899 resultados para OPTIC DISC


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mechanical principles of fibre-optic disc accelerometers (FODA) different from those assumed in previous calculation methods are presented. An FODA with a high sensitivity of 82 rad/ g and a resonance frequency of 360 Hz is designed and tested. In this system, the minimum measurable demodulation phase of the phase-generated carrier (PGC) is 10(-5) rad, and the minimum acceleration reaches 120 ng theoretically. This kind of FODA, with its high responsivity, all-optic-fibre configuration, small size, light weight and stiff shell housing, ensures effective performance in practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Image segmentation plays an important role in the analysis of retinal images as the extraction of the optic disk provides important cues for accurate diagnosis of various retinopathic diseases. In recent years, gradient vector flow (GVF) based algorithms have been used successfully to successfully segment a variety of medical imagery. However, due to the compromise of internal and external energy forces within the resulting partial differential equations, these methods can lead to less accurate segmentation results in certain cases. In this paper, we propose the use of a new mean shift-based GVF segmentation algorithm that drives the internal/external energies towards the correct direction. The proposed method incorporates a mean shift operation within the standard GVF cost function to arrive at a more accurate segmentation. Experimental results on a large dataset of retinal images demonstrate that the presented method optimally detects the border of the optic disc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims. To evaluate the effect of acute elevation of intraocular pressure (IOP) on optic disc cupping. Methods. 10 emmetropic and 10 myopic volunteers were included in this study. The cup area (CA) and cup volume (CV) of the optic disc were determined with the Heidelberg retina tomograph (HRT). After baseline determinations, a suction cup was used to increase the intraocular pressure (IOP) to 20-25 mmHg above the baseline and HRT images were obtained. Results. Baseline IOP was 13.5 (SD 1.3) mmHg and 12.6 (2.6) mmHg in the emmetropic and myopic groups, respectively. The IOP was elevated to 35.4 (3.3) mmHg and 34.4 (2.5) mmHg in the emmetropic and myopic groups, respectively. When compared with their baseline values, the cupping variables (CA and CV) were significantly increased (p <0.05) during the suction treatment in both emmetropic and myopic subjects. Conclusion. There was a significant enlargement in the optic disc cupping during the artificial increment of intraocular pressure in both emmetropic and myopic eyes. In non-glaucomatous eyes the optic nerve head has a partially dynamic topography dependent upon the level of IOP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims - To study the interchangeability of the measurements of the optic disc topography obtained by one computerised image analyser and one confocal laser tomographic scanner. Methods - One eye of 28 patients with glaucoma or glaucoma suspects was studied. All cases had simultaneous stereoscopic disc photographs taken with the fundus camera Topcon TRC-SS and optic disc examination with the Heidelberg retina tomograph (HRT) during the same visit. The optic disc photographs were digitised and analysed with the Topcon ImageNet (TI) system. Three variables of the optic disc topography provided by the TI and the HRT were compared - cup volume (CV), rim area (RA), and cup area to disc area ratio (CA/DA). Results - The mean values of CV and RA provided by the TI (0.52 (SD 0.32) mm and 1.58 (0.39) mm , respectively) were greater (p <0.01) than the mean values of CV and RA determined by the HRT (0.32 (0.25) mm , and 1.33 (0.47) mm , respectively). The mean value of CA/DA provided by the TI (0.42 (0.14)) and the HRT (0.42 (0.18)) was similar (p = 0.93). Correlation coefficients between measurements obtained by the two methods ranged from 0.53 to 0.73. Conclusion - There was a significant discrepancy in the measurements of rim area and cup volume of the optic disc obtained by a computerised image analyser and a laser scanning tomograph.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study was designed to evaluate the clinical agreement in the detection of optic disc changes and the ability of computerized image analysis to detect glaucomatous deterioration of the optic disc. Methods: Pairs of stereophotographs of 35 glaucomatous optic discs taken 5 years apart and of 5 glaucomatous discs photographed twice on the same day. Two glaucoma specialists examined the pairs of stereophotographs (35 cases and 5 controls) in a masked manner and judged whether the optic disc showed changes in the optic disc compatible with progression of glaucomatous damage. The stereophotographs of the five optic discs photographed twice on the same day (which by definition did not change) and of five cases judged to have deteriorated by both glaucoma specialists were analyzed by computerized image analysis with the Topcon ImageNet system. Intra- and inter-observer agreement in the detection of optic disc changes (evaluated using kappa statistic), and changes in the rim area to disc area ratio (evaluated using descriptive statistics and paired t-test). Results: Intra-observer agreement had a kappa value of 0.75 for observer 1 and 0.60 for the observer 2. Inter-observer agreement between the glaucoma specialists had a kappa value of 0.60. The image analyzer did not discriminate between controls and cases with clinically apparent glaucomatous change of the optic disc. Conclusion: Clinical agreement in detecting changes in the optic disc was moderate to substantial. Computerized image analysis with the Topcon ImageNet system appeared not to be useful in detecting glaucomatous changes of the optic disc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To detect and quantitate changes in optic nerve morphology after glaucoma surgery using the Heidelberg Retina Tomograph (HRT, Heidelberg Instruments, Heidelberg, Germany). Design: Nonconsecutive observational case series. Participants and Intervention: The authors prospectively enrolled 21 adult patients undergoing incisional glaucoma surgery for progressive glaucoma damage. Quantitative analysis of the optic nerve head by scanning laser tomography and automated perimetry were performed before and after glaucoma surgery. Main Outcome Measures: Changes in optic nerve parameters were subjected to linear regression analysis with respect to percent of postoperative reduction of intraocular pressure (IOP), as well as with respect to age, refraction, preoperative cup:disc ratio, and change in visual field parameters. Results: Seventeen patients had pre- and postoperative images suitable for analysis. Mean IOP at the time of image acquisition before surgery was 30.5 ± 12 mmHg, and after surgery 11.8 ± 5.2 mmHg (mean follow-up, 26 ± 7 weeks). Eleven of 13 (85%) patients having IOP reduction of greater than 40% showed improvement in optic disc parameters. All four patients with less than 25% reduction in IOP showed worsening of most parameters. Changes in optic disc parameters were highly correlated with percent IOP reduction and with age. The parameters in which change most strongly correlated with percent change of IOP were cup area, rim area, cup:disc ratio, and mean cup depth (each, P <0.005). The age of the patient correlated highly with change in maximum cup depth (P <0.005). Refraction and clinically determined cup:disc ratio correlated poorly with changes in measured optic disc parameters. Clinical improvement in visual fields was correlated with the degree of improvement of cup:disc ratio (P = 0.025). Conclusion: Most patients showing a 40% lowering of IOP after glaucoma surgery show improved optic nerve morphology as measured by the HRT. The amount of improvement correlated highly with the percent reduction of IOP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Efficient optic disc segmentation is an important task in automated retinal screening. For the same reason optic disc detection is fundamental for medical references and is important for the retinal image analysis application. The most difficult problem of optic disc extraction is to locate the region of interest. Moreover it is a time consuming task. This paper tries to overcome this barrier by presenting an automated method for optic disc boundary extraction using Fuzzy C Means combined with thresholding. The discs determined by the new method agree relatively well with those determined by the experts. The present method has been validated on a data set of 110 colour fundus images from DRION database, and has obtained promising results. The performance of the system is evaluated using the difference in horizontal and vertical diameters of the obtained disc boundary and that of the ground truth obtained from two expert ophthalmologists. For the 25 test images selected from the 110 colour fundus images, the Pearson correlation of the ground truth diameters with the detected diameters by the new method are 0.946 and 0.958 and, 0.94 and 0.974 respectively. From the scatter plot, it is shown that the ground truth and detected diameters have a high positive correlation. This computerized analysis of optic disc is very useful for the diagnosis of retinal diseases

