984 resultados para SEM (Scanning Electron Microscopy)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The single-layer and multilayer Sb-rich AgInSbTe films were irradiated by a single femtosecond laser pulse with the duration of 120 fs. The morphological feature resulting from the laser irradiation have been investigated by scanning electron microscopy and atom force microscopy. For the single-layer film, the center of the irradiated spot is a dark depression and the border is a bright protrusion; however, for the multilayer film, the center morphology changes from a depression to a protrusion as the energy increases. The crystallization threshold fluence of the single-layer and the multilayer films is 46.36 mJ/cm(2), 63.74 mJ/cm(2), respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two species of aspidogastreans, namely Aspidogaster ijimai and A. conchicola, were studied by scanning electron microscopy. In nine lakes and an old river course, the Tian'ezhou oxbow, investigated in the flood plain of the Yangtze River, A. ijimai was obtained from the common carp (Cyprinus carpio) in three lakes, and A. conchicola from the black carp Mylopharyngodon piceus in three lakes and the oxbow. In none of the localities, however, were the two species found together. It is suggested that A. ijimai may be considered as a specialist parasite for the common carp, at least in the flood-plain lakes of the Yangtze River. The two parasites were similar in many aspects of their morphology. Their bodies can both be separated into a dorsal part and a ventral disc, with the body surface of the dorsal part elevated by transverse folds, and the disc subdivided into alveoli by transverse and longitudinal septa, although the number of alveoli was different in the two species. The depression on the ventral surface of the neck region was prominent for both species, and their ventral disc was covered densely with non-ciliated bulbous papillae. The position of mouth, osmo-regulatory pore and marginal organ was also similar for A. ijimai and A. conchicola. However, microridges in the trough of the folds in the neck region and numerous small pits on the upper part of the septa were found exclusively in A. ijimai, but uniciliated sensory papillae in A. conchicola.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Self-assembled InAs/AlAs quantum dots embedded in a resonant tunneling diode device structure are grown by molecular beam epitaxy. Through the selective etching in a C6H8O7 center dot H2O-K3C6H5O7 center dot H2O-H2O2 buffer solution, 310 nm GaAs capping layers are removed and the InAs/AlAs quantum dots are observed by field-emission scanning electron microscopy. It is shown that as-fabricated quantum dots have a diameter of several tens of nanometers and a density of 10(10) cm(-2) order. The images taken by this means are comparable or slightly better than those of transmission electron microscopy. The undercut of the InAs/AlAs layer near the edges of mesas is detected and that verifies the reliability of the quantum dot images. The inhomogeneous oxidation of the upper AlAs barrier in H2O2 is also observed. By comparing the morphologies of the mesa edge adjacent regions and the rest areas of the sample, it is concluded that the physicochemical reaction introduced in this letter is diffusion limited.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a novel contactless and nondestructive method called the surface electron beam induced voltage (SEBIV) method for characterizing semiconductor materials and devices. The SEBIV method is based on the detection of the surface potential induced by electron beams of scanning electron microscopy (SEM). The core part of the SEBIV detection set-up is a circular metal detector placed above the sample surface. The capacitance between the circular detector and whole surface of the sample is estimated to be about 0.64 pf It is large enough for the detection of the induced surface potential. The irradiation mode of electron beam (e-beam) influences the signal generation. When the e-beam irradiates on the surface of semiconductors continuously, a differential signal is obtained. The real distribution of surface potentials can be obtained when a pulsed e-beam with a fixed frequency is used for irradiation and a lock-in amplifier is employed for detection. The polarity of induced potential depends on the structure of potential barriers and surface states of samples. The contrast of SEBIV images in SEM changes with irradiation time and e-beam intensity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

info:eu-repo/semantics/published