56 resultados para Synchronism


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Queensland University of Technology (QUT) allows the presentation of a thesis for the Degree of Doctor of Philosophy in the format of published or submitted papers, where such papers have been published, accepted or submitted during the period of candidature. This thesis is composed of seven published/submitted papers, of which one has been published, three accepted for publication and the other three are under review. This project is financially supported by an Australian Research Council (ARC) Discovery Grant with the aim of proposing strategies for the performance control of Distributed Generation (DG) system with digital estimation of power system signal parameters. Distributed Generation (DG) has been recently introduced as a new concept for the generation of power and the enhancement of conventionally produced electricity. Global warming issue calls for renewable energy resources in electricity production. Distributed generation based on solar energy (photovoltaic and solar thermal), wind, biomass, mini-hydro along with use of fuel cell and micro turbine will gain substantial momentum in the near future. Technically, DG can be a viable solution for the issue of the integration of renewable or non-conventional energy resources. Basically, DG sources can be connected to local power system through power electronic devices, i.e. inverters or ac-ac converters. The interconnection of DG systems to power system as a compensator or a power source with high quality performance is the main aim of this study. Source and load unbalance, load non-linearity, interharmonic distortion, supply voltage distortion, distortion at the point of common coupling in weak source cases, source current power factor, and synchronism of generated currents or voltages are the issues of concern. The interconnection of DG sources shall be carried out by using power electronics switching devices that inject high frequency components rather than the desired current. Also, noise and harmonic distortions can impact the performance of the control strategies. To be able to mitigate the negative effect of high frequency and harmonic as well as noise distortion to achieve satisfactory performance of DG systems, new methods of signal parameter estimation have been proposed in this thesis. These methods are based on processing the digital samples of power system signals. Thus, proposing advanced techniques for the digital estimation of signal parameters and methods for the generation of DG reference currents using the estimates provided is the targeted scope of this thesis. An introduction to this research – including a description of the research problem, the literature review and an account of the research progress linking the research papers – is presented in Chapter 1. One of the main parameters of a power system signal is its frequency. Phasor Measurement (PM) technique is one of the renowned and advanced techniques used for the estimation of power system frequency. Chapter 2 focuses on an in-depth analysis conducted on the PM technique to reveal its strengths and drawbacks. The analysis will be followed by a new technique proposed to enhance the speed of the PM technique while the input signal is free of even-order harmonics. The other techniques proposed in this thesis as the novel ones will be compared with the PM technique comprehensively studied in Chapter 2. An algorithm based on the concept of Kalman filtering is proposed in Chapter 3. The algorithm is intended to estimate signal parameters like amplitude, frequency and phase angle in the online mode. The Kalman filter is modified to operate on the output signal of a Finite Impulse Response (FIR) filter designed by a plain summation. The frequency estimation unit is independent from the Kalman filter and uses the samples refined by the FIR filter. The frequency estimated is given to the Kalman filter to be used in building the transition matrices. The initial settings for the modified Kalman filter are obtained through a trial and error exercise. Another algorithm again based on the concept of Kalman filtering is proposed in Chapter 4 for the estimation of signal parameters. The Kalman filter is also modified to operate on the output signal of the same FIR filter explained above. Nevertheless, the frequency estimation unit, unlike the one proposed in Chapter 3, is not segregated and it interacts with the Kalman filter. The frequency estimated is given to the Kalman filter and other parameters such as the amplitudes and phase angles estimated by the Kalman filter is taken to the frequency estimation unit. Chapter 5 proposes another algorithm based on the concept of Kalman filtering. This time, the state parameters are obtained through matrix arrangements where the noise level is reduced on the sample vector. The purified state vector is used to obtain a new measurement vector for a basic Kalman filter applied. The Kalman filter used has similar structure to a basic Kalman filter except the initial settings are computed through an extensive math-work with regards to the matrix arrangement utilized. Chapter 6 proposes another algorithm based on the concept of Kalman filtering