1000 resultados para STRAIN


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The strain data acquired from structural health monitoring (SHM) systems play an important role in the state monitoring and damage identification of bridges. Due to the environmental complexity of civil structures, a better understanding of the actual strain data will help filling the gap between theoretical/laboratorial results and practical application. In the study, the multi-scale features of strain response are first revealed after abundant investigations on the actual data from two typical long-span bridges. Results show that, strain types at the three typical temporal scales of 10^5, 10^2 and 10^0 sec are caused by temperature change, trains and heavy trucks, and have their respective cut-off frequency in the order of 10^-2, 10^-1 and 10^0 Hz. Multi-resolution analysis and wavelet shrinkage are applied for separating and extracting these strain types. During the above process, two methods for determining thresholds are introduced. The excellent ability of wavelet transform on simultaneously time-frequency analysis leads to an effective information extraction. After extraction, the strain data will be compressed at an attractive ratio. This research may contribute to a further understanding of actual strain data of long-span bridges; also, the proposed extracting methodology is applicable on actual SHM systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We reported the thermal conductivity of the two-dimensional carbon nanotube (CNT)-based architecture, which can be constructed through welding of single-wall CNTs by electron beam. Using large-scale nonequilibrium molecular dynamics simulations, the thermal conductivity is found to vary with different junction types due to their different phonon scatterings at the junction. The strong length and strain dependence of the thermal conductivity suggests an effective avenue to tune the thermal transport properties of the CNT-based architecture, benefiting the design of nanoscale thermal rectifiers or phonon engineering.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This research evaluated the effect of tendinopathy on the cumulative transverse strain response of the patellar tendon to a bout of resistive quadriceps exercise. Methods Nine adults with unilateral patellar tendinopathy (age 18.2±0.7 years, height 1.92±0.06 m and weight 76.8±6.8 kg) and ten healthy adults free of knee pain (age 17.8±0.8 years, height 1.83±0.05 m and weight 73.2±7.6 kg) underwent standardised sagittal sonograms (7.2–14 MHz linear–array transducer) of both patellar tendons immediately prior and following 45 repetitions of a double–leg decline–squat exercise performed against a resistance of 145% bodyweight. Tendon thickness was determined 5–mm and 25–mm distal to the patellar pole. Transverse Hencky strain was calculated as the natural log of the ratio of post– to pre–exercise tendon thickness and expressed as a percentage. Measures of tendon echogenicity were calculated within the superficial and deep aspects of each tendon site from gray–scale profiles. Intratendinous microvessels were evaluated using power Doppler ultrasound. Results The cumulative transverse strain response to exercise in symptomatic tendinopathy was significantly lower than that of asymptomatic and healthy tendon (P<.05). There was also a significant reduction (57%) in the area of microvascularity immediately following exercise (P=.05), which was positively correlated (r=0.93, P<.05) with VISA-P score. Conclusions This study is the first to show that patellar tendinopathy is associated with an altered morphological and mechanical response of the tendon to exercise, which is manifest by a reduction in cumulative transverse strain and microvascularity, when present. Research directed toward identifying factors that influence the acute microvascular and transverse strain response of the patellar tendon to exercise in the various stages of tendinopathy is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The purpose of this paper is to test a multilevel model of the main and mediating effects of supervisor conflict management style (SCMS) climate and procedural justice (PJ) climate on employee strain. It is hypothesized that workgroup-level climate induced by SCMS can fall into four types: collaborative climate, yielding climate, forcing climate, or avoiding climate; that these group-level perceptions will have differential effects on employee strain, and will be mediated by PJ climate. Design/methodology/approach Multilevel SEM was used to analyze data from 420 employees nested in 61 workgroups. Findings Workgroups that perceived high supervisor collaborating climate reported lower sleep disturbance, job dissatisfaction, and action-taking cognitions. Workgroups that perceived high supervisor yielding climate and high supervisor forcing climate reported higher anxiety/depression, sleep disturbance, job dissatisfaction, and action-taking cognitions. Results supported a PJ climate mediation model when supervisors’ behavior was reported to be collaborative and yielding. Research limitations/implications The cross-sectional research design places limitations on conclusions about causality; thus, longitudinal studies are recommended. Practical implications Supervisor behavior in response to conflict may have far-reaching effects beyond those who are a party to the conflict. The more visible use of supervisor collaborative CMS may be beneficial. Social implications The economic costs associated with workplace conflict may be reduced through the application of these