243 resultados para Radiofrequency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

[Letter to the Editor] I read with great interest the article recently published in the Journal of PeriAnesthesia Nursing that examined the utility of using dexmedetomidine (DEX) as an adjunct to midazolam and fentanyl for procedural sedation and analgesia during radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF).1 With the view toward advancing knowledge about more effective medications for sedation in this challenging context, I offer the following insights for readers to consider regarding this study...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The uniform growth of copper oxide nanowires on the top of copper plate has been investigated during the exposure to radiofrequency plasma discharge in respect to plasma properties and its localization. The copper samples of 10 mm radius and 1 mm in thickness were exposed to argon-oxygen plasma created at discharge power of 150 W. After 10 min, almost uniform growth of nanowires was achieved over large surface. There were significant distortions in nanowire length and shape near the edges. Based on the experimental results, we developed a theoretical model, which took into account a balance in heat released at the flow of the current to the nanowire and rejected from the nanowire. This model established a dependence of the maximal length of the nanowire at dependence on the plasma parameters, where the limiting factor for nanowire growth and distortions in distribution are ballistic effects of ions and their local fluxes. In contrast, the plasma heating by potential interactions of species has very little influence on the length and smaller deviations in flux are allowed for uniformity of growth

Relevância:

20.00% 20.00%

Publicador:

Resumo:

