994 resultados para TRANSCRANIAL DOPPLER ULTRASONOGRAPHY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

the aim of this study was to investigate specific activation patterns and potential gender differences during mental rotation and to investigate whether functional magnetic resonance imaging (fMRI) and functional transcranial Doppler sonography (fTCD) lateralize hemispheric dominance concordantly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The suspected cause of clinical manifestations of patent foramen ovale (PFO) is a transient or a permanent right-to-left shunt (RLS). Contrast-enhanced transcranial Doppler ultrasound (c-TCD) is a reliable alternative to transesophageal echocardiography (TEE) for diagnosis of PFO, and enables also the detection of extracardiac RLS. The air-containing echo contrast agents are injected intravenously and do not pass the pulmonary circulation. In the presence of RLS, the contrast agents bypass the pulmonary circulation and cause microembolic signals (MES) in the basal cerebral arteries, which are detected by TCD. The two main echo contrast agents in use are agitated saline and D-galactose microparticle solutions. At least one middle cerebral artery (MCA) is insonated, and the ultrasound probe is fixed with a headframe. The monitored Doppler spectra are stored for offline analysis (e.g., videotape) of the time of occurrence and number of MES, which are used to assess the size and functional relevance of the RLS. The examination is more sensitive, if both MCAs are investigated. In the case of negative testing, the examination is repeated using the Valsalva maneuver. Compared to TEE, c-TCD is more comfortable for the patient, enables an easier assessment of the size and functional relevance of the RLS, and allows also the detection of extracardiac RLS. However, c-TCD cannot localize the site of the RLS. Therefore, TEE and TCD are complementary methods and should be applied jointly in order to increase the diagnostic accuracy for detecting PFO and other types of RLS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess the intra-reader and inter-reader reliabilities of interpreting ultrasonography by several experts using video clips. METHOD: 99 video clips of healthy and rheumatic joints were recorded and delivered to 17 physician sonographers in two rounds. The intra-reader and inter-reader reliabilities of interpreting the ultrasound results were calculated using a dichotomous system (normal/abnormal) and a graded semiquantitative scoring system. RESULTS: The video reading method worked well. 70% of the readers could classify at least 70% of the cases correctly as normal or abnormal. The distribution of readers answering correctly was wide. The most difficult joints to assess were the elbow, wrist, metacarpophalangeal (MCP) and knee joints. The intra-reader and inter-reader agreements on interpreting dynamic ultrasound images as normal or abnormal, as well as detecting and scoring a Doppler signal were moderate to good (kappa = 0.52-0.82). CONCLUSIONS: Dynamic image assessment (video clips) can be used as an alternative method in ultrasonography reliability studies. The intra-reader and inter-reader reliabilities of ultrasonography in dynamic image reading are acceptable, but more definitions and training are needed to improve sonographic reproducibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. Background Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear. Methods Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. Results No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: <0.001) or post-implantation PI (SA: p = 0.007; ES: <0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients). Conclusions Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The adequacy of anesthesia has been studied since the introduction of balanced general anesthesia. Commercial monitors based on electroencephalographic (EEG) signal analysis have been available for monitoring the hypnotic component of anesthesia from the beginning of the 1990s. Monitors measuring the depth of anesthesia assess the cortical function of the brain, and have gained acceptance during surgical anesthesia with most of the anesthetic agents used. However, due to frequent artifacts, they are considered unsuitable for monitoring consciousness in intensive care patients. The assessment of analgesia is one of the cornerstones of general anesthesia. Prolonged surgical stress may lead to increased morbidity and delayed postoperative recovery. However, no validated monitoring method is currently available for evaluating analgesia during general anesthesia. Awareness during anesthesia is caused by an inadequate level of hypnosis. This rare but severe complication of general anesthesia may lead to marked emotional stress and possibly posttraumatic stress disorder. In the present series of studies, the incidence of awareness and recall during outpatient anesthesia was evaluated and compared with that of in inpatient anesthesia. A total of 1500 outpatients and 2343 inpatients underwent a structured interview. Clear intraoperative recollections were rare the incidence being 0.07% in outpatients and 0.13% in inpatients. No significant differences emerged between outpatients and inpatients. However, significantly smaller doses of sevoflurane were administered to outpatients with