findings. Originality/value By applying multilevel theory and analysis, we extend workplace conflict theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Hamstring strain injuries (HSIs) are the most common injury type in Australian football and the rate of recurrence has been consistently high for a number of years. Long lasting neuromuscular inhibition has been noted in previously injured athletes but it is not known if this influences athletes adaptive response to training. Purpose To determine if elite Australian footballers with a prior unilateral HSI (previously injured group) display lesser improvements in eccentric hamstring strength during pre-season training compared to athletes without a history of HSI (control group). Study design Prospective cohort study. Methods Ninety-nine elite Australian footballers participated (17 with a history of unilateral HSI in the previous 12 month period). Eccentric hamstring strength was assessed at the start and end of pre-season training using an instrumented Nordic hamstring device. Change in eccentric strength across preseason was determine in absolute terms and normalised to start of preseason strength. Start of preseason strength was used as a covariate to control for differences in starting strength. Results The left and right limbs in the control group showed no difference in absolute or relative change (left limb absolute change, 60.7±72.9N; relative change, 1.28±0.34; right limb absolute change, 48.6±83.8N; relative change, 1.24±0.43) . Similarly, the injured and uninjured limbs from the previously injured group showed no difference for either absolute or relative measures of change (injured limb absolute change, 13.1±57.7N; relative change, 1.07±0.18; uninjured limb absolute change, 14.7±54.0N; relative change, 1.07±0.22N). The previously injured group displayed a significantly lesser increase in eccentric hamstring strength across the preseason (absolute change, 13.9±55.0; relative change, 1.07±0.20) compared to the control group (absolute change, 54.6±78.5; relative change, 1.26±0.39) for both absolute and relative measures (p < 0.001), even after controlling for differences in start of pre-season eccentric hamstring strength, which had a significant effect on strength improvement. Conclusion Elite Australian footballers with a unilateral HSI history displayed lesser improvements in eccentric hamstring strength across preseason training. The smaller improvements were not restricted to the previously injured limb as the contralateral limb also displayed similarly small improvements in eccentric strength. Whether this is the cause of or the result of injury remains to be seen, but it has the potential to contribute to the risk of hamstring strain re-injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hamstring strain injuries (HSIs) are the most prevalent injury in a number of sports, and while anterior cruciate ligament (ACL) injuries are less common, they are far more severe and have long-term implications, such as an increased risk of developing osteoarthritis later in life. Given the high incidence and severity of these injuries, they are key targets of injury preventive programs in elite sport. Evidence has shown that a previous severe knee injury (including ACL injury) increases the risk of HSI; however, whether the functional deficits that occur after HSI result in an increased risk of ACL injury has yet to be considered. In this clinical commentary, we present evidence that suggests that the link between previous HSI and increased risk of ACL injury requires further investigation by drawing parallels between deficits in hamstring function after HSI and in women athletes, who are more prone to ACL injury than men athletes. Comparisons between the neuromuscular function of the male and female hamstring has shown that women display lower hamstring-to-quadriceps strength ratios during isokinetic knee flexion and extension, increased activation of the quadriceps compared with the hamstrings during a stop-jump landing task, a greater time required to reach maximal isokinetic hamstring torque, and lower integrated myoelectrical hamstring activity during a sidestep cutting maneuver. Somewhat similarly, in athletes with a history of HSI, the previously injured limb, compared with the uninjured limb, displays lower eccentric knee flexor strength, a lower hamstrings-to-quadriceps strength ratio, lower voluntary myoelectrical activity during maximal knee flexor eccentric contraction, a lower knee flexor eccentric rate of torque development, and lower voluntary myoelectrical activity during the initial portion of eccentric contraction. Given that the medial and lateral hamstrings have different actions at the knee joint in the coronal plane, which hamstring head is previously injured might also be expected to influence the likelihood of future ACL. Whether the deficits in function after HSI, as seen in laboratory-based studies, translate to deficits in hamstring function during typical injurious tasks for ACL injury has yet to be determined but should be a consideration for future work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strain-based failure criteria have several advantages over stress-based failure criteria: they can account for elastic and inelastic strains, they utilise direct, observables effects instead of inferred effects (strain gauges vs. stress estimates), and model complete stress-strain curves including pre-peak, non-linear elasticity and post-peak strain weakening. In this study, a strain-based failure criterion derived from thermodynamic first principles utilising the