992 resultados para Setup


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis investigates metallic nanostructures exhibiting surface plasmon resonance for the amplification of fluorescence signal in sandwich immunoassays. In this approach, an analyte is captured by an antibody immobilized on a plasmonic structure and detected by a subsequently bound fluorophore labeled detection antibody. The highly confined field of surface plasmons originates from collective charge oscillations which are associated with high electromagnetic field enhancements at the metal surface and allow for greatly increased fluorescence signal from the attached fluorophores. This feature allows for improving the signal-to-noise ratio in fluorescence measurements and thus advancing the sensitivity of the sensor platform. In particular, the thesis presents two plasmonic nanostructures that amplify fluorescence signal in devices that rely on epifluorescence geometry, in which the fluorophore absorbs and emits light from the same direction perpendicular to the substrate surface.rnThe first is a crossed relief gold grating that supports propagating surface plasmon polaritons (SPPs) and second, gold nanoparticles embedded in refractive index symmetric environment exhibiting collective localized surface plasmons (cLSPs). Finite-difference time-domain simulations are performed in order to design structures for the optimum amplification of established Cy5 and Alexa Fluor 647 fluorophore labels with the absorption and emission wavelengths in the red region of spectrum. The design takes into account combined effect of surface plasmon-enhanced excitation rate, directional surface plasmon-driven emission and modified quantum yield for characteristic distances in immunoassays. Homebuilt optical instruments are developed for the experimental observation of the surface plasmon mode spectrum, measurements of the angular distribution of surface plasmon-coupled fluorescence light and a setup mimicking commercial fluorescence reading systems in epifluorescence geometry.rnCrossed relief grating structures are prepared by interference lithography and multiple copies are made by UV nanoimprint lithography. The fabricated crossed diffraction gratings were utilized for sandwich immunoassay-based detection of the clinically relevant inflammation marker interleukin 6 (IL-6). The enhancement factor of the crossed grating reached EF=100 when compared to a flat gold substrate. This result is comparable to the highest reported enhancements to date, for fluorophores with relatively high intrinsic quantum yield. The measured enhancement factor excellently agrees with the predictions of the simulations and the mechanisms of the enhancement are explained in detail. Main contributions were the high electric field intensity enhancement (30-fold increase) and the directional fluorescence emission at (4-fold increase) compared to a flat gold substrate.rnCollective localized surface plasmons (cLSPs) hold potential for even stronger fluorescence enhancement of EF=1000, due to higher electric field intensity confinement. cLSPs are established by diffractive coupling of the localized surface plasmon resonance (LSPR) of metallic nanoparticles and result in a narrow resonance. Due to the narrow resonance, it is hard to overlap the cLSPs mode with the absorption and emission bands of the used fluorophore, simultaneously. Therefore, a novel two resonance structure that supports SPP and cLSP modes was proposed. It consists of a 2D array of cylindrical gold nanoparticles above a low refractive index polymer and a silver film. A structure that supports the proposed SPP and cLSP modes was prepared by employing laser interference lithography and the measured mode spectrum was compared to simulation results.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diese Arbeit befasst sich mit der photoinduzierten Erzeugung neutraler Pionen, sehr nahe an der Schwellenenergie. Dabei werden zwei Ziele verfolgt: Zum einen die Überprüfung von Vorhersagen dieser effektiven Theorien und Modelle, zum anderen werden hier erstmals alle relevanten Partialwellenamplituden modellunabhängig aus gemessenen Observablen bestimmt. Diese Methode soll in Zukunft auch bei höheren Energien im Bereich der Nukleonresonanzen Anwendung finden. rnrnKonkret wird die Durchführung und Analyse eines Experiments vorgestellt, welches am Mainzer Mikrotron (MAMI) in den Jahren 2010 bis 2013 mit zirkular polarisiertem Photonenstrahl stattfand. Der Photonenstrahl wurde an einer Anlage zur Erzeugung