301 resultados para multifocal electroretiogram


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare subjective and objective visual performance of the Air Optix Aqua Multifocal lens to monovision in a group of subjects requiring a medium level of reading-addition power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Hepatic epithelioid hemangioendothelioma is a rare malignant tumor of vascular origin with frequent multifocal appearance. Liver resection may cause tumor spread. Liver transplantation has been indicated for unresectable nodules. We hypothesized that adjuvant interferon treatment is effective to prevent metastasis after liver resection. We report a case of multifocal hepatic epithelioid hemangioendothelioma successfully treated with interferon pulse therapy and bilobar hepatic resection.Methodology. CT scan and magnetic resonance imaging diagnosed three nodules in the liver (segments IV, VI and VII). Histopathology and specific immunostaining of a percutaneous nodule biopsy confirmed the diagnosis of hepatic epithelioid hemangioendothelioma. The treatment protocol included daily interferon alpha 2b 9 weeks before and 1 week after resection of liver segments IV, VI and VII.Results. The postoperative outcome was complicated by a self-limited biliary fistula. The patient remains tumor free at 3 years after liver resection and currently enjoys excellent health.Conclusion. Interferon pulse therapy and hepatic resection was a good option to treat multifocal bilobar hepatic epithelioid hemangioendothelioma; it may prevent metastasis dissemination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Melanoacanthoma (MA) has been described in the oral mucosa as a solitary lesion or, occasionally, as multiple lesions. MA mainly affects dark skinned patients and grows rapidly, showing a plane or slightly raised appearance and a brown to black color. The differential diagnosis includes oral nevi, amalgam tattoos, and melanomas. We report here the case of a 58-year-old black woman who presented multiple pigmented lesions on the hard palate. Case presentation. Based on the differential diagnosis of melanoma, a punch biopsy (4 mm in diameter) was performed. The material was fixed in 10% formalin, embedded in paraffin, and stained with hematoxylin-eosin or submitted to immunohistochemical analysis. Immunohistochemistry using antibodies against protein S-100, melan-A, HMB-45, MCM-2, MCM-5, Ki-67 and geminin was performed. Immunohistochemical analysis revealed strong cytoplasmic immunoreactivity of dendritic melanocytes for proteinS-100, HMB-45 and melan-A.Positive staining for proliferative markers (MCM-2, MCM-5, Ki-67) was only observed in basal and suprabasal epithelial cells, confirming the reactive etiology of the lesion. The diagnosis was oral Melanoacanthoma (MA). Conclusion: The patient has been followed up for 30 months and shows no clinical alterations. MA should be included in the differential diagnosis of pigmented lesions of the oral cavity. © 2013 das Chagas e Silva de Carvalho et al.; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m2 mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human poliomavirus is the etiologic agente of Progressive multifocal leukoencephalopathy (PML), a disease characterized by focal lesions not expansives of the central nervous system that develops in imunocompromissed patients, specially people with aids. The main aim of the study was to evalute the prevalence of the JCV excretion in urine samples of patients with aids, without PML, to compare two JCV DNA detection techniques through of two diferents genomic regions and to evaluate the genotypic characterization of the positive samples. A total of 75 samples were colected in the Instituto de Infectologia Emílio Ribas, in Sao Paulo, Brazil, between may and november, 2009. To detect the JC virus it was made the DNA extraction and then the polimerase chain reaction (PCR). Firstly a fragment of 215 bp was amplified, which corresponds to the codifying gene of the strutural protein of de JC vírus capsid VP1. All the samples were later submitted to another PCR that uses a pair of primers complementaries to the early region of the JCV (T antigen) amplifying a fragment of 173 bp. Followed by the digestion of the amplified product with the restriction enzime BamH1, resulting in two smaller fragments (120 bp and 53 bp). The JC vírus was detected in 53 samples, for both techniques (70,7% for VP1 PCR, and the restriction enzime BamH1), 34/46 were men (73,9%) and 19/29 were women (65,5%). The JCV excretion was higher in individuals that were over 46 years old. Regarding the seven genotypes described in the literature, the ones that were more prevalent among the JC positive patients were 3B and 3A with 10 samples each (21,0%), the 2B with 9 samples (19,0%) and genotype 6, with six samples (13,0%). As in the brown patients as the white ones, the most prevalent genotype was 3B. In the present study it was observed a high prevalence of JCV DNA (70,7%) and the genotype 3 (43,0%)... (Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess visual outcomes and patient satisfaction following implantation of the Sulcoflex® multifocal intraocular lens (IOL; Rayner Intraocular Lenses Ltd., Hove, UK) in a procedure combining capsular bag lens implantation with sulcus placement of the Sulcoflex® IOL. Setting: Instituto de Oftalmologia de Assis, Assis, SP, Brazil. Methods: Cataract patients > 45 years, with hyperopia ≥ 1.50 D and potential acuity measurement ≥ 20/30 undergoing Sulcoflex® multifocal IOL implantation were included. Monocular and binocular uncorrected near and distance visual acuity (VA) were evaluated at five days, one month, and three months postoperatively. Contrast sensitivity and refraction were measured in a subset of patients three months postoperatively. Patient satisfaction was assessed one month postoperative. Results: This non-consecutive case series comprised 25 eyes of 13 patients. Eleven eyes (52%) had pre-existing retinal pathologies. Monocular distance VA improved significantly at all follow-up visits. At final follow-up, 88% of eyes had monocular uncorrected distance VA (UDVA) of at least 20/25 and 24% had monocular UDVA of 20/20. All eyes had binocular UDVA of at least 20/25, and 58% had binocular UDVA of 20/20. Monocular uncorrected near vision (UNVA) was J1 in 68% of eyes and all patients had binocular UNVA of J1. Of all eyes studied, 92% and 58% achieved a spherical equivalent within 1 D and −0.5 D, respectively. The majority of patients reported satisfaction with visual outcomes. Complications included a postoperative intraocular pressure spike in four eyes. Conclusion: The Sulcoflex® multifocal IOL improves near and distance VA in cataract patients with retinal abnormalities and good VA potential.