971 resultados para Specific test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The inverter in a photovoltaic system assures two essential functions. The first is to track the maximum power point of the system IV curve throughout variable environmental conditions. The second is to convert DC power delivered by the PV panels into AC power. Nowadays, in order to qualify inverters, manufacturers and certifying organisms use mainly European and/or CEC efficiency standards. The question arises if these are still representative of CPV system behaviour. We propose to use a set of CPV – specific weighted average and a representative dynamic response to have a better determination of the static and dynamic MPPT efficiencies. Four string-sized commercial inverters used in real CPV plants have been tested.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Proposed transmission smart grids will use a digital platform for the automation of substations operating at voltage levels of 110 kV and above. The IEC 61850 series of standards, released in parts over the last ten years, provide a specification for substation communications networks and systems. These standards, along with IEEE Std 1588-2008 Precision Time Protocol version 2 (PTPv2) for precision timing, are recommended by the both IEC Smart Grid Strategy Group and the NIST Framework and Roadmap for Smart Grid Interoperability Standards for substation automation. IEC 61850-8-1 and IEC 61850-9-2 provide an inter-operable solution to support multi-vendor digital process bus solutions, allowing for the removal of potentially lethal voltages and damaging currents from substation control rooms, a reduction in the amount of cabling required in substations, and facilitates the adoption of non-conventional instrument transformers (NCITs). IEC 61850, PTPv2 and Ethernet are three complementary protocol families that together define the future of sampled value digital process connections for smart substation automation. This paper describes a specific test and evaluation system that uses real time simulation, protection relays, PTPv2 time clocks and artificial network impairment that is being used to investigate technical impediments to the adoption of SV process bus systems by transmission utilities. Knowing the limits of a digital process bus, especially when sampled values and NCITs are included, will enable utilities to make informed decisions regarding the adoption of this technology.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: A novel lateral flow, immunochromatographic assay (LFD) specific for Mycobacterium bovis, the cause of bovine tuberculosis and zoonotic TB, was recently developed at Queen’s University Belfast. The LFD detects whole M. bovis cells, in contrast to other commercially available LFD tests (BD MGITTM TBc ID, SD Bioline TB Ag MPT 64, Capilia TB-Neo kit) which detect MPT64 antigen secreted during growth. The new LFD test has been evaluated in the veterinary context, and its specificity for M. bovis in the broadest sense (i.e. subsp. bovis, subsp. caprae and BCG) and sensitivity to detect M. bovis in positive MGIT™ liquid cultures was demonstrated comprehensively.
Methods: Preliminary work was carried out by researchers at Queen’s University Belfast to optimise sputum sample preparation, estimate the limit of detection (LOD) of the LFD with M. bovis-spiked sputum samples, and check LFD specificity by testing a broad range of non-tuberculous Mycobacterium spp. (NTM) and other bacterial genera commonly encountered in sputum samples (Haemophilus, Klebsiella, Pseudomonas, Staphylococcus). In the Cameroon laboratory direct detection of M. bovis in human sputa was attempted, and 50 positive sputum MGIT™ cultures and 33 cultures of various Mycobacterium spp. originally isolated from human sputa were tested.
Results: Sputum sample preparation consisted of digestion with 1% NALC for 30 min, centrifugation at 3000g for 20 min, PBS wash, centrifugation again, and pellet resuspended in KPL blocking buffer before 100 µl was applied to the LFD. The LOD of the LFD applied to M. bovis-spiked sputum was estimated to be 104 CFU/ml. A small number of confirmed Ziehl-Neelsen ‘3+’ M. bovis positive sputum samples were tested directly but no positive LFD results were obtained. All of the sputum MGIT™ cultures and mycobacterial cultures (including M. tuberculosis, M. africanum, M. bovis, M. intracellulare, M. scrofulaceum, M. fortuitum, M. peregrinum, M. interjectum) tested LFD negative when read after 15 min except for the M. bovis cultures, thereby confirming specificity of LFD for M. bovis in the clinical microbiology context.
