981 resultados para R wave


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Arterial waves are seen as possible independent mediators of cardiovascular risks, and the wave intensity analysis (WIA) has therefore been proposed as a method for patient selection for ventricular assist device (VAD) implantation. Interpreting measured wave intensity (WI) is challenging and complexity is increased by the implantation of a VAD. The waves generated by the VAD interact with the waves generated by the native heart, and this interaction varies with changing VAD settings. Eight sheep were implanted with a pulsatile VAD (PVAD) through ventriculo-aortic cannulation. The start of PVAD ejection was synchronized to the native R-wave and delayed between 0 % - 90 % of the cardiac cycle in 10 % steps or phase shifts (PS). Pressure and velocity signals were registered, using a combined Doppler and pressure wire positioned in the abdominal aorta, and used to calculate the WI. Depending on the PS, different wave interference phenomena occurred. Maximum unloading of the left ventricle (LV) coincided with constructive interference and maximum blood flow pulsatility, and maximum loading of the LV coincided with destructive interference and minimum blood flow pulsatility. We believe, that non-invasive WIA could potentially be used clinically to assess the mechanical load of the LV, and to monitor the peripheral hemodynamics such as blood flow pulsatility and risk of intestinal bleeding.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND Inferolateral early repolarization (ER) is highly prevalent and is associated with idiopathic ventricular fibrillation (VF). OBJECTIVE The purpose of this study was to evaluate the potential role of T-wave parameters to differentiate between malignant and benign ER. METHODS We compared the ECGs of patients with ER and VF (n = 92) with control subjects with asymptomatic ER (n = 247). We assessed J-wave amplitude, QTc interval, T-wave/R-wave (T/R) ratio in leads II and V5, and presence of low-amplitude T waves (T-wave amplitude <0.1 mV and <10% of R-wave amplitude in lead I, II, or V4-V6). RESULTS Compared to controls, the VF group had longer QTc intervals (388 ms vs 377 ms, P = .001), higher J-wave amplitudes (0.23 mV vs 0.17 mV, P <.001), higher prevalence of low-amplitude T waves (29% vs 3%, P <.001), and lower T/R ratio (0.18 vs 0.30, P <.001). Logistic regression analysis demonstrated that QTc interval (odds ratio [OR] per 10 ms: 1.15, 95% confidence interval [CI} 1.02-1.30), maximal J-wave amplitude (OR per 0.1 mV: 1.68, 95% CI 1.23-2.31), lower T/R ratio (OR per 0.1 unit: 0.62, 95% CI 0.47-0.81), presence of low-amplitude T waves (OR 3.53, 95% CI 1.26-9.88). and presence of J waves in the inferior leads (OR 2.58, 95% CI 1.18-5.65) were associated with malignant ER. CONCLUSION Patients with malignant ER have a higher prevalence of low-amplitude T waves, lower T/R ratio (lead II or V5), and longer QTc interval. The combination of these parameters with J-wave amplitude and distribution of J waves may allow for improved identification of malignant ER.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to determine whether children with potential developmental coordination disorder (p-DCD) demonstrate increased arterial stiffness and thickness compared to age and school matched controls (mean age 14.7 yrs). We also assessed whether these measures differed by sex. Compliance, distensibility, and intima-media thickness (IMT) were measured at the common carotid artery for 28 children with p-DCD and 47 controls. ECG-R-wave-toe pulse wave velocity (PWV) was also measured for 29 children with p-DCD and 45 controls. We found that compared to controls males with p-DCD had significantly higher PWV (3.8±0.2 vs. 4.1±0.3, p=0.001) and lower distensibility (0.82± 0.19 vs. 0.70± 0.17, p=0.034) while females showed no significant differences (p=0.523 and p=0.123 respectively). As a result, it is apparent that sex differences exist with respect to arterial health within this population and that children with p-DCD may be more likely to develop cardiovascular disease later in life.