970 resultados para Pipe Insulation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pipe insulation between the collector and storage tank on pumped storage (commonly called split), solar water heaters can be subject to high temperatures, with a maximum equal to the collector stagnation temperature. The frequency of occurrence of these temperatures is dependent on many factors including climate, hot water demand, system size and efficiency. This paper outlines the findings of a computer modelling study to quantify the frequency of occurrence of pipe temperatures of 80 degrees Celsius or greater at the outlet of the collectors for these systems. This study will help insulation suppliers determine the suitability of their materials for this application. The TRNSYS program was used to model the performance of a common size of domestic split solar system, using both flat plate and evacuated tube, selective surface collectors. Each system was modelled at a representative city in each of the 6 climate zones for Australia and New Zealand, according to AS/NZS4234 - Heat Water Systems - Calculation of energy consumption, and the ORER RECs calculation method. TRNSYS was used to predict the frequency of occurrence of the temperatures that the pipe insulation would be exposed to over an average year, for hot water consumption patterns specified in AS/NZS4234, and for worst case conditions in each of the climate zones. The results show; * For selectively surfaced, flat plate collectors in the hottest location (Alice Sprints) with a medium size hot water demand according to AS/NZS2434, the annual frequency of occurrence of temperatures at and above 80 degrees Celsius was 33 hours. The frequency of temperatures at and above 140 degrees Celsius was insignificant. * For evacuated tube collectors in the hottest location (Alice Springs), the annual frequency of temperatures at and above 80 degrees Celsius was 50 hours. Temperatures at and above 140 degrees Celsius were significant and were estimated to occur for more than 21 hours per year in this climate zone. Even in Melbourne, temperatures at and above 80 degrees can occur for 12 hours per year and at and above 140 degrees for 5 hours per year. * The worst case identified was for evacuated tube collectors in Alice Springs, with mostly afternoon loads in January. Under these conditions, the frequency of temperatures at and above 80 degrees Celsius was 10 hours for this month only. Temperatures at and above 140 degrees Celsius were predicted to occur for 5 hours in January.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Appropriate pipe insulation on domestic, pumped storage (split), solar water heating systems forms an integral part of energy conservation measures of well engineered systems. However, its importance over the life of the system is often overlooked. This study outlines the findings of computer modelling to quantify the energy and cost savings by using pipe insulation between the collector and storage tank. System sizes of 270 Litre storage tank, together with either selectively surfaced, flat plate collectors (4m2 area), or 30 evacuated tube collectors, were used. Insulation thicknesses of 13mm and 15mm, pipe runs both ways of 10, 15 and 20 metres and both electric and gas boosting of systems were all considered. The TRNSYS program was used to model the system performance at a representative city in each of the 6 climate zones for Australia and New Zealand, according to AS/NZS4234 – Heat Water Systems – Calculation of energy consumption and the ORER RECs calculation method. The results show:  Energy savings from pipe insulation are very significant, even in mild climates such as Rockhampton. Across all climates zones, savings ranged from 0.16 to 3.5GJ per system per year, or about 2 to 23 percent of the annual load.  There is very little advantage in increasing the insulation thickness from 13 to 15mm. For electricity at 19c/kWh and gas at 2 c/MJ, cost savings of between $27 and $100 per year are achieved across the climate zones. Both energy and cost savings would increase in colder climates with increased system size, solar contribution and water temperatures.  The pipe insulation substantially improves the solar contribution (or fraction) and Renewable Energy Certificates (RECs), as well as giving small savings in circulating pump running costs in milder climates. Solar contribution increased by up to 23 percent points and RECs by over 7 in some cases.  The study highlights the need to install and maintain the integrity of appropriate pipe insulation on solar water heaters over their life time in Australia and New Zealand.