Conclusions: Results indicate that the ‘Rapid-bTB’ LFD is a very specific test, able to differentiate M. bovis from M. tuberculosis, M. africanum, and a range of NTM isolated from human sputa in MGITTM liquid cultures. However, the LFD lacks sufficient sensitivity to be applied earlier in the diagnostic process to directly test human sputa.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aims of this study were to 1) determine the relationship between performance on the court-based TIVRE-Basket® test and peak aerobic power determined from a criterion lab-based incremental treadmill test and 2) to examine the test-retest reliability of the TIVRE-Basket® test in elite male basketball players. To address aim 1, 36 elite male basketball players (age 25.2 + 4.7 years, weight 94.1 + 11.4 kg, height 195.83 + 9.6 cm) completed a graded treadmill exercise test and the TIVRE-Basket® within 72 hours. Mean distance recorded during the TIVRE-Basket® test was 4001.8 + 176.4m, and mean VO2 peak was 54.7 + 2.8 ml.kg.min-1, and the correlation between the two parameters was r=0.824 (P= <0.001). Linear regression analysis identified TIVRE-Basket® distance (m) as the only unique predictor of VO2 peak in a single variable plus constant model: VO2 peak = 2.595 + ((0.13* TIVRE-Basket® distance (m)). Performance on the TIVRE-Basket® test accounted for 67.8% of the variance in VO2 peak (t=8.466, P=<.001, 95% CI 0.01 - 0.016, SEE 1.61). To address aim 2, 20 male basketball players (age 26.7±4.2; height 1.94±0.92; weight 94.0±9.1) performed the TIVRE-Basket® test on two occasions. There was no significant difference in total distance covered between Trial 1 (4138.8 + 677.3m) and Trial 2 (4188.0 + 648.8m; t = 0.5798, P = 0.5688). Mean difference between trials was 49.2 + 399.5m, with an ICC of 0.85 suggesting a moderate level of reliability. Standardised TEM was 0.88%, representing a moderate degree of trial to trial error, and the CV was 6.3%. The TIVRE-Basket® test therefore represents a valid and moderately reliable court-based sport-specific test of aerobic power for use with individuals and teams of elite level male basketball players. Future research is required to ascertain its validity and reliability in other basketball populations e.g. across age groups, at different levels of competition, in females and in different forms of the game e.g. wheelchair basketball.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

El objetivo de este estudio fue realizar una prueba de validez diagnostica del test neural 1 para el diagnóstico del Síndrome de Túnel del Carpo (STC) utilizando como prueba de referencia o de oro el test de conducción nerviosa. En este estudio participaron 115 sujetos, 230 manos con sospecha clínica de STC quienes fueron evaluados con el test de conducción nerviosa y el test neural 1. Se encontró una sensibilidad del 93.0% (IC 95%:88,21-96,79) y una especificidad del 6,67% (IC 95%:0,0-33,59), razón de verosimilitud positiva fue de 1,00 y razón de verosimilitud negativa de 1,05. Valor predictivo positivo de 86,9% y un valor predictivo negativo de 12,5%. Se concluye que el test neural 1 es una prueba clínica de alta sensibilidad y baja especificidad de gran utilidad para el monitoreo e identificación del STC. Es un procedimiento para el diagnóstico clínico de bajo costo que puede incluirse en los exámenes de rutina de los trabajadores como complemento a las pruebas clínicas sugeridas por las Gatiso para dar mayor precisión a la identificación temprana del STC. Se sugiere combinarla con otros test de mayor especificidad para ser aplicada en trabajadores en condiciones de riesgo o que presenten síntomas en miembros superiores y realizar otros estudios en donde participen sujetos sin diagnóstico clínico del STC.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Avaliou-se a reação de contraimunoeletroforese (CIE) como teste gênero-específico para diagnóstico da leptospirose suína, usando-se três extratos solúveis de Leptospira sp, sorovares pomona, icterohaemorrhagiae e patoc, obtidos pelo tratamento com Triton X-100 a quente e aplicados a amostras de soro de suínos subdivididos em três grupos: Grupo 1, 10 suínos experimentalmente infectados com estirpe Pomona; Grupo 2, 50 suínos naturalmente infectados e Grupo 3, controle. As amostras de soros foram submetidas à reação de CIE e os resultados comparados aos da Soroaglutinação Microscópica (SAM), técnica de referência pela WHO. Os Grupos 1 e 3 foram monitorados por 93 dias após a inoculação (p.i.). Pela SAM a soroconversão do Grupo 1 ocorreu por volta do 10º dia p.i., enquanto pela CIE, empregando-se qualquer extrato antigênico, foi anterior à SAM. Quando a CIE foi realizada frente a antigeno homólogo à infecção, seus resultados foram equivalentes aos da SAM, não se verificando o mesmo frente aos antígenos heterólogos. Neste aspecto, os Grupos 1 e 3 mostraram comportamento diferente pois não houve diferença significativa entre os resultados da CIE frente aos três antígenos, o que poderia significar serem independentes do sorovar responsável pelo surto ou infectante. Embora a CIE seja segura, rápida, de fácil execução, de baixo custo e ideal para análise em grande escala de amostras, revelou-se de limitada capacidade gênero-específica, o que não é desejavel para testes de triagem de campo; mas poderia ser útil na detecção precoce de resposta sorológica em relação à SAM.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose. - The purposes of this study were: i) to compare the physiological responses measured during a specific table tennis incremental test with the physiological responses measured during cycling, arm cranking, and treadmill running tests; and ii) to verify the accuracy of table tennis performance prediction based on the physiological responses from these tests.Methods. - Eleven national level male table tennis players participated in the study and undertook incremental tests using ergometers. Table tennis performance was defined as the ranking obtained during a simulated tournament between the participants.Results. - In general, peak values for physiological variables (e.g., (V) over dotO(2PEAK) and [La]PEAK) were significantly lower (P < 0.05) in the specific test (e.g., (V) over dotO(2PEAK) = 39.