936 resultados para Reproducibility of Results


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Serologic methods have been used widely to test for celiac disease and have gained importance in diagnostic definition and in new epidemiologic findings. However, there is no standardization, and there are no reference protocols and materials. METHODS: The European working group on Serological Screening for Celiac Disease has defined robust noncommercial test protocols for immunoglobulin (Ig)G and IgA gliadin antibodies and for IgA autoantibodies against endomysium and tissue transglutaminase. Standard curves were linear in the decisive range, and intra-assay variation coefficients were less than 5% to 10%. Calibration was performed with a group reference serum. Joint cutoff limits were used. Seven laboratories took part in the final collaborative study on 252 randomized sera classified by histology (103 pediatric and adult patients with active celiac disease, 89 disease control subjects, and 60 blood donors). RESULTS: IgA autoantibodies against endomysium and tissue transglutaminase rendered superior sensitivity (90% and 93%, respectively) and specificity (99% and 95%, respectively) over IgA and IgG gliadin antibodies. Tissue transglutaminase antibody testing showed superior receiver operating characteristic performance compared with gliadin antibodies. The K values for interlaboratory reproducibility showed superiority for IgA endomysium (0.93) in comparison with tissue transglutaminase antibodies (0.83) and gliadin antibodies (0.82 for IgG, 0.62 for IgA). CONCLUSIONS: Basic criteria of standardization and quality assessment must be fulfilled by any given test protocol proposed for serologic investigation of celiac disease. The working group has produced robust test protocols and reference materials available for standardization to further improve reliability of serologic testing for celiac disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Strict lifelong compliance to a gluten-free diet (GFD) minimizes the long-term risk of mortality, especially from lymphoma, in adult celiac disease (CD). Although serum IgA antitransglutaminase (IgA-tTG-ab), like antiendomysium (IgA-EMA) antibodies, are sensitive and specific screening tests for untreated CD, their reliability as predictors of strict compliance to and dietary transgressions from a GFD is not precisely known. We aimed to address this question in consecutively treated adult celiacs. METHODS: In a cross-sectional study, 95 non-IgA deficient adult (median age: 41 yr) celiacs on a GFD for at least 1 yr (median: 6 yr) were subjected to 1) a dietician-administered inquiry to pinpoint and quantify the number and levels of transgressions (classified as moderate or large, using as a cutoff value the median gluten amount ingested in the overall noncompliant patients of the series) over the previous 2 months, 2) a search for IgA-tTG-ab and -EMA, and 3) perendoscopic duodenal biopsies. The ability of both antibodies to discriminate celiacs with and without detected transgressions was described using receiver operating characteristic curves and quantified as to sensitivity and specificity, according to the level of transgressions. RESULTS: Forty (42%) patients strictly adhered to a GFD, 55 (58%) had committed transgressions, classified as moderate (< or = 18 g of gluten/2 months; median number 6) in 27 and large (>18 g; median number 69) in 28. IgA-tTG-ab and -EMA specificity (proportion of correct recognition of strictly compliant celiacs) was 0.97 and 0.98, respectively, and sensitivity (proportion of correct recognition of overall, moderate, and large levels of transgressions) was 0.52, 0.31, and 0.77, and 0.62, 0.37, and 0.86, respectively. IgA-tTG-ab and -EMA titers were correlated (p < 0.001) to transgression levels (r = 0.560 and R = 0.631, respectively) and one to another (p < 0.001) in the whole patient population (r = 0.834, N = 84) as in the noncompliant (r = 0.915, N = 48) group. Specificity and sensitivity of IgA-tTG-ab and IgA-EMA for recognition of total villous atrophy in patients under a GFD were 0.90 and 0.91, and 0.60 and 0.73, respectively. CONCLUSIONS: In adult CD patients on a GFD, IgA-tTG-ab are poor predictors of dietary transgressions. Their negativity is a falsely secure marker of strict diet compliance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Overall survival (OS) can be observed only after prolonged follow-up, and any potential effect of first-line therapies on OS may be confounded by the effects of subsequent therapy. We investigated whether tumor