969 resultados para Quantitative-analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to determine the range of Australian perceptions on new venture creation at the end of the decade of the 1980s, and in particular attitudes towards government involvement in fostering entrepreneurship, a major quantitative study was conducted. The survey involved more than 1500 Australians in face-to-face interviews (300 in each mainland capital city) chosen on a random basis.

An analysis of the data provides an assessment of the Australian general public&s perceptions in three key areas: their understanding of the word 'entrepreneur' their rating of importance of new venture creation; their belief in government involvement in fostering new venture creation.

It is believed to be the first study attempting to quantify an entire nation&s perceptions in three areas vital to creators of national economic and industry policies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a column packed with fully porous particles, four methods for controlling the flow rates at which gradient elution runs are conducted in very high pressure liquid chromatography (VHPLC) were tested to determine whether reproducible thermal conditions could be achieved, such that subsequent analyses would proceed at nearly the same initial temperature. In VHPLC high flow rates are achieved, producing fast analyses but requiring high inlet pressures. The combination of high flow rates and high inlet pressures generates local heat, leading to temperature changes in the column. Usually in this case a post-run time is input into the analytical method to allow the return of the column temperature to its initial state. An alternative strategy involves operating the column without a post-run equilibration period and maintaining constant temperature variations for subsequent analysis after conducting one or a few separations to bring the column to a reproducible starting temperature. A liquid chromatography instrument equipped with a pressure controller was used to perform constant pressure and constant flow rate VHPLC separations. Six replicate gradient separations of a nine component mixture consisting of acetophenone, propiophenone, butyrophenone, valerophenone, hexanophenone, heptanophenone, octanophenone, benzophenone, and acetanilide dissolved in water/acetonitrile (65:35, v/v) were performed under various experimental conditions: constant flow rate, two sets of constant pressure, and constant pressure operation with a programmed flow rate. The relative standard deviations of the response factors for all the analytes are lower than 5% across the methods. Programming the flow rate to maintain a fairly constant pressure instead of using instrument controlled constant pressure improves the reproducibility of the retention times by a factor of 5, when plotting the chromatograms in time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the tumor response to neoadjuvant chemotherapy, Tc-99m-sestamibi breast scintigraphy was proposed as a quantitative method Fifty-five patients with ductal carcinoma were studied They underwent breast scintigraphy before and after neoadjuvant chemotherapy, along with clinical assessment and surgical specimen analysis The regions of interest on the lesion and contralateral breast were identified, and the pixel counts were used to evaluate lesion uptake in relation to background radiation The ratio of these counts before to after neoadjuvant chemotherapy was assessed The decrease in uptake rate due to chemotherapy characterized the scintigraphy tumor response The Kruskal-Wallis test was used to compare the mean scintigraphic tumor response and histological type Dunn's multiple comparison test was used to detect differences between histological types The Mann-Whitney test was used to compare means between quantitative and qualitative variables scintigraphic tumor response vs clinical response and uptake before chemotherapy vs scintigraphic tumor response The Spearman's test was used to correlate the quantitative variables of clinical reduction in tumor size and scintigraphic tumor response All of the variables compared presented significant differences The change in Tc-99m-sestamibi uptake noted on breast scintigraphy, before to after neoadjuvant chemotherapy, may be used as an effective method for evaluating the response to neoadjuvant chemotherapy, since this quantification reflects the biological behavior of the tumor towards the chemotherapy regimen Furthermore, additional analysis on the uptake rate before chemotherapy may accurately predict treatment response