similar to that of Chapter 3. However, this time the initial settings required for the better performance of the modified Kalman filter are calculated instead of being guessed by trial and error exercises. The simulations results for the parameters of signal estimated are enhanced due to the correct settings applied. Moreover, an enhanced Least Error Square (LES) technique is proposed to take on the estimation when a critical transient is detected in the input signal. In fact, some large, sudden changes in the parameters of the signal at these critical transients are not very well tracked by Kalman filtering. However, the proposed LES technique is found to be much faster in tracking these changes. Therefore, an appropriate combination of the LES and modified Kalman filtering is proposed in Chapter 6. Also, this time the ability of the proposed algorithm is verified on the real data obtained from a prototype test object. Chapter 7 proposes the other algorithm based on the concept of Kalman filtering similar to those of Chapter 3 and 6. However, this time an optimal digital filter is designed instead of the simple summation FIR filter. New initial settings for the modified Kalman filter are calculated based on the coefficients of the digital filter applied. Also, the ability of the proposed algorithm is verified on the real data obtained from a prototype test object. Chapter 8 uses the estimation algorithm proposed in Chapter 7 for the interconnection scheme of a DG to power network. Robust estimates of the signal amplitudes and phase angles obtained by the estimation approach are used in the reference generation of the compensation scheme. Several simulation tests provided in this chapter show that the proposed scheme can very well handle the source and load unbalance, load non-linearity, interharmonic distortion, supply voltage distortion, and synchronism of generated currents or voltages. The purposed compensation scheme also prevents distortion in voltage at the point of common coupling in weak source cases, balances the source currents, and makes the supply side power factor a desired value.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The connection between the activity of the gonadotropic cells of the hypophysis and the neurosecretion in the pre-optico neuro-hypophysial system in different groups of vertebrates has been examined by many authors. It has been established that in many species there exists some kind of synchronism between the sexual cycle and the cellular activity of neurosecretion, a fact that has led to the prevailing idea that gonadotropic activity in the hypophysis is regulated by the hypothalamus. This paper summarises the results of experiments made in this direction on Cyclostomata. The materials for research came from adult individuals of Eudontomyson danfordi Regan taken from the rivers Somes-Rece and Ivo (Harghita district) at different times of the year.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A permanent-magnet motor has been designed for an innovative axial-flow ventricular assist device (VAD), to be placed in the descending aorta, intended to offload the left ventricle and augment renal perfusion in patients with congestive heart failure (CHF). For this application, an intra-aortic impeller with a built-in permanent magnet rotor is driven by an extraaortic stator working in synchronism with the natural heart. To meet this need, a two-dimensional analytical model has been developed in the MATLAB environment to estimate machine parameters; finite element analysis (FEA) has been used to refine the results. A prototype blood pump equipped with an innovative motor designed from the procedure above has been tested in a mock loop representing the human circulatory system. The performance of VAD incorporating the motor is presented. © 2009 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

作为综合治理试验示范区 ,燕儿沟流域在水土保持技术措施配置中 ,坚持以土地利用结构调整为中心的综合治理方略 ,贯彻强化基本农田建设、退耕还林 (草 )的指导思想 ,强调降雨就近拦蓄 ,合理利用土地 ,减少水土流失 ,取得最大效益。同时 ,在配置实施过程中兼顾退耕与基本农田建设同步 ,发展粮食与水土保持同步的主导思想 ,探索生态环境建设的合理模式 ,并取得了可喜成效

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Ciências Farmacêuticas

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Channelled waves in 2-D periodic anisotropic L-C mesh metamaterials have been investigated. Circuit simulation and the newly developed analytical model of a unit cell have demonstrated full qualitative agreement for both lossless and lossy cases. Isofrequencies for a lattice unit cell and the circuit simulations of finite meshes have shown that propagating waves are channelled from a point source as pencil beams which can travel only along specific trajectories. The beam direction varies with frequency, and at the resonance frequency, the phase and group velocities of the travelling wave are orthogonal. The effect of losses was explored, and it was shown that losses cause qualitative changes of the channelled wave type. It was proven that the channelled waves do not follow the laws of geometrical optics (Snell's law, specular reflection, etc.) at the interfaces of L-C meshes but are governed by the conditions of phase synchronism and impedance matching. Only in the special case of dual L-C and C-L meshes with the interface parallel to