中国科学院近代物理研究所正在进行等离子体直接注入方案的研究,以便为重离子物理研究提供稳定可靠的高流强束流。由于工作频率较低,用于等离子体直接注入方案的RFQ腔体采用了适合于低频的四杆型结构。在完成束流动力学设计的前提下,研究了RFQ腔体支撑臂的各参数对并联阻抗的影响。由于突出电极之间存在着一定大小的电容,会对腔体的性能产生影响,为使腔体达到最优化的设计,进行了突出电极对并联阻抗及场平整性的影响的研究,并给出了突出电极的取值范围。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Arrhythmia recurrence after cardiac radiofrequency ablation (RFA) for atrial fibrillation has been linked to conduction through discontinuous lesion lines. Intraprocedural visualization and corrective ablation of lesion line discontinuities could decrease postprocedure atrial fibrillation recurrence. Intracardiac acoustic radiation force impulse (ARFI) imaging is a new imaging technique that visualizes RFA lesions by mapping the relative elasticity contrast between compliant-unablated and stiff RFA-treated myocardium. OBJECTIVE: To determine whether intraprocedure ARFI images can identify RFA-treated myocardium in vivo. METHODS: In 8 canines, an electroanatomical mapping-guided intracardiac echo catheter was used to acquire 2-dimensional ARFI images along right atrial ablation lines before and after RFA. ARFI images were acquired during diastole with the myocardium positioned at the ARFI focus (1.5 cm) and parallel to the intracardiac echo transducer for maximal and uniform energy delivery to the tissue. Three reviewers categorized each ARFI image as depicting no lesion, noncontiguous lesion, or contiguous lesion. For comparison, 3 separate reviewers confirmed RFA lesion presence and contiguity on the basis of functional conduction block at the imaging plane location on electroanatomical activation maps. RESULTS: Ten percent of ARFI images were discarded because of motion artifacts. Reviewers of the ARFI images detected RFA-treated sites with high sensitivity (95.7%) and specificity (91.5%). Reviewer identification of contiguous lesions had 75.3% specificity and 47.1% sensitivity. CONCLUSIONS: Intracardiac ARFI imaging was successful in identifying endocardial RFA treatment when specific imaging conditions were maintained. Further advances in ARFI imaging technology would facilitate a wider range of imaging opportunities for clinical lesion evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have previously shown that intracardiac acoustic radiation force impulse (ARFI) imaging visualizes tissue stiffness changes caused by radiofrequency ablation (RFA). The objectives of this in vivo study were to (1) quantify measured ARFI-induced displacements in RFA lesion and unablated myocardium and (2) calculate the lesion contrast (C) and contrast-to-noise ratio (CNR) in two-dimensional ARFI and conventional intracardiac echo images. In eight canine subjects, an ARFI imaging-electroanatomical mapping system was used to map right atrial ablation lesion sites and guide the acquisition of ARFI images at these sites before and after ablation. Readers of the ARFI images identified lesion sites with high sensitivity (90.2%) and specificity (94.3%) and the average measured ARFI-induced displacements were higher at unablated sites (11.23 ± 1.71 µm) than at ablated sites (6.06 ± 0.94 µm). The average lesion C (0.29 ± 0.33) and CNR (1.83 ± 1.75) were significantly higher for ARFI images than for spatially registered conventional B-mode images (C = -0.03 ± 0.28, CNR = 0.74 ± 0.68).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pediatric ophthalmologists increasingly recognize that the ideal site for intraocular lens (IOL) implantation is in the bag for aphakic eyes, but it is always very difficult via conventional technique. We conducted a prospective case series study to investigate the success rate and clinical outcomes of capsular bag reestablishment and in-the-bag IOL implantation via secondary capsulorhexis with radiofrequency diathermy (RFD) in pediatric aphakic eyes, in which twenty-two consecutive aphakic pediatric patients (43 aphakic eyes) enrolled in the Childhood Cataract Program of the Chinese Ministry of Health were included. The included children underwent either our novel technique for secondary IOL implantation (with RFD) or the conventional technique (with a bent needle or forceps), depending on the type of preoperative proliferative capsular bag present. In total, secondary capsulorhexis with RFD was successfully applied in 32 eyes (32/43, 74.4%, age 5.6±2.3 years), of which capsular bag reestablishment and in-the-bag IOL implantation were both achieved in 30 eyes (30/43, 70.0%), but in the remaining 2 eyes (2/32, 6.2%) the IOLs were implanted in the sulcus with a capsular bag that was too small. Secondary capsulorhexis with conventional technique was applied in the other 11 eyes (11/43, 25.6%, age 6.9±2.3 years), of which capsular bag reestablishment and in-the-bag IOL implantation were both achieved only in 3 eyes(3/43, 7.0%), and the IOLs were implanted in the sulcus in the remaining 8 eyes. A doughnut-like proliferative capsular bag with an extensive Soemmering ring (32/43, 74.4%) was the main success factor for secondary capsulorhexis with RFD, and a sufficient capsular bag size (33/43, 76.7%) was an additional factor in successful in-the-bag IOL implantation. In conclusion, RFD secondary capsulorhexis technique has 70% success rate in the capsular bag reestablishment and in-the-bag IOL implantation in pediatric aphakic eyes, particularly effective in cases with a doughnut-like, extensively proliferative Soemmering ring. © 2013 Luo et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bio-compatible magnetic fluids having high saturation magnetization find immense applications in various biomedical fields. Aqueous ferrofluids of superparamagnetic iron oxide nanoparticles with narrow size distribution, high shelf life and good stability is realized by controlled chemical co-precipitation process. The crystal structure is verified by X-ray diffraction technique. Particle sizes are evaluated by employing Transmission electron microscopy. Room temperature and low-temperature magnetic measurements were carried out with Superconducting Quantum Interference Device. The fluid exhibits good magnetic response even at very high dilution (6.28 mg/cc). This is an advantage for biomedical applications, since only a small amount of iron is to be metabolised by body organs. Magnetic field induced transmission measurements carried out at photon energy of diode laser (670 nm) exhibited excellent linear dichroism. Based on the structural and magnetic measurements, the power loss for the magnetic nanoparticles under study is evaluated over a range of radiofrequencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVETo determine the current status of the literature regarding the clinical efficacy and complication rates of cryoablation vs radiofrequency ablation in the treatment of small renal tumours.METHODSA review of the literature was conducted. There was no language restriction. Studies were obtained from the following sources: MEDLINE, EMBASE and LILACS.Inclusion criteria were (i) case series design with more than one case reported, (ii) use of cryoablation or radiofrequency ablation, (iii) patients with renal cell carcinoma and, (iv) outcome reported as clinical efficacy.When available, we also quantified the complication rates from each included study.Proportional meta-analysis was performed on both outcomes with a random-effects model. The 95% confidential intervals were also calculated.RESULTSThirty-one case series (20 cryoablation, 11 radiofrequency ablation) met all inclusion criteria.The pooled proportion of clinical efficacy was 89% in cryoablation therapy from a total of 457 cases. There was a statistically significant heterogeneity between these studies showing the inconsistency of clinical and methodological aspects.The pooled proportion of clinical efficacy was 90% in radiofrequency ablation therapy from a total of 426 cases. There was no statistically significant heterogeneity between these studies.There was no statistically significant difference regarding complications rate between cryoablation and radiofrequency ablation.CONCLUSIONSThis review shows that both ablation therapies have similar efficacy and complication rates.There is urgency for performing clinical trials with long-term data to establish which intervention is most suitable for the treatment of small renal masses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