energiemarkierter Bremsstrahlung aus dem Elektronenstrahl von MAMI gewonnen. Zum Nachweis der Reaktionsprodukte diente das hermetische 4pi CB/TAPS-Detektorsystem. Erstmalig standen bei derartigen Messungen auch transversal polarisierte Protonen zur Verfügung. Dazu wird Butanol in einer speziellen Apparatur dynamisch polarisiert. Molekularer Wasserstoff lässt sich aufgrund der para-Konfiguration nicht polarisieren. Wegen der Verwendung von Butanol als Targetmaterial, bei dem weniger als 5% aller erzeugten Pionen an polarisierten Protonen produziert wurden, ist die Behandlung des Untergrunds eine zentrale Aufgabe. rnrnEs werden zwei Methoden der Untergrundseparation vorgestellt, wovon die bessere in der Analyse angewendet wurde. Abschließend findet eine ausführliche Bewertung systematischer Fehler statt.rnrnDie erstmalige Verwendung transversal polarisierter Protonen ermöglicht den Zugang zu bisher nicht gemessenen Spin"=Freiheitsgraden. In Kombination mit einem komplementären Vorläufer-Experiment aus dem Jahr 2008 mit linear polarisiertem Photonenstrahl konnten aus den gewonnenen Daten erstmals alle komplexen s- und p-Partialwellenamplituden modellunabhängig bestimmt werden. rnrnDarüber hinaus wurden im Rahmen dieser Arbeit wesentliche Verbesserungen am apparativen Aufbau erzielt. Beispiele sind ein Elektronenstrahl-Polarimeter, ein zellularer CB-Multiplizitätstrigger, sowie signifikante Verbesserungen der Datennahmeelektronik und des Triggersystems, die teilweise in dieser Arbeit vorgestellt werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermoelektrizität beschreibt die reversible Beeinflussung und Wechselwirkung von Elektrizität und Temperatur T in Systemen abseits des thermischen Gleichgewichtes. In diesen führt ein Temperaturgradient entlang eines thermoelektrischen Materials zu einem kontinuierlichen Ungleichgewicht in der Energieverteilung der Ladungsträger. Dies hat einen Diffusionsstrom der energiereichen Ladungsträger zum kalten Ende und der energiearmen Ladungsträger zum heißen Ende zur Folge. Da in offenen Stromkreisen kein Strom fließt, wird ein Ungleichgewicht der Ströme über das Ausbilden eines elektrischen Feldes kompensiert. Die dadurch entstehende Spannung wird als Seebeck Spannung bezeichnet. Über einen geeigneten Verbraucher, folgend aus dem Ohm'schen Gesetz, kann nun ein Strom fließen und elektrische Energie gewonnen werden. Den umgekehrten Fall beschreibt der sogenannte Peltier Effekt, bei dem ein Stromfluss durch zwei unterschiedliche miteinander verbundene Materialien ein Erwärmen oder Abkühlen der Kontaktstelle zur Folge hat. Die Effizienz eines thermoelektrischen Materials kann über die dimensionslose Größe ZT=S^2*sigma/kappa*T charakterisiert werden. Diese setzt sich zusammen aus den materialspezifischen Größen der elektrischen Leitfähigkeit sigma, der thermischen Leitfähigkeit kappa und dem Seebeck Koeffizienten S als Maß der erzeugten Spannung bei gegebener Temperaturdifferenz. Diese Arbeit verfolgt den Ansatz glaskeramische Materialien mit thermoelektrischen Kristallphasen zu synthetisieren, sie strukturell zu charakterisieren und ihre thermoelektrischen Eigenschaften zu messen, um eine Struktur-Eigenschaft Korrelation zu erarbeiten. Hierbei werden im Detail eine elektronenleitende (Hauptphase SrTi_xNb_{1-x}O_3) sowie eine löcherleitende Glaskeramik (Hauptphase Bi_2Sr_2Co_2O_y) untersucht. Unter dem Begriff Glaskeramiken sind teilkristalline Materialien zu verstehen, die aus Glasschmelzen durch gesteuerte Kristallisation hergestellt werden können. Über den Grad der Kristallisation und die Art der ausgeschiedenen Spezies an Kristallen lassen sich die physikalischen Eigenschaften dieser Systeme gezielt beeinflussen. Glaskeramiken bieten, verursacht durch ihre Restglasphase, eine niedrige thermische Leitfähigkeit und die Fermi Energie lässt sich durch Dotierungen in Richtung des Leitungs- oder Valenzbands verschieben. Ebenso besitzen glaskeramische Materialien durch ihre Porenfreiheit verbesserte mechanische Eigenschaften gegenüber Keramiken und sind weniger anfällig für den Einfluss des Sauerstoffpartialdruckes p_{O_2} auf die Parameter. Ein glaskeramisches und ein gemischt keramisch/glaskeramisches thermoelektrisches Modul aus den entwickelten Materialien werden konzipiert, präpariert, kontaktiert und bezüglich ihrer Leistung vermessen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study a novel method MicroJet reactor technology was developed to enable the custom preparation of nanoparticles. rnDanazol/HPMCP HP50 and Gliclazide/Eudragit S100 