the axis of rectangular grid excited at the resonance frequency (X=1) do the channels follow the trajectories of optical rays. A planar mesh test cell has been designed and used for retrieving the unit cell L-C parameters from the S-parameter measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The amount of distributed generation connected to the distribution network is increasing. To use this resource more effectively, splitting of the distribution network, or islanding the system, for prevention of power outages is being considered by some utilities. In this paper an islanding method that avoids out-ofsynchronism re-closure is proposed. The island is kept in synchronism with the rest of the utility while it is not electrically connected. This is referred to as synchronous islanded operation. A phase difference control algorithm, developed by the authors, was tested in a single set scenario on a 50-kVA diesel generator using two different governors. These are the “standard product” variable gain governor of the diesel generator and a governor developed by the authors, which utilizes supplementary inputs in addition to engine speed. The results show that phase difference can be controlled within acceptable limits, both in steady state and after load disturbances are applied. The advantages of employing supplementary governor inputs are fully evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Small salient-pole machines, in the range 30 kVA to 2 MVA, are often used in distributed generators, which in turn are likely to form the major constituent of power generation in power system islanding schemes or microgrids. In addition to power system faults, such as short-circuits, islanding contains an inherent risk of out-of-synchronism re-closure onto the main power system. To understand more fully the effect of these phenomena on a small salient-pole alternator, the armature and field currents from tests conducted on a 31.5 kVA machine are analysed. This study demonstrates that by resolving the voltage difference between the machine terminals and bus into direct and quadrature axis components, interesting properties of the transient currents are revealed. The presence of saliency and short time-constants cause intriguing differences between machine events such as out-of-phase synchronisations and sudden three-phase short-circuits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the results of experimental study of passive intermodulation (PIM) generation in microstrip lines with U-shaped and meandered strips, impedance tapers, and strips with the profiled edges. It is shown that the geometrical discontinuities in printed circuits may have a noticeable impact on distributed PIM generation even when their effect is indiscernible in the linear regime measurements. A consistent interpretation of the observed phenomena has been proposed on the basis of the phase synchronism in the four-wave mixing process. The results of this study reveal new features of PIM production important for the design and characterization of low-PIM microstrip circuits. © 2010 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Synchronous islanded operation involves continuously holding an islanded power network in virtual synchronism with the main power system to aid paralleling and avoid potentially damaging out-of-synchronism reclosure. This requires phase control of the generators in the island and the transmission of a reference signal from a secure location on the main power system. Global positioning system (GPS) time-synchronized phasor measurements transmitted via an Internet protocol (IP) are used for the reference signal. However, while offering low cost and a readily available solution for distribution networks, IP communications have variable latency and are susceptible to packet loss, which can make time-critical control applications difficult. This paper investigates the ability of the phase-control system to tolerate communications latency. Phasor measurement conditioning algorithms that can tolerate latency are used in the phase-control loop of a 50-kVA diesel generator. © 2010 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Power system islanding can improve the continuity of power supply. Synchronous islanded operation enables the islanded system to remain in phase with the main power system while not electrically connected, so avoiding out-of-synchronism re-closure. Specific consideration is required for the multiple-set scenario. In this paper a suitable island management system is proposed, with the emphasis being on maximum island flexibility by allowing passive islanding transitions to occur, facilitated by intelligent control. These transitions include: island detection, identification, fragmentation, merging and return-to-mains. It can be challenging to detect these transitions while maintaining syn-chronous islanded operation. The performance of this control system in the presence of a variable wind power in-feed is also examined. A Mathworks SimPowerSystems simulation is used to investigate the performance of the island management system. The benefit and requirements for energy storage, com-munications and distribution system protection for this application are considered.