994 resultados para Skin Permeability Coefficients


Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the most important determinants of dermatological and systemic penetration after topical application is the delivery or flux of solutes into or through the skin. The maximum dose of solute able to be delivered over a given period of time and area of application is defined by its maximum flux (J(max), mol per cm(2) per h) from a given vehicle. In this work, J(max) values from aqueous solution across human skin were acquired or estimated from experimental data and correlated with solute physicochemical properties. Whereas epidermal permeability coefficients (k(p)) are optimally correlated to solute octanol-water partition coefficient (K-ow) and molecular weight (MW) was found to be the dominant determinant of J(max) for this literature data set: log J(max)=-3.90-0.0190MW (n=87, r(2)=0.847, p

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A new class of high-performance polymers [poly(phenylene-co-naphthalimide)s] was prepared through the Ni(0) catalytic coupling of N-(4-chloro-2-trifluromethylphenyl)-5-chloro-1,8-naphthalimide and 2,5-dichlorobenzophenone. The resulting copolymers exhibited high molecular weights (high inherent viscosities) and a combination of desirable properties such as good solubility in dipolar aprotic solvents, film-forming capability, and mechanical properties. The glass-transition temperatures of the copolymers ranged from 320 to 403 degrees C and increased as the content of the naphthalimide moiety increased. Tough polymer films, obtained via casting from N-methylpyrrolidone solutions, had tensile strengths of 64-107 MPa and tensile moduli of 3.4-4.7 GPa. The gas permeability coefficients of the copolymers were measured for H-2, CO2, O-2, CH4, and N-2. They showed oxygen permeability coefficients and permeability selectivity of oxygen to nitrogen (permeability coefficient for O-2/permeability coefficient for N-2) in the ranges of 1.39-4.31 and 4.92-5.38 barrer, respectively.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Gas permeability coefficients of a series of aromatic polyetherimides, which were prepared from 1,4-bis(3,4-dicarboxyphenoxy) benzene dianhydride (HQDPA) with various aromatic diamines, to H-2, O-2 and N-2 have been measured under 7 atm and at the temperature range 30-100 degrees C. A significant change in the permeability and permselectivity resulting from the systematic variation in chemical structure of the polyetherimides was found. Among the polyetherimides, that were prepared from phenylenediamine and methyl substituted phenylenediamines, the increase of permeability is accompanied by a decrease of permselectivity. The polyetherimides that were prepared from 3,5-diaminobenzoic esters have lower permselectivity than the others. However, the polyetherimide from 3,5-diaminobenzoic acid possesses much higher permselectivity than the others due to cross-linking. Copyright (C) 1996 Elsevier Science Ltd

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Permeability coefficients of H-2, O-2, and N2 were measured under 10 atm at the temperature from ambient temperature up to 150 degrees C in a series of structurally different aromatic homo- and copolyimides, which were prepared from 4,4'-oxydianiline (ODA) or 4,4'-methylene dianiline (MDA) with various aromatic dianhydrides. The study shows that the molecular structure of the polyimides strongly influences gas permeability and permselectivity. As a result, the permeability coefficients of the polyimide membranes for each gas vary by over two orders of magnitude. In general, among the polyimide membranes studied, the increase in permeability of polymers is accompanied by the decrease in permselectivity, and the MDA-based polyimide membranes have higher permeability than ODA-based ones. Among the polyimides prepared from bridged dianhydrides, the permeability coefficients to H-2, O-2, and N-2 are progressively increased in the order BPDA < BTDA < ODPA similar to TDPA < DSDA ( SiDA < 6FDA, while H-2/N-2 and O-2/N-2 permselectivity coefficients are progressively decreased in the same order. The copolyimide membranes, which were prepared from 3,3',4,4' biphenyltetracarboxylic dianhydride (BPDA), bis(3,4-dicarboxyphenyl)dimethylsilane dianhydride (SiDA), and ODA, have favorable gas separation properties and are useful for H-2/N-2 separation applications. (C) 1996 John Wiley & Sons, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Gas permeability coefficients of a series of aromatic polyetherimides, which were prepared from 1,4-bis(3,4-dicarboxyphenoxy) benzene dianhydride (HQDPA) and various aromatic diamines, to H-2, CO2, O-2, N-2 and CH4 have been measured under 7 atm pressure and over the temperature range 30-150 degrees C. A significant change in permeability and permselectivity, which resulted from a systematic variation in chemical structure of the polyetherimides, was found. Generally, increases in