awareness than those without recollections (p<0.05). EEG artifacts in 16 brain-dead organ donors were evaluated during organ harvest surgery in a prospective, open, nonselective study. The source of the frontotemporal biosignals in brain-dead subjects was studied, and the resistance of bispectral index (BIS) and Entropy to the signal artifacts was compared. The hypothesis was that in brain-dead subjects, most of the biosignals recorded from the forehead would consist of artifacts. The original EEG was recorded and State Entropy (SE), Response Entropy (RE), and BIS were calculated and monitored during solid organ harvest. SE differed from zero (inactive EEG) in 28%, RE in 29%, and BIS in 68% of the total recording time (p<0.0001 for all). The median values during the operation were SE 0.0, RE 0.0, and BIS 3.0. In four of the 16 organ donors, EEG was not inactive, and unphysiologically distributed, nonreactive rhythmic theta activity was present in the original EEG signal. After the results from subjects with persistent residual EEG activity were excluded, SE, RE, and BIS differed from zero in 17%, 18%, and 62% of the recorded time, respectively (p<0.0001 for all). Due to various artifacts, the highest readings in all indices were recorded without neuromuscular blockade. The main sources of artifacts were electrocauterization, electromyography (EMG), 50-Hz artifact, handling of the donor, ballistocardiography, and electrocardiography. In a prospective, randomized study of 26 patients, the ability of Surgical Stress Index (SSI) to differentiate patients with two clinically different analgesic levels during shoulder surgery was evaluated. SSI values were lower in patients with an interscalene brachial plexus block than in patients without an additional plexus block. In all patients, anesthesia was maintained with desflurane, the concentration of which was targeted to maintain SE at 50. Increased blood pressure or heart rate (HR), movement, and coughing were considered signs of intraoperative nociception and treated with alfentanil. Photoplethysmographic waveforms were collected from the contralateral arm to the operated side, and SSI was calculated offline. Two minutes after skin incision, SSI was not increased in the brachial plexus block group and was lower (38 ± 13) than in the control group (58 ± 13, p<0.005). Among the controls, one minute prior to alfentanil administration, SSI value was higher than during periods of adequate antinociception, 59 ± 11 vs. 39 ± 12 (p<0.01). The total cumulative need for alfentanil was higher in controls (2.7 ± 1.2 mg) than in the brachial plexus block group (1.6 ± 0.5 mg, p=0.008). Tetanic stimulation to the ulnar region of the hand increased SSI significantly only among patients with a brachial plexus block not covering the site of stimulation. Prognostic value of EEG-derived indices was evaluated and compared with Transcranial Doppler Ultrasonography (TCD), serum neuron-specific enolase (NSE) and S-100B after cardiac arrest. Thirty patients resuscitated from out-of-hospital arrest and treated with induced mild hypothermia for 24 h were included. Original EEG signal was recorded, and burst suppression ratio (BSR), RE, SE, and wavelet subband entropy (WSE) were calculated. Neurological outcome during the six-month period after arrest was assessed with the Glasgow-Pittsburgh Cerebral Performance Categories (CPC). Twenty patients had a CPC of 1-2, one patient had a CPC of 3, and nine patients died (CPC 5). BSR, RE, and SE differed between good (CPC 1-2) and poor (CPC 3-5) outcome groups (p=0.011, p=0.011, p=0.008, respectively) during the first 24 h after arrest. WSE was borderline higher in the good outcome group between 24 and 48 h after arrest (p=0.050). All patients with status epilepticus died, and their WSE values were lower (p=0.022). S-100B was lower in the good outcome group upon arrival at the intensive care unit (p=0.010). After hypothermia treatment, NSE and S-100B values were lower (p=0.002 for both) in the good outcome group. The pulsatile index was also lower in the good outcome group (p=0.004). In conclusion, the incidence of awareness in outpatient anesthesia did not differ from that in inpatient anesthesia. Outpatients are not at increased risk for intraoperative awareness relative to inpatients undergoing general anesthesia. SE, RE, and BIS showed non-zero values that normally indicate cortical neuronal function, but were in these subjects mostly due to artifacts after clinical brain death diagnosis. Entropy was more resistant to artifacts than BIS. During general anesthesia and surgery, SSI values were lower in patients with interscalene brachial plexus block covering the sites of nociceptive stimuli. In detecting nociceptive stimuli, SSI performed better than HR, blood pressure, or RE. BSR, RE, and SE differed between the good and poor neurological outcome groups during the first 24 h after cardiac arrest, and they may be an aid in differentiating patients with good neurological outcomes from those with poor outcomes after out-of-hospital cardiac arrest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Object. Sonothrombolysis has recently been considered an emerging modality for the treatment of stroke. The purpose of the present paper was to review randomized clinical studies concerning the effects of sonothrombolysis associated