoretical formula (Mn2+)2(PO4)(F)-(Fe2+)2(PO4)(F) from the El Criolo granitic pegmatite, located in the Eastern Pampean Ranges of Córdoba Province, was studied using electron microprobe, thermogravimetry, and Raman and infrared spectroscopy. The analysis of the mineral provided a formula of (Fe1.00, Mn0.85, Ca0.08, Mg0.06)∑2.00(PO4)1.00(F0.80, OH0.20)∑1.00. An intense Raman band at 981 cm−1 with a shoulder at 977 cm−1 is assigned to the ν1 symmetric stretching mode. The observation of two bands for the phosphate symmetric stretching mode offers support for the concept that the phosphate units in the structure of triplite-zwieselite are not equivalent. Low-intensity Raman bands at 1012, 1036, 1071, 1087, and 1127 cm−1 are assigned to the ν3 antisymmetric stretching modes. A set of Raman bands at 572, 604, 639, and 684 cm−1 are attributed to the ν4 out-of-plane bending modes. A single intense Raman band is found at 3508 cm−1 and is assigned to the stretching vibration of hydroxyl units. Infrared bands are observed at 3018, 3125, and 3358 cm−1 and are attributed to water stretching vibrations. Supplemental materials are available for this article. Go to the publisher's online edition of Spectroscopy Letters to view the supplemental file.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report presents observations, findings, and recommendations from an engineering reconnaissance trip following the May 20th, 2013 tornado that struck Moore, Oklahoma. A team of faculty, research scientists, professional engineers, and civil engineering students were tasked with investigating and documenting the performance of critical facility buildings and residences, (IBC Occupancy Category II, III, and IV), in Moore, OK. The Enhanced Fujita (EF) 5 tornado created a 17-mile long damage swath destroying over 12,000 buildings and killing 24 people. The total economic loss from this single event was estimated at $3 billion. The May 20th tornado was the third major tornado to hit Moore in the previous 15 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Randomised controlled trials may be of limited use to evaluate the multidisciplinary and multimodal interventions required to effectively treat complex patients in routine clinical practice; pragmatic action research approaches may provide a suitable alternative. Methods A multiphase, pragmatic, action research based approach was developed to identify and overcome barriers to nutritional care in patients admitted to a metropolitan hospital hip-fracture unit. Results Four sequential action research cycles built upon baseline data including 614 acute hip-fracture inpatients and 30 purposefully sampled clinicians. Reports from Phase I identified barriers to nutrition screening and assessment. Phase II reported post-fracture protein-energy intakes and intake barriers. Phase III built on earlier results; an explanatory mixed-methods study expanded and explored additional barriers and facilitators to nutritional care. Subsequent changes to routine clinical practice were developed and implemented by the treating team between Phase III and IV. These were implemented as a new multidisciplinary, multimodal nutritional model of care. A quasi-experimental controlled, ‘before-and-after’ study was then used to compare the new model of care with an individualised nutritional care model. Engagement of the multidisciplinary team in a multiphase, pragmatic action research intervention doubled energy and protein intakes, tripled return home discharge rates, and effected a 75% reduction in nutritional deterioration during admission in a reflective cohort of hip-fracture inpatients. Conclusions This approach allowed research to be conducted as part of routine clinical practice, captured a more representative patient cohort than previously reported studies, and facilitated exploration of barriers and engagement of the multidisciplinary healthcare workers to identify and implement practical solutions. This study demonstrates substantially different findings to those previously reported, and is the first to demonstrate that multidisciplinary, multimodal nutrition care reduces intake barriers, delivers a higher proportional increase in protein and energy intake compared with baseline than other published intervention studies, and improves patient outcomes when compared with individualised nutrition care. The findings are considered highly relevant to clinical practice and have high translation validity. The authors strongly encourage the development of similar study designs to investigate complex health problems in elderly, multi-morbid patient populations as a way to evaluate and change clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Registered nurses and midwives play an essential role in detecting patients at risk of deterioration through ongoing assessment and action in response to changing health status. Yet, evidence suggests that clinical deterioration frequently goes unnoticed in hospitalised patients. While much attention has been paid to early warning and rapid response systems, little research has examined