984 resultados para intermittent recovery test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Yo-Yo Intermittent Recovery (IR) Test is currently used to assess endurance performance in team sport athletes. However, to date, no data has been presented on its application to an elite junior Australian football (AF) playing group. Therefore, the aim of this study was to evaluate the Yo-Yo Intermittent Recovery Test Level 1 (IR1) ability to discriminate between junior AF players at two different playing standards and a group of non-athletic healthy males. Sixty age matched participants (16.6 ± 0.5 years) spread over three groups (20 per group): elite junior footballers; sub-elite junior footballers; and non-athletic healthy males participated in this study. Participants undertook a single Yo-Yo test performance on an indoor basketball court for each group. A one-way ANOVA with Scheffe's post hoc analysis revealed the elite junior footballers covered a significantly greater total distance (p < 0.001) and completed a significantly greater number of high-intensity efforts (p < 0.001) in comparison to their sub-elite counterparts, whilst both AF groups performed significantly better (p < 0.001) than the non-athletic healthy males. This study demonstrates the ability of the Yo-Yo IR1 to discriminate endurance performance between elite and sub-elite AF players, whilst further distinguishing AF players from a non-athletic healthy control group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Futbolean egoten ari den garapenarekin bat, indibidualizaziorako joera ezartzen ari da futbolean, postu espezifiko bakoitzaren beharren arabera entrenatzaile zein prestatzaile fisikoek entrenamendu prozesuak egokituz. Ikerlan honen helburu nagusia zelaiko postu espezifikoen arteko ezberdintasunak aztertzea izango da azelerazio gaitasunean, trebetasunean, behe gorputz adarreko indar elastiko esplosiboan eta ahalmen aerobikoan denboraldiko bi une ezberdinetan. Horrez gain, jokalariek bi une ezberdinen artean izandako bilakaera aztertuko da. 16-20 urte bitarteko 37 jokalarik parte hartu dute ikerketan, hurrengo postuetan sailkatuz: erdiko atzelariak (EA), hegaleko atzelariak (HA), erdilariak (ERD), hegaleko erdilariak (HEG) eta aurrelariak (AUR). 15m linealeko lasterketa, Barrow test egokitua, kontra mugimenduzko jauzi bertikala beso askeekin eta Yoyo intermittent recovery test Level 1 proba fisikoak burutu ziren aurredenboraldiko lehen astean (T1) eta gabonetako lehiaketa etenaren osteko astean (T2). Jokalariak orokorrean aztertuta trebezian eta ahalmen aerobikoan izan zituzten ezberdintasun adierazgarriak bi proba fisiko aldien artean. Postuen arteko ezberdintasunei dagokionez, azelerazio gaitasunean, trebetasunean eta ahalmen aerobikoan aztertu ziren ezberdintasun adierazgarriak lehenengo proba fisiko aldian. Bigarren proba fisiko aldian berriz soilik trebetasunean aztertu ziren ezberdintasun adierazgarriak postuen artean. Denboraldian zehar izandako bilakaerak ere aztertu dira, postuen artean ezberdintasunik egon gabe proba batean ere ez. Esan beharra dago formazioko adinetan jokalariak postu ezberdinetan jokatu ahal izatea bilatzen dela, hori dela eta, ez dute postu batekiko espezializazioa izango. Interesgarria izan daiteke, formazioko aldi honetatik aurrera prestatzaile fisiko eta entrenatzaileentzat, postu espezifiko bakoitzeko jokalariei entrenamendu espezifikoak ezartzea, postu bakoitzaren behar fisiko zein tekniko-taktiko espezifikoetan hobekuntza nabariagoak izateko helburuarekin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study is to analyse the influence of different large-sided games (LSGs) on the physical and physiological variables in under-12s (U12) and -13s (U13) soccer players. The effects of the combination of different number of players per team, 7, 9, and 11 (P7, P9, and P11, respectively) with three relative pitch areas, 100, 200, and 300 m(2) (A100, A200, and A300, respectively), were analysed in this study. The variables analysed were: 1) global indicator such as total distance (TD); work:rest ratio (W:R); player-load (PL) and maximal speed (V-max); 2) heart rate (HR) mean and time spent in different intensity zones of HR (<75%, 75-84%, 84-90% and >90%), and; 3) five absolute (<8, 8-13, 13-16 and >16 Km h(-1)) and three relative speed categories (<40%, 40-60% and >60% V-max). The results support the theory that a change in format (player number and pitch dimensions) affects no similarly in the two players categories. Although it can seem that U13 