with tissue plasminogen activator (tPA) on acute ischemic stroke. Methods. Systematic searches for literature published between January 1996 and July 2011 were performed for studies regarding sonothrombolysis combined with tPA for acute ischemic stroke. Only randomized controlled trials were included. Data extraction was based on ultrasound variables, patient characteristics, and outcome variables (rate of intracranial hemorrhages and arterial recanalization). Results. Four trials were included in this study; 2 trials evaluated the effect of transcranial Doppler (TCD) ultrasonography on sonothrombolysis, and 2 addressed transcranial color-coded duplex (TCCD) ultrasonography. The frequency of ultrasound waves varied from 1.8 to 2 MHz. The duration of thrombus exposure to ultrasound energy ranged from 60 to 120 minutes. Sample sizes were small, recanalization was evaluated at different time points (60 and 120 minutes), and inclusion criteria were heterogeneous. Sonothrombolysis combined with tPA did not lead to an increase in symptomatic intracranial hemorrhagic complications. Two studies demonstrated that patients treated with ultrasound combined with tPA had statistically significant higher rates of recanalization than patients treated with tPA alone. Conclusions. Despite the heterogeneity and the limitations of the reviewed studies, there is evidence that sonothrombolysis associated with tPA is a safe procedure and results in an increased rate of recanalization in the setting of acute ischemic stroke when wave frequencies and energy intensities of diagnostic ultrasound systems are used. (http://thejns.org/doi/abs/10.3171/2011.10.FOCUS11251)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to describe magnetic resonance imaging (MRI) findings associated with presumed elevated intracranial pressure (ICP) in dogs and to evaluate whether MRI could be used to discriminate between dogs with and without elevated ICP. Of 91 dogs that underwent cranial MRI examination, 18 (19.8%) were diagnosed with elevated ICP based on neurological examination, fundoscopy and transcranial Doppler ultrasonography. The MRI findings that showed the strongest association with elevated ICP were mass effect (odds ratio [OR], 78.5), caudal transtentorial herniation (OR, 72.0), subfalcine herniation (OR, 45.6), perilesional oedema (OR, 34.0), displacement of the lamina quadrigemina (OR, 27.7) and effacement of the cerebral sulci (OR, 27.1). The presence of any two or more of the following MRI findings identified elevated ICP with a sensitivity of 72% and a specificity of 96%: compression of the suprapineal recess, compression of the third ventricle, compression of the fourth ventricle, effacement of the cerebral sulci and caudal transposition of the lamina quadrigemina. In conclusion, there is an association between MRI findings and elevated ICP in dogs; therefore, MRI might be useful to discriminate between dogs with and without elevated ICP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Annually hundreds of crab-eating foxes (Cerdocyon thous) are referred to rehabilitation centers and zoos in Brazil. The ultrasonographic study of wildlife species is an important tool for a non-invasive and accurate anatomical description and provides important information for wildlife veterinary care. The aim of the present study was to determine the characteristics of the main abdominal organs as well as the vascular indexes of the abdominal aorta and renal arteries of crab-eating foxes (Cerdocyon thous) using mode B ultrasonography and Doppler ultrasonography, respectively. Ultrasonographic features of the main abdominal organs were described and slight differences were noticed between ultrasound imaging of abdominal organs of crab-eating foxes and other species. The bladder presented wall thickness of 12 +/- 0.01 mm, with three defined layers. Both, the right and left kidneys presented corticomedullary ratio of 1: 1 and similarly to the adrenals and the liver, they were homogeneous and hypoechoic compared to the spleen. The spleen was homogeneous and hyperechoic compared to the kidneys. The stomach presented 3 to 5 peristaltic movements per minute, wall thickness of 39 +/- 0.05 mm and lumen and mucosa with hyperechoic and hypoechoic features, respectively. Small and large intestines presented 2 to 3 peristaltic movements per minute, wall thickness of 34 +/- 0.03 mm and three defined layers with hyperechogenic (submucosa and serosa) and hypoechogenic (muscular) features. Ovaries of the female crab-eating fox were hypoechoic compared to the spleen and with heterogeneous parenchyma due to the presence of 2x2 mm ovarian follicles. Prostates of the six males were regular and with a well defined boundary, with a homogeneous and hyperechoic parenchyma compared to the spleen. Vascular indexes of the abdominal aorta (PSV: 25.60 +/- 0.32 cm/s; EDV: 6.96 +/- 1.68cm/s; PI: 1.15 +/- 0.07 e RI: 0.73 +/- 0.07) and right (PSV: 23.08 +/- 3.34cm/s; EDV: 9.33 +/- 2.36cm/s; PI: 1.01 +/- 0.65 e RI: 0.65 +/- 0.16) and left renal arteries (PSV: 23.74 +/- 3.94cm/s; EDV: 9.07 +/- 3.02cm/s; PI: 1.04 +/- 0.31 e RI: 0.64 +/- 0.10) were determined. Thus, conventional and Doppler ultrasonographic imaging provides basic information that can be used as reference for the species as well for other wild canids and it is a precise and non-invasive method that