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Avaliaram-se os efeitos da hipovolemia aguda em cães anestesiados pelo isofluorano sobre a eletrocardiografia com a duração e amplitude da onda P (Pms e PmV, respectivamente); intervalo entre as ondas P e R (P-R); duração do complexo QRS (QRS); amplitude da onda R (RmV); intervalo entre as ondas Q e T (Q-T) e intervalo entre as duas ondas (R-R), freqüência cardíaca (FC), índice cardíaco (IC), índice sistólico (IS) e pressões arteriais sistólica (PAS), diastólica (PAD) e média (PAM). Verificou-se também a possível influência do anestésico sobre a resposta compensatória à hipovolemia aguda. Para tal, foram utilizados 20 cães hígidos, sem raça definida, adultos, machos e fêmeas. Induziu-se a anestesia geral com isofluorano por meio de máscara naso-oral a 2,5 CAM e, após a intubação orotraqueal, o vaporizador foi ajustado em 1,5 CAM. Induziu-se a hipovolemia nos animais retirando-se volume total de 35 mlkg-1 de sangue. As mensurações foram realizadas antes da hipovolemia (M0), imediatamente após a retirada do volume total de sangue calculado (M1), e aos dez (M2), trinta (M3) e sessenta (M4) minutos. A avaliação estatística das variáveis foi efetuada por meio de Análise de Variância (ANOVA), seguida pelo teste de Tukey, considerando nível de significância de 5% (P<0,05). Houve redução do tempo de condução elétrica átrio-ventricular, aumento da impedância da musculatura ventricular, redução da freqüência cardíaca, dos índices cardíacos e sistólico, porém sem alteração na despolarização ventricular, sendo que o isofluorano não influenciou no desencadeamento da resposta compensatória à hipovolemia aguda.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The electrocardiographic effects of dobutamine stress testing (10 to 40 mu g/kg/minute) were investigated in five conscious healthy dogs. We studied the changes in the duration and amplitude of P wave, PR interval, duration of QRS complex, R wave amplitude, QT interval, and heart rate. Development of arrhythmias and ST segment abnormalities were also recorded. It was observed that dobutamine significantly affects atrioventricular-nodal conduction and total electrical systole time at higher infusion rates. Only a single episode of sustained ventricular tachycardia was observed, which was promptly restored to sinus rhythm shortly after dobutamine infusion was discontinued. No ST segment abnormalities were detected. Dobutamine stress testing was concluded to play a role in some ECG parameters at higher infusion rates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Further knowledge of feline physiology and neonatology is needed because the number of cats being kept as pets and used as experimental animals has increased. Few studies have been published on feline sequential electrocardiography. This study was conducted to determine the values of normal waves, complexes, and intervals of the electrocardiogram in clinically healthy feline neonates. Serial electrocardiography was performed in 15 female and 15 male neonates at 30 days of age. Parameters analyzed were heart rate and rhythm, duration and amplitude of electrocardiographic waves, duration of intervals, and the electrical axis of the heart. The results did not show differences between males and females. During the neonates' first 30 days of life, migration of the electrical axis from right to left was observed. There was a progressive increase in the R wave amplitude, while the S wave amplitude showed a progressive decrease. A sinus heart rhythm was predominant in the feline neonates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective - To evaluate diagnostic testing that could be used to establish an early diagnosis of cardiotoxicosis induced by long-term administration of doxorubicin. Animals - 13 adult mixed-breed dogs. Procedures - 7 dogs were administered doxorubicin chloride (30 mg/m2, IV, q 21 d for 168 days [cumulative dose, 240 mg/m2]), and 6 dogs received saline (0.9% NaCl) solution (5 mL, IV, q 21 d for 168 days; control group). Echocardiography, ECG, arterial blood pressure, plasma renin activity (PRA), and plasma concentrations of norepinephrine and brain natriuretic peptide (BNP) were assessed before each subsequent administration of doxorubicin and saline solution. Results - Dogs that received doxorubicin had a significant decrease in R-wave amplitude, compared with values for the control group, from 30 to 210 mg/m2. Doxorubicin-treated