88 resultados para Perimetry


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To use preferential hyperacuity perimetry to obtain a quantitative measure of central visual field distortion that would aid in the monitoring of functional responsiveness to ranibizumab treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To evaluate the diagnostic capability of tendency oriented perimetry (TOP) in glaucoma. METHODS. A): The diagnostic accuracy of mean defect (MD), square-root of the loss variance (sLV), and number of pathologic points (NPP) was calculated in 295 normal and 414 glaucoma eyes (179 early, 112 moderate, and 123 advanced) examined with TOP. B): Threshold fluctuation (F) and its relationship with the loss variance (LV) was measured in 34 normal and 33 glaucoma eyes (mean MD=3 dB; SD=3.9) for TOP and for full-threshold perimetry (FT). C): Twenty-eight eyes with stable glaucoma (mean MD=9.5 dB; SD=7.2) were examined six times to quantify LV error. D): TOP and FT were tested with the simulation program PeriSim using different behavior models. RESULTS. A): The best diagnostic index in early glaucoma (MD

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effect of cataract extraction on Swedish Interactive Thresholding Algorithm (SITA) perimetry in patients with coexisting cataract and glaucoma. PATIENTS AND METHODS: This is a retrospective noncomparative interventional study. Thirty-seven consecutive patients with open-angle glaucoma who had cataract extraction alone or combined with trabeculectomy were included. All patients had SITA-standard 24-2 visual fields before and after the surgery. The main outcome measures were changes in mean deviation (MD) and pattern standard deviation (PSD). Additionally, changes in best-corrected visual acuity, intraocular pressure, and number of glaucoma medications were also studied. RESULTS: Visual field tests were performed 3.9±4.4 months before surgery and 4.1±2.8 months after surgery. Mean visual acuity improved after the surgery, from 0.41±0.21 to 0.88±0.32 (P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sensitivity and specificity of the screening mode of the Humphrey-Welch Allyn frequency-doubling technology (FDT), Octopus tendency-oriented perimetry (TOP), and the Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast (HSF) in patients with glaucoma. DESIGN: A comparative consecutive case series. METHODS: This was a prospective study which took place in the glaucoma unit of an academic department of ophthalmology. One eye of 70 consecutive glaucoma patients and 28 age-matched normal subjects was studied. Eyes were examined with the program C-20 of FDT, G1-TOP, and 24-2 HSF in one visit and in random order. The gold standard for glaucoma was presence of a typical glaucomatous optic disk appearance on stereoscopic examination, which was judged by a glaucoma expert. The sensitivity and specificity, positive and negative predictive value, and receiver operating characteristic (ROC) curves of two algorithms for the FDT screening test, two algorithms for TOP, and three algorithms for HSF, as defined before the start of this study, were evaluated. The time required for each test was also analyzed. RESULTS: Values for area under the ROC curve ranged from 82.5%-93.9%. The largest area (93.9%) under the ROC curve was obtained with the FDT criteria, defining abnormality as presence of at least one abnormal location. Mean test time was 1.08 ± 0.28 minutes, 2.31 ± 0.28 minutes, and 4.14 ± 0.57 minutes for the FDT, TOP, and HSF, respectively. The difference in testing time was statistically significant (P <.0001). CONCLUSIONS: The C-20 FDT, G1-TOP, and 24-2 HSF appear to be useful tools to diagnose glaucoma. The test C-20 FDT and G1-TOP take approximately 1/4 and 1/2 of the time taken by 24 to 2 HSF. © 2002 by Elsevier Science Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the effect of cataract surgery on frequency doubling technology (FDT) perimetry in patients with coexisting cataract and glaucoma. Methods: In this consecutive prospective cohort study 27 patients with open angle glaucoma scheduled for cataract extraction alone or combined with trabeculectomy were enrolled. All patients underwent FDT threshold C-20 visual fields within 3 months before and 3 months after surgery. Changes in mean deviation (MD) and pattern standard deviation (PSD) were evaluated. Additionally, changes in best corrected logMAR visual acuity (VA), intraocular pressure (IOP), and number of glaucoma medications were also studied. Results: 22 patients completed the study. VA improved after surgery, from 0.47 (SD 0.19) to 0.12 (0.17) (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare the diagnostic abilities of the standard bracketing strategy (BR) and a fast strategy, the tendency-oriented perimetry (TOP). Methods: Seventy-seven controls and 91 eyes from patients with glaucoma were analyzed with the strategies TOP and BR. Sensitivity (Se), specificity (Sp), the area under the receiver operating characteristic (ROC) curve (AC) and the optimum cutoff value (CO) were calculated for the visual field indices mean defect (MD), the square root of the loss variance (sLV) and the number of pathological points (NPP). Results: In the glaucoma group, the mean MD value using TOP and BR was 7.5 and 8.3 dB, respectively. The mean sLV value using TOP and BR was 5.0 and 5.3 dB, respectively. Indices provided by TOP had higher ROC values than the ones provided by BR. Using TOP, the index with the best diagnostic ability was sLV (Sp = 94.8, Se = 90.1, AC = 0.966, CO = 2.5 dB), followed by NPP and MD. Using BR, the best results were obtained for MD (Sp = 92.2, Se = 81.3, AC = 0.900, CO = 2.5 dB) followed by sLV and NPP. Conclusions: A fast strategy, TOP, had superior diagnostic ability than the standard BR. Although TOP provided lower LV values than BR, the diagnostic ability of this index was higher than that of the conventional strategy. Copyright © 2005 S. Karger AG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To study the effect of topical dorzolamide on retinal sensitivity in normal subjects. Methods. 20 normal subjects were prospectively randomized in a two period crossover study. Baseline threshold perimetry (HVF, program 24-2, Statpac analysis) was obtained. The study eye was randomly chosen and then was randomly assigned to receive either dorzolamide 2% or placebo one hour before repeat HVF. After at least two weeks washout the same eye was given the opposite drop one hour prior to repeat HVF. Global indices were compared using a paired T-test. Results. AFTER PLACEBO AFTER DORZOLAMIDE P-VALUE (mean±SD) (mean±SD) MD 0.12±1.4 0.16±1.4 0.82 PSD 1.83±0.6 1.66±0.4 0.04 SF 1.28±0.4 1.24±0.2 0.73 CPSD 1.05±0.9 0.84±0.6 0.35 Conclusion. In this population, topical dorzolamide had little effect on visual function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To compare frequency-doubling technology (FDT) perimetry with standard automated perimetry (SAP) for detecting glaucomatous visual field progression in a longitudinal prospective study.

