996 resultados para Ophthalmic tests


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: This study aimed to establish reference values for selected ophthalmic diagnostic tests in healthy neotropical primates from Salvador, Brazil. Methods: A total of 73 intact adults, including Callithrix jacchus (n = 31), Callithrix penicillata (n = 8), Cebus sp. (n = 22), and Cebus xanthosternos (n = 9) were used to evaluate the normal conjunctival bacterial flora. Cebus xanthosternos (n = 12) were used to evaluate tear production with Schirmer's tear test (STT), intraocular pressure (IOP), and conjunctival cytology. Results: For all animals evaluated, Gram-positive bacteria were predominant. Results of the diagnostic tests in Cebus xanthosternos were as follows: STT: 14.92 ± 5.46 mm/minutes, IOP: 19.62 ± 4.57 mmHg, and conjunctival cytology revealed intermediate squamous epithelial cells in great quantities. Conclusions: These ophthalmic reference values will be particularly useful to diagnose discrete or unusual pathological changes in the neotropical primates eye. © 2013 John Wiley & Sons A/S.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Over the past decade, corneal nerve morphology and corneal sensation threshold have been explored as potential surrogate markers for the evaluation of diabetic neuropathy. We present the baseline findings of a Longitudinal Assessment of Neuropathy in Diabetes using novel ophthalmic Markers (LANDMark). Methods The LANDMark Study is a 5-year, two-site, natural history (observational) study of individuals with Type 1 diabetes stratified into those with (T1W) and without (T1WO) neuropathy according to the Toronto criteria, and control subjects. All study participants undergo detailed annual assessment of neuropathy including corneal nerve parameters measured using corneal confocal microscopy and corneal sensitivity measured using non-contact corneal esthesiometry. Results 396 eligible individuals (208 in Brisbane and 188 in Manchester) were assessed: 76 T1W, 166 T1WO and 154 controls. Corneal sensation threshold (mbars) was significantly higher in T1W (1.0 ± 1.1) than T1WO (0.7 ± 0.7) and controls (0.6 ± 0.4) (P=0.002); post-hoc analysis (PHA) revealed no difference between T1WO and controls (Tukey HSD, P=0.502). Corneal nerve fiber length (mm/mm2) (CNFL) was lower in T1W (13.8 ± 6.4) than T1WO (19.1 ± 5.8) and controls (23.2 ± 6.3) (P<0.001); PHA revealed CNFL to be lower in T1W than T1WO, and lower in both of these groups than controls (P<0.001). Corneal nerve branch density (branches/mm2) (CNBD) was significantly lower in T1W (40 ± 32) than T1WO (62 ± 37) and controls (83 ± 46) (P<0.001); PHA showed CNBD was lower in T1W than T1WO, and lower in both groups than controls (P<0.001). Alcohol and cigarette consumption did not differ between groups, although age, BMI, BP, waist circumference, HbA1c, albumin-creatinine ratio, and cholesterol were slightly greater in T1W than T1WO (p<0.05). Some site differences were observed. Conclusions The LANDMark baseline findings confirm that corneal sensitivity and corneal nerve morphometry can detect differences in neuropathy status in individuals with Type 1 diabetes and healthy controls. Corneal nerve morphology is significantly abnormal even in diabetic patients ‘without neuropathy’ compared to control participants. Results of the longitudinal trial will assess the capability of these tests for monitoring change in these parameters over time as potential surrogate markers for neuropathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose:Over the past decade, corneal nerve morphology and corneal sensation threshold have been explored as potential surrogate markers for the evaluation of diabetic neuropathy. We present the baseline findings of a Longitudinal Assessment of Neuropathy in Diabetes using novel ophthalmic Markers (LANDMark). Methods:The LANDMark Study is a 5-year, two-site, natural history (observational) study of individuals with Type 1 diabetes stratified into those with (T1W) and without (T1WO) neuropathy according to the Toronto criteria, and control subjects. All study participants undergo detailed annual assessment of neuropathy including corneal nerve parameters measured using corneal confocal microscopy and corneal sensitivity measured using non-contact corneal esthesiometry. Results:396 eligible individuals (208 in Brisbane and 188 in Manchester) were assessed: 76 T1W, 166 T1WO and 154 controls. Corneal sensation threshold (mbars) was significantly higher in T1W (1.0 ± 1.1) than T1WO (0.7 ± 0.7) and controls (0.6 ± 0.4) (P=0.002); post-hoc analysis (PHA) revealed no difference between T1WO and controls (Tukey HSD, P=0.502). Corneal nerve fiber length (mm/mm2) (CNFL) was lower in T1W (13.8 ± 6.4) than T1WO (19.1 ± 5.8) and controls (23.2 ± 6.3) (P<0.001); PHA revealed CNFL to be lower in T1W than T1WO, and lower in both of these groups than controls (P<0.001). Corneal nerve branch density (branches/mm2) (CNBD) was significantly lower in T1W (40 ± 32) than T1WO (62 ± 37) and controls (83 ± 46) (P<0.001); PHA showed CNBD was lower in T1W than T1WO, and lower in both groups than controls (P<0.001). Alcohol and cigarette consumption did not differ between groups, although age, BMI, BP, waist circumference, HbA1c, albumin-creatinine ratio, and cholesterol were slightly greater in T1W than T1WO (p<0.05). Some site differences were observed. Conclusions:The LANDMark baseline findings confirm that corneal sensitivity and corneal nerve morphometry can detect differences in neuropathy status in individuals with Type 1 diabetes and healthy controls. Corneal nerve morphology is significantly abnormal even in diabetic patients ‘without neuropathy’ compared to control participants. Results of the longitudinal trial will assess the capability of these tests for monitoring change in these parameters over time as potential surrogate markers for neuropathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To evaluate the quality of reporting of all diagnostic studies published in five major ophthalmic journals in the year 2002 using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative parameters. Methods: Manual searching was used to identify diagnostic studies published in 2002 in five leading ophthalmic journals, the American Journal of Ophthalmology (AJO), Archives of Ophthalmology (Archives), British Journal of Ophthalmology (BJO), Investigative Ophthalmology and Visual Science (IOVS), and Ophthalmology. The STARD checklist of 25 items and flow chart was used to evaluate the quality of each publication. Results: A total of 16 publications were included (AJO = 5, Archives = 1, BJO = 2, IOVS = 2, and Ophthalmology = 6). More than half of the studies (n = 9) were related to glaucoma diagnosis. Other specialties included retina (n = 4) cornea (n = 2), and neuro-ophthalmology (n = 1). The most common description of diagnostic accuracy was sensitivity and specificity values, published in 13 articles. The number of fully reported items in evaluated studies ranged from eight to 19. Seven studies reported more than 50% of the STARD items. Conclusions: The current standards of reporting of diagnostic accuracy tests are highly variable. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The validation of a simple, sensitive and specific agar diffusion bioassay, applying cylinder-plate method, for the determination of the antibiotic azithromycin in ophthalmic solutions is described. Using a strain of Bacillus subtilis ATCC 9372 as the test organism, azithromycin at concentrations ranging from 50.0 to 200.0 μg·mL-1 could be measured in 1.666 7 mg·mL-1 ophthalmic solutions. A prospective validation of the method showed that the method was linear (r = 0.999 9) and precise (RSD = 0.70) and accurate (it measured the added quantities). The results obtained by bioassay method could be statistically calculated by linear parallel model and by means of regression analysis and verified using analysis of variance (ANOVA). We conclude that the microbiological assay is satisfactory for quantification of azithromycin in ophthalmic solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although the role of ophthalmic factors in dyslexia remains the subject of controversy, recent research has indicated that the correlates of dyslexia may include binocular dysfunction, unstable motor ocular dominance, a deficit of the transient visual subsystem, and an anomaly that can be treated with tinted lenses. These features, typically, have been studied in isolation and their inter-relationship has received little attention. The aim of the present research was to investigate ophthalmic factors in dyslexia, with a particular emphasis on the interaction between optometric variables. Further aims were to establish the most appropriate investigative techniques for optometric practice and to explore the relationship between optometric and psychometric variables. A pilot study was used to refine the experimental design for a subsequent detailed study of 39 children with a specific reading disability and 43 good readers, who were selected from 240 children. The