364 resultados para alarm desensitisation


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim: The aim of this survey was to assess registered nurse’s perceptions of alarm setting and management in an Australian Regional Critical Care Unit. Background: The setting and management of alarms within the critical care environment is one of the key responsibilities of the nurse in this area. However, with up to 99% of alarms potentially being false-positives it is easy for the nurse to become desensitised or fatigued by incessant alarms; in some cases up to 400 per patient per day. Inadvertently ignoring, silencing or disabling alarms can have deleterious implications for the patient and nurse. Method: A total population sample of 48 nursing staff from a 13 bedded ICU/HDU/CCU within regional Australia were asked to participate. A 10 item open-ended and multiple choice questionnaire was distributed to determine their perceptions and attitudes of alarm setting and management within this clinical area. Results: Two key themes were identified from the open-ended questions: attitudes towards inappropriate alarm settings and annoyance at delayed responses to alarms. A significant number of respondents (93%) agreed that alarm fatigue can result in alarm desensitisation and the disabling of alarms, whilst 81% suggested the key factors are those associated with false-positive alarms and inappropriately set alarms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a preliminary flight test based detection range versus false alarm performance characterisation of a morphological-hidden Markov model filtering approach to vision-based airborne dim-target collision detection. On the basis of compelling in-flight collision scenario data, we calculate system operating characteristic (SOC) curves that concisely illustrate the detection range versus false alarm rate performance design trade-offs. These preliminary SOC curves provide a more complete dim-target detection performance description than previous studies (due to the experimental difficulties involved, previous studies have been limited to very short flight data sample sets and hence have not been able to quantify false alarm behaviour). The preliminary investigation here is based on data collected from 4 controlled collision encounters and supporting non-target flight data. This study suggests head-on detection ranges of approximately 2.22 km under blue sky background conditions (1.26 km in cluttered background conditions), whilst experiencing false alarms at a rate less than 1.7 false alarms/hour (ie. less than once every 36 minutes). Further data collection is currently in progress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary objective of the experiments reported here was to demonstrate the effects of opening up the design envelope for auditory alarms on the ability of people to learn the meanings of a set of alarms. Two sets of alarms were tested, one already extant and one newly-designed set for the same set of functions, designed according to a rationale set out by the authors aimed at increasing the heterogeneity of the alarm set and incorporating some well-established principles of alarm design. For both sets of alarms, a similarity-rating experiment was followed by a learning experiment. The results showed that the newly-designed set was judged to be more internally dissimilar, and easier to learn, than the extant set. The design rationale outlined in the paper is useful for design purposes in a variety of practical domains and shows how alarm designers, even at a relatively late stage in the design process, can improve the efficacy of an alarm set.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a survey of previously presented vision based aircraft detection flight test, and then presents new flight test results examining the impact of camera field-of view choice on the detection range and false alarm rate characteristics of a vision-based aircraft detection technique. Using data collected from approaching aircraft, we examine the impact of camera fieldof-view choice and confirm that, when aiming for similar levels of detection confidence, an improvement in detection range can be obtained by choosing a smaller effective field-of-view (in terms of degrees per pixel).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditional analytic models for power system fault diagnosis are usually formulated as an unconstrained 0–1 integer programming problem. The key issue of the models is to seek the fault hypothesis that minimizes the discrepancy between the actual and the expected states of the concerned protective relays and circuit breakers. The temporal information of alarm messages has not been well utilized in these methods, and as a result, the diagnosis results may be not unique and hence indefinite, especially when complicated and multiple faults occur. In order to solve this problem, this paper presents a novel analytic model employing the temporal information of alarm messages along with the concept of related path. The temporal relationship among the actions of protective relays and circuit breakers, and the different protection configurations in a modern power system can be reasonably represented by the developed model, and therefore, the diagnosed results will be more definite under different circumstances of faults. Finally, an actual power system fault was served to verify the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On Saturday, 25 October 1997 a five year old boy died in the Intensive Care Unit (ICU) of Royal Darwin Hospital (RDH) from meningococcal disease. While disease is expected throughout Australia during the late winter and early spring months, and deaths occur, this case was remarkable in the Northern Territory with respect to the unprecedented public response to media reports of the death.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electronic instrument for measuring freezer temperature in the range of +40 to -40°C is described. The salient features of the instrument are remote display (digital and analogue versions with an accuracy of ± 0.1 and ± 0.5°C respectively) and provision for continuous record of temperature. Two types of sensors using thermistor and P. N. function of transistor were used for temperature sensing.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liquid nitrogen is very important for MBE system. Most MBE systems use the liquid nitrogen to absorb the impurity molecules. If MBE cryoshroud is lack of liquid nitrogen, the pressure of the growth chamber will grow. This will affect the film quality. But too much liquid nitrogen is a waste. We have developed a liquid nitrogen flowrate alarm system to monitor the liquid nitrogen status in MBE cryoshroud. In this method, a temperature sensor is placed at the end of the cryoshroud. The temperature varies with changing of the liquid nitrogen status in cryoshroud. If the liquid nitrogen level in the cryoshroud is too low or too high, the LNFA will send out an alarm to warn the user to adjust the liquid nitrogen flowrate. In our experiments, we found this method works well, and the temperature responds sensitively. With the help of this system, people can view the liquid nitrogen status of the entire growth process. Compare with other method. it is very cheap.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We expect scientists to follow a code of honor and conduct and to report their research honestly and accurately, but so-called scientific misconduct, which includes plagiarism, faked data, and altered images, has led to a tenfold increase in the number of retractions over the past decade. Among the reasons for this troubling upsurge is increased competition for journal placement, grant money, and prestigious appointments. The solutions are not easy, but reform and greater vigilance is needed.