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaluate the distribution and variation of placental vascular indices according to gestational age and placental volume. From March to November 2007, three-dimensional (3D)-power Doppler ultrasound was performed in 295 normal pregnancies from 12 to 40 weeks of gestation. Using the same preestablished settings for all patients, power Doppler was applied to the placenta and placental Volume was obtained by the rotational technique (VOCAL(TM)). The 3D-power histogram was used to determine the placental vascular indices: vascularization index (VI), flow index (FI) and vascularization-flow index (VFI). The placental vascular indices were then plotted against gestational age and placental volume. All placental vascular indices showed constant distribution throughout gestation. A tendency for a reduction in placental vascular indices with increased placental volume was observed, but was only statistically significant when placental FI was considered (p < 0.05). All placental vascular indices estimated by 3D-power Doppler ultrasonography presented constant distribution throughout gestation, despite the increase in placental volume according to gestational age. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several factors render carotenoid determination inherently difficult. Thus, in spite of advances in analytical instrumentation, discrepancies in quantitative results on carotenoids can be encountered in the international literature. A good part of the errors comes from the pre-chromatographic steps such as sampling scheme that does not yield samples representative of the food lots under investigation; sample preparation which does not maintain representativity and guarantee homogeneity of the analytical sample; incomplete extraction; physical losses of carotenoids during the various steps, especially during partition or washing and by adsorption to glass walls of containers; isomerization and oxidation of carotenoids during analysis. on the otherhand, although currently considered the method of choice for carotenoids, high performance liquid chromatography (HPLC) is subject to various sources of errors, such as: incompatibility of the injection solvent and the mobile phase, resulting in distorted or split peaks; erroneous identification; unavailability, impurity and instability of carotenoid standards; quantification of highly overlapping peaks; low recovery from the HPLC column; errors in the preparation of standard solutions and in the calibration procedure; calculation errors. Illustrations of the possible errors in the quantification of carotenoids by HPLC are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aqueous infusions of Brazilian Maytenus leaves are used as beverages, foodstuffs, and phytomedicines. Previously, we isolated two new flavonoid tetrasaccharides from the infusion of Maytenus aquifolium leaves that showed antiulcer activity. In this investigation a new flavonoid tetrasaccharide, kaempferol-3-O-alpha -L-rhamnopyranosyl (1-6)-O-[alpha -L-arabinopyranosyl (1 -->3)-O-alpha -L-rhamnopyranosyl (1-2)]-O-beta -D-galactopyranoside (3), was isolated, together with kaempferol tri- and disaccharides and quercetin trisaccharides from the aqueous infusion of Maytenus ilicifolia leaves. All structures were elucidated by ES-MS and NMR spectroscopic methods. The quantitative analysis of the flavonoid glycosides from Maytenus ilicifolia and M. aquifolium has been performed by HPLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new approach for studying photorefractive gratings in two-wave mixing experiments by a phase modulation technique is presented. The introduction of a large-amplitude, high-frequency sinusoidal phase modulation in one of the input beams blurs the interference pattern and provides powerful harmonic signals for accurate measurements of the grating diffraction efficiency eta and the output phase shift rho between the transmitted and diffracted waves. The blurring of the light fringes can be used to suppress the higher spatial harmonics of the grating, allowing a space-charge field with sinusoidal profile to be recorded. Although the presence of such a strong phase modulation affects the beam coupling in a rather complicated way, it is shown that for the special case of equal intensity input beams, the effect of the phase modulation on eta and rho is reduced to a weakening of the coupling strength. The potentialities of the technique are illustrated in a study of refractive-index waves excited by running interference patterns in a Bi12TiO20 crystal. Expressions for the diffraction efficiency and the output phase shift are derived and used to match numerically calculated curves to the experimental data. The theoretical model is supported by the very good data fitting and allows the computation of important material parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluates laboratory microtomography and microhardness analysis for quantifying the mineral content of bovine enamel. Fifty enamel blocks were submitted individually for 5 days to a pH-cycling model at 37 degrees C and remained in the remineralizing solution for 2 days. The blocks were treated twice daily for 1 min with NaF dentifrices (Placebo, 275, 550, 1,100 mu g F/g and Crest (R)) diluted in deionized water. Surface microhardness changes (%SMH) and mineral loss (Delta Z) were then calculated. Laboratory microtomography was also used to measure total mineral lost (LMM). Pearson's correlation (p < 0.05) was used to determine the relationship between different methods of analysis and dose-response between treatments. Dentifrice fluoride concentration and %SMH and Delta Z were correlated (p < 0.05). There was a positive relationship (p < 0.05) when comparing LMM vs. Delta Z; a negative relationship (p < 0.05) was found for %SMH vs. LMM and %SMH vs. Delta Z. Therefore, both mineral quantification techniques provide adequate precision for studying the bovine enamel-pH-cycling demineralization/remineralization model.