965 resultados para Postos de combustíveis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A modeling of criterias and alternatives is through and applied a questionnaire based on method AHP to proprietors of gas stations. The considered alternatives had been the maintenance of the current state with electric energy of the deliverer and the generation in small scale based on the natural gas. The used criteria had been Cost of the Investment, Final Cost of the Energy, Operational cost, Ambient Benefits, Risk and Variation of Costs. The study it was carried through in the city of Natal, RN in ranks that make use of the natural as for resale, where the generation alternative on the basis of the available gas is present. The main results evidence in a dimension the viability of use of method AHP with questionnaire by means of validation of the judgments with analysis of variance beyond proper the normal mechanisms of analysis of consistency to the method. The main results of the analysis help to show that in this in case that the profile of models of criteria and judgments of the actors is similar, with the final evidence of that it has a dominance of the maintenance of the energy of the deliverer. The main criterion to influence this decision was the risk

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work was to investigate the factors that inhibit the use of Environmental Techniques in the Gas Station of the city of Natal/RN. For this, a survey with the aid of a questionnaire was used like research instrument. It s used a sample for convenience, not probabilistic. For collection of the data, it was used directly application of the questionnaire to the Managers or Assistant managers of the gas station, in accordance with its availability or presence. The data was collected in all the regions of Natal (North, South, East and West). The population in accordance with the data of the ANP of September 2005 is of 111 ranks and the collected sample was of 86. To carry through the analysis of the data of this research had been used softwares Excel and Statistic version 5.0, for Windows. The analysis of data is divided in two parts; descriptive analysis and analysis of groupings (clusters). The results showed that bigger part of the interviewed ones has between 30 and 39 years of age; they have second grade completed; they had declared to have little between and reasonable knowledge how much to the use of Clean Technology (CT) in gas station; and a small part of the interviewed ones had informed to have much knowledge how much the resolutions of the CONAMA established for the Gas Station. Of the searched ranks, the majority is national(76.7%); the most accurate practice environmental used in the gas station are: it collects selective of oil used or contaminated and ecological tanks - coated with strengthened fibre glass; great part of the interviewed ones (33.8%) informed that never the TL makes planning of referring future action; about of the half of the interviewed ones (84.9%) they had more declared that its employees have of none to a reasonable level of training for deal with problems that compromise the environment; the majority of the ranks (72.1%) functions has for more then six years. It is observed that almost all the interviewed ones (96.5%) evaluate as being important or very important the implantation of CT in Gas Station and the great majority (82.1%) evaluates the difficulty in if implanting these technologies in Gas Station as being easy or very easy. In the analysis of cluster, it was verified existence of two groupings (as much in the variable of the barriers and benefits), being that inside of each clusters exists homogeneity and between clusters exists heterogeneity. In reality, everything is important or very important in the opinion of the interviewed ones. There only exists a small significant difference that separates them in clusters

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The customer loyalty became strategy factor for the sustainability of business enterprises. And will be them competitive is important to describe the factors than the consumers consider for to choose the business than will buy the product or service. The dissertation objective is to know the factors that influence the consumer s satisfaction and loyalty in gas stations of Natal/RN, using the index national of customer satisfaction. The literature review was directed for strategy concepts, service quality, satisfaction and fidelity consumer and index national of customer satisfaction. The method used was descriptive-explicative, with application of a survey, from march 15 until april 15 of 2013, with 391 consumers of gas station. In relational analysis, we considered eight constructs: quality, price, complaints, satisfaction, image, loyalty, affection and commitment calculated. For customer satisfaction, the factors that influence have resulted in fuel quality, technical skills of vendors and duration of service. For customer loyalty, the factors that influence resulted in: image, feeling for distributor flag post, location and overall satisfaction with the gas station

