989 resultados para high performance liquid chromatography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The estrogenic activity of the Chinese herb kudzu root was investigated by a recombinant yeast screening assay (YES). Isoflavones are the main components in the plant, of which puerarin is the most abundant one. The kudzu root extract was separated into four fractions according to the polarity. The crude extract and its sub-fractions, except the water fraction, showed clear estrogenic activity and the potencies were in the range of 10(-3) to 10(-1) g/l. The ligand potency was used to compare the estrogenic activity of these fractions. The crude extract and its sub-fractions were further analyzed by high performance liquid chromatography (HPLC) to correlate the activity and the active components. Bioassay and chemical analysis showed that theoretical estrogenic activity expressed as equivalent 17 beta-estradiol concentration or the cumulative effects are comparable to that experimentally determined by YES. The results showed that the high content of isoflavones as well as the high estrogenic activity could make kudzu root extract an interesting candidate for hormone replacement therapy. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Modified nucleosides have been characterized as tumor markers for a number of malignant diseases. In order to use these markers in children, the age-dependence of the nucleoside levels in healthy children has to be established and taken into account in diagnostic decisions. In this study, the levels of 12 normal and modified nucleosides in urine of 166 healthy children and adolescents with an age between 1 day and 19 years are determined by reversed-phase HPLC, and age-dependent reference ranges are defined. The urinary nucleoside concentrations are related to the creatinine concentrations, which allows the use of randomly collected urine samples. All nucleoside levels in urine of children decrease with age, most pronounced during the first 4 years of life, and the age-dependence of the reference values of the individual nucleosides can be approximated by a mathematical function y = b(0) + b(1) (1/x) with the regression coefficients b(0) and b(1), the nucleoside levels y and the age x between 1 year and 19 years. In the very young children, the shifts in the nucleoside concentrations are more differentiated. Starting with low levels on the first day of life, the concentrations of all studied nucleosides rise up to an age of 1-2 months, when they reach their absolute maximum for all age periods, and then decrease. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A coupled-column liquid chromatographic method for the direct analysis of 14 urinary nucleosides is described. Efficient on-line clean-up and concentration of 14 nucleosides from urine samples were obtained by using a boronic acid-substituted silica column (40 turn x 4.0 mm I.D.) as the first column (Col-1) and a Hypersil ODS2 column (250 mm x 4.6 mm I.D.) as the second column (Col-2). The mobile phases applied consisted of 0.25 mol/L ammonium acetate (pH 8.5) on Col-1, and of 25 mmol/L potassium dihydrogen phosphate (pH 4.5) on Col-2, respectively. Determination of urinary nucleosides was performed on Col-2 column by using a linear gradient elution comprising 25 mmol/L potassium dihydrogen phosphate (pH 4.5) and methanol-water (60:40, v/v) with UV detection at 260 nm. Urinary nucleosides analysis can be carried out by this procedure in 50 min requiring only pH adjustment and the protein precipitation by centrifugation of urine samples. Calibration plots of 14 standard nucleosides showed excellent linearity (r > 0.995) and the limits of detection were at micromolar levels. Both of intra- and inter-day precisions of the method were better than 6.6% for direct determination of 14 nucleosides. The validated method was applied to quantify 14 nucleosides in 20 normal urines to establish reference ranges. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-performance liquid chromatography-tandem mass spectrometry has been used to identify isoflavone aglycones and glycosides in kudzu root. Fourteen isoflavones were detected. Among these, six were identified by comparison with authentic standards. Tentative identifications of the other isoflavones are based on UV spectra, mass spectra of protonated and deprotonated molecules, and MS-MS data. Several are reported for the first time in kudzu root. The bioactivity and bioavailability of isoflavone aglycones are usually greater than those of their glycosides. To improve the bioavailability of kudzu root isoflavones, crude beta-glycosidases prepared from microbes were used to hydrolyze the isoflavone glycosides. Several MS modes are combined not only to identify the isoflavones in kudzu root, but also to describe the biotransformation of kudzu root isoflavone glycosides. It is also proved that crude beta-glycosidases have high selectivity toward the O-glycosides of isoflavones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurement of steroid esters in bovine hair samples, using sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS), provides a powerful tool for identifying animals treated illicitly with growth promoters. The successful application of such testing requires appropriate sampling of hair from treated animals. This paper describes the results of hair analysis by LC-MS/MS for two animal studies in which animals were treated with estradiol-3-benzoate and nortestosterone decanoate. The results from the first animal study indicate that animals treated with these anabolic steroids may not always be identified from analysis of hair samples; positive test results occur sporadically and only for some of the treated animals. The results from the second animal study identify conditions attaching to positive hair samples, such as, that concentrations of steroid esters in hair are related to distance of sampling from point of injection and to time post-treatment, that concentrations of steroid esters in hair are related to dose given to the animal but that this relationship may vary over time post-treatment, and that steroid esters may be measured in regrowth hair taken some weeks after treatment. Steroid esters are determined along the length of the hair, confirming that accumulation of steroid esters into hair occurs from various sources, including blood, sweat and sebum. The reported research provides some useful insights into the mechanisms governing the persistence of steroid esters in bovine hair following illicit treatment with growth promoters. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microsatellite instability (MSI) is a characteristic molecular phenotype of tumors from the hereditary nonpolyposis colorectal cancer (Lynch) syndrome. Routine MSI screening of tumors in patients is an efficient prescreening tool for the population-based detection of Lynch syndrome in the absence of family cancer history. We describe here the optimization of a denaturing high performance liquid chromatography (DHPLC) assay for MSI analysis with the

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-performance liquid chromatography (HPLC) methodologies were evaluated for the detection and quantification of thyreostatic drug residues in cattle serum and thyroid tissue. The paper details a protocol, using a simple ethyl acetate extraction for the determination of thiouracil, tapazole, methyl thiouracil, propyl thiouracil and phenyl thiouracil in thyroid tissue. Using two sequential HPLC injections, and quantitative analysis, in two steps, all five thyreostats were detectable at concentrations greater than 2.45-4.52 ng/g. Modifications to a published method for detection of thyreostatic residues in serum involving the addition of mercaptoethanol and a freezing step are described. The modifications improved sensitivity and allowed detection of the five thyreostats at levels greater than 16.98-35.25 ng/ml. Young bulls were treated with thyreostats to demonstrate the validity of the methodologies described. Administered thyreostats were not absorbed equally by the test animals and the compounds were not all detected in the serum samples removed at 7 days following drug withdrawal. These experiments indicate the necessity to be able to detect thyreostat residues in a variety of matrices. (C) 1998 Elsevier Science B.V. All rights reserved.