dogs had decreases in fractional shortening and left ventricular ejection fraction evident as early as 30 mg/m2, but significant differences between groups were not detected until 90 mg/m2 was reached. There was also a significant increase in PRA (≥ 120 mg/m2) and left ventricular end-systolic and end-diastolic dimensions (≥ 60 and ≥ 180 mg/m2, respectively). Systemic arterial pressure, remaining echocardiographic variables, and concentrations of norepinephrine and BNP had significant variations, but of no clinical importance, during doxorubicin administration. Conclusions and clinical relevance - Doxorubicin-induced cardiotoxicosis developed at 120 mg/m2, but there were no clinical signs of dilated cardiomyopathy or congestive heart failure. Echocardiography and determination of PRA were able to detect early cardiac alterations during the development of dilated cardiomyopathy, despite apparently differing degrees of sensitivity to development of doxorubicin-induced cardiotoxicosis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this work was to evaluate the electrocardiography effects (ECG), sedation time and quality of recovery due to buprenorphine (G1) and butorphanol (G2) administration in dogs pretreated with acepromazine. Seven adult dogs were submitted to both protocols, with a thirty days interval between groups. G1 animals were premedicated with acepromazine (0.1 mg/kg) followed 10 minutes later with buprenorphine (0.005 mg/kg), both applied intravenously. The same procedure was performed for G2 employing butorphanol (0.3 mg/kg) instead of buprenorphine. The measurements of the variables heart rate (HR), duration and amplitude of P wave, P-R intervals (PR), QRS complex duration, R wave amplitude, Q-T intervals (QT) and R-R intervals (RR) were taken immediately before application of acepromazine (M0), 10 minute after administration of acepromazine (M10) and 10 minutes after opioids administration (M20). Serial measurements were carried out in 10 minute intervals after the administration of butorphanol or buprenorphine up to 60 minutes. Numeric data were submitted to Tukey Analysis (p < 0.05). The amplitude of P wave decreased 30 minutes after the administration of the butorphanol. Sedation time was longer in G1 (78 minutes) than G2 (72 minutes) and recovery was good in both groups. These results indicate that butorphanol or buprenorphine produced discreet alterations on ECG, which don´t contraindicate its clinical use.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Current pulsatile ventricular assist devices operate asynchronous with the left ventricle in fixed-rate or fill-to-empty modes because electrocardiogram-triggered modes have been abandoned. We hypothesize that varying the ejection delay in the synchronized mode yields more precise control of hemodynamics and left ventricular loading. This allows for a refined management that may be clinically beneficial. METHODS: Eight sheep received a Thoratec paracorporeal ventricular assist device (Thoratec Corp, Pleasanton, Calif) via ventriculo-aortic cannulation. Left ventricular pressure and volume, aortic pressure, pulmonary flow, pump chamber pressure, and pump inflow and outflow were recorded. The pump was driven by a clinical pneumatic drive unit (Medos Medizintechnik AG, Stolberg, Germany) synchronously with the native R-wave. The start of pump ejection was delayed between 0% and 100% of the cardiac period in 10% increments. For each of these delays, hemodynamic variables were compared with baseline data using paired t tests. RESULTS: The location of the minimum of stroke work was observed at a delay of 10% (soon after aortic valve opening), resulting in a median of 43% reduction in stroke work compared with baseline. Maximum stroke work occurred at a median delay of 70% with a median stroke work increase of 11% above baseline. Left ventricular volume unloading expressed by end-diastolic volume was most pronounced for copulsation (delay 0%). CONCLUSIONS: The timing of pump ejection in synchronized mode yields control over left ventricular energetics and can be a method to achieve gradual reloading of a recoverable left ventricle. The traditionally suggested counterpulsation is not optimal in ventriculo-aortic cannulation when maximum unloading is desired.