989 resultados para diagnostic procedure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PLZT ceramics belong to one of the very important groups of functional materials that make a basis for the production of a large range of electronic devices. The microstructure and properties of ceramics depend on the powder preparation and thermal processing conditions. Various techniques have been used to obtain chemically homogeneous and fine starting powders. PLZT powders have been prepared by two different production routes: by a modified Pechini method, using a polymeric precursor method (PMM) and by a partial oxalate method. A two-step sintering process, including a hot pressing, was carried out at 1100 and 1200degreesC Distinct phases obtained during the sintering process have been investigated by SEM and EDS techniques and dielectric properties such as permittivity and dielectric loss were measured in a frequency range from 1 to 20 kHz.. A significant difference in microstructure and dielectric properties, depending on powder origin and sintering procedure, has been noticed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the total mercury determination in fish and shrimps employing chronopotentiometric stripping analysis on gold film electrodes is described. Fish and shrimp tissues were digested using a microwave oven equipped with closed vessels. We developed a microwave heating program which decomposed all the samples employing diluted nitric acid and hydrogen peroxide. The proposed method was validated by analyzing a certified reference material and then applied for different fish species from fresh water and seawater acquired in local markets of São Paulo city, Brazil. The Brazilian legislation establishes 0.5 and 1 mg per kilogram of fish as upper limit of mercury for omnivorous and predator species, respectively. Except for blue shark tissues, the mercury content was situated below 0.5 mu g g(-1) for all the analyzed samples. The detection limit of the proposed method was calculated as 5 ng g(-1) of sample utilizing 5 minutes of electrodeposition (+300 mV vs. Ag/AgCl) on the gold electrode. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Well-fitted dentures prevent hyperplasic lesions, provide chewing efficiency and promote patient's comfort. Several factors may affect final adaptation of dentures, as the type of the acrylic resin, the flask cooling procedure and the water uptake. This investigation evaluated the effect of water storage and two different cooling procedures [bench cooling (BC) for 2 h; running water (RW) at 20 degreesC for 45 min] on the final adaptation of denture bases. A heat-cured acrylic resin (CL, Classico, Classico Artigos Odontologicos) and two microwave-cured acrylic resins [Acron MC, (AC) GC Dent. Ind. Corp.; Onda Cryl (OC), Classico Artigos Odontologicos] were used to make the bases. Adaptation was assessed by measuring the weight of an intervening layer of silicone impression material between the base and the master die. Data was submitted to ANOVA and Tukey's test (0.05). The following means were found: (BC) CL=0.72 +/- 0.03 a; AC=0.70 +/- 0.03 b; OC=0.76 +/- 0.04 c//(RW) CL= 1.00 +/- 0.11 a; AC=1.00 +/- 0.12 a; OC=0.95 +/- 0.10 a. Different labels join groups that are not statistically different (P > 0.05). Comparisons are made among groups submitted to the same cooling procedure (BC or RW). The conclusions are: interaction of type of material and cooling procedure had a statistically significant effect on the final adaptation of the denture bases (P < 0.05); water storage was not detected as a source of variance (P > 0.05) on the final adaptation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A, M. Soares, V, M, Rodrigues, M. I. Homsi-Brandeburgo, M. H. Toyama, F, R, Lombardi, K. Arni and J. R, Giglio. A rapid procedure for the isolation of the Lys-49 myotoxin II from Bothrops moojeni (caissaca) venom: Biochemical characterization, crystallization, myotoxic and edematogenic activity. Toxicon 36, 503-514, 1998.-Bothrops moojeni snake venom was fractionated on a CM-Sepharose column which was previously equilibrated with 0.05 M ammonium bicarbonate buffer at pH 8.0 and subsequently eluted with an ammonium bicarbonate concentration gradient from 0.05 to 0.5 M at constant pH (8.0) and temperature (25 degrees C). The fraction which eluted last (M-VI) showed, after direct lyophilization, a single band by polyacrylamide gel electrophoresis (PAGE) and SDS-PAGE, indicating an approximate M,. of 14 000 and 77 000, in the presence and absence of dithiothreitol, respectively. Its amino acid composition revealed a high level of hydrophobic and basic amino acids as well as 13 half-cystine residues. Its isoelectric point and extinction coefficient (E-1.0cm(1.0mg/ml) at 278 nm and pH 7.0) were 8.2 and 1.170, respectively. M-VI was devoid of phospholipase A(2) (PLA(2)) activity on egg yolk, as well as of hemorrhagic, anticoagulant and coagulant activities, but could induce drastic necrosis on skeletal muscle fibres as well as rapid and transient edema on the rat paw. Its N-terminal sequence: SLFELGKMILQETGKNPAKSYGVYGCNCGVGGRGKPKDATDRCCYVHKCCYK.... revealed high homology with other Lys 49 PLA(2)-like myotoxins from other bothropic venoms. Orthorhombic crystals of M-VI? which diffracted to a maximal resolution of 1.6 Angstrom. were obtained and indicated the presence of a dimer in the asymmetrical unit. (C) 1998 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The routine methods for detecting Listeria sp. in foods are time consuming and involve using selective enrichments and plating on agars. In this study, the presence of Listeria sp. in 120 meat and meat product samples was investigated by two rapid immunoassays (TECRA Listeria Visual Immunoassay [VIA] and BioControl Visual Immunoprecipitate Assay [VIP] for Listeria) and a cultural procedure. The cultural method of detecting Listeria sp. followed Canada's Health Protection Branch Method, and the rapid tests followed the manufacturers' instructions. The agreement between the cultural and the rapid tests was established at a confidence limit of 95%. Seventy-nine samples (65.8%) were Listeria sp. positive in at least one of the three tests. There was no statistically significant difference between the cultural procedure and any of the rapid immunoassays. The agreement rates between the VIA and the cultural method and between the VIP and the cultural method were 87 and 84%, respectively. Both tests - the VIA and VIP - proved to be rapid, efficient and easy to perform.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ranzini (1988) proposed the Standard Penetration Test with torque measurement (SPT-T) and some geotechnical engineers in Brazil have been using it since 1991. This paper presents the state of the art on SPT-T testing, emphasizing what is already established as common knowledge in Brazilian engineering practice, besides a suggestion for test procedure, including equipment and practical aspects. In addition, the study of the shape of the torque versus rotation-degree angle curve obtained by an electric torquemeter used in several SPT-T tests carried out on six experimental research sites in the southeast region of Brazil is discussed here. Four different methods to predict pile capacity based on SPT-T test results are briefly presented and a comparison with load tests carried out on different types of piles, on those six experimental research sites, is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We start this work by revisiting the problem of the soldering of two chiral Schwinger models of opposite chiralities. We verify that, different from what one can conclude from the current literature, the usual sum of these models is, in fact, gauge invariant and corresponds to a composite model, where the component models are the vector and axial Schwinger models. As a consequence, we reinterpret this formalism as a kind of degree of freedom reduction mechanism. This result has led us to discover a second soldering possibility giving rise to the axial Schwinger model. This new result is seemingly rather general. We explore it here in the soldering of two Maxwell-Chern-Simons theories with different masses.