concepts of continuum damage mechanics is presented. Furthermore, implementation of this failure criterion into a finite-element simulation is demonstrated and applied to the stability of underground mining coal pillars. In numerical studies, pillar strength is usually expressed in terms of critical stresses or stress-based failure criteria where scaling with pillar width and height is common. Previous publications have employed the finite-element method for pillar stability analysis using stress-based failure criterion such as Mohr-Coulomb and Hoek-Brown or stress-based scalar damage models. A novel constitutive material model, which takes into consideration anisotropy as well as elastic strain and damage as state variables has been developed and is presented in this paper. The damage threshold and its evolution are strain-controlled, and coupling of the state variables is achieved through the damage-induced degradation of the elasticity tensor. This material model is implemented into the finite-element software ABAQUS and can be applied to 3D problems. Initial results show that this new material model is capable of describing the non-linear behaviour of geomaterials commonly observed before peak strength is reached as well as post-peak strain softening. Furthermore, it is demonstrated that the model can account for directional dependency of failure behaviour (i.e. anisotropy) and has the potential to be expanded to environmental controls like temperature or moisture.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iterative computational models have been used to investigate the regulation of bone fracture healing by local mechanical conditions. Although their predictions replicate some mechanical responses and histological features, they do not typically reproduce the predominantly radial hard callus growth pattern observed in larger mammals. We hypothesised that this discrepancy results from an artefact of the models’ initial geometry. Using axisymmetric finite element models, we demonstrated that pre-defining a field of soft tissue in which callus may develop introduces high deviatoric strains in the periosteal region adjacent to the fracture. These bone-inhibiting strains are not present when the initial soft tissue is confined to a thin periosteal layer. As observed in previous healing models, tissue differentiation algorithms regulated by deviatoric strain predicted hard callus forming remotely and growing towards the fracture. While dilatational strain regulation allowed early bone formation closer to the fracture, hard callus still formed initially over a broad area, rather than expanding over time. Modelling callus growth from a thin periosteal layer successfully predicted the initiation of hard callus growth close to the fracture site. However, these models were still susceptible to elevated deviatoric strains in the soft tissues at the edge of the hard callus. Our study highlights the importance of the initial soft tissue geometry used for finite element models of fracture healing. If this cannot be defined accurately, alternative mechanisms for the prediction of early callus development should be investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this project is to investigate the strain-rate dependent mechanical behaviour of single living cells using both experimental and numerical techniques. The results revealed that living cells behave as porohyperlastic materials and that both solid and fluid phases within the cells play important roles in their mechanical responses. The research reported in this thesis provides a better understanding of the mechanisms underlying the cellular responses to external mechanical loadings and of the process of mechanical signal transduction in living cells. It would help us to enhance knowledge of and insight into the role of mechanical forces in supporting tissue regeneration or degeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural damage detection using modal strain energy (MSE) is one of the most efficient and reliable structural health monitoring techniques. However, some of the existing MSE methods have been validated for special types of structures such as beams or steel truss bridges which demands improving the available methods. The purpose of this study is to improve an efficient modal strain energy method to detect and quantify the damage in complex structures at early stage of formation. In this paper, a modal strain energy method was mathematically developed and then numerically applied to a fixed-end beam and a three-story frame including single and multiple damage scenarios in absence and presence of up to five per cent noise. For each damage scenario, all mode shapes and natural frequencies of intact structures and the first five mode shapes of assumed damaged structures were obtained using STRAND7. The derived mode shapes of each intact and damaged structure at any damage scenario were then separately used in the improved formulation using MATLAB to detect the location and quantify the severity of damage as compared to those obtained from previous method. It was found that the improved method is more accurate, efficient and convergent than its predecessors. The outcomes of this study can be safely and inexpensively used for structural health monitoring to minimize the loss of lives and property by identifying the unforeseen structural damages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acinetobacter baumannii isolate A1 was recovered in the United Kingdom in 1982 and belongs to global clone 1 (GC1). Here, we present its complete 3.91-Mbp genome sequence, generated