981 resultados para liquid-chromatography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An electrochemical detector which was constracted by using a carbon fibre electrode in a flow-through cell was connected with a liquid chromatographic column. Thus a sensitive,

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two methods for tetrodotoxin analysis using liquid chromatography coupled with electrospray iontrap mass spectrometry (LC-ESI-MS) have been established with C,, reversed phase column and hydrophilic interaction liquid chromatography (HILIC) column, respectively. Sensitivity and reproducibility of the methods were compared. The method using C-18 column in selected ion monitoring (SIM) mode had a detection limit (S/N = 3) of 120 pg, and a good linearity of the calibration curve was obtained for tetrodotoxin (r = 0. 9992). High reproducibility of the method was observed, with a relative standard deviation (RSD) below 10%. The method using HILIC column in SIM mode and selected reaction monitoring (SRM) mode had detection limits (S/N = 3) of 15 and 3.75 pg, respectively. Good linearity of the calibration curves was obtained for tetrodotoxin (r = 0. 9996 and 0. 9998 in SIM and SRM mode, respectively). T he reproducibility was high in SIM mode but relatively poor in SRM mode. Based on the results, the method using HILIC column in SIM mode was suggested for the analysis of tetrodotoxin with LC-MS system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The hyphenated technique of high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) was applied to the simultaneous determination of five organotin compounds (trimethyltin, dibutyltin, tributyltin, diphenyltin and triphenyltin) in seawater samples. Agilent TC-C18 column was used for the separation, the mobile phase of HPLC was CH3CN : H2O: CH3COOH=65 : 23 : 12 (phi), 0.05% TEA, and pH value was adjusted to 3.0 by diluent ammonia. The flow rate was 0.6 mL . min(-1). Five mixed organotin compounds in a mix standard solution from 100 to 0.5 mu g . L-1 were applied for the method assessment. The experimental results indicate that the correlation coefficient of calibration curves (R-2) for each organotin compound was over 0.998 and the detection limits of the five organotin compounds were lower than 3 ng . L-1. Different mixed organic solvents including dichloromethane or toluene were used for extraction of organotin and the extraction condition of organotin from seawater was optimized. The 100 mL seawater acidized by hydrochloric acid was extracted by 10 mL carbon dichloride (CH2Cl2) with 2% tropolone for 10 min twice. Extracted organic solvents were mixed And blown to one drop by nitrogen with the rate of 1.7 mL . min(-1), then 1 mL acetonitrile was added to the drop for redissolving the organotin compounds. Finally, the mixed redissolution was filtered by 0.22 mu m organic filter membrane before analysis. it was found that the only organotin compound in seawater was triphenyltin (TPHT) and the content was 53.2 ng . L-1. The recoveries test from the standard addition for diphenyltin (DPHT), dibutyltin (DBT), tributyltin (TBT) and triphenyltin (TPHT) were over 80%. However, the recovery for trimethyltin (TMT) was relatively low and the value was 50%. The reason might be attributed to the decomposition or adsorption of those compounds during the extraction procedure. Further study on this subject is in progress.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The hyphenated technique of high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry(HPLC-ICP-MS) was applied to the simultaneous determination of five organotin compounds in the shellfish samples. Agilent TC-C-18 column was selected, mobile phase of the HPLC was CH3CN:H2O: CH3COOH = 65:23:12 (V/V), 0. 05% TEA, pH = 3.0 at flow rate 0.4 mL/min. Five mixed organotin standards from 100 mu g/L to 0. 5 mu g/L was used for the method evaluation. The experimental results indicate that the linearity (R-2) for each compound was over 0.998. The shellfish samples were treated by supersonic extraction with mobile phase for 30min. Four organotin compounds including dibutyltin (DBT), tributyltin (TBT), diphenyltin (DphT) and triphenyltin (TPhT) in shellfish samples were detected with method mentioned above. It was found that the domain compounds in the samples were tributyltin (TBT) and triphenyltin (TPhT). The recoveries test from the standard addition for trimethyltin (TMT tributyltin (TBT), and triphenyltin (TPhT) were, over 80%. However, the recoveries for diphenyltin (DPhT) and dibutyltin (DBT) were relatively low, 37.3% and 75.2% respectively. The reason might be attributed to the decomposition of those compounds during the extraction procedure. The further study on this subject is under the progress.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

On a reversed phase Hypersil BDS C-18 (200 mm x 4. 6 mm, 5 mu m) column, 20 amino acids, which were derivatized using 2-(11H-benzo [a] carbazol-11-yl) ethyl carbonochloridate (BCEC-Cl) as pre-column derivatization reagent, were separated in conjunction with a gradient elution. Optimum derivatization was obtained by reacting of amino acids with BCEC-Cl at room temperature for 5 min in the presence of sodium borate catalyst in acetonitrile solvent. The fluorescence excitation and emission wavelengths were 279 nm and 380 nm respectively. The identification of amino acid derivatives from hydrolyzed bovine serum albumin and bee pollen was carried out by post-column mass spectrometry with electrospray ion source in positive ion mode. Linear correlation coefficients of the amino acid derivatives were > 0.9990, and detection limits (at signal to noise of 3:1) were 1.49 - 19.74 fmol for the labeled amino acids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel, simple and accurate fingerprint method was developed using high-performance liquid chromatography-photodiode array detection (HPLC-DAD) for the quality control of Qianghuo, a Tibetan folk and Chinese herbal medicine used as a diaphoretic, an antifebrile and an anodyne. For the first time, the feasibility and advantages of employing chromatographic fingerprint were investigated and demonstrated for the evaluation of Qianghuo by systematically comparing chromatograms of aqueous extracts with the professional analytical software recommended by State Food and