groups were matched for age, sex, and performance IQ. The following factors emerged as correlates of dyslexia: slight impaired visual acuity; reduced vergence amplitudes; increased vergence instability; decreased accommodative amplitude; poor peformance at tests that were designed to assess the function of the transient visual system; and slightly slower performance at a non-verbal simulated reading visual search task. The `transient system deficit', as measured by reduced flicker sensitivity, was significantly associated with decreased accommodative and vergence amplitudes. This links the motor and sensory visual correlates of dyslexia. Although the binocular dysfunction was correlated with increased symptoms, the difference in the groups' simulated reading visual search task performance was largely attributable to psychometric variables. The results suggest tht optometric problems may be a contributory factor in dyslexia, but are unlikely to play a key causative role. Several optometric variables were confounded by psychometric parameters, and this interaction should be a priority for future investigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sizeable amount of the testing in eye care, requires either the identification of targets such as letters to assess functional vision, or the subjective evaluation of imagery by an examiner. Computers can render a variety of different targets on their monitors and can be used to store and analyse ophthalmic images. However, existing computing hardware tends to be large, screen resolutions are often too low, and objective assessments of ophthalmic images unreliable. Recent advances in mobile computing hardware and computer-vision systems can be used to enhance clinical testing in optometry. High resolution touch screens embedded in mobile devices, can render targets at a wide variety of distances and can be used to record and respond to patient responses, automating testing methods. This has opened up new opportunities in computerised near vision testing. Equally, new image processing techniques can be used to increase the validity and reliability of objective computer vision systems. Three novel apps for assessing reading speed, contrast sensitivity and amplitude of accommodation were created by the author to demonstrate the potential of mobile computing to enhance clinical measurement. The reading speed app could present sentences effectively, control illumination and automate the testing procedure for reading speed assessment. Meanwhile the contrast sensitivity app made use of a bit stealing technique and swept frequency target, to rapidly assess a patient’s full contrast sensitivity function at both near and far distances. Finally, customised electronic hardware was created and interfaced to an app on a smartphone device to allow free space amplitude of accommodation measurement. A new geometrical model of the tear film and a ray tracing simulation of a Placido disc topographer were produced to provide insights on the effect of tear film breakdown on ophthalmic images. Furthermore, a new computer vision system, that used a novel eye-lash segmentation technique, was created to demonstrate the potential of computer vision systems for the clinical assessment of tear stability. Studies undertaken by the author to assess the validity and repeatability of the novel apps, found that their repeatability was comparable to, or better, than existing clinical methods for reading speed and contrast sensitivity assessment. Furthermore, the apps offered reduced examination times in comparison to their paper based equivalents. The reading speed and amplitude of accommodation apps correlated highly with existing methods of assessment supporting their validity. Their still remains questions over the validity of using a swept frequency sine-wave target to assess patient’s contrast sensitivity functions as no clinical test provides the range of spatial frequencies and contrasts, nor equivalent assessment at distance and near. A validation study of the new computer vision system found that the authors tear metric correlated better with existing subjective measures of tear film stability than those of a competing computer-vision system. However, repeatability was poor in comparison to the subjective measures due to eye lash interference. The new mobile apps, computer vision system, and studies outlined in this thesis provide further insight into the potential of applying mobile and image processing technology to enhance clinical testing by eye care professionals.