via a combination of short-read sequencing (Illumina), long-read sequencing (PacBio), and manual finishing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Explosive ordnance disposal (EOD) often requires technicians to wear multiple protective garments in challenging environmental conditions. The accumulative effect of increased metabolic cost coupled with decreased heat dissipation associated with these garments predisposes technicians to high levels of physiological strain. It has been proposed that a perceptual strain index (PeSI) using subjective ratings of thermal sensation and perceived exertion as surrogate measures of core body temperature and heart rate, may provide an accurate estimation of physiological strain. Therefore, this study aimed to determine if the PeSI could estimate the physiological strain index (PSI) across a range of metabolic workloads and environments while wearing heavy EOD and chemical protective clothing. Methods Eleven healthy males wore an EOD and chemical protective ensemble while walking on a treadmill at 2.5, 4 and 5.5 km·h− 1 at 1% grade in environmental conditions equivalent to wet bulb globe temperature (WBGT) 21, 30 and 37 °C. WBGT conditions were randomly presented and a maximum of three randomised treadmill walking trials were completed in a single testing day. Trials were ceased at a maximum of 60-min or until the attainment of termination criteria. A Pearson's correlation coefficient, mixed linear model, absolute agreement and receiver operating characteristic (ROC) curves were used to determine the relationship between the PeSI and PSI. Results A significant moderate relationship between the PeSI and the PSI was observed [r = 0.77; p < 0.001; mean difference = 0.8 ± 1.1 a.u. (modified 95% limits of agreement − 1.3 to 3.0)]. The ROC curves indicated that the PeSI had a good predictive power when used with two, single-threshold cut-offs to differentiate between low and high levels of physiological strain (area under curve: PSI three cut-off = 0.936 and seven cut-off = 0.841). Conclusions These findings support the use of the PeSI for monitoring physiological strain while wearing EOD and chemical protective clothing. However, future research is needed to confirm the validity of the PeSI for active EOD technicians operating in the field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Besides the elastic stiffness, the relaxation behavior of single living cells is also of interest of various researchers when studying cell mechanics. It is hypothesized that the relaxation response of the cells is governed by both intrinsic viscoelasticity of the solid phase and fluid-solid interactions mechanisms. There are a number of mechanical models have been developed to investigate the relaxation behavior of single cells. However, there is lack of model enable to accurately capture both of the mechanisms. Therefore, in this study, the porohyperelastic (PHE) model, which is an extension of the consolidation theory, combined with inverse Finite Element Analysis (FEA) technique was used at the first time to investigate the relaxation response of living chondrocytes. This model was also utilized to study the dependence of relaxation behavior of the cells on strain-rates. The stress-relaxation experiments under the various strain-rates were conducted with the Atomic Force Microscopy (AFM). The results have demonstrated that the PHE model could effectively capture the stress-relaxation behavior of the living chondrocytes, especially at intermediate to high strain-rates. Although this model gave some errors at lower strain-rates, its performance was acceptable. Therefore, the PHE model is properly a promising model for single cell mechanics studies. Moreover, it has been found that the hydraulic permeability of living chondrocytes reduced with decreasing of strain-rates. It might be due to the intracellular fluid volume fraction and the fluid pore pressure gradients of chondrocytes were higher when higher strain-rates applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urinary tract infections (UTIs) are among the most common infectious diseases of humans, with Escherichia coli responsible for >80% of all cases. One extreme of UTI is asymptomatic bacteriuria (ABU), which occurs as an asymptomatic carrier state that resembles commensalism. To understand the evolution and molecular mechanisms that underpin ABU, the genome of the ABU E. coli strain VR50 was sequenced. Analysis of the complete genome indicated that it most resembles E. coli K-12, with the addition of a 94-kb genomic island (GI-VR50-pheV), eight prophages, and multiple plasmids. GI-VR50-pheV has a mosaic structure and contains genes encoding a number of UTI-associated virulence factors, namely, Afa (afimbrial adhesin), two autotransporter proteins (Ag43 and Sat), and aerobactin. We demonstrated that the presence of this island in VR50 confers its ability to colonize the murine bladder, as a VR50 mutant with GI-VR50-pheV deleted was attenuated in a mouse model of UTI in vivo. We established that Afa is the island-encoded factor responsible for this phenotype using two independent deletion (Afa operon and AfaE adhesin) mutants. E. coli VR50afa and VR50afaE displayed significantly decreased ability to adhere to human bladder epithelial cells. In the mouse model of UTI, VR50afa and VR50afaE displayed reduced bladder colonization compared to wild-type VR50, similar to the colonization level of the GI-VR50-pheV mutant. Our study suggests that E. coli VR50 is a commensal-like strain that has acquired fitness factors that facilitate colonization of the human bladder.