161 resultados para ionophore


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conceptual advances in the field of membrane transport have, in the main, utilized artificial membranes, both planar and vesicular. Systems of biological interest,viz., cells and organelles, resemble vesicles in size and geometry. Methods are, therefore, required to extend the results obtained with planar membranes to liposome systems. In this report we present an analysis of a fluorescence technique, using the divalent cation probe chlortetracycline, in small, unilamellar vesicles, for the study of divalent cation fluxes. An ion carrier (X537 A) and a pore former (alamethicin) have been studied. The rate of rise of fluorescence signal and the transmembrane ion gradient have been related to transmembrane current and potential, respectively. A second power dependence of ion conduction-including the electrically silent portion thereof — on X537 A concentration, has been observed. An exponential dependence of ldquocurrentrdquo on ldquotransmembrane potentialrdquo in the case of alamethicin is also confirmed. Possible errors in the technique are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The circular dichroism studies on calcium ionophore, A23187, incorporated in Dipalmitoyl phosphatidyl choline (DPPC) vesicle showed interesting time dependent changes in the CD spectra. Analysis of the data indicated the possible aggregation of the observed dimeric structure of this molecule in non-polar solvents into a stacked dimeric pore in the phospholipid vesicle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The circular dichroism, fluorescence, Nuclear Magnetic Resonance and BLM conductance studies indicate that A23187 forms a stable complex with amino acids at low ionophore concentrations (<10(-4)M). However, A23187 prefers to be in a dimeric structure with no significant binding to amino acids, at concentrations higher than 10(-4)M. It was also observed that at lower concentrations, at which the amino acids bind to the ionophore, the affinity for calcium ions was several orders of magnitude lower than that at higher ionophore concentrations. We have also conducted molecular modeling studies to examine the structure of the A23187 dimer and its amino acid complexes. The results of these modeling studies strongly support our experimental results and validate the formation of a hydrogen bonded and energetically stable A23187 dimer and its amino acid complexes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ion transport across phospholipid vesicles was studied by 7Li and 23Na-NMR using an aqueous anionic paramagnetic shift reagent, dysprosium nitrilotriacetate [Dy(NTA)2]3?, mediated by ionophores, lasalocid A and A23187. The intra- and extracellular 7Li and 23Na-NMR signals were well separated (20?Hz) at mM concentration of the shift reagent. The observed data on the rate constant for lithium transport across DPPC vesicles at various concentrations of the ionophores indicated that lasalocid A is a more efficient carrier for lithium ion compared with the sodium ion transport by this ionophore, while A23187 was not specific to either of the ions (Li or Na). ©1998 European Peptide Society and John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A number of acrosome reaction (AR) initiators have been found to be effective in inducing AR of human, laboratory and domestic animal sperm. Using an improved simple fluorescence microscopy, effects of gamma-aminobutyric acid (GABA), progesterone and ionophore A23187 on sperm AR of tree shrew, a useful animal model in biomedical research, have been investigated. Spontaneous AR in 4.92-7.53% of viable sperm was observed. Complete AR in 10.31-18.25% of viable tree shrew sperm was obviously induced by 5 mu M and 10 mu M calcium ionophore A23187, 1 mM GABA, and 5 mu M progesterone, and there were no significant differences between their abilities to initiate complete AR. No significant differences of AR percentages between 1- and 2-h treatments with A23187, progesterone and/or GABA were observed. These results suggested that the responses of tree shrew sperm to these AR initiators are similar to that of human and other mammalian sperm. (C) 1997 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PVC based membranes of a double armed crown ether, N, N'-dibenzyl, 1,4,10,13-tetraoxa-7, 16-diaza cyclooctadecane (I) as ionophore with sodium tetra phenyl borate (NaTPB) as anion excluder and with many plasticizing solvent mediators have been prepared and used for Hg(II) ion determination. The membrane with DBBP (dibutyl butyl phosphonate ) as plasticizer with various ingredients in the ratio PVC: I: NaTPB: DBBP (150: 12: 2: 100) shows the best results in terms of working concentration range (3.1x10-5-1.0x10-tM) with a Nernstian slope (29.0′0.5 mV/decade of activity). The electrode works in the pH range 2.1-4.5. The response time of the sensor is 15s and it can be used for about 4 months in aqueous as well as in non-aqueous medium. It has good stability and reproducibility. The potentiometric selectivity coefficient values for mono-, di-, and trivalent cations are tabulated. The sensor is highly selective for Hg2+ in the presence of normal interferents like cadmium, silver, sodium and iron.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The H+, Li+, Na+, K+, Mg2+, Ca2+ and Ba2+ ion transfer across the water/nitrobenzene (NB) and water/1,2-dichloroethane (DCE) interfaces, facilitated by the ionophore ETH157, has been investigated by cyclic voltammetry (CV). The mechanism of the transfer process has been discussed, and the diffusion coefficients and the stability constants of the complexes formed in the nitrobenzene phase have been determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Nafion/ionophore, 4-tert-butylcalix[4]arene-tetrakis(N,N-dimethylthioacetamide) composite coated and bismuth film modified glassy carbon electrode. (GC/NA-IONO/BiFE) was described to determine trace lead sensitively and selectively. The characteristics of such modified GC/NA-IONO/BiFE were studied by scanning electron microscopy and cyclic voltammetry. The influence of various experimental parameters upon the stripping lead signal at the GC/NA-IONO/BiFE was explored. Under the optimized conditions, the differential pulse voltammetric stripping response is highly linear over the 0.1-8.0 nM lead range examined (180s preconcentration at -1.2V), with a detection limit of 0.044nM and good precision (RSD=5.4% at 0.5nM). Also applicability to seawater samples was demonstrated at such modified electrode. The high selectivity of ionophore coupled with the excellent electrochemical characteristics of bismuth endow the GC/NA-IONO/BiFE a promising and robust tool for monitoring of trace lead rapidly and precisely.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carnitine (CRT) is a biological metabolite found in urine that contributes in assessingseveral disease conditions, including cancer. Novel quick screening procedures for CRT are therefore fundamental. This work proposes a novel potentiometric device where molecularly imprinted polymers (MIPs) were used as ionophores. The host-tailored sites were imprinted on a polymeric network assembled by radical polymerization of methacrylic acid (MAA) and trimethylpropane trimethacrylate (TRIM). Non-imprinted polymers (NIPs) were produced as control by removing the template from the reaction media. The selective membrane was prepared by dispersing MIP or NIP particles in plasticizer and poly(vinyl chloride), PVC, and casting this mixture over a solid contact support made of graphite. The composition of the selective membrane was investigated with regard to kind/amount of sensory material (MIP or NIP), and the need for a lipophilic additive. Overall, MIP sensors with additive exhibited the best performance, with near-Nernstian response down to ~ 1 × 10− 4 mol L− 1, at pH 5, and a detection limitof ~ 8 × 10− 5 mol L− 1. Suitable selectivity was found for all membranes, assessed by the matched potential method against some of the most common species in urine (urea, sodium, creatinine, sulfate, fructose and hemoglobin). CRT selective membranes including MIP materials were applied successfully to the potentiometric determination of CRT in urine samples.