permeability of the polyetherimides are accompanied by decreases in permselectivity. The order of decrease of the permeability coefficients is as follows: HQDPA-IPDA > HQDPA-DDS > HQDPA-MDA > HQDPA-ODA > HQDPA-DABP > HQDPA-BZD. However, HQDPA-DMoBZD and HQDPA-DMoMDA, with bulky methoxy side-groups on the aromatic rings of the diamine residue, display both high permeability coefficients and high permselectivity. The favourable gas separation property, excellent thermal and chemical stability, and high mechanical strength make HQDPA-DMoBZD and HQDPA-DMoMDA promising candidates for membrane-based gas separation applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Gas permeability coefficients of a series of aromatic polyetherimides prepared from 1,4-bis(3,4-dicarboxyphenoxy) benzene dianhydride (HQDPA) and four (methylene dianiline)s with a methyl side group to H-2, CO2, O-2, N-2, and CH4 were measured under 7 atm and within a temperature range from 30 to 150 degrees C. The gas permeabilities and permselectivities of these polymers were compared with those of the HQDPA-based polyetherimides from methylene dianiline (MDA) and isopropylidene dianiline (IPDA). The number and position of the methyl side groups on the benzene rings of the diamine residues strongly affect the gas permeabilities and permselectivities of the HQDPA-based polyetherimides. The gas permeability of the polyetherimide progressively increases with an increase in the number of the methyl side groups. Both the gas permeability and permselectivity of the polyetherimides with methyl side groups are higher than those of HQDPA-MDA. The polyetherimide prepared from 3,3'-dimethyl 4,4'-methylene dianiline (DMMDA1) possesses both higher permeability and permselectivity than the polyetherimides prepared from 2,2'-dimethyl 4,4'-methylene dianiline (DMMDA2). However, two of the polyetherimides prepared 2,2',3,3'-tetramethyl 4,4'-methylene dianiline (TMMDA1) or 2,2', 5,5'-tetramethyl 4,4'-methylene dianiline (TMMDA2) possess almost the same gas permeability and permselectivity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The introduction of skin sub-stiffening features has the potential to modify the local stability and fatigue crack growth performance of stiffened panels. Proposed herein is a method to enable initial static strength sizing of panels with such skin sub-stiffening features. The method uses bespoke skin buckling coefficients, automatically generated by Finite Element analysis and thus limits the modification to the conventional aerospace panel initial sizing process. The approach is demonstrated herein and validated for prismatic sub-stiffening features. Moreover, examination of the generated buckling coefficient data illustrates the influence of skin sub-stiffening on buckling behavior, with static strength increases typically corresponding to a reduction in the number of initial skin longitudinal buckle half-waves.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The non-destructive evaluation of the water permeability of concrete structures is a long standing challenge, principally due to the difficulty of achieving a uni-direction flow for computing the water permeability coefficient. The use of a guard ring (GR) was originally proposed for the in situ sorptivity test, but little information can be found for the water permeability test. In this study, the effect of a GR was carefully examined through the flow simulation, which was verified by carrying out experiments. It was observed that the GR can confine the flow near the surface, but cannot achieve a uni-directional flow across the whole depth of flow. To achieve a better performance, it is essential to consider the effects of the size of the inner seal and the GR and the significant interaction between these two. The analysis of the experimental data has indicated that the GR influences the flow for porous concretes, but there is no significant effect for dense concretes. Further investigation, validated using the flow-net theory, has shown a strong correlation between the water permeability coefficients obtained with the GR (K w-GR) and without it (K w-No GR), suggesting that one dimensional flow is not essential for interpreting data for site tests. Another practical issue was that more than 30 % of the tests with GR failed due to the difficulty of achieving a good seal between the inner and the outer chambers. Based on the work reported in this paper, a new water permeability test is proposed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Consumers nowadays are playing an active role in their health-care. A special case is the increasing number of women, who are reluctant to use exogenous hormone therapy for the treatment of menopausal symptoms and are looking for complementary therapies. However, food supplements are not clearly regulated in Europe. The EFSA has only recently begun to address the issues of botanical safety and purity regulation, leading to a variability of content, standardization, dosage, and purity of available products. In this study, isoflavones (puerarin, daidzin, genistin, daidzein, glycitein, genistein, formononetin, prunetin, and biochanin A) from food supplements (n = 15) for menopausal symptoms relief are evaluated and compared with the labelled information. Only four supplements complied with the recommendations made by the EC on the tolerable thresholds. The intestinal bioavailability of these compounds was investigated using Caco-2 cells. The apparent permeability coefficients of the selected isoflavonoids across the Caco-2 cells were affected by the isoflavone concentration and product matrix.