• Aim: Radiofrequency is one of the methods used to treat wrinkles and skin lesions, but its application may result in an abrasive wound. The purpose of this study was to evaluate the effect of collagenase ointment on the epithelial healing of an abrasive wound induced by a radiofrequency system. • Methods: An abrasive wound was produced using radiofrequency at the dorsal midline of 30 guinea pigs, which were randomly divided into 2 groups: one group were treated with saline solution and the other group treated with collagenase ointment; both used twice daily. The animals were sacrificed at 1, 7, 15, 30 and 60 postoperative days. Macroscopic, histological and morphometric evaluations were performed and the results were submitted to statistical analysis. • Results: The animals treated with collagenase ointment presented accelerated healing process and less inflammatory cell infiltration than the saline solution treated animals from one to fifteen postoperative days. Morphometric evaluation showed a thicker epidermis and a thinner dermis layer in the saline solution group at one and seven postoperative days, but significant differences between both groups were not observed at thirty and sixty postoperative days. • Conclusion: According to our results the use of collagenase ointment may accelerate the healing process of a radiofrequency induced abrasive wound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sacroiliac joint (SIJ) pain is responsible for up to 40% of all cases of lumbar back pain. Objective Report the long-term efficacy of radiofrequency denervation for sacroiliac joint pain at six, twelve and eighteen months. Method Third-two adults’ patients with sacroiliac join pain diagnosis were included for a prospective study. Primary outcome measure was pain intensity on the Numeric Rating Scale (NRS). Secondary outcome measure was Patient Global Impression of Change Scale (PGIC). Results Short-term pain relief was observed, with the mean NRS pain score decreasing from 7.7 ± 1.8 at baseline to 2.8 ± 1.2 at one month and to 3.1 ± 1.9 at six months post-procedure (p < 0.001). Long-term pain relief was sustained at twelve and eighteen months post-procedure, with NRS pain remaining at 3.4 ± 2.1 and 4.0 ± 2.7, respectively. Conclusion Radiofrequency denervation of the SIJ can significantly reduce pain in selected patients with sacroiliac syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Object. Over the past few decades, various authors have performed open or stereotactic trigeminal nucleotractotomy for the treatment of neuropathic facial pain resistant to medical treatment. Stereotactic procedures can be performed percutaneously under local anesthesia, allowing intraoperative neurological examination as a method for target refinement. However, blind percutaneous procedures in the region of the atlantooccipital transition carry a considerably high risk of vascular injuries that may bring prohibitive neurological deficit or even death. To avoid such complications, the authors present the first clinical use of microendoscopy to assist percutaneous radiofrequency trigeminal nucleotractotomy. The aim of this article is to demonstrate intradural microendoscopic visualization of the medulla oblongata through an atlantooccipital percutaneous approach. Methods. The authors present a case of severe postherpetic facial neuralgia in a patient who underwent the procedure and had satisfactory results. Stereotactic computational image planning for targeting the spinal trigeminal tract and nucleus in the posterolateral medulla was performed, allowing for an accurate percutaneous approach. immediately before radiofrequency electrode insertion, a tine endoscope was introduced to visualize the structures in the cisterna magna. Results. Microendoscopic visualization offered clear identification of the pial surface of the medulla oblongata and its blood vessels, the arachnoid membrane, cranial nerve rootlets and their entry zone, and larger vessels such as the vertebral arteries and the branches of the posterior inferior cerebellar artery. Conclusions. The initial application of this technique suggests that percutaneous microendoscopy may be useful for particular manipulation of the medulla oblongata, increasing the safety of the procedure and likely improving its effectiveness. (DOI: 10.3171/2011.8.JNS11618)