factors related to physical assessment skills. OBJECTIVES: To determine a minimum data set of core skills used during nursing assessment of hospitalised patients and identify nurse and workplace predictors of the use of physical assessment to detect patient deterioration. DESIGN: The study used a single-centre, cross-sectional survey design. SETTING and PARTICIPANTS: The study included 434 registered nurses and midwives (Grades 5-7) involved in clinical care of patients on acute care wards, including medicine, surgery, oncology, mental health and maternity service areas, at a 929-bed tertiary referral teaching hospital in Southeast Queensland, Australia. METHODS: We conducted a hospital-wide survey of registered nurses and midwives using the 133-item Physical Assessment Skills Inventory and the 58-item Barriers to Registered Nurses’ Use of Physical Assessment scale. Median frequency for each physical assessment skill was calculated to determine core skills. To explore predictors of core skill utilisation, backward stepwise general linear modelling was conducted. Means and regression coefficients are reported with 95% confidence intervals. A p value < .05 was considered significant for all analyses. RESULTS: Core skills used by most nurses every time they worked included assessment of temperature, oxygen saturation, blood pressure, breathing effort, skin, wound and mental status. Reliance on others and technology (F = 35.77, p < .001), lack of confidence (F = 5.52, p = .02), work area (F = 3.79, p = .002), and clinical role (F = 44.24, p < .001) were significant predictors of the extent of physical assessment skill use. CONCLUSIONS: The increasing acuity of the acute care patient plausibly warrants more than vital signs assessment; however, our study confirms nurses’ physical assessment core skill set is mainly comprised of vital signs. The focus on these endpoints of deterioration as dictated by early warning and rapid response systems may divert attention from and devalue comprehensive nursing assessment that could detect subtle changes in health status earlier in the patient's hospitalisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vision-based underwater navigation and obstacle avoidance demands robust computer vision algorithms, particularly for operation in turbid water with reduced visibility. This paper describes a novel method for the simultaneous underwater image quality assessment, visibility enhancement and disparity computation to increase stereo range resolution under dynamic, natural lighting and turbid conditions. The technique estimates the visibility properties from a sparse 3D map of the original degraded image using a physical underwater light attenuation model. Firstly, an iterated distance-adaptive image contrast enhancement enables a dense disparity computation and visibility estimation. Secondly, using a light attenuation model for ocean water, a color corrected stereo underwater image is obtained along with a visibility distance estimate. Experimental results in shallow, naturally lit, high-turbidity coastal environments show the proposed technique improves range estimation over the original images as well as image quality and color for habitat classification. Furthermore, the recursiveness and robustness of the technique allows implementation onboard an Autonomous Underwater Vehicle for improving navigation and obstacle avoidance performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Skin temperature assessment has historically been undertaken with conductive devices affixed to the skin. With the development of technology, infrared devices are increasingly utilised in the measurement of skin temperature. Therefore, our purpose was to evaluate the agreement between four skin temperature devices at rest, during exercise in the heat, and recovery. Methods: Mean skin temperature (T̅sk) was assessed in thirty healthy males during 30 min rest (24.0± 1.2°C, 56 ± 8%), 30 min cycle in the heat (38.0 ± 0.5°C, 41 ± 2%), and 45 min recovery(24.0 ± 1.3°C, 56 ± 9%). T̅sk was assessed at four sites using two conductive devices(thermistors, iButtons) and two infrared devices (infrared thermometer, infrared camera). Results: Bland–Altman plots demonstrated mean bias ± limits of agreement between the thermistors and iButtons as follows (rest, exercise, recovery): -0.01 ± 0.04, 0.26 ± 0.85, -0.37 ± 0.98°C; thermistors and infrared thermometer: 0.34 ± 0.44, -0.44 ± 1.23, -1.04 ± 1.75°C; thermistors and infrared camera (rest, recovery): 0.83 ± 0.77, 1.88 ± 1.87°C. Pairwise comparisons of T̅sk found significant differences (p < 0.05) between thermistors and both infrared devices during resting conditions, and significant differences between the thermistors and all other devices tested during exercise in the heat and recovery. Conclusions: These results indicate poor agreement between conductive and infrared devices at rest, during exercise in the heat, and subsequent recovery. Infrared devices may not be suitable for monitoring T̅sk in the presence of, or following, metabolic and environmental induced heat stress.