nanoparticles were used as model systems for the investigation of effects of process parameters and microjet reactor setup on the nanoparticle properties during the microjet reactor construction. rnFollowing the feasibility study of the microjet reactor system, three different nanoparticle formulations were prepared using fenofibrate as model drug. Fenofibrate nanoparticles stabilized with poloxamer 407 (FN), fenofibrate nanoparticles in hydroxypropyl methyl cellulose phthalate (HPMCP) matrix (FHN) and fenofibrate nanoparticles in HPMCP and chitosan matrix (FHCN) were prepared under controlled precipitation using MicroJet reactor technology. Particle sizes of all the nanoparticle formulations were adjusted to 200-250 nm. rnThe changes in the experimental parameters altered the system thermodynamics resulting in the production of nanoparticles between 20-1000 nm (PDI<0.2) with high drug loading efficiencies (96.5% in 20:1 polymer:drug ratio).rnDrug releases from all nanoparticle formulations were fast and complete after 15 minutes both in FaSSIF and FeSSIF medium whereas in mucodhesiveness tests, only FHCN formulation was found to be mucoadhesive. Results of the Caco-2 studies revealed that % dose absorbed values were significantly higher (p<0.01) for FHCN in both cases where FaSSIF and FeSSIF were used as transport buffer.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die rasante Entwicklung der Computerindustrie durch die stetige Verkleinerung der Transistoren führt immer schneller zum Erreichen der Grenze der Si-Technologie, ab der die Tunnelprozesse in den Transistoren ihre weitere Verkleinerung und Erhöhung ihrer Dichte in den Prozessoren nicht mehr zulassen. Die Zukunft der Computertechnologie liegt in der Verarbeitung der Quanteninformation. Für die Entwicklung von Quantencomputern ist die Detektion und gezielte Manipulation einzelner Spins in Festkörpern von größter Bedeutung. Die Standardmethoden der Spindetektion, wie ESR, erlauben jedoch nur die Detektion von Spinensembles. Die Idee, die das Auslesen von einzelnen Spins ermöglich sollte, besteht darin, die Manipulation getrennt von der Detektion auszuführen.rn Bei dem NV−-Zentrum handelt es sich um eine spezielle Gitterfehlstelle im Diamant, die sich als einen atomaren, optisch auslesbaren Magnetfeldsensor benutzen lässt. Durch die Messung seiner Fluoreszenz sollte es möglich sein die Manipulation anderer, optisch nicht detektierbaren, “Dunkelspins“ in unmittelbarer Nähe des NV-Zentrums mittels der Spin-Spin-Kopplung zu detektieren. Das vorgeschlagene Modell des Quantencomputers basiert auf dem in SWCNT eingeschlossenen N@C60.Die Peapods, wie die Einheiten aus den in Kohlenstoffnanoröhre gepackten Fullerenen mit eingefangenem Stickstoff genannt werden, sollen die Grundlage für die Recheneinheiten eines wahren skalierbaren Quantencomputers bilden. Die in ihnen mit dem Stickstoff-Elektronenspin durchgeführten Rechnungen sollen mit den oberflächennahen NV-Zentren (von Diamantplatten), über denen sie positioniert sein sollen, optisch ausgelesen werden.rnrnDie vorliegende Arbeit hatte das primäre Ziel, die Kopplung der oberflächennahen NV-Einzelzentren an die optisch nicht detektierbaren Spins der Radikal-Moleküle auf der Diamantoberfläche mittels der ODMR-Kopplungsexperimente optisch zu detektieren und damit entscheidende Schritte auf dem Wege der Realisierung eines Quantenregisters zu tun.rn Es wurde ein sich im Entwicklungsstadium befindende ODMR-Setup wieder aufgebaut und seine bisherige Funktionsweise wurde an kommerziellen NV-Zentrum-reichen Nanodiamanten verifiziert. Im nächsten Schritt wurde die Effektivität und Weise der Messung an die Detektion und Manipulation der oberflächennah (< 7 nm Tiefe) implantieren NV-Einzelzenten in Diamantplatten angepasst.Ein sehr großer Teil der Arbeit, der hier nur bedingt beschrieben werden kann, bestand aus derrnAnpassung der existierenden Steuersoftware an die Problematik der praktischen Messung. Anschließend wurde die korrekte Funktion aller implementierten Pulssequenzen und anderer Software-Verbesserungen durch die Messung an oberflächennah implantierten NV-Einzelzentren verifiziert. Auch wurde der Messplatz um die zur Messung der Doppelresonanz notwendigen Komponenten wie einen steuerbaren Elektromagneten und RF-Signalquelle erweitert. Unter der Berücksichtigung der thermischen Stabilität von N@C60 wurde für zukünftige Experimente auch ein optischer Kryostat geplant, gebaut, in das Setup integriert und charakterisiert.rn Die Spin-Spin-Kopplungsexperimente wurden mit dem sauerstoffstabilen