players are more demanded in this kind of LSG, when the work load is assessed from a relative point of view, great pitch dimensions and/or high number of player per team are involved in the training task to the U12 players. The results of this study could alert to the coaches to avoid some types of LSGs for the U12 players such as:P11 played in A100, A200 or A300, P9 played in A200 or A300 and P7 played in A300 due to that U13>U12 in several physical and physiological variables (W:R, time spent in 84-90% HRmax, distance in 8-13 and 13-16 Km h(-1) and time spent in 40-60% V-max). These results may help youth soccer coaches to plan the progressive introduction of LSGs so that task demands are adapted to the physiological and physical development of participants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En el presente trabajo, las jugadoras de fútbol de la categoría Sub-13 fueron sometidas a diferentes pruebas de valoración a lo largo de la temporada 2013/2014 con el objetivo de determinar su condición biológica y además, conocer la evolución de su rendimiento deportivo y de su salud. Para dar cumplimiento a estos objetivos, se plantearon una serie de pruebas que permitiesen valorar la condición motora y fisiológica. Siguiendo ese orden, fueron medidas utilizando el Yo-Yo Intermittent Recovery Test 1 (resistencia), Counter Movement Jump (fuerza explosiva), test de velocidad de 30 metros lanzados, Zig-Zag Run Test (agilidad) y goniometría de cadera (flexibilidad). La muestra estuvo conformada por 11 niñas que practican fútbol durante 1 hora 2 días a la semana y con rangos de edad entre 12 y 13 años.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Los objetivos de este estudio fueron analizar las diferencias en las características antropométricas, resistencia aeróbica, temperatura corporal y percepción subjetiva del esfuerzo en futbolistas de distintas categorías (cadete y juvenil), y examinar la relación existente entre las distintas variables analizadas. Para ello participaron 37 jóvenes futbolistas, 20 de ellos cadetes (15,12 ± 0,69 años) y 17 juveniles (16,94 ± 0,89 años). A los futbolistas se les midió la talla y la masa corporal, calculándose el índice de masa corporal (IMC). A su vez, para determinar su resistencia aeróbica, los jugadores realizaron el Yo-Yo Intermittent Recovery Level 1, registrándose la distancia total recorrida, la temperatura pre y post-test y la percepción subjetiva del esfuerzo (RPE). Los futbolistas de categoría juvenil obtuvieron mayores valores de masa corporal e IMC, obteniendo además mejores valores en el test de resistencia que los cadetes. Asimismo, se registraron diferencias en el RPEmus y RPEmus-TL, siendo mayor el de los juveniles en ambos casos. Para acabar, se observaron correlaciones altas entre los resultados del test de resistencia y el RPEres-TL, así como con el RPEmus-TL en los juveniles, mientras que en el caso de los cadetes solo correlacionó con el RPEres-TL. Se cree que dichas diferencias pueden ser debidas al mayor desarrollo muscular de los juveniles respecto a los cadetes, aunque se necesitan más estudios.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: This study investigated the efficacy of an intermittent critical power model, termed the "work-balance" (W'BAL) model, during high-intensity exercise in hypoxia. METHODS: Eleven trained, male cyclists (mean ± SD; age 27 ± 6.6 yr, V[Combining Dot Above]O2peak 4.79 ± 0.56 L.min) completed a maximal ramp test and a 3 min "all-out" test to determine critical power (CP) and work performed above CP (W'). On another day an intermittent exercise test to task failure was performed. All procedures were performed in normoxia (NORM) and hypoxia (HYPO; FiO2 ≈ 0.155) in a single-blind, randomized and counter-balanced experimental design. The W'BAL model was used to calculate the minimum W' (W'BALmin) achieved during the intermittent test. W'BALmin in HYPO was also calculated using CP + W' derived in NORM (N+H). RESULTS: In HYPO there was an 18% decrease in V[Combining Dot Above]O2peak (4.79 ± 0.56 vs 3.93 ± 0.47 L.min ; P<0.001) and a 9% decrease in CP (347 ± 45 vs 316 ± 46 W; P<0.001). No significant change for W' occurred (13.4 ± 3.9 vs 13.7 ± 4.9 kJ; P=0.69; NORM vs HYPO). The change in V[Combining Dot Above]O2peak was significantly correlated with the change in CP (r = 0.72; P=0.01). There was no difference between NORM and HYPO for W'BALmin (1.1 ± 0.9 kJ vs 1.2 ± 0.6 kJ). The N+H analysis grossly overestimated W'BALmin (7.8 ± 3.4 kJ) compared with HYPO (P<0.001). CONCLUSION: The W'BAL model produced similar results in hypoxia and normoxia, but only when model parameters were determined under the same environmental conditions as the performance task. Application of the W'BAL model at altitude requires a modification of the model, or that CP and W' are measured at altitude.