202 resultados para VALVULA MITRAL


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Describir mediciones 3D y hallazgos estructurales de válvula mitral, en pacientes sanos, y con insuficiencia mitral grado 3 o 4, con enfermedad coronaria, patologías degenerativas o cardiopatía dilatada no isquémica, mediante uso de ecocardiografia transesofágica 3D en tiempo real.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La patología de la válvula mitral tiene gran prevalencia dentro de la enfermedad cardiaca. Con nuevas técnicas diagnósticas se perfecciona la caracterización de la válvula mitral y la ecocardiografía tridimensional tras esofágica, ha permitido obtener mejor información acerca de la patología valvular mitral. Objetivo principal : describir estructural y anatómicamente la válvula mitral, sus medidas y relaciones espaciales tridimensionales, en pacientes catalogados con válvula normal comparándolos con pacientes con insuficiencia mitral; en estudios realizados mediante ecocardiografía tras esofágica tridimensional. Materiales y métodos : estudio descriptivo, prospectivo con una serie de casos de válvulas mitrales normales comparadas con insuficientes : Obtención - Imagen tras esofágica 3D en tiempo real - Análisis y procesamiento de la imagen - Reconstrucción Tridimensional. Obtención de las diferentes medidas anatómicas estructurales que servirán para la tipificación de la válvula mitral en 3D. Análisis descriptivo : se utilizarán distribuciones de frecuencia y distribuciones porcentuales y en las variables de tipo cuantitativo medidas de tendencia central y medidas de variabilidad y dispersión. Resultados : se evaluaron durante el periodo de tiempo comprendido entre junio de 2008 y agosto de 2009 un total de 113 pacientes en total, encontrando claras diferencias en la estructura de las insuficiencias por prolapso. No hubo diferenciación en las cardiopatía isquémica vs dilatada. Conclusión : en el prolapso mitral aporta datos en la identificación etiológica ya sea degenerativa fibroelástica o enfermedad de Barlow. No hay diferencia significativa en la estructura que ayude caracterizar cardiopatía isquémica vs cardiopatía dilatada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Pregnant women with mechanical prosthetic heart valves are at increased risk for valve thrombosis. Management decisions for this life-threatening complication are complex. Open-heart surgery has a very high risk of maternal mortality and fetal loss. Bleeding and embolic risks associated with thrombolytic agents, the limited efficacy of thrombolysis in certain subgroups, and a lack of experience in the setting of pregnancy raise important concerns. CASE REPORT: We report a case of mitral prosthetic valve thrombosis in early pregnancy, which was successfully treated with streptokinase. Ten years later, the same patient had an uneventful pregnancy, throughout which acenocoumarol was maintained. CONCLUSION: With this case we review the prevention (with oral anticoagulant therapy) and treatment of prosthetic valve thrombosis during pregnancy, which is important for both obstetrician and cardiologist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Mitral regurgitation (MR) is the most common valvular disease and has recently become the target of a number of percutaneous approaches. The MitraClip is virtually the only device for which there is considerable experience, with more than 20,000 procedures performed worldwide. OBJECTIVE: To describe our initial experience of the percutaneous treatment of MR with the MitraClip device. METHODS: We describe the first six MitraClip cases performed in this institution (mean age 58.5 ± 13.1 years), with functional MR grade 4+ and New York Heart Association (NYHA) heart failure class III or IV (n=3), with a mean follow-up of 290 ± 145 days. RESULTS: Procedural success (MR ≤ 2+) was 100%. Total procedure time was 115.8 ± 23.7 min, with no in-hospital adverse events and discharge between the fourth and eighth day, and consistent improvement in the six-minute walk test (329.8 ± 98.42 vs. 385.33 ± 106.95 m) and in NYHA class (three patients improved by two NYHA classes). During follow-up there were two deaths, in two of the four patients who had been initially considered for heart transplantation. CONCLUSION: In patients with functional MR the MitraClip procedure is safe, with both a high implantation and immediate in-hospital success rate. A longer follow-up suggests that the clinical benefit decreases or disappears completely in patients with more advanced heart disease, namely those denied transplantation or on the heart transplant waiting list.