Galvinoxyl-Radikalals einem Modell-System für Kopplung durchgeführt. Dabei wurde über die Kopplung mit einem NVZentrum das RF-Spektrum des gekoppelten Radikal-Spins beobachtet. Auch konnte von dem gekoppelten Spin eine Rabi-Nutation aufgenommen werden.rn Es wurden auch weitere Aspekte der Peapod Messung und Oberflächenimplantation betrachtet.Es wurde untersucht, ob sich die NV-Detektion durch die SWCNTs, Peapods oder Fullerene stören lässt. Es zeigte sich, dass die Komponenten des geplanten Quantencomputers, bis auf die C60-Cluster, für eine ODMR-Messanordnung nicht detektierbar sind und die NV-Messung nicht stören werden. Es wurde auch betrachtet, welche Arten von kommerziellen Diamantplatten für die Oberflächenimplantation geeignet sind, für die Kopplungsmessungen geeignete Dichte der implantierten NV-Zentren abgeschätzt und eine Implantation mit abgeschätzter Dichte betrachtet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, a method for the functionalization of biocompatible, poly(lactic acid)-based nanoparticles with charged moieties or fluorescent labels is presented. Therefore, a miniemulsion solvent evaporation procedure is used in which prepolymerized poly(L-lactic acid) is used together with a previously synthesized copolymer of methacrylic acid or a polymerizable dye, respectively, and an oligo(lactic acid) macromonomer. Alternatively, the copolymerization has been carried out in one step with the miniemulsion solvent evaporation. The increased stability in salty solutions of the carboxyl-modified nanoparticles compared to nanoparticles consisting of poly(lactic acid) only has been shown in light scattering experiments. The properties of the nanoparticles that were prepared with the separately synthesized copolymer were almost identical to those in which the copolymerization and particle fabrication were carried out simultaneously. During the characterization of the fluorescently labeled nanoparticles, the focus was on the stable bonding between the fluorescent dye and the rest of the polymer chain to ensure that none of it is released from the particles, even after longer storage time or during lengthy experiments. In a fluorescence correlation spectroscopy experiment, it could be shown that even after two weeks, no dye has been released into the solvent. Besides biomedical research for which the above described, functionalized nanoparticles were optimized, nanoparticles also play a role in coating technology. One possibility to fabricate coatings is the electrophoretic deposition of particles. In this process, the mobility of nanoparticles near electrode interfaces plays a crucial role. In this thesis, the nanoparticle mobility has been investigated with resonance enhanced dynamic light scattering (REDLS). A new setup has been developed in which the evanescent electromagnetic eld of a surface plasmon that propagates along the gold-sample interface has been used as incident beam for the dynamic light scattering experiment. The gold layer that is necessary for the excitation of the plasmon doubles as an electrode. Due to the penetration depth of the surface plasmon into the sample layer that is limited to ca. 200 nm, insights on the voltage- and frequency dependent mobility of the nanoparticles near the electrode could be gained. Additionally, simultaneous measurements at four different scattering angles can be carried out with this setup, therefore the investigation of samples undergoing changes is feasible. The results were discussed in context with the mechanisms of electrophoretic deposition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Quantisierung der elektrischen Ladung ist eine der größten Fragestellungen der Physik, die bis heute nicht verstanden ist. Im Standardmodell der Teilchenphysik ist sie beispielsweise nicht mathematisch inhärent erklärbar. Dadurch wäre es möglich, dass das Neutron eine winzige Ladung tragen kann. In dieser Arbeit wurde eine Apparatur auf Grundlage eines Vorgängerexperiments entwickelt, mit der eine Untersuchung der Ladung des Neutrons mit höchster Präzision durchgeführt werden kann. Dabei werden ultrakalte Neutronen in einem optischen System einem elektrischen Feld zwischen zwei Elektrodenplatten ausgesetzt. In der ersten Ladungsmessung mit dieser Apparatur konnte eine statistische Sensitivität von δq≈2,4∙10⁻²⁰ e/√d erreicht werden. Diese Sensitivität ist die höchste, die bisher mit ultrakalten Neutronen für eine Ladungsmessung erreicht werden konnte. In dieser Arbeit wurde das Konzept des Vorgängerexperiments grundlegend