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this study, we report the effects of ferricyanide on organisms based on the changes in physiological state and morphology of Escherichia coli (E coli) DH 5 alpha after being pretreated by ferricyanide. The impact on bacterial cell growth and viable rate of exposure to different concentrations of ferricyanide was determined, and the morphology change of E. coli was studied by atomic force microscopy (AFM). Finally, recovery test was used to evaluate the recovery ability of injured cells. The results showed that the effects on growth and morphology of E. coli were negligible when the concentration of ferricyanide was below 25.0 mM. While the results showed 50.8% inhibition of growth in the presence of 50.0 mM ferricyanide for 3 h, 89.6% viability was detected by flow cytometry (FCM) assay. AFM images proved that compact patches appeared on the bacterial surface and protected the bacterial viability. Furthermore, the results revealed that deterioration of bacterial surface closely related to the incubation time from 0.5 to 3 h at 100.0 mM ferricyanide. In the recovery test, microbial cell population and dissolved oxygen individually decreased 36.7% and 28.3% with 25.0 mM ferricyanide.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Using a solid phase extraction mini-column home-made from a neutral extractant Cyanex 923, inorganic Hg could be on-line preconcentrated and simultaneously separated from methyl mercury. The preconcentrated Hg (11) was then eluted with 10% HNO3 and subsequently reduced by NaBH4 to form Hg vapor before determination by cold vapor atomic absorption spectrometry (CVAAS). Optimal conditions for and interferences on the Hg preconcentration and measurement were at 1% HCl, for a 25 mL sample uptake volume and a 10 mL min(-1) sample loading rate. The detection limit was 0.2 ng L-1 and much lower than that of conventional method (around 15.8 ng L-1). The relative standard deviation (RSD) is 1.8% for measurements of 40 ng L-1 of Hg and the linear working curve is from 20 to 2000 ng L-1 (with a correlation coefficient of 0.9996). The method was applied in determination of inorganic Hg in city lake and deep well water (from Changchun, Jilin, China), and recovery test results for both samples were satisfactory.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, a method was established for the determination of impurities in high purity tellurium by inductively coupled plasma mass spectrometry (ICP-MS) after Fe(OH)(3) coprecipitation. After comparison of coprecipitation ability and separation efficiency between Fe(OH), and Al(OH)(3), Fe(OH)(3) was chosen as the precipitate. A separation factor of 160 for 200 mg tellurium was obtained under conditions of pH 9 and 2 mg of Fe3(+). The 13 elements, such as Bi, Sn, Pb, In, Tl, Cd, Cu, Co, Ni, Zn, Ti, Be and Zr, could be almost completely coprecipitated under these conditions. In addition, Te memory effect imposed on the ICP-MS instrument was assessed, as well as Te matrix effect that caused the low recovery of Ga, As, Sb and V in real sample was discussed. Finally, the method was evaluated through recovery test and was applied to practical sample analysis, with detection limits of most of the elements being below 0.15 mug g(-1) and R.S.D. below or at approximately 10%, which indicated that this method could fully satisfy the requirements for analysis of 99.999% similar to 99.9999% high purity Te.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Solder pastes and isotropic conductive adhesives (ICAs) are widely used as a principal bonding medium in the electronic industry. This study investigates the rheological behaviour of the pastes (solder paste and isotropic conductive adhesives) used for flip-chip assembly. Oscillatory stress sweep test are performed to evaluate solid characteristic and cohesiveness of the lead-free solder pastes and isotropic conductive adhesive paste materials. The results show that the G' (storage modulus) is higher than G '' (loss modulus) for the pastes material indicating a solid like behaviour. It result shows that the linear visco-elastic region for the pastes lies in a very small stress range, below 10 Pa. in addition, the stress at which the value of storage modulus is equal to that of loss modulus can be used as an indicator of the paste cohesiveness. The measured cross-over stress at G'=G '' shows that the solder paste has higher stress at G'=G '' compared to conductive adhesives. Creep-recovery test method is used to study the slump behaviour in the paste materials. The conductive adhesive paste shows a good recovery when compared to the solder pastes. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose – The purpose of this paper is to develop a quality control tool based on rheological test methods for solder paste and flux media. Design/methodology/approach – The rheological characterisation of solder pastes and flux media was carried out through the creep-recovery, thixotropy and viscosity test methods. A rheometer with a parallel plate measuring geometry of 40mm diameter and a gap height of 1mm was used to characterise the paste and associated flux media. Findings – The results from the study showed that the creep-recovery test can be used to study the deformation and recovery of the pastes, which can be used to understand the slump behaviour in solder pastes. In addition, the results from the thixotropic and viscosity test were unsuccessful in determining the differences in the rheological flow behaviour in the solder pastes and the flux medium samples. Research limitations/implications – More extensive rheological and printing testing is needed in order to correlate the findings from this study with the printing performance of the pastes. Practical implications – The rheological test method presented in the paper will provide important information for research and development, quality control and production staff to facilitate the manufacture of solder pastes and flux media. Originality/value – The paper explains how the rheological test can be used as a quality control tool to identify the suitability of a developmental solder paste and flux media used for the printing process.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rheological properties of solder pastes are very important for a high quality surface mount technology process. The stencil/screen printing process of solder pastes is one of the most critical steps in the SMT assembly process, as most of the assembly defects can often be shown to originate from paste rheology and associated poor printing performance. This paper concerns an investigation of the effect of solder paste composition on the rheological properties and behaviour of four different solder pastes. We report on the evaluation of three different paste formulations based on the no-clean flux composition, with different alloy composition, metal content and particle size using a range of rheological characterisation techniques - including viscosity measurements, yield stress, oscillatory and creep-recovery tests. Our results show that in the viscosity test, all solder pastes exhibited a shear thinning behaviour in nature with different highest maximum viscosity. In the region of shear thinning behaviour the paste 3 delivered the best results. Viscosity test helps to understand the solid and cohesive behaviour of solder pastes. Good solid and cohesive behaviour indicates a good paste roll and helps to avoid paste bleeding. The yield stress test has been used to study the effect of temperature on the flow behaviour of solder pastes. Yield stress was measured for a range of temperature from 15deg C to 35deg C with an increment of 5degC. The result indicated a decreasing of the yield stress point if the temperature was increased. Paste 4 has shown the minimum dependence on temperature. The oscillatory test has been used to find out the linear visco-elastic range and to study the solid and liquid like behaviours of solder pastes. Paste 1 indicated the biggest linear visco-elastic region (LVR) and the highest value of G' and G" which means solder paste 1 will be needed a higher squeegee pressure in the printing process. In the creep recovery test paste 4 showed the best- - recovery and the lowest values of creep and recovery compliance which indicated a good printing behaviour. The test also has showed the solder paste with smaller particle size exhibit less recovery