Drug Administration (SFDA). Our results revealed that the chromatographic fingerprint combing similarity evaluation could efficiently identify and distinguish raw herbs of Qianghno from different sources and different species. The effects on Notopterygium forbesii Boiss (Apiaceae) chromatographic fingerprints resulted from collecting locations, harvesting time were also examined. (c) 2006 Elsevier lrelanc Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC-HCI) as the dehydrant with fluorescence detection has been developed. Amines were derivatized to their acidamides with labeling reagent 2-(2-phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA). Studies on derivatization conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum at lambda(ex) 260nm and an emission maximum at lambda(em) 380nm. The labeled derivatives exhibited high stability and were enough to be efficiently analyzed by high-performance liquid chromatography. Identification of derivatives was carried out by online post-column mass spectrometry (LC/APCI-MS/MS) and showed an intense protonated molecular ion corresponding m/z [MH](+) under APCI in positive-ion mode. At the same time, the fluorescence properties of derivatives in various solvents or at different temperature were investigated. The method, in conjunction with a gradient elution, offered a baseline resolution of the common amine derivatives on a reversed-phase Eclipse XDB-C-8 column. LC separation for the derivatized amines showed good reproducibility with acetonitrile-water as mobile phase. Detection limits calculated from 0.78 pmol injection, at a signal-to-noise ratio of 3, were 3.1-18.2 fmol. The mean intra- and inter-assay precision for all amine levels were < 3.85% and 2.11%, respectively. Excellent linear responses were observed with coefficients of > 0.9996. The established method for the determination of aliphatic amines from real wastewater and biological samples was satisfactory. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pre-column derivatization method for the sensitive determination of amino acids and peptides using the tagging reagent 1,2-benzo-3,4dihydrocarbazole-9-ethyl chloroformate (BCEOC) followed by high-performance liquid chromatography with fluorescence detection has been developed. Identification of derivatives was carried out by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS/MS). The chromophore of 2-(9-carbazole)-ethyl chloroformate (CEOC) reagent was replaced by 1,2-benzo-3,4-dihydrocarbazole functional group, which resulted in a sensitive fluorescence derivatizing reagent BCEOC. BCEOC can easily and quickly label peptides and amino acids. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography. The derivatives showed an intense protonated molecular ion corresponding m/z (M + H)(+) under electrospray ionization (ESI) positive-ion mode with an exception being Tyr detected at negative mode. The collision-induced dissociation of protonated molecular ion formed a product at m/z 246.2 corresponding to the cleavage of C-O bond of BCEOC molecule. Studies on derivatization demonstrate excellent derivative yields over the pH 9.0-10.0. Maximal yields close to 100% are observed with a 3-4-fold molar reagent excess. Derivatives exhibit strong fluorescence and extracted detzvatization solution with n-hexane/ethyl acetate (10:1, v/v) allows for the direct injection with no significant interference from the major fluorescent reagent degradation by-products, such as 1,2-benzo-3,4-dihydrocarbazole-9-ethanol (BDC-OH) (a major by-product), mono- 1,2-benzo-3,4-dihydrocarbazole-9-ethyl carbonate (BCEOC-OH) and bis-(1,2-benzo-3,4-dihydrocarbazole-9-ethyl) carbonate (BCEOC)(2). In addition, the detection responses for BCEOC derivatives are compared to those obtained with previously synthesized 2-(9-carbazole)-ethyl chloroformate (CEOC) in our laboratory. The ratios AC(BCEOC)/AC(CEOC) = 2.05-6.51 for fluorescence responses are observed (here, AC is relative fluorescence response). Separation of the derivatized peptides and amino acids had been optimized on Hypersil BDS C-18 column. Detection limits were calculated from 1.0 pmol injection at a signal-to-noise ratio of 3, and were 6.3 (Lys)-177.6 (His) fmol. The mean interday accuracy ranged from 92 to 106% for fluorescence detection with mean %CV < 7.5. The mean interday precision for all standards was < 10% of the expected concentration. Excellent linear responses were observed with coefficients of > 0.9999. Good compositional data could be obtained from the analysis of derivatized protein hydrolysates containing as little as 50.5 ng of sample. Therefore, the facile BCEOC derivatization coupled with mass spectrometry allowed the development of a highly sensitive and specific method for the quantitative analysis of trace levels of amino acids and peptides from biological and natural environmental samples. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper proposes the identification method of linear and non-linear chromatographic system. The non-linear isotherms and lumped mass transfer coefficients of chromatography separating sorbitol and mannitol are determined. And the theoretical elution curves calculated by non-linear chromatographic model are more accurate than those calculated by linear chromatographic model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is an urgent need for thorough analysis of Radix astragali, a widely used Chinese herb, for quality control purposes. This paper describes the development of a total analytical method for Radix astragali extract, a multi-component complex mixture. Twenty-four components were separated step by step from the extract using a series of isocratic isopropanol-methanol elutions, and then 42 components were separated similarly using methanol-water elutions. Based on the log k(w) and -S of the 66 components obtained from the above procedure and the optimization software developed in our laboratory, an optimum elution program consisting of seven methanol-water segments and four isopropanol-methanol segments was developed to finish the task of analyzing the total components in a single run. Under optimized gradient conditions, the sample of Radix astragali extract was analyzed. As expected, most of the components were well separated and the experimental chromatogram was in a good agreement with the predicted one.