überarbeitet, um die Sensitivität der Apparatur zu erhöhen. Es wurden detaillierte Untersuchungen der Systematik der Apparatur durchgeführt und das theoretische Potential der Sensitivität von derzeit δq≈10⁻²¹ e/√d ermittelt. Mit dieser Apparatur wurde der Grundstein für die Messung einer neuen niedrigeren oberen Grenze der elektrischen Ladung des Neutrons gelegt. In nächster Zeit kann dadurch eine niedrigere obere Grenze für die Ladung des Neutrons von q≈10⁻²² e erzielt werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This dissertation consists of three self-contained papers that are related to two main topics. In particular, the first and third studies focus on labor market modeling, whereas the second essay presents a dynamic international trade setup.rnrnIn Chapter "Expenses on Labor Market Reforms during Transitional Dynamics", we investigate the arising costs of a potential labor market reform from a government point of view. To analyze various effects of unemployment benefits system changes, this chapter develops a dynamic model with heterogeneous employed and unemployed workers.rn rnIn Chapter "Endogenous Markup Distributions", we study how markup distributions adjust when a closed economy opens up. In order to perform this analysis, we first present a closed-economy general-equilibrium industry dynamics model, where firms enter and exit markets, and then extend our analysis to the open-economy case.rn rnIn Chapter "Unemployment in the OECD - Pure Chance or Institutions?", we examine effects of aggregate shocks on the distribution of the unemployment rates in OECD member countries.rn rnIn all three chapters we model systems that behave randomly and operate on stochastic processes. We therefore exploit stochastic calculus that establishes clear methodological links between the chapters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The excitation spectrum is one of the fundamental properties of every spatially extended system. The excitations of the building blocks of normal matter, i.e., protons and neutrons (nucleons), play an important role in our understanding of the low energy regime of the strong interaction. Due to the large coupling, perturbative solutions of quantum chromodynamics (QCD) are not appropriate to calculate long-range phenomena of hadrons. For many years, constituent quark models were used to understand the excitation spectra. Recently, calculations in lattice QCD make first connections between excited nucleons and the fundamental field quanta (quarks and gluons). Due to their short lifetime and large decay width, excited nucleons appear as resonances in scattering processes like pion nucleon scattering or meson photoproduction. In order to disentangle individual resonances with definite spin and parity in experimental data, partial wave analyses are necessary. Unique solutions in these analyses can only be expected if sufficient empirical information about spin degrees of freedom is available. The measurement of spin observables in pion photoproduction is the focus of this thesis. The polarized electron beam of the Mainz Microtron (MAMI) was used to produce high-intensity, polarized photon beams with tagged energies up to 1.47 GeV. A "frozen-spin" Butanol target in combination with an almost 4π detector setup consisting of the Crystal Ball and the TAPS calorimeters allowed the precise determination of the helicity dependence of the γp → π0p reaction. In this thesis, as an improvement of the target setup, an internal polarizing solenoid has been constructed and tested. A magnetic field of 2.32 T and homogeneity of 1.22×10−3 in the target volume have been achieved. The helicity asymmetry E, i.e., the difference of events with total helicity 1/2 and 3/2 divided by the sum, was determined from data taken in the years 2013-14. The subtraction of background events arising from nucleons bound in Carbon and Oxygen was an important part of the analysis. The results for the asymmetry E are compared to existing data and predictions from various models. The results show a reasonable agreement to the models in the energy region of the ∆(1232)-resonance but large discrepancies are observed for energy above 600 MeV. The expansion of the present data in terms of Legendre polynomials, shows the sensitivity of the data to partial wave amplitudes up to F-waves. Additionally, a first, preliminary multipole analysis of the present data together with other results from the Crystal Ball experiment has been as been performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seit