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 6.4 +/- 0.5 mmol.L-1) than during cycling (e.g., (V) over dotO(2PEAK) = 41.3 +/- 1.4 ml.kg(-1) per minute and [La]PEAK = 10.2 +/- 0.7 mmol.L-1) or running (e.g., (V) over dotO(2PEAK) = 43.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 10.0 +/- 0.7 mmol.L-1), but higher than during arm cranking (e.g., (V) over dotO(2PEAK) = 26.6 +/- 1.6 ml.kg(-1) per minute and [La]PEAK = 8.9 +/- 0.6 mmol.L-1). At respiratory compensation point intensity (RCP), only the variables measured on arm cranking were lower (P < 0.05) than on the other ergometers. Stepwise multiple regression analysis showed significant correlation between table tennis performance and lactate concentration ([La]) and also rate of perceived effort (RPE) at RCP during cycling (r = 0.89; P < 0.05).Conclusion. - In conclusion, the significant differences obtained between the specific and laboratory ergometers demonstrate the need to use a specific test to measure physiological parameters in table tennis and the physiological parameters measured, independent of the ergometer used, are unable to predict table tennis performance. (C) 2013 Elsevier Masson SAS. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background—Palpation is an important clinical test for jumper's knee. Objectives—To (a) test the reproducibility of palpation tenderness, (b) evaluate the sensitivity and specificity of palpation in subjects with clinical symptoms of jumper's knee, and (c) determine whether tenderness to palpation may serve as a useful screening test for patellar tendinopathy. The yardstick for diagnosis of patellar tendinopathy was ultrasonographic abnormality. Methods—In 326 junior symptomatic and asymptomatic athletes' tendons, palpation was performed by a single examiner before ultrasonographic examination by a certified ultrasound radiologist. In 58 tendons, palpation was performed twice to test reliability. Tenderness to palpation was scored on a scale from 0 to 3 where 0 represented no pain, and 1, 2, and 3 represented mild, moderate, and severe tenderness respectively. Results—Patellar tendon palpation was a reliable examination for a single examiner (Pearson r = 0.82). In symptomatic tendons, the positive predictive value of palpation was 68%. As a screening examination in asymptomatic subjects, the positive predictive value of tendon palpation was 36–38%. Moderate and severe palpation tenderness were better predictors of ultrasonographic tendon pathology than absent or mild tenderness (p<0.001). Tender and symptomatic tendons were more likely to have ultrasound abnormality than tenderness alone (p<0.01). Conclusions—In this age group, palpation is a reliable test but it is not cost effective in detecting patellar tendinopathy in a preparticipation examination. In symptomatic tendons, palpation is a moderately sensitive but not specific test. Mild tenderness in the patellar tendons in asymptomatic jumping athletes should be considered normal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Failures on rolling element bearings usually originate from cracks that are detectable even in their early stage of propogation by properly analyzing vibration signals measured in the proximity of the bearing. Due to micro-slipping in the roller-races contact, damage-induced vibration signals belong to the family of quasi-periodic signals with a strong second order cyclostationary component. Cyclic coherence and its integrated form are widely considered as the most suitable tools for bearing fault diagnostics and their theoretical bases have been already consolidated. This paper presents how to correctly set the parameters of the cyclostationary analysis tool to be implemented in an automatable algorithm. In the first part of the paper some general guidelines are provided for the specific application. These considerations are further verified, applying cyclostationary tools to data collected in an experimental campaign on a specific test-rig.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Rolling element bearings are the most critical components in the traction system of high speed trains. Monitoring their integrity is a fundamental operation in order to avoid catastrophic failures and to implement effective condition based maintenance strategies. Generally, diagnostics of rolling element bearings is usually performed by analyzing vibration signals measured by accelerometers placed in the proximity of the bearing under investigation. Several papers have been published on this subject in the last two decades, mainly devoted to the development and assessment of signal processing techniques for diagnostics. The experimental validation of such techniques has been traditionally performed by means of laboratory tests on artificially damaged bearings, while their actual effectiveness in specific industrial applications, particularly in rail industry, remains scarcely investigated. This paper is aimed at filling this knowledge gap, by addressing the diagnostics of bearings taken from the service after a long term operation on the traction system of a high speed train. Moreover, in order to test the effectiveness of the diagnostic procedures in the environmental conditions peculiar to the rail application, a specific test-rig has been built, consisting of a complete full-scale train traction system, able to reproduce the effects of wheeltrack interaction and bogie-wheelset dynamics. The results of the experimental campaign show that suitable signal processing techniques are able to diagnose bearing failures even in this harsh and noisy application. Moreover, the most suitable location of the sensors on the traction system is proposed, in order to limit their number.