310 resultados para SHUNT PORTOSSISTÊMICO


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Portosystemic shunt, an hepatobiliary anomaly, much common in dogs and less frequent in cats, can be detected by several diagnostic methods. Among them, the one which stands out is ultrasonography due to its numerous advantages: noninvasive, quick, accessible, relatively low cost and provides useful information relating to the other systems, apart from being a highly sensitive method. Portosystemic shunt diagnosis using ultrasonography becomes highly sensitive when associated with B-mode, color Doppler and pulsed Doppler. A bibliographic survey about portosystemic shunt ultrasonographic diagnosis was carried out, and the main ultrasonographic signals were: decreased hepatic size, difficulty in blood vessels visualization, presence of an anomalous vessel, tortuous with turbulent flow and, finally, increased portal blood flow velocity near the shunting vessel

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foram realizados o estudo morfométrico e o estudo hemodinâmico da veia porta em vinte cães clinicamente normais, de idade igual e inferior a 120 dias e em quatorze cães portadores de shunt portossistêmico, de idades entre 90 e 360 dias. Nos cães do grupo controle, as margens hepáticas apresentaram-se entre 1,50cm e 3,00cm caudalmente à margem costal. Os diâmetros médios da veia porta (VP), veia cava caudal (VCC) e aorta abdominal (AO) obtidas foram respectivamente, 0,38cm, 0,37cm e 0,41cm. As proporções entre os diâmetros médios VP/VCC e VP/AO apresentaram médias de 1,10 e 0,94, respectivamente. As médias das áreas da VP, VCC e AO resultaram respectivamente em 0,12cm2 , 0,11cm2 e 0,14cm2. No estudo hemodinâmico da VP destes animais, utilizando-se o ultrassom Doppler, a velocidade média de fluxo sangüíneo portal (VMFSP) mediu 17,76cm/s. A média de fluxo sangüíneo portal (FSP) resultou em 83,11ml/min/kg. O índice de congestão (IC) apresentou média de 0,006. Para o grupo de cães portadores de shunt portossistêmico, o fígado apresentou redução de seu volume, sendo as margens hepáticas visibilizadas entre 1,00cm e 2,00cm cranialmente à margem costal. No estudo morfométrico, as médias dos diâmetros médios obtidos de VP, VCC e AO resultaram respectivamente em 0,40cm, 0,74cm e 0,56cm. As proporções entre os diâmetros médios VP/VCC e VP/AO resultaram respectivamente em 0,54 e 0,69. As médias das áreas de VP, VCC e AO resultaram respectivamente em 0,14cm2, 0,31cm2 e 0,25cm2. Ao ultrassom Doppler a VMFSP mediu 22,29cm/s e a média do IC da VP obtido foi de 0,006.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O desvio vascular portossistêmico pode ser congênito ou adquirido nos cães. A enfermidade pode levar a alterações neurológicas decorrentes de encefalopatia hepática e a hiperamonenia é um dos mecanismos implicados na fisiopatologia deste quadro. O tratamento clínico visa a reduzir os níveis séricos de amônia com o uso de antibióticos e lactulose. em humanos com hepatopatias, os probióticos podem ser utilizados para reduzir a hiperamonemia. A resposta clínica e laboratorial de um cão com desvio vascular portossistêmico foi demonstrada com a utilização de lactulose e de probiótico, isoladamente e associados, sendo que a melhor evolução foi obtida na terapia conjunta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a database ATP (Alternative Transient Program) simulated waveforms for shunt reactor switching cases with vacuum breakers in motor circuits following interruption of the starting current. The targeted objective is to provide multiple reignition simulated data for diagnostic and prognostic algorithms development, but also to help ATP users with practical study cases and component data compilation for shunt reactor switching. This method can be easily applied with different data for the different dielectric curves of circuit-breakers and networks. This paper presents design details, discusses some of the available cases and the advantages of such simulated data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When the supply voltages are balanced and sinusoidal, load compensation can give both unity power factor (UPF) and perfect harmonic cancellation (PHC) source currents. But under distorted supply voltages, achieving both UPF and PHC currents are not possible and contradictory to each other. Hence there should be an optimal performance between these two important compensation goals. This paper presents an optimal control algorithm for load compensation under unbalanced and distorted supply voltages. In this algorithm source currents are compensated for reactive, imbalance components and harmonic distortions set by the limits. By satisfying the harmonic distortion limits and power balance, this algorithm gives the source currents which will provide the maximum achievable power factor. The detailed simulation results using MATLAB are presented to support the performance of the proposed optimal control algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Voltage imbalance in capacitors is a well-known problem in compensator topologies which use two or more capacitors. This imbalance may exist even if the load does not contain any DC component, due to practical factors. However, when the load contains a DC part, the voltage imbalance problem becomes critical. In this paper, a two-quadrant chopper has been used to regulate the capacitor voltages in a two-capacitor compensator structure. Two different control strategies for the two-quadrant chopper to equalize the voltage of the capacitors have been proposed. The strategies are validated through detailed simulation studies. Experiments have also been carried out to validate the hysteresis control of chopper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flying capacitor multilevel inverter (FCMLI) is a multiple voltage level inverter topology intended for high-power and high-voltage operations at low distortion. It uses capacitors, called flying capacitors, to clamp the voltage across the power semiconductor devices. A method for controlling the FCMLI is proposed which ensures that the flying capacitor voltages remain nearly constant using the preferential charging and discharging of these capacitors. A static synchronous compensator (STATCOM) and a static synchronous series compensator (SSSC) based on five-level flying capacitor inverters are proposed. Control schemes for both the FACTS controllers are developed and verified in terms of voltage control, power flow control, and power oscillation damping when installed in a single-machine infinite bus (SMIB) system. Simulation studies are performed using PSCAD/EMTDC to validate the efficacy of the control scheme and the FCMLI-based flexible alternating current transmission system (FACTS) controllers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the performance of voltage-source converter-based shunt and series compensators used for load voltage