seiner Entdeckung im Jahre 1978 wurden für hyperpolarisiertes (HP) 129Xe zahlreiche Anwendungen gefunden. Aufgrund seiner hohen Verstärkung von NMR-Signalen wird es dabei typischerweise für Tracer- und Oberflächenstudien verwendet. Im gasförmigen Zustand ist es ein interessantes, klinisches Kontrastmittel, welches für dynamische Lungen MRT genutzt oder auch in Blut oder lipophilen Flüssigkeiten gelöst werden kann. Weiterhin findet HP-Xe auch in der Grundlagenphysik in He-Xe Co-Magnetometern Verwendung, mit welchen z. B. das elektrische Dipolmoment von Xe bestimmt werden soll, oder es dient zur Überprüfung auf Lorentz-Invarianzen. Alle diese Anwendungen profitieren von einem hohen Polarisationsgrad (PXe), um hohe Signalstärken und lange Lagerzeiten zu erreichen. rnIn dieser Arbeit wurden zwei mobile Xe-Polarisatoren konstruiert: einer für Experimente in der Grundlagenphysik mit einer Produktionsrate von 400 mbar·l/h mit PXe ≈ 5%. Der zweite Xe-Polarisator wurde für medizinische Anwendungen entwickelt und soll 1 bar l/h mit PXe > 20% erzeugen. Der letztere wurde noch nicht getestet. Die Arbeitsbedingungen des Xe-Polarisators für Grundlagenphysik (Strömung des Gasgemischs, Temperatur, Druck und Konzentration von Xe) wurden variiert, um einen höchstmöglichen Polarisationsgrad zu erzielen. Die maximale Polarisation von 5,6 % wurde bei Verwendung eine Gasmischung von 1% Xe bei einem Durchfluss von 200 ml/min, einer Temperatur von 150°C und einem Gesamtdruck von 4 bar erreicht. rnWeiterhin muss HP-Xe auch effizient gelagert werden, um Polarisationsverluste zu minimieren. Das ist besonders für solche Anwendungen notwendig, welche an einem entfernten Standort durchgeführt werden sollen oder auch wenn lange Spinkohärenzeiten gefordert sind, z.B. bei He-Xe Co-Magnetometern. rnHierbei bestand bisher die größte Schwierigkeit darin, die Reproduzierbarkeit der gemessenen Lagerzeiten sicherzustellen. In dieser Arbeit konnte die Spin-Gitter-Relaxationszeit (T1) von HP-129Xe in unbeschichteten, Rb-freien, sphärischen Zellen aus Aluminiumsilikatglas (GE-180) signifikant verbessert werden. Die T1–Zeit wurde in einem selbstgebauten Niederfeld-NMR-System (2 mT) sowohl für reines HP-Xe als auch für HP-Xe in Mischungen mit N2, SF6 und CO2 bestimmt. Bei diesen Experimenten wurde die maximale Relaxationszeit für reines Xe (85% 129 Xe) bei (4,6 ± 0,1) h festgestellt. Dabei lagen die typischen Wand-Relaxationszeiten bei ca. 18 h für Glaszellen mit einem Durchmesser von 10 cm. Des Weiteren wurde herausgefunden, dass CO2 eine unerwartet hohe Effizienz bei der Verkürzung der Lebensdauer der Xe-Xe Moleküle zeigte und somit zu einer deutlichen Verlängerung der gesamten T1-Zeit genutzt werden kann. rnIm Verlauf vieler Experimente wurde durch wiederholte Messungen mit der gleichen Zelle, ein "Alterungsprozess“ bei der Wandrelaxation identifiziert und untersucht. Dieser Effekt könnte leicht rückgängig gemacht werden, indem die anfängliche Reinigungsprozedur wiederholt wurde. Auf diese Weise kann eine konstante Wandrelaxation sichergestellt werden, durch die sehr reproduzierbare T1-Messungen möglich werden. rnSchließlich wurde die maximale Relaxationszeit für HP-Xe mit natürlicher Häufigkeit in Mischungen mit SF6 bestimmt. Überraschenderweise war dieser Wert um ca. 75% niedriger als der Wert für Xenon, das zu 85% mit 129Xe angereichert war. Dieser Effekt wurde durch drei unabhängige Experimente bestätigt, da er nicht von der bestehenden Theorie der Xe-Relaxation ableitbar ist. rnDie Polarisation von HP-Xe, PXe, wird normalerweise durch den Vergleich der NMR-Signale des HP-Xe mit einer thermischen polarisierten Probe (z. B. 1H2O oder Xe) bestimmt. Dabei beinhaltet der Vergleich unterschiedlicher Messungen an verschiedenen Proben (unterschiedlicher Druck, Signalintensität und Messverfahren) viele experimentelle Unsicherheiten, welche sich oft nicht leicht bestimmen lassen. Eine einfache, genaue und kostengünstige Methode zur Bestimmung von PXe durch eine direkte Messung der makroskopischen Magnetisierung in einem statischen Magnetfeld vermeidet alle diese Unsicherheiten. Dieses Verfahren kann Polarisationen von > 2 % mit einer Genauigkeit von maximal 10% fast ohne Polarisationsverlust bestimmen. Zusätzlich kann diese Methode ohne weitere Änderungen auch für Bestimmungen des Polarisationsgrades anderer HP-Gase verwendet werden.