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The permeability of the lung is critical in determining the disposition of inhaled drugs and the respiratory epithelium provides the main physical barrier to drug absorption. The 16HBE14o- human bronchial epithelial cell line has been developed recently as a model of the airway epithelium. In this study, the transport of 10 low molecular weight compounds was measured in the 16HBE14o- cell layers, with apical to basolateral (absorptive) apparent permeability coefficients (P(app)) ranging from 0.4 x 10(-6)cms(-1) for Tyr-D-Arg-Phe-Phe-NH(2) to 25.2x10(-6)cms(-1) for metoprolol. Permeability in 16HBE14o- cells was found to correlate with previously reported P(app) in Caco-2 cells and absorption rates in the isolated perfused rat lung (k(a,lung)) and the rat lung in vivo (k(a,in vivo)). Log linear relationships were established between P(app) in 16HBE14o- cells and P(app) in Caco-2 cells (r(2)=0.82), k(a,lung) (r(2)=0.78) and k(a,in vivo) (r(2)=0.68). The findings suggest that permeability in 16HBE14o- cells may be useful to predict the permeability of compounds in the lung, although no advantage of using the organ-specific cell line 16HBE14o- compared to Caco-2 cells was found in this study.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The skin friction coefficient on the surface of a rotating yarn package affects the power required to drive the package. This paper examines the relationship between the skin friction coefficient on the package surface and its diameter and rotating speed, based on the fundamentals of aerodynamics and the experimental results of power consumption. Skin friction coefficients on the surfaces of an airplane, car top, and yarn package are discussed. The results indicate that the skin friction coefficient on the package surface without hairiness depends on the package diameter and spindle speed only. The skin friction coefficient on the yarn package surface is about three times that on the top surface of a car, and is about twenty times that on an airplane surface. The power consumed to overcome skin friction drag is more than that consumed to drive the spindle if the spindle speed is very slow. However, the situation reverses when the spindle speed is fast.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effect of radiation on natural convection flow from an isothermal circular cylinder has been investigated numerically in this study. The governing boundary layer equations of motion are transformed into a non-dimensional form and the resulting nonlinear systems of partial differential equations are reduced to convenient boundary layer equations, which are then solved numerically by two distinct efficient methods namely: (i) implicit finite differencemethod or the Keller-Box Method (KBM) and (ii) Straight Forward Finite Difference Method (SFFD). Numerical results are presented by velocity and temperature distribution of the fluid as well as heat transfer characteristics, namely the shearing stress and the local heat transfer rate in terms of the local skin-friction coefficient and the local Nusselt number for a wide range of surface heating parameter and radiation-conduction parameter. Due to the effects of the radiation the skin-friction coefficients as well as the rate of heat transfer increased and consequently the momentum and thermal boundary layer thickness enhanced.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Laminar magnetohydrodynamic (MHD) natural convection flow from an isothermal sphere immersed in a fluid with viscosity proportional to linear function of temperature has been studied. The governing boundary layer equations are transformed into a non-dimensional form and the resulting nonlinear system of partial differential equations are reduced to convenient form which are solved numerically by two very efficient methods, namely, (i) Implicit finite difference method together with Keller box scheme and (ii) Direct numerical scheme. Numerical results are presented by velocity and temperature distribution, streamlines and isotherms of the fluid as well as heat transfer characteristics, namely the local skin-friction coefficients and the local heat transfer rate for a wide range of magnetohydrodynamic paramagnet and viscosity-variation parameter.