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mitral regurgitation (MR) involves systolic retrograde flow from the left ventricle into the left atrium. While trivial MR is frequent in healthy subjects, moderate to severe MR constitutes the second most prevalent valve disease after aortic valve stenosis. Major causes of severe MR in Western countries include degenerative valve disease (myxomatous disease, flail leaflet, annular calcification) and ischaemic heart disease, while rheumatic disease remains a major cause of MR in developing countries. Chronic MR typically progresses insidiously over many years. Once established, however, severe MR portends a poor prognosis. The severity of MR can be assessed by various techniques, Doppler echocardiography being the most widely used. Mitral valve surgery is the only treatment of proven efficacy. It alleviates clinical symptoms and prevents ventricular dilatation and heart failure (or, at least, it attenuates further progression of these abnormalities). Valve repair significantly improves clinical outcomes compared with valve replacement, reducing mortality by approximately 70%. Reverse LV remodelling after valve repair occurs in half of patients with functional MR. Percutaneous, catheter-based to mitral valve repair is a novel approach currently under clinical scrutiny, with encouraging preliminary results. This modality may provide a valuable alternative to mitral valve surgery, especially in critically ill patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contexte: La régurgitation mitrale (RM) est une maladie valvulaire nécessitant une intervention dans les cas les plus grave. Une réparation percutanée de la valve mitrale avec le dispositif MitraClip est un traitement sécuritaire et efficace pour les patients à haut risque chirurgical. Nous voulons évaluer les résultats cliniques et l'impact économique de cette thérapie par rapport à la gestion médicale des patients en insuffisance cardiaque avec insuffisance mitrale symptomatique. Méthodes: L'étude a été composée de deux phases; une étude d'observation de patients souffrant d'insuffisance cardiaque et de régurgitation mitrale traitée avec une thérapie médicale ou le MitraClip, et un modèle économique. Les résultats de l'étude observationnelle ont été utilisés pour estimer les paramètres du modèle de décision, qui a estimé les coûts et les avantages d'une cohorte hypothétique de patients atteints d'insuffisance cardiaque et insuffisance mitrale sévère traitée avec soit un traitement médical standard ou MitraClip. Résultats: La cohorte de patients traités avec le système MitraClip était appariée par score de propension à une population de patients atteints d'insuffisance cardiaque, et leurs résultats ont été comparés. Avec un suivi moyen de 22 mois, la mortalité était de 21% dans la cohorte MitraClip et de 42% dans la cohorte de gestion médicale (p = 0,007). Le modèle de décision a démontré que MitraClip augmente l'espérance de vie de 1,87 à 3,60 années et des années de vie pondérées par la qualité (QALY) de 1,13 à 2,76 ans. Le coût marginal était 52.500 $ dollars canadiens, correspondant à un rapport coût-efficacité différentiel (RCED) de 32,300.00 $ par QALY gagné. Les résultats étaient sensibles à l'avantage de survie. Conclusion: Dans cette cohorte de patients atteints d'insuffisance cardiaque symptomatique et d insuffisance mitrale significative, la thérapie avec le MitraClip est associée à une survie supérieure et est rentable par rapport au traitement médical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVOS: Describir y comparar los cambios dinámicos de la geometría del anillo mitral durante todo el ciclo cardiaco en pacientes con insuficiencia mitral isquémica y pacientes con válvula mitral normal. MATERIALES Y MÉTODOS: Los estudios ecocardiográficos analizados fueron 37, 23 con insuficiencia mitral isquémica y 14 con válvula mitral normal. La reconstrucción del anillo se realizó en la estación de trabajo Xcelera (Philips Medial Systems) mediante la herramienta de análisis mitral (MVQ), en 5 momentos del ciclo cardiaco: Comienzo de Sístole, Mitad de Sístole, Final de Sístole, Mitad de Diástole y Final de Diástole. RESULTADOS: El anillo del grupo control, fue más dinámico, con sus menores dimensiones al final de la diástole, presentando incremento progresivo durante la sístole. Los cambios en el perímetro y el área, fueron significativos entre el comienzo y mitad de la sístole (p:0.087 y p: 0.055). En el grupo con insuficiencia mitral isquémica, el anillo fue más estático. Todas las dimensiones en este grupo, fueron mayores en los cinco momentos del ciclo cardiaco. (p < 0.1). El anillo también fue más plano, con un índice morfológico anular menor al del grupo control (p:0.087). DISCUSIÓN Y CONCLUSIONES: En pacientes sin insuficiencia mitral, el anillo es una estructura dinámica. Durante la sístole, las menores dimensiones se produjeron al comienzo de este periodo y la conformación en silla de montar se mantuvo, protegiendo contra la insuficiencia mitral. El anillo del grupo con insuficiencia mitral fue más estático y plano, perdiendo los mecanismos protectores.