can be safely used to evaluate and diagnose abdominal injuries in these patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neurosonological studies, specifically transcranial Doppler (TCD) and transcranial color-coded duplex (TCCD), have high level of specificity and sensitivity and they are used as complementary tests for the diagnosis of brain death (BD). A group of experts, from the Neurosonology Department of the Brazilian Academy of Neurology, created a task force to determine the criteria for the following aspects of diagnosing BD in Brazil: the reliability of TCD methodology; the reliability of TCCD methodology; neurosonology training and skills; the diagnosis of encephalic circulatory arrest; and exam documentation for BD. The results of this meeting are presented in the current paper.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objetivo: Avaliar o efeito do tartarato de brimonidina a 0,2% tópico, instilado de 12/12 horas, na circulação retrobulbar em pacientes portadores de glaucoma. Métodos: Foram estudados os 2 olhos de 16 pacientes portadores de glaucoma primário de ângulo aberto e glaucoma crônico de ângulo estreito com iridotomia. Usando o Doppler colorido foram avaliados: velocidade sistólica máxima, velocidade diastólica final e índice de resistência das artéria central da retina, artéria ciliar posterior curta temporal e artéria oftálmica. As avaliações foram feitas antes e depois do uso da brimonidina. Resultados: O tartarato de brimonidina a 0,2% aumentou significativamente a velocidade sistólica máxima (28,24 para 34,23 cm/seg) e velocidade diastólica final (6,62 para 8,10 cm/seg) no olho direito e reduziu o índice de resistência (0,75 para 0,71) no olho esquerdo da artéria oftálmica. Conclusão: O tartarato de brimonidina 0,2% 2x/dia aumentou significativamente a velocidade sistólica máxima e velocidade diastólica final e reduziu índice de resistência da artéria oftálmica de pacientes glaucomatosos. Este efeito sugere que a brimonidina pode beneficiar pacientes glaucomatosos com insuficiência vascular na cabeça do nervo óptico.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A perfusão total do fígado e suas contribuições relativas, pelo sistema portal e pela artéria hepática, podem estar alteradas por vários processos hepáticos, como doença hepato-celular difusa, neoplasia e shunts intra-hepáticos. O estudo do comportamento do fluxo sangüíneo nos vasos do fígado por meio da ultra-sonografia Doppler tem demonstrado que este é um método viável não-invasivo e de grande auxílio, principalmente na avaliação da hemodinâmica portal. São duas as modalidades de ultra-sonografia Doppler com maior aplicação na rotina para avaliação de fluxo nos vasos abdominais, o Doppler espectral e o Doppler colorido. Na doença hepática crônica, ocorre alteração da complacência hepática devido à fibrose ou à cirrose, as quais acarretam alterações vasculares, levando ao aumento da pressão venosa portal. As principais indicações desse exame são os casos em que há suspeita de hipertensão portal. A hemodinâmica portal é avaliada pela mensuração de sua área, da velocidade média, do volume de fluxo no vaso e do índice de congestão portal. Esta revisão de literatura tem como objetivo descrever os princípios físicos básicos da ultra-sonografia Doppler e sua aplicação na avaliação da hemodinâmica portal nos cães.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Os programas comerciais de transferência de embriões em éguas existem por mais de três décadas e são hoje uma das biotécnias mais utilizadas na reprodução assistida de equinos. O exame ultrassonográfico nos períodos pré e pós-cobertura de doadoras de embriões, assim como a avaliação de receptoras no momento da inovulação é de vital importância para o êxito de um programa de transferência de embriões. A ultrassonografia Doppler é uma técnica não-invasiva que permite a avaliação em tempo real da hemodinâmica do trato reprodutivo de animais de grande porte. Por fornecer detalhes anatômicos e informações imediatas sobre a fisiologia do fluxo sanguíneo de tecidos e órgãos, o exame doppler permite a avaliação do potencial ovulatório de folículos e do status funcional de corpo lúteo e útero, além de ser uma técnica auxiliar para o diagnóstico de distúrbios na hemodinâmica do sistema reprodutivo. Alterações na perfusão sanguínea dos futuros folículos dominantes são detectáveis em diferentes fases de seu desenvolvimento, como na divergência folicular e no período pré-ovulatório. A partir dessas informações, é possível determinar o princípio da atividade sexual e o momento ideal para o início de tratamentos superovulatórios e indutores de ovulação, assim como o momento mais apropriado para a realização de coberturas de éguas doadoras de embriões. A avaliação através do modo-Doppler do corpo lúteo e útero de éguas receptoras é também um instrumento auxiliar para a seleção de animais com perfil sérico de progesterona e ambiente uterino adequados para a sobrevivência do embrião e manutenção da gestação. Essa técnica pode ser útil ainda ao se avaliar a interação concepto-maternal. Apesar da aplicabilidade da tecnologia doppler dentro de programas de transferência de embriões, novos estudos visando a determinar padrões de normalidade e posterior caracterização de distúrbios de fluxo sanguíneo de trato reprodutivo ainda se fazem necessários.