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main purpose of the research was to illustrate chemistry matriculation examination questions as a summative assessment tool, and represent how the questions have evolved over the years. Summative assessment and its various test item classifications, Finnish goal-oriented curriculum model, and Bloom’s Revised Taxonomy of Cognitive Objectives formed the theoretical framework for the research. The research data consisted of 257 chemistry questions from 28 matriculation examinations between 1996 and 2009. The analysed test questions were formulated according to the national upper secondary school chemistry curricula 1994, and 2003. Qualitative approach and theory-driven content analysis method were employed in the research. Peer review was used to guarantee the reliability of the results. The research was guided by the following questions: (a) What kinds of test item formats are used in chemistry matriculation examinations? (b) How the fundamentals of chemistry are included in the chemistry matriculation examination questions? (c) What kinds of cognitive knowledge and skills do the chemistry matriculation examination questions require? The research indicates that summative assessment was used diversely in chemistry matriculation examinations. The tests included various test item formats, and their combinations. The majority of the test questions were constructed-response items that were either verbal, quantitative, or experimental questions, symbol questions, or combinations of the aforementioned. The studied chemistry matriculation examinations seldom included selected-response items that can be either multiple-choice, alternate choice, or matching items. The relative emphasis of the test item formats differed slightly depending on whether the test was a part of an extensive general studies battery of tests in sciences and humanities, or a subject-specific test. The classification framework developed in the research can be applied in chemistry and science education, and also in educational research. Chemistry matriculation examinations are based on the goal-oriented curriculum model, and cover relatively well the fundamentals of chemistry included in the national curriculum. Most of the test questions related to the symbolism of chemical equation, inorganic and organic reaction types and applications, the bonding and spatial structure in organic compounds, and stoichiometry problems. Only a few questions related to electrolysis, polymers, or buffer solutions. None of the test questions related to composites. There were not any significant differences in the emphasis between the tests formulated according to the national curriculum 1994 or 2003. Chemistry matriculation examinations are cognitively demanding. The research shows that the majority of the test questions require higher-order cognitive skills. Most of the questions required analysis of procedural knowledge. The questions that only required remembering or processing metacognitive knowledge, were not included in the research data. The required knowledge and skill level varied slightly between the test questions in the extensive general studies battery of tests in sciences and humanities, and subject-specific tests administered since 2006. The proportion of the Finnish chemistry matriculation examination questions requiring higher-order cognitive knowledge and skills is very large compared to what is discussed in the research literature.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Here we demonstrate a novel application that employs the ion exchange properties of conducting polymers (CP) to modulate the detection window of a CP based biosensor under electrical stimuli. The detection window can be modulated by electrochemically controlling the degree of swelling of the CP associated with ion transport in and out of the polymer. We show that the modulation in the detection window of a caffeine imprinted polypyrrole biosensor, and by extension other CP based biosensors, can be achieved with this mechanism. Such dynamic modulation in the detection window has great potential for the development of smart biosensors, where the sensitivity of the sensor can be dynamically optimized for a specific test solution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Persistent polyclonal B cell lymphocytosis (PPBL) is a rare condition characterized by increased IgM and large excess of B cells with an IgD(+) CD27(+) phenotype. In normal individuals, these cells play a central role in the defense against pneumococcal infection. So far, few studies have characterized humoral immune responses in PPBL patients. We therefore measured IgG directed against S. pneumoniae antigens in a 51 yr-old woman with PPBL before and after vaccination with a pneumococcal 23-valent polysaccharide vaccine. METHODS: Antibodies against pneumococcal antigens were measured first with an overall immunoassay using microplates coated with the 23-valent pneumococcal vaccine. A serotype-specific test was also performed according to the WHO consensus protocol. RESULTS: Despite a large number of IgD(+) CD27(+) cells, our patient had low baseline titers of IgG directed against pneumococcal antigens and did not significantly respond to a 23-valent polysaccharide vaccine against S. pneumoniae. On the contrary, she had good titers of IgG directed against tetanus toxoid. CONCLUSION: IgM(+) IgD(+) CD27(+) cells which accumulate in this patient with typical PPBL patient failed to perform IgG isotype switch after a polysaccharide vaccine. The potential mechanisms and relationships with the main features of PPBL are discussed. Further studies on a larger number of similar patients are needed.