control in electrical power distribution systems has been analyzed and compared, when a nonlinear load is connected across the load bus. The comparison has been made based on the closed-loop frequency resopnse characteristics of the compensated distribution system. A distribution static compensator (DSTATCOM) as a shunt device and a dynamic voltage restorer (DVR) as a series device are considered in the voltage-control mode for the comparison. The power-quality problems which these compensator address include voltage sags/swells, load voltage harmonic distortions, and unbalancing. The effect of various system parameters on the control performance of the compensator can be studied using the proposed analysis. In particular, the performance of the two compensators are compared with the strong ac supply (stiff source) and weak ac-supply (non-still source) distribution system. The experimental verification of the analytical results derived has been obtained using a laboratory model of the single-phase DSTATCOM and DVR. A generalized converter topology using a cascaded multilevel inverter has been proposed for the medium-voltage distribution system. Simulation studies have been performed in the PSCAD/EMTDC software to verify the results in the three-phase system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Circuit-breakers (CBs) are subject to electrical stresses with restrikes during capacitor bank operation. Stresses are caused by the overvoltages across CBs, the interrupting currents and the rate of rise of recovery voltage (RRRV). Such electrical stresses also depend on the types of system grounding and the types of dielectric strength curves. The aim of this study is to demonstrate a restrike waveform predictive model for a SF6 CB that considered the types of system grounding: grounded and non-grounded and the computation accuracy comparison on the application of the cold withstand dielectric strength and the hot recovery dielectric strength curve including the POW (point-on-wave) recommendations to make an assessment of increasing the CB remaining life. The simulation of SF6 CB stresses in a typical 400 kV system was undertaken and the results in the applications are presented. The simulated restrike waveforms produced with the identified features using wavelet transform can be used for restrike diagnostic algorithm development with wavelet transform to locate a substation with breaker restrikes. This study found that the hot withstand dielectric strength curve has less magnitude than the cold withstand dielectric strength curve for restrike simulation results. Computation accuracy improved with the hot withstand dielectric strength and POW controlled switching can increase the life for a SF6 CB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the performance of distance relays when applied to transmission system equipped with shunt FACTS device, Static Synchronous Compensator (STATCOM) is described. The aim of the proposed study is to evaluate the performance of distance relays when STATCOM is incorporated at the mid point of transmission lines for voltage control. A detailed model of STATCOM and its control strategy is presented. The presence of these devices significantly affects apparent impedance seen by the distance relays due to their rapid response to different power system configurations. The distance relay is evaluated for different loading conditions and for different fault locations. The faults are created during various pre-fault loading conditions. The studies are performed on 400KV and 132KV systems and the results are presented. Simulation studies are carried out using transient simulation software, PSCAD/EMTDC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An extension of Rizk's analysis to cover any type of switching is presented for calculating the residual current and recovery voltage in a singlephase switched transmission system. Equations for the determination of the current and voltage are shown, and the method has been used for the analysis of a series- and shunt-compensated line.Three possible switching methods for the effective control of the recovery voltage and residual current are discussed: normal switching, switching at the ends of the line and switching of the series capacitors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Handling unbalanced and non-linear loads in a three-phase AC power supply has always been a difficult issue. This has been addressed in the literature by either using fast controllers in the fundamental rotating reference frame or using separate controllers in reference frames specific to the harmonics. In the former case, the controller needs to be fast and in the latter case, besides the need for many controllers, negative-sequence components need to be extracted from the measured signal. This study proposes a control scheme for harmonic and unbalance compensation of a three-phase uninterruptible power supply wherein the problems mentioned above are addressed. The control takes place in the fundamental positive-sequence reference frame using only a set of feedback and feed-forward compensators. The harmonic components are extracted by a process of frame transformations and used as feed-forward compensation terms in the positive-sequence fundamental reference frame. This study uses a method wherein the measured signal itself is used for fundamental negative-sequence compensation. As the feed-forward compensator handles the high-bandwidth components, the feedback compensator can be a simple low-bandwidth one. This control algorithm is explained and validated experimentally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Handling unbalanced and non-linear loads in a three-phase AC power supply has always been a difficult issue. This has been addressed in the literature by either using fast controllers in the fundamental rotating reference frame or using separate controllers in reference frames specific to the harmonics. In the former case, the controller needs to be fast and in the latter case, besides the need for many controllers, negative-sequence components need to be extracted from the measured signal. This study proposes a control scheme for harmonic and unbalance compensation of a three-phase uninterruptible power supply wherein the problems mentioned above are addressed. The control takes place in the fundamental positive-sequence reference frame using only a set of feedback and feed-forward compensators. The harmonic components are extracted by a process of frame transformations and used as feed-forward compensation terms in the positive-sequence fundamental reference frame. This study uses a method wherein the measured signal itself is used for fundamental negative-sequence compensation. As the feed-forward compensator handles the high-bandwidth components, the feedback compensator can be a simple low-bandwidth one. This control algorithm is explained and validated experimentally.