response, disease control, progression-free survival (PFS), or time to progression (TTP) could be considered a valid surrogate for OS to assess the benefits of first-line therapies for patients with metastatic breast cancer. PATIENTS AND METHODS: Individual patient data were collected on 3,953 patients in 11 randomized trials that compared an anthracycline (alone or in combination) with a taxane (alone or in combination with an anthracycline). Surrogacy was assessed through the correlation between the end points as well as through the correlation between the treatment effects on the end points. RESULTS: Tumor response (survival odds ratio [OR], 6.2; 95% CI, 5.3 to 7.0) and disease control (survival OR, 5.5; 95% CI, 4.8 to 6.3) were strongly associated with OS. PFS (rank correlation coefficient, 0.688; 95% CI, 0.686 to 0.690) and TTP (rank correlation coefficient, 0.682; 95% CI, 0.680 to 0.684) were moderately associated with OS. Response log ORs were strongly correlated with PFS log hazard ratios (linear coefficient [rho], 0.96; 95% CI, 0.73 to 1.19). Response and disease control log ORs and PFS and TTP log hazard ratios were poorly correlated with log hazard ratios for OS, but the confidence limits of rho were too wide to be informative. CONCLUSION: No end point could be demonstrated as a good surrogate for OS in these trials. Tumor response may be an acceptable surrogate for PFS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As more diagnostic testing options become available to physicians, it becomes more difficult to combine various types of medical information together in order to optimize the overall diagnosis. To improve diagnostic performance, here we introduce an approach to optimize a decision-fusion technique to combine heterogeneous information, such as from different modalities, feature categories, or institutions. For classifier comparison we used two performance metrics: The receiving operator characteristic (ROC) area under the curve [area under the ROC curve (AUC)] and the normalized partial area under the curve (pAUC). This study used four classifiers: Linear discriminant analysis (LDA), artificial neural network (ANN), and two variants of our decision-fusion technique, AUC-optimized (DF-A) and pAUC-optimized (DF-P) decision fusion. We applied each of these classifiers with 100-fold cross-validation to two heterogeneous breast cancer data sets: One of mass lesion features and a much more challenging one of microcalcification lesion features. For the calcification data set, DF-A outperformed the other classifiers in terms of AUC (p < 0.02) and achieved AUC=0.85 +/- 0.01. The DF-P surpassed the other classifiers in terms of pAUC (p < 0.01) and reached pAUC=0.38 +/- 0.02. For the mass data set, DF-A outperformed both the ANN and the LDA (p < 0.04) and achieved AUC=0.94 +/- 0.01. Although for this data set there were no statistically significant differences among the classifiers' pAUC values (pAUC=0.57 +/- 0.07 to 0.67 +/- 0.05, p > 0.10), the DF-P did significantly improve specificity versus the LDA at both 98% and 100% sensitivity (p < 0.04). In conclusion, decision fusion directly optimized clinically significant performance measures, such as AUC and pAUC, and sometimes outperformed two well-known machine-learning techniques when applied to two different breast cancer data sets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As many as 20-70% of patients undergoing breast conserving surgery require repeat surgeries due to a close or positive surgical margin diagnosed post-operatively [1]. Currently there are no widely accepted tools for intra-operative margin assessment which is a significant unmet clinical need. Our group has developed a first-generation optical visible spectral imaging platform to image the molecular composition of breast tumor margins and has tested it clinically in 48 patients in a previously published study [2]. The goal of this paper is to report on the performance metrics of the system and compare it to clinical criteria for intra-operative tumor margin assessment. The system was found to have an average signal to noise ratio (SNR) >100 and <15% error in the extraction of optical properties indicating that there is sufficient SNR to leverage the differences in optical properties between negative and close/positive margins. The probe had a sensing depth of 0.5-2.2 mm over the wavelength range of 450-600 nm which is consistent with the pathologic criterion for clear margins of 0-2 mm. There was <1% cross-talk between adjacent channels of the multi-channel probe which shows that multiple sites can be