979 resultados para Saliva Diagnostics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part A

A problem restricting the development of the CuCl laser has been the decrease in output power with increases of tube temperature above 400°C. At that temperature the CuCl vapor pressure is about .1 torr. This is a small fraction of the buffer gas pressure (He at 10 torr).

The aim of the project was to measure the peak radiation temperature (assumed related to the mean energy of electrons) in the laser discharge as a function of the tube temperature. A 24 gHz gated microwave radiometer was used.

It was found that at the tube temperatures at which the output power began to deteriorate, the electron radiation temperature showed a sharp increase (compared with radiation temperature in pure buffer).

Using the above result, we have postulated that this sudden increase is a result of Penning ionization of the Cu atoms. As a consequence of this process the number of Cu atoms available for lasing decrease.

PART B

The aim of the project was to study the dissociation of CO2 in the glow discharge of flowing CO2 lasers.

A TM011 microwave (3 gHz) cavity was used to measure the radially averaged electron density ne and the electron-neutral collision frequency in the laser discharge. An estimate of the electric field is made from these two measurements. A gas chromatograph was used to measure the chemical composition of the gases after going through the discharge. This instrument was checked against a mass spectrometer for accuracy and sensitivity.

Several typical laser mixtures were .used: CO2-N2-He (1,3,16), (1,3,0), (1,0,16), (1,2,10), (1,2,0), (1,0,10), (2,3,15), (2,3,0), (2,0,15), (1,3,16)+ H2O and pure CO2. Results show that for the conditions studied the dissociation as a function of the electron density is uniquely determined by the STP partial flow rate of CO2, regardless of the amount of N2 and/or He present. The presence of water vapor in the discharge decreased the degree of dissociation.

A simple theoretical model was developed using thermodynamic equilibrium. The electrons were replaced in the calculations by a distributed heat source.

The results are analyzed with a simple kinetic model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motivated by needs in molecular diagnostics and advances in microfabrication, researchers started to seek help from microfluidic technology, as it provides approaches to achieve high throughput, high sensitivity, and high resolution. One strategy applied in microfluidics to fulfill such requirements is to convert continuous analog signal into digitalized signal. One most commonly used example for this conversion is digital PCR, where by counting the number of reacted compartments (triggered by the presence of the target entity) out of the total number of compartments, one could use Poisson statistics to calculate the amount of input target.

However, there are still problems to be solved and assumptions to be validated before the technology is widely employed. In this dissertation, the digital quantification strategy has been examined from two angles: efficiency and robustness. The former is a critical factor for ensuring the accuracy of absolute quantification methods, and the latter is the premise for such technology to be practically implemented in diagnosis beyond the laboratory. The two angles are further framed into a “fate” and “rate” determination scheme, where the influence of different parameters is attributed to fate determination step or rate determination step. In this discussion, microfluidic platforms have been used to understand reaction mechanism at single molecule level. Although the discussion raises more challenges for digital assay development, it brings the problem to the attention of the scientific community for the first time.

This dissertation also contributes towards developing POC test in limited resource settings. On one hand, it adds ease of access to the tests by incorporating massively producible, low cost plastic material and by integrating new features that allow instant result acquisition and result feedback. On the other hand, it explores new isothermal chemistry and new strategies to address important global health concerns such as cyctatin C quantification, HIV/HCV detection and treatment monitoring as well as HCV genotyping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to feed on vertebrate blood has evolved many times in various arthropod clades. Consequently, saliva of blood-feeding arthropods has proven to be a rich source of antihemostatic molecules. A variety of platelet aggregation inhibitors antagonize platelet responses to wound-generated signals, including ADP, thrombin, and collagen. Anticoagulants disrupt elements of both the intrinsic and extrinsic pathways. Vasodilators include nitrophorins (nitric oxide storage and transport heme proteins), a variety of peptides that mimic endogenous vasodilatory neuropeptides, and proteins that catabolize or sequester endogenous vasoconstrictors. Multiple salivary proteins may be directed against each component of hemostasis, resulting in both redundancy and in some cases cooperative interactions between antihemostatic proteins. The complexity and redundancy of saliva ensures an efficient blood meal for the arthropod, but it also provides a diverse array of novel antihemostatic molecules for the pharmacologist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Ag5 proteins are the most abundant and immunogenic proteins in the venom secretory ducts of stinging insects. An antigen 5-like protein (named tabRTS) composed of 221 amino acid residues was purified and characterized from the salivary glands of the horsefly, Tabanus yao (Diptera, Tabanidae). Its cDNA was cloned from the cDNA library of the horsefly's salivary gland. TabRTS containing the SCP domain (Sc7 family of extracellular protein domain) was found in insect antigen 5 proteins. More interestingly, there is an Arg-Thr-Ser (RTS) disintegrin motif at the C-terminus of tabRTS. The RTS motif is positioned in a loop bracketed by cysteine residues as those found in RTS-disintegrins of Crotalidae and Viperidae snake venoms, which act as angiogenesis inhibitors. Endothelial Cell Tube formation assay in vitro and chicken chorioallantoic membrane (CAM) angiogenesis assay in vivo were performed as to investigate the effect of tabRTS on angiogenesis. It was found that tabRTS could significantly inhibit angiogenesis in vitro and in vivo. Anti-alpha(1)beta(1) monoclonal antibody could dose-dependently inhibit the anti-angiogenic activity of tabRTS. This result indicated that tabRTS possibly targets the alpha(1)beta(1) integrin to exert the anti-angiogenic activity as snake venom RTS-/KTS-disintegrins do. The current work revealed the first angiogenesis inhibitor protein containing RTS motif from invertebrates, a possible novel type of RTS-disintegrin. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combustion oscillations in gas turbines can result in serious damage. One method used to predict such oscillations is to analyze the combustor acoustics using a simple linear model. Such a model requires a flame transfer function to describe the response of the heat release to flow perturbations inside the combustor. This paper reports on the application of Planar Laser Induced Fluorescence (PLIF) of OH radicals to analyze the response of a lean premixed flame to oncoming flow perturbations. Both self-excited oscillations and low amplitude forced oscillations at various frequencies are investigated in an atmospheric pressure model combustor rig. In order to visualize fluctuations of local fuel distribution, acetone-PLIF was also applied in non-reacting and acoustically forced flows at oscillation frequencies of 200 Hz and 510 Hz, respectively. OH-PLIF images were acquired over a range of operating parameters. The results presented in this paper originate from data sets acquired at fixed phase angles during the oscillation cycle. Comparative experiments in self excited and forced acoustic oscillations show that the flame and the combustion intensity develop similarly throughout the pressure cycle in both cases. Although the peak fluorescence intensities differ between self excited and the forced instabilities, there is a clear correspondence in the observed frequency and phase information from the two cases. This result encourages a comparison of the OH-PLIF and the acetone-PLIF results. Quantitative measurements of the equivalence ratio in specific areas of the measurement plane offer insight on the complex phenomena coupling acoustic perturbations, i.e. flow velocity fluctuations, to fluctuations in fuel distribution and combustion intensity, ultimately resulting in self excited combustion oscillations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser beam diagnosis is usually carried out off-line in order to minimise the disruption to the process being carried out. This paper presents the results of a fractional sampling device for a high power beam diagnosis system capable of measuring in process beam properties such as beam diameter, intensity and beam position. The paper discusses the application of this sampling technique for monitoring beam properties during the laser materials processing operation.