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An external pipe-crawling device presented in this paper aids the inspection of pipes in hazardous environments and areas inaccessible to humans. The principal component of our design, which uses inchworm type motion, is a compliant ring mechanism actuated using shape memory alloy (SMA) wire. It was fabricated and tested and was reported in our earlier work. But this device had a drawback of low crawling speed (about 1 mm/min) owing to the delay in heating and cooling of the SMA strips in the linear actuation. Additionally, that design also had the difficulties of mounting on pipes with closed ends, large radial span, and the need for housing for electrical insulation and guiding of the SMA wire. In this paper we present a compact design that overcomes the difficulties of the earlier design. In particular, we present a compact compliant mechanism with two halves so as to enable mounting and un-mounting on any closed or open pipe. Another feature is the presence of insulation and guiding of the SMA wire without housing. This design results in a reduction of the radial span of the ring from 22 mm to 12 mm, and the stiffness of the mechanism and the SMA wire are matched. An SMA helical spring is to used in the place of an SMA strip to increase the crawling speed of the device. A microcontroller-based circuitry is also fitted to cyclically.activate the SMA wires and springs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the measurements of strain and the subsequent stress analysis on an in-service cast iron water main buried in reactive soil. The results indicate that the pipe crown experienced predominantly tensile stresses during drying in summer and, subsequently, these stresses reduce, eventually leading to compressive stresses as the soil swells with increase in moisture content with the approach of winter. It is also evident that flexural movement caused by thermal stresses and soil pressure has led to downward bending of the pipe in summer and subsequent upward movement in winter. The limited data collected from pipe strains and strengths indicate that it is possible for pipe capacity to be exceeded by thermal and soil stresses leading to pipe failure, provided the pipe has undergone significant corrosion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The loss of valuable water resources due to pipe failure has become a major problem in Australia, especially in areas under high level of water restrictions. Generally pipe failure occurs due to a combination of physical and environmental factors. Stresses induced by shrinking and swelling of reactive soils are one of the major factors affecting the performance of buried pipes. This paper presents the details of a field instrumentation undertaken to monitor the performance of an in-service water reticulation pipe buried in a reactive soil and subjected to seasonal climatic changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Building insulation is often used to reduce the conduction heat transfer through building envelope. With a higher level of insulation (or a greater R-value), the less the conduction heat would transfer through building envelope. In this paper, using building computer simulation techniques, the effects of building insulation levels on the thermal and energy performance of a sample air-conditioned office building in Australia are studied. It is found that depending on the types of buildings and the climates of buildings located, increasing the level of building insulation will not always bring benefits in energy saving and thermal comfort, particularly for internal-load dominated office buildings located in temperate/tropical climates. The possible implication of building insulation in face of global warming has also been examined. Compared with the influence of insulation on building thermal performance, the influence on building energy use is relatively small.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Failure of buried pipes due to reactive soil movement (e.g. shrinking/swelling) is a common problem for water and gas pipe networks in Australia and the world. Soil movement is closely related to seasonal climatic change, and particularly to the moisture content of soil. Although some research has been carried out to understand the effect of freezing and thawing of soils and temperature effects in colder climates, very limited research has been undertaken to examine the possible failure mechanisms of pipes buried in reactive soils. This study reports the responses of a 2 m long polyethylene pipe buried in reactive clay in a box under laboratory conditions. The soil and pipe movements were measured as the soil was wetted from the bottom of the box. It was observed that the pipe underwent substantial deformation as the soil swelled with increase of the moisture content. The results are explained with a simplified numerical analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Response to discussion on Gallage CPK, Chan D and Kodilara J (2012) Response of a plastic pipe buried in expansive clay. Proceedings of ICE, Geotechnical Engineering, Vol 164, February 2012, Issue GE1, pages 45-57.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hong Kong is a densely populated city suffering badly from the urban heat island effect. Green wall offers a means of ameliorating the situation but there are doubts over its suitability in Hong Kong’s unique environment. In this paper, we look at the potential for green walls in Hong Kong first by summarising some of the Chinese green walling systems and associated vegetation in use, then by an introduction to three existing green walls in Hong Kong, and finally through a small experiment aimed at identifying the likely main effects of green walled housing. The results indicate that green walling in Hong Kong is likely to provide enhanced internal house environment in terms of warm weather temperature reduction, stabilisation and damping, with direct energy savings in air-conditioning and indirect district benefits of reduced heat island effect and carbon emissions. The green walling insulation properties also suggest the possibility of warmer homes in winter and/or energy savings in mechanical heating provision.