983 resultados para Sampling strategies


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prediction of the impact of suspended sediment on aquatic ecosystems requires adequate knowledge of sediment dynamics in surface waters. Often, studies reporting the response of aquatic biota to suspended sediment are concerned with concentrations, while catchment erosion studies often report sediment delivery as annual loads and yields, making the comparison to documented ecological impacts difficult. Similarly, the European Union Freshwater Fish Directive (FFD) (78/659/EC) stipulates a guideline value of 25mgl which should not be exceeded, with the exception of floods and droughts. In this respect, the significance of suspended sediment in two Irish rivers was assessed using turbidity sensors calibrated for suspended sediment. Sediment yields of 0.07 tonnes (t) hayear and 0.44thayear and annual FFD exceedance frequency of 8.3% and 17.8% were estimated for the two catchments. Contrasts in the frequency of exceedance events between both catchments was observed, yet duration was typically short (

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sediment particle size analysis (PSA) is routinely used to support benthic macrofaunal community distribution data in habitat mapping and Ecological Status (ES) assessment. No optimal PSA Method to explain variability in multivariate macrofaunal distribution has been identified nor have the effects of changing sampling strategy been examined. Here, we use benthic macrofaunal and PSA grabs from two embayments in the south of Ireland. Four frequently used PSA Methods and two common sampling strategies are applied. A combination of laser particle sizing and wet/dry sieving without peroxide pre-treatment to remove organics was identified as the optimal Method for explaining macrofaunal distributions. ES classifications and EUNIS sediment classification were robust to changes in PSA Method. Fauna and PSA samples returned from the same grab sample significantly decreased macrofaunal variance explained by PSA and caused ES to be classified as lower. Employing the optimal PSA Method and sampling strategy will improve benthic monitoring. © 2012 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Detailed surveys of depth and velocity are undertaken to describe hydro-ecological status of rivers. Fieldwork for these surveys is time consuming and expensive. This paper aims to describe the methodology applied in order to determine the most suitable depth sampling strategy for effective field data collection and river representation in time and space at the Leigh Brook river site, Worcester, UK. The accuracy of three different sampling strategies for predicting depth at non-measured points has been compared and the mesohabitats that better characterise depth changes due to variations in discharge have been identified. The results show that depth changes due to discharge change are mainly located at shallow and deep glide mesohabitat types. The analysis for the comparison of sampling strategies indicates that grid sampling strategies give better results than regular transects. Since the results also show that higher errors in predictions are obtained in the deepest areas, higher sampling densities should be applied in these locations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le suivi thérapeutique est recommandé pour l’ajustement de la dose des agents immunosuppresseurs. La pertinence de l’utilisation de la surface sous la courbe (SSC) comme biomarqueur dans l’exercice du suivi thérapeutique de la cyclosporine (CsA) dans la transplantation des cellules souches hématopoïétiques est soutenue par un nombre croissant d’études. Cependant, pour des raisons intrinsèques à la méthode de calcul de la SSC, son utilisation en milieu clinique n’est pas pratique. Les stratégies d’échantillonnage limitées, basées sur des approches de régression (R-LSS) ou des approches Bayésiennes (B-LSS), représentent des alternatives pratiques pour une estimation satisfaisante de la SSC. Cependant, pour une application efficace de ces méthodologies, leur conception doit accommoder la réalité clinique, notamment en requérant un nombre minimal de concentrations échelonnées sur une courte durée d’échantillonnage. De plus, une attention particulière devrait être accordée à assurer leur développement et validation adéquates. Il est aussi important de mentionner que l’irrégularité dans le temps de la collecte des échantillons sanguins peut avoir un impact non-négligeable sur la performance prédictive des R-LSS. Or, à ce jour, cet impact n’a fait l’objet d’aucune étude. Cette thèse de doctorat se penche sur ces problématiques afin de permettre une estimation précise et pratique de la SSC. Ces études ont été effectuées dans le cadre de l’utilisation de la CsA chez des patients pédiatriques ayant subi une greffe de cellules souches hématopoïétiques. D’abord, des approches de régression multiple ainsi que d’analyse pharmacocinétique de population (Pop-PK) ont été utilisées de façon constructive afin de développer et de valider adéquatement des LSS. Ensuite, plusieurs modèles Pop-PK ont été évalués, tout en gardant à l’esprit leur utilisation prévue dans le contexte de l’estimation de la SSC. Aussi, la performance des B-LSS ciblant différentes versions de SSC a également été étudiée. Enfin, l’impact des écarts entre les temps d’échantillonnage sanguins réels et les temps nominaux planifiés, sur la performance de prédiction des R-LSS a été quantifié en utilisant une approche de simulation qui considère des scénarios diversifiés et réalistes représentant des erreurs potentielles dans la cédule des échantillons sanguins. Ainsi, cette étude a d’abord conduit au développement de