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In questo lavoro saranno inizialmente discusse le tecniche medianti le quali sono cresciuti i monocristalli organici confrontando le tecniche di crescita proprie dell’elettronica organica con quelle utilizzate comunemente in quella inorganica. Successivamente si introdurrà il problema del trasporto elettronico con particolare riguardo verso alcune molecole come il rubrene o il pentacene. Tramite il modello microscopico verranno studiate le interazioni elettrone-fonone, locale e non locale, in particolare nei cristalli di rubrene e DMQtT–F4TCNQ attraverso la teoria del piccolo polarone di Holstein. Dopo aver sottolineato i limiti di questa teoria ne verrà proposta una alternativa basata sui lavori di Troisi e supportata da evidenze sperimentali. Tra le tecniche utilizzate per l’analisi dei campioni verranno discusse le basi della teoria del funzionale di densità. L’attenzione sarà rivolta ai cristalli ordinati mentre una breve descrizione sarà riservata per quelli disordinati o amorfi. Nel capitolo 3 verrà trattato il ruolo degli eccitoni all’interno dei semiconduttori organici, mentre nell’ultimo capitolo si discuterà di diverse applicazioni dei semiconduttori organici come la costruzione di FET e di detector per raggi X. Infine verranno mostrati il setup sperimentale e il procedimento per l’estrazione di parametri di bulk in un semiconduttore organico tramite analisi SCLC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nell’ambito del nuoto, la scelta della strumentazione è legata all’ambiente, il metodo più utilizzato per analizzare il movimento degli atleti, ancora oggi, è quello dell’analisi video, che utilizza videocamere subacquee. L’analisi video in acqua ha diversi limiti: presenta errori legati alla turbolenza e alla rifrazione aria/acqua, necessità di elevati tempi sia per la calibrazione sia per l’elaborazione dei dati, non consente un feedback in tempo reale e quindi non fornisce informazioni immediate all’allenatore e ha costi elevati. Da qui la necessità di investigare altri metodi. Il metodo alternativo proposto, per la prima volta da Oghi et al. nel 2000 utilizza i sensori inerziali (IMU- Inertial Measurements Units) che possono essere indossati dall’atleta, previa impermeabilizzazione. Non sono invasivi e non limitano eccessivamente il movimento, non richiedono un setup di calibrazione complesso e hanno costi ridotti. Per questo elaborato sono stati stimati i parametri che vengono tipicamente utilizzati dagli allenatori per valutare le performance degli atleti durante l’allenamento: parametri temporali legati alle fasi della bracciata e la velocità istantanea. Sono state effettuate prove sul campo, presso il Laboratorio di Biomeccanica della Scuola di Farmacia, Biotecnologie e Scienze Motorie, situato nella palestra Record del CUSB di Bologna.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Un ambito di largo interesse nel campo dell’elettronica, è quello delle misure di corrente a larga banda, in cui la richiesta per sistemi a basso costo è aumentata sensibilmente nel corso del tempo. La causa di questo interessamento è dovuto al più frequente utilizzo di sistemi switched power ad alta frequenza, che necessitano di sensori di correnti isolati e ad alte prestazioni. L’intero lavoro prende in considerazione un sensore di nuova generazione per le misure di corrente, capace di raggiungere prestazioni oltre lo stato dell’arte. L’elaborato presentato vede, quindi, come obiettivo la creazione di un setup stabile per effettuare misure sui chip prodotti. Partendo dallo studio di fattibilità, della componentistica necessaria e dei compromessi per mantenere i costi, si giunge ad una soluzione flessibile e adatta alle misurazioni richieste. L’elaborato partirà con una introduzione sugli effetti fisici e la descrizione del componente fondamentale, passando a test funzionali effettuati su setup provvisori atti a ottenere informazioni basilari per la prosecuzione del lavoro. Infine verranno concepite e realizzate due schede a circuiti stampati per rispondere alle esigenze di progetto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Il plasma è denominato quarto stato della materia ed è generalmente definito come un gas ionizzato costituito da elettroni e ioni. In ambito industriale i plasmi hanno trovato impiego per diversi tipi di applicazione quali il trattamento di superfici, la degradazione e lo smaltimento di rifiuti, il taglio di materiali, primi fra tutti i metalli. In particolare i plasmi atmosferici di non equilibrio, che possiedono la caratteristica di mantenere una temperatura macroscopica paragonabile a quella ambiente, sono studiati anche per applicazioni in campo biomedicale, oltre che in quello