measured simultaneously with negligible cross-talk between adjacent sites. Lastly, the system and measurement procedure were found to be reproducible when evaluated with repeated measures, with a low coefficient of variation (<0.11). The only aspect of the system not optimized for intra-operative use was the imaging time. The manuscript includes a discussion of how the speed of the system can be improved to work within the time constraints of an intra-operative setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We conducted a pilot study on 10 patients undergoing general surgery to test the feasibility of diffuse reflectance spectroscopy in the visible wavelength range as a noninvasive monitoring tool for blood loss during surgery. Ratios of raw diffuse reflectance at wavelength pairs were tested as a first-pass for estimating hemoglobin concentration. Ratios can be calculated easily and rapidly with limited post-processing, and so this can be considered a near real-time monitoring device. We found the best hemoglobin correlations were when ratios at isosbestic points of oxy- and deoxyhemoglobin were used, specifically 529/500 nm. Baseline subtraction improved correlations, specifically at 520/509 nm. These results demonstrate proof-of-concept for the ability of this noninvasive device to monitor hemoglobin concentration changes due to surgical blood loss. The 529/500 nm ratio also appears to account for variations in probe pressure, as determined from measurements on two volunteers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We developed a ratiometric method capable of estimating total hemoglobin concentration from optically measured diffuse reflectance spectra. The three isosbestic wavelength ratio pairs that best correlated to total hemoglobin concentration independent of saturation and scattering were 545/390, 452/390, and 529/390 nm. These wavelength pairs were selected using forward Monte Carlo simulations which were used to extract hemoglobin concentration from experimental phantom measurements. Linear regression coefficients from the simulated data were directly applied to the phantom data, by calibrating for instrument throughput using a single phantom. Phantoms with variable scattering and hemoglobin saturation were tested with two different instruments, and the average percent errors between the expected and ratiometrically-extracted hemoglobin concentration were as low as 6.3%. A correlation of r = 0.88 between hemoglobin concentration extracted using the 529/390 nm isosbestic ratio and a scalable inverse Monte Carlo model was achieved for in vivo dysplastic cervical measurements (hemoglobin concentrations have been shown to be diagnostic for the detection of cervical pre-cancer by our group). These results indicate that use of such a simple ratiometric method has the potential to be used in clinical applications where tissue hemoglobin concentrations need to be rapidly quantified in vivo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capable of three-dimensional imaging of the cornea with micrometer-scale resolution, spectral domain-optical coherence tomography (SDOCT) offers potential advantages over Placido ring and Scheimpflug photography based systems for accurate extraction of quantitative keratometric parameters. In this work, an SDOCT scanning protocol and motion correction algorithm were implemented to minimize the effects of patient motion during data acquisition. Procedures are described for correction of image data artifacts resulting from 3D refraction of SDOCT light in the cornea and from non-idealities of the scanning system geometry performed as a pre-requisite for accurate parameter extraction. Zernike polynomial 3D reconstruction and a recursive half searching algorithm (RHSA) were implemented to extract clinical keratometric parameters including anterior and posterior radii of curvature, central cornea optical power, central corneal thickness, and thickness maps of the cornea. Accuracy and repeatability of the extracted parameters obtained using a commercial 859nm SDOCT retinal imaging system with a corneal adapter were assessed using a rigid gas permeable (RGP) contact lens as a phantom target. Extraction of these parameters was performed in vivo in 3 patients and compared to commercial Placido topography and Scheimpflug photography systems. The repeatability of SDOCT central corneal power measured in vivo was 0.18 Diopters, and the difference observed between the systems averaged 0.1 Diopters between SDOCT and Scheimpflug photography, and 0.6 Diopters between SDOCT and Placido topography.