R-LSS et B-LSS ayant une performance clinique satisfaisante, et qui sont pratiques puisqu’elles impliquent 4 points d’échantillonnage ou moins obtenus dans les 4 heures post-dose. Une fois l’analyse Pop-PK effectuée, un modèle structural à deux compartiments avec un temps de délai a été retenu. Cependant, le modèle final - notamment avec covariables - n’a pas amélioré la performance des B-LSS comparativement aux modèles structuraux (sans covariables). En outre, nous avons démontré que les B-LSS exhibent une meilleure performance pour la SSC dérivée des concentrations simulées qui excluent les erreurs résiduelles, que nous avons nommée « underlying AUC », comparée à la SSC observée qui est directement calculée à partir des concentrations mesurées. Enfin, nos résultats ont prouvé que l’irrégularité des temps de la collecte des échantillons sanguins a un impact important sur la performance prédictive des R-LSS; cet impact est en fonction du nombre des échantillons requis, mais encore davantage en fonction de la durée du processus d’échantillonnage impliqué. Nous avons aussi mis en évidence que les erreurs d’échantillonnage commises aux moments où la concentration change rapidement sont celles qui affectent le plus le pouvoir prédictif des R-LSS. Plus intéressant, nous avons mis en exergue que même si différentes R-LSS peuvent avoir des performances similaires lorsque basées sur des temps nominaux, leurs tolérances aux erreurs des temps d’échantillonnage peuvent largement différer. En fait, une considération adéquate de l'impact de ces erreurs peut conduire à une sélection et une utilisation plus fiables des R-LSS. Par une investigation approfondie de différents aspects sous-jacents aux stratégies d’échantillonnages limités, cette thèse a pu fournir des améliorations méthodologiques notables, et proposer de nouvelles voies pour assurer leur utilisation de façon fiable et informée, tout en favorisant leur adéquation à la pratique clinique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phylogenetic methods hold great promise for the reconstruction of the transition from precursor to modern flora and the identification of underlying factors which drive the process. The phylogenetic methods presently used to address the question of the origin of the Cape flora of South Africa are considered here. The sampling requirements of each of these methods, which include dating of diversifications using calibrated molecular trees, sister pair comparisons, lineage through time plots and biogeographical optimizations are reviewed. Sampling of genes, genomes and species are considered. Although increased higher-level studies and increased sampling are required for robust interpretation, it is clear that much progress is already made. It is argued that despite the remarkable richness of the flora, the Cape flora is a valuable model system to demonstrate the utility of phylogenetic methods in determining the history of a modern flora.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The EU Water Framework Directive (WFD) requires that the ecological and chemical status of water bodies in Europe should be assessed, and action taken where possible to ensure that at least "good" quality is attained in each case by 2015. This paper is concerned with the accuracy and precision with which chemical status in rivers can be measured given certain sampling strategies, and how this can be improved. High-frequency (hourly) chemical data from four rivers in southern England were subsampled to simulate different sampling strategies for four parameters used for WFD classification: dissolved phosphorus, dissolved oxygen, pH and water temperature. These data sub-sets were then used to calculate the WFD classification for each site. Monthly sampling was less precise than weekly sampling, but the effect on WFD classification depended on the closeness of the range of concentrations to the class boundaries. In some cases, monthly sampling for a year could result in the same water body being assigned to three or four of the WFD classes with 95% confidence, due to random sampling effects, whereas with weekly sampling this was one or two classes for the same cases. In the most extreme case, the same water body could have been assigned to any of the five WFD quality classes. Weekly sampling considerably reduces the uncertainties compared to monthly sampling. The width of the weekly sampled confidence intervals was about 33% that of the monthly for P species and pH, about 50% for dissolved oxygen, and about 67% for water temperature. For water temperature, which is assessed as the 98th percentile in the UK, monthly sampling biases the mean downwards by about 1 °C compared to the true value, due to problems of assessing high percentiles with limited data. Low-frequency measurements will generally be unsuitable for assessing standards expressed as high percentiles. Confining sampling to the working week compared to all 7 days made little difference, but a modest improvement in precision could be obtained by sampling at the same time of day within a 3 h time window, and this is recommended. For parameters with a strong diel variation, such as dissolved oxygen, the value obtained, and thus possibly the WFD classification, can depend markedly on when in the cycle the sample was taken. Specifying this in the sampling regime would be a straightforward way to improve precision, but there needs to be agreement about how best to characterise risk in different types of river. These results suggest that in some cases it will be difficult to assign accurate WFD chemical classes or to detect likely trends using current sampling regimes, even for these largely groundwater-fed rivers. A more critical approach to sampling is