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The contamination of underground waters is a subject of great importance, since a lot of people use this kind of source for public supply. This paperwork manages with how gas stations can contaminate these waters and what are some remediation techniques, used nowadays to solve this problem. The contamination caused by the gas stations can have its origin in the underground storage tanks when they suffer corrosion and show leaking problems. It’s a topic of great relevance, because the hydrocarbons derivated from petroleum present in the fuels can stay for a long time in the environment. Besides that, an analyses of the risk of contamination by gas stations in the city of Rio Claro was made based on three parameters: density of the gas stations, depth of the underground water and hydraulic conductivity. To achieve such goal, maps were elaborated considering those parameters individually and considering the three of them together. Analyzing those maps, it was concluded see that the spots that represent the biggest risks of contamination in Rio Claro are located southeast and center-west.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Leaking of hydrocarbon in fuel underground storage tanks constitute object of concern for urban environmental management, because therefore they provoke damages to the physical, biological and socioeconomic environment. Though laws that regulate this essential activity exist, aiming at to prevent contamination with hydrocarbon, we observe that this still happens. This fact evidences that the selection of places for installation of gas stations has not considered the characteristics of the natural environment, implying in more critical consequences associated to the leaking. The objective of this work is to elaborate a chart applied to the gas stations in Rio Claro/SP. The determination of the Index of Environmental Sensitivity for elaboration of such chart was carried through breaking the selection of factors of Environmental Sensitivity of physical, biological and socioeconomic environment. The balance of these factors was given by means of Ad hoc consultation. The crossing of the information was carried through using the method of overlapping of overlays. The result is a chart that shows us areas with classes of high, middle and low Environmental Sensitivity. One gives credit that this type of material can be used as criterion in the selection of adjusted areas for installations of new gas stations and management of the already installed gas stations. The diagnosis of the current situation of the gas stations in the area and recommendations had also been elaborated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The retail fuel stations are partially or potentially polluters and generators of environmental accidents, potentially causing contamination of underground and surface water bodies, soil and air. Leaks in fuel retail stations´ underground storage systems are often detected in Brazil and around the world. Monoaromatic hydrocarbons, BTEX (benzene, toluene, ethylbenzene and xylenes) and polycyclic aromatic hydrocarbons (PAHs) are an indication of the presence of contamination due to its high toxicity. This paper presents a case study of contamination in a Fuel Retail Station by petroleum derivative products in the city of Natal. For identification and quantification of the hydrocarbons, EPA analytical methods were used. The values of benzene quantified by EPA method 8021b CG-PID/FID, ranged from 1.164 to 4.503 mg.Kg-1 in soil samples, and from 12.10 to 27,639 μg.L-1 in underground water samples. Among the PAHs, naphthalene and anthracene showed the most significant results in soil samples, 0.420 to 15.46 mg.Kg-1 and 0.110 to 0,970 mg.Kg-1, respectively. In underground water samples, the results for Naphthalene varied between 0.759 and 614.7 μg.L-1. PAHs were quantified by EPA Method 8270 for GCMS. All of the results for the chemical analysis were compared with the values for the CONAMA 420/2009 resolution. The results for benzene (27,639 μg.L-1) showed levels highly above the recommended by the CONAMA 420 resolution, wherein the maximum permissible for underground water is 5 μg.L-1. This is a worrying factor, since underground water makes up 70% of the city of Natal´s water supply