METHODS. One eye of patients with open-angle glaucoma was tested every 6 months with both FDT and SAP. A minimum of 6 examinations with each perimetric technique was required for inclusion. Visual field progression was determined by two methods: glaucoma change probability (GCP) analysis and linear regression analysis (LRA). For GCP, several criteria for progression were used. The number of locations required to classify progression with FDT compared with SAP, respectively, was 1:2 (least conservative), 1:3, 2:3, 2:4, 2:6, 2:7, 3:6, 3:7, and 3:10 (most conservative). The number of consecutive examinations required to confirm progression was 2-of-3, 2-of-2, and 3-of-3. For LRA, the progression criterion was any significant decline in mean threshold sensitivity over time in each of the following three visual field subdivisions: (1) all test locations, (2) locations in the central 10° and the superior and inferior hemifields, and (3) locations in each quadrant. Using these criteria, the proportion of patients classified as showing progression with each perimetric technique was calculated and, in the case of progression with both, the differences in time to progression were determined.

RESULTS. Sixty-five patients were followed for a median of 3.5 years (median number of examinations, 9). For the least conservative GCP criterion, 32 (49%) patients were found to have progressing visual fields with FDT and 32 (49%) patients with SAP. Only 16 (25%) patients showed progression with both methods, and in most of those patients, FDT identified progression before SAP (median, 12 months earlier). The majority of GCP progression criteria (15/27), classified more patients as showing progression with FDT than with SAP. Contrary to this, more patients showed progression with SAP than FDT, when analysed with LRA; e.g., using quadrant LRA 20 (31%) patients showed progression with FDT, 23 (35%) with SAP, and only 10 (15%) with both.

CONCLUSIONS. FDT perimetry detected glaucomatous visual field progression. However, the proportion of patients who showed progression with both FDT and SAP was small, possibly indicating that the two techniques identify different subgroups of patients. Using GCP, more patients showed progression with FDT than with SAP, yet the opposite occurred using LRA. As there is no independent qualifier of progression, FDT and SAP progression rates vary depending on the method of analysis and the criterion used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To review the clinical characteristics of patients with neuromyelitis optica (NMO) and to compare their visual outcome with those of patients with optic neuritis (ON) and multiple sclerosis (MS). Methods: Thirty-three patients with NMO underwent neuro-ophthalmic evaluation, including automated perimetry along with 30 patients with MS. Visual function in both groups was compared overall and specifically for eyes after a single episode of ON. Results: Visual function and average visual field (VF) mean deviation were significantly worse in eyes of patients with NMO. After a single episode of ON, the VF was normal in only 2 of 36 eyes of patients with NMO compared to 17 of 35 eyes with MS (P < 0.001). The statistical analysis indicated that after a single episode of ON, the odds ratio for having NMO was 6.0 (confidence interval [CI]: 1.6-21.9) when VF mean deviation was worse than -20.0 dB while the odds ratio for having MS was 16.0 (CI: 3.6-68.7) when better than -3.0 dB. Conclusion: Visual outcome was significantly worse in NMO than in MS. After a single episode of ON, suspicion of NMO should be raised in the presence of severe residual VF deficit with automated perimetry and lowered in the case of complete VF recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the relationship between glaucomatous structural damage assessed by the Cirrus Spectral Domain OCT (SDOCT) and functional loss as measured by standard automated perimetry (SAP). Methods: Four hundred twenty-two eyes (78 healthy, 210 suspects, 134 glaucomatous) of 250 patients were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study and from the African Descent and Glaucoma Evaluation Study. All eyes underwent testing with the Cirrus SDOCT and SAP within a 6-month period. The relationship between parapapillary retinal nerve fiber layer thickness (RNFL) sectors and corresponding topographic SAP locations was evaluated using locally weighted scatterplot smoothing and regression analysis. SAP sensitivity values were evaluated using both linear as well as logarithmic scales. We also tested the fit of a model (Hood) for structure-function relationship in glaucoma. Results: Structure was significantly related to function for all but the nasal thickness sector. The relationship was strongest for superotemporal RNFL thickness and inferonasal sensitivity (R(2) = 0.314, P < 0.001). The Hood model fitted the data relatively well with 88% of the eyes inside the 95% confidence interval predicted by the model. Conclusions: RNFL thinning measured by the Cirrus SDOCT was associated with correspondent visual field loss in glaucoma.