needed to ensure that management actions are appropriate and supported by data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We discuss the development and performance of a low-power sensor node (hardware, software and algorithms) that autonomously controls the sampling interval of a suite of sensors based on local state estimates and future predictions of water flow. The problem is motivated by the need to accurately reconstruct abrupt state changes in urban watersheds and stormwater systems. Presently, the detection of these events is limited by the temporal resolution of sensor data. It is often infeasible, however, to increase measurement frequency due to energy and sampling constraints. This is particularly true for real-time water quality measurements, where sampling frequency is limited by reagent availability, sensor power consumption, and, in the case of automated samplers, the number of available sample containers. These constraints pose a significant barrier to the ubiquitous and cost effective instrumentation of large hydraulic and hydrologic systems. Each of our sensor nodes is equipped with a low-power microcontroller and a wireless module to take advantage of urban cellular coverage. The node persistently updates a local, embedded model of flow conditions while IP-connectivity permits each node to continually query public weather servers for hourly precipitation forecasts. The sampling frequency is then adjusted to increase the likelihood of capturing abrupt changes in a sensor signal, such as the rise in the hydrograph – an event that is often difficult to capture through traditional sampling techniques. Our architecture forms an embedded processing chain, leveraging local computational resources to assess uncertainty by analyzing data as it is collected. A network is presently being deployed in an urban watershed in Michigan and initial results indicate that the system accurately reconstructs signals of interest while significantly reducing energy consumption and the use of sampling resources. We also expand our analysis by discussing the role of this approach for the efficient real-time measurement of stormwater systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The impact of initial sample distribution on separation and focusing of analytes in a pH 3–11 gradient formed by 101 biprotic carrier ampholytes under concomitant electroosmotic displacement was studied by dynamic high-resolution computer simulation. Data obtained with application of the analytes mixed with the carrier ampholytes (as is customarily done), as a short zone within the initial carrier ampholyte zone, sandwiched between zones of carrier ampholytes, or introduced before or after the initial carrier ampholyte zone were compared. With sampling as a short zone within or adjacent to the carrier ampholytes, separation and focusing of analytes is shown to proceed as a cationic, anionic, or mixed process and separation of the analytes is predicted to be much faster than the separation of the carrier components. Thus, after the initial separation, analytes continue to separate and eventually reach their focusing locations. This is different to the double-peak approach to equilibrium that takes place when analytes and carrier ampholytes are applied as a homogenous mixture. Simulation data reveal that sample application between two zones of carrier ampholytes results in the formation of a pH gradient disturbance as the concentration of the carrier ampholytes within the fluid element initially occupied by the sample will be lower compared to the other parts of the gradient. As a consequence thereof, the properties of this region are sample matrix dependent, the pH gradient is flatter, and the region is likely to represent a conductance gap (hot spot). Simulation data suggest that sample placed at the anodic side or at the anodic end of the initial carrier ampholyte zone are the favorable configurations for capillary isoelectric focusing with electroosmotic zone mobilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundación Ciudad de la Energía (CIUDEN) is carrying out a project of geological storage of CO2, where CO2 injection tests are planned in saline aquifers at a depth of 1500 m for scientific objectives and project demonstration. Before any CO2 is stored, it is necessary to determine the baseline flux of CO2 in order to detect potential leakage during injection and post-injection monitoring. In November 2009 diffuse flux measurements of CO2 using an accumulationchamber were made in the area selected by CIUDEN for geological storage, located in Hontomin province of Burgos (Spain). This paper presents the tests carried out in order to establish the optimum sampling methodology and the geostatistical analyses performed to determine the range, with which future field campaigns will be planned.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundación Ciudad de la Energía (CIUDEN) is carrying out a project of geological storage of CO2, where CO2 injection tests are planned in saline aquifers at a depth of 1500 m for scientific objectives and project demonstration. Before any CO2 is stored, it is necessary to determine the baseline flux of CO2 in order to detect potential leakage during injection and post-injection monitoring. In November 2009 diffuse flux measurements of CO2 using an accumulation chamber were made in the area selected by CIUDEN for geological storage, located in Hontomin province of Burgos (Spain). This paper presents the tests carried out in order to establish the optimum sampling methodology and the geostatistical analyses performed to determine the range, with which future field campaigns will be planned.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.