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The retail fuel stations are partially or potentially polluters and generators of environmental accidents, potentially causing contamination of underground and surface water bodies, soil and air. Leaks in fuel retail stations´ underground storage systems are often detected in Brazil and around the world. Monoaromatic hydrocarbons, BTEX (benzene, toluene, ethylbenzene and xylenes) and polycyclic aromatic hydrocarbons (PAHs) are an indication of the presence of contamination due to its high toxicity. This paper presents a case study of contamination in a Fuel Retail Station by petroleum derivative products in the city of Natal. For identification and quantification of the hydrocarbons, EPA analytical methods were used. The values of benzene quantified by EPA method 8021b CG-PID/FID, ranged from 1.164 to 4.503 mg.Kg-1 in soil samples, and from 12.10 to 27,639 μg.L-1 in underground water samples. Among the PAHs, naphthalene and anthracene showed the most significant results in soil samples, 0.420 to 15.46 mg.Kg-1 and 0.110 to 0,970 mg.Kg-1, respectively. In underground water samples, the results for Naphthalene varied between 0.759 and 614.7 μg.L-1. PAHs were quantified by EPA Method 8270 for GCMS. All of the results for the chemical analysis were compared with the values for the CONAMA 420/2009 resolution. The results for benzene (27,639 μg.L-1) showed levels highly above the recommended by the CONAMA 420 resolution, wherein the maximum permissible for underground water is 5 μg.L-1. This is a worrying factor, since underground water makes up 70% of the city of Natal´s water supply

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Alguns cientistas ambientais prevêem que a poluição dos solos será um dos maiores legados com grandes impactos para as gerações futuras, pois atualmente ainda existe desconhecimento das fontes poluidoras e da sua extensão. O Brasil, devido a sua extensão territorial, suas bacias hidrográficas, número de postos de abastecimentos e controles ambientais ainda ineficazes, está muito exposto a esse tipo de poluição. Atualmente, há no Brasil mais de 34.300 postos de combustíveis, com volume de 65.000.000 m3 de gasolina e diesel consumidos anualmente, conforme dados da Agência Nacional do Petróleo Gás Natural e Biocombustíveis , ANP, em 2008. Sendo assim, a exposição e contaminação dos solos e dos lençóis freáticos com constituintes aromáticos do diesel e gasolina torna-se um sério problema ambiental. Dentro deste grupo, encontram-se o benzeno, tolueno, xileno, conhecido como BTEX e os hidrocarbonetos policíclicos aromáticos, conhecido como PAH. Este trabalho tem como objetivo estudar a remediação in-situ de um posto de combustíveis na região do ABC Paulista, no Estado de São Paulo. Aplicando-se a técnica de Processo Oxidativo Avançado via reagente de Fenton (H2O2 + Fe2+ → Fe3+ + OH- + OH . ), o radical hidroxila gerado mineraliza compostos aromáticos, decompondo-os definitivamente. Amostras de água do posto em estudo apresentavam elevados teores de BTEX e PAH, 2,58 mg.L-1 e 0,298 mg.L-1 respectivamente, estando em níveis não tolerados pelo órgão ambiental paulista CETESB sendo necessária a intervenção para tratamento da área. Com os níveis de poluentes e o perfil hidrogeológico identificados, a remediação foi iniciada com injeções no solo de peróxido de hidrogênio a 8%v.v, FeSO4 a 0,40 mg.L-1 e solução à base de NPK (nitrogênio, fósforo e nitrogênio) a 100 mg.L-1 como nutrientes para os microorganismos do solo. Estes valores são provenientes de experimentos anteriores e tratamentos já realizados. Foram conduzidas campanhas de injeção trimestrais com 100 litros desta solução completa como reagente , e medições trimestrais de BTEX, PAH e outros parâmetros de controle, que foram indicando o sucesso do tratamento. Após 18 meses o local foi considerado tratado pelo órgão ambiental, onde monitoramentos semestrais estão em continuidade para garantir o resultado do tratamento e das ações corretivas. Assim, o estudo real da remediação de solos contaminados com os poluentes orgânicos via processo de Fenton, com concentração de H2O2 a 8%v/v, e FeSO4 a 0,40 mg.L-1 demonstrou-se uma técnica de sucesso. O entendimento dos resultados da remediação, mesmo sujeitos aos fenômenos naturais, como intempéries e chuvas, é uma experiência grande, pois por mais reais que simulações em laboratório possam ser, é muito difícil incluir nestes sistemas, as variações que um tratamento real está exposto