industriale. Da alcuni anni sono quindi oggetto di indagine per le caratteristiche di sterilizzazione di fluidi o solidi, per la coagulazione e il trattamento di lesioni e lacerazioni, per trattamenti su superfici quali la pelle, per il trattamento di cellule tumorali e staminali o per interfacce dispositivi biomedicali – corpo umano. Questo nuovo settore di ricerca, in grande sviluppo, viene comunemente definito Plasma & Medicine. Poiché in ambito biomedicale, un trattamento plasma può interessare diverse tipologie di substrati biologici e materiali, è stato scelto come obiettivo della tesi la caratterizzazione di una sorgente di plasma di non equilibrio a pressione atmosferica, denominata Plasma Jet, posta ad interagire con substrati di diversa natura (metallico, dielettrico, liquido). La sorgente utilizzata è in grado di produrre un plasma freddo e biocompatibile, generando diverse specie chimiche che garantiscono effetti molto interessanti (sterilizzazione, accelerazione della coagulazione sanguigna, cura di infezioni) per un utilizzo a contatto con il corpo umano o con componenti ingegneristiche che devono venire ad interagire con esso, quali stent, cateteri, bisturi. La caratterizzazione è stata effettuata mediante l’ausilio di due tecniche diagnostiche: la Schlieren Imaging, che permette di studiare la fluidodinamica del gas, OES (Optical Emission Spettroscopy), che permette di analizzare la composizione chimica della piuma di plasma e di determinare le specie chimiche che si producono. Questo elaborato si propone quindi di fornire una breve introduzione sul mondo dei plasmi e sulle loro caratteristiche, citando alcuni dei settori in cui viene utilizzato, industriali e biomedicali, con particolare attenzione per questi ultimi. Successivamente saranno riportati i setup utilizzati per le acquisizioni e una discussione sui risultati ottenuti dalle diverse tecniche diagnostiche utilizzate sul Jet durante i trattamenti. In ultimo sono poi riportate le conclusioni in modo da presentare le caratteristiche più importanti del comportamento della sorgente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present thesis work proposes a new physical equivalent circuit model for a recently proposed semiconductor transistor, a 2-drain MSET (Multiple State Electrostatically Formed Nanowire Transistor). It presents a new software-based experimental setup that has been developed for carrying out numerical simulations on the device and on equivalent circuits. As of 2015, we have already approached the scaling limits of the ubiquitous CMOS technology that has been in the forefront of mainstream technological advancement, so many researchers are exploring different ideas in the realm of electrical devices for logical applications, among them MSET transistors. The idea that underlies MSETs is that a single multiple-terminal device could replace many traditional transistors. In particular a 2-drain MSET is akin to a silicon multiplexer, consisting in a Junction FET with independent gates, but with a split drain, so that a voltage-controlled conductive path can connect either of the drains to the source. The first chapter of this work presents the theory of classical JFETs and its common equivalent circuit models. The physical model and its derivation are presented, the current state of equivalent circuits for the JFET is discussed. A physical model of a JFET with two independent gates has been developed, deriving it from previous results, and is presented at the end of the chapter. A review of the characteristics of MSET device is shown in chapter 2. In this chapter, the proposed physical model and its formulation are presented. A listing for the SPICE model was attached as an appendix at the end of this document. Chapter 3 concerns the results of the numerical simulations on the device. At first the research for a suitable geometry is discussed and then comparisons between results from finite-elements simulations and equivalent circuit runs are made. Where points of challenging divergence were found between the two numerical results, the relevant physical processes are discussed. In the fourth chapter the experimental setup is discussed. The GUI-based environments that allow to explore the four-dimensional solution space and to analyze the physical variables inside the device are described. It is shown how this software project has been structured to overcome technical challenges in structuring multiple simulations in sequence, and to provide for a flexible platform for future research in the field.