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PVC supported liquid membrane and carbon paste potentiometric sensors incorporating an Mn(III)-porphyrin complex as a neutral host molecule were developed for the determination of paracetamol. The measurements were carried out in solution at pH 5.5. Under such conditions paracetamol exists as a neutral molecule. The mechanism of molecular recognition between the Mn(III)-porphyrin and paracetamol, leading to potentiometric signal generation, is discussed.The sensitivity and selectivity toward paracetamol of carbon paste and polymeric liquid membrane electrodes incorporating an Mn(III)-porphyrin host were compared. The applicability of these sensors to the direct determination of paracetamol was checked by performing a recovery test in human plasma.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

condições de saúde são questões que precisam ser investigadas na nossa sociedade. Diante da inexistência de estudos que abordem os aspectos psicológicos e físicos desses profissionais, tornou-se necessário e relevante esta investigação para a área de segurança pública num contexto multidisciplinar. O estudo objetivou verificar as características da aptidão física e psicológica relacionada à saúde de policiais militares do Batalhão de Atividades Policiais Especiais (BOPE), da Polícia Militar do Rio Grande do Norte. A amostra selecionada de forma aleatória foi composta de 64 militares de diferentes graduações, do sexo masculino com idade média de 26,2±2,6 anos. Foram utilizados como instrumentos de medida o Questionário de Saúde Geral de Goldberg para avaliar a saúde geral; uma balança digital da marca Techline®, e estadiômetro portátil da marca Sanny® para avaliar a massa corporal e a estatura; fita antropométrica metálica Sanny® para avaliar a perimetria (circunferência do braço contraído, circunferência da panturrilha); paquímetro Sanny® para avaliar os diâmetros ósseos (bi-epicondilar umeral e bi-epicodilar femural); adipômetro Harpender® para avaliar a espessura das dobras cutâneas; dinamômetro manual Jamar para avaliar a força de preensão manual; flexímetro Sanny®, fotocélulas CEFISE modelo Speed Test Fit e o YoYo Intermitent Recovery Test para avaliar o desempenho físico ( flexibilidade, agilidade, velocidade e endurance anaeróbica). Os participantes apresentaram valores elevados para risco de distúrbio ou mesmo a presença de distúrbio, no que se refere à saúde geral; o grupo estudado é classificado como mesoendomorfico, predominando características de endurance aeróbico e anaeróbico e força que foram relacionadas com os aspectos psicológicos. O perfil somatotípico meso-endomorfo parece interferir nos elevados riscos de distúrbios psicológicos advindos da atividade laboral exigida, apesar dos mesmos apresentarem um bom desempenho físico

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Embora a análise no domínio da freqüência do sinal eletromiográfico (EMG) seja empregada na caracterização do processo de fadiga muscular localizada, sua aplicação, especificamente a da freqüência mediana (Fmed), é pouco explorada no âmbito esportivo. O objetivo do presente estudo foi verificar a viabilidade da aplicação do sinal EMG, através de sua análise no domínio da freqüência, como parâmetro para determinação e diferenciação no comportamento da fadiga muscular localizada. Dois grupos de sujeitos, um caracterizado como atletas (n =12) e outro como sedentários (n =12), foram submetidos a análises baseadas em procedimentos executados em três diferentes situações experimentais, todos envolvendo a modalidade de exercício isométrico: i) teste máximo para determinação da contração isométrica voluntária máxima (CIVM); ii) teste de fadiga, sustentado por 35 seg. a 80% da CIVM; iii) teste de recuperação, sustentado por 10 seg. a 80% da CIVM; neste ultimo foi monitorado o comportamento da Fmed nos três primeiros (Fmedi) e três últimos segundos (Fmedf) do sinal EMG no músculo tibial anterior durante o teste de fadiga. Durante os 10 segundos do teste de recuperação foi calculada a Fmed referente a todo o período (Fmedr). parâmetro utilizado no cálculo do índice de recuperação muscular (IRM). Os resultados apontam que a Fmedf apresentou valor menor em relação à Fmedi em ambos os grupos (p < 0,05). Quando comparado com o grupo de sedentários, o grupo de atletas apresentou valores maiores de Fmedi e Fmedf (p < 0,05). O valor médio e desvio-padrão do IRM para o grupo de atletas foram de 62,1% ± 28,7 e, para o grupo de sedentários, de 55,2% ± 27,8 (p > 0,05). Dessa forma, os resultados apresentados neste estudo permitem inferir a viabilidade na aplicação de parâmetros no domínio da freqüência do sinal EMG para a determinação e diferenciação do comportamento da fadiga muscular localizada.