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. The authors compared the visual gaze behaviors of glaucoma subspecialists with those of ophthalmology trainees during optic disc and retinal nerve fiber layer (RNFL) examination.

Methods. Seven glaucoma subspecialists and 23 ophthalmology trainees participated in the project. Participants were shown eight glaucomatous optic disc images with varied morphology. Eye movements during examination of the optic disc photographs were tracked. For each disc image, graders were asked to assign a presumptive diagnosis for probability of glaucoma. There was no time restriction.

Results. Overall, trainees spent more time looking at disc images than glaucoma subspecialists (21.3 [13.9–37.7] vs. 16.6 [12.7–19.7]) seconds; median [interquartile range (IQR)], respectively; P < 0.01) and had no systematic patterns of gaze behavior, and gaze behavior was unaltered by disc morphology or topographic cues of pathology. Experienced viewers demonstrated more systematic and ordered gaze behavior patterns and spent longer times observing areas with the greatest likelihood of pathology (superior and inferior poles of the optic nerve head and adjacent RNFL) compared with the trainees. For discs with focal pathology, the proportion of total time spent examining definite areas of pathology was 28.9% (22.4%–33.6%) for glaucoma subspecialists and 13.5% (12.2%–19.2%) for trainees (median [IQR]; P < 0.05). Furthermore, experts adapted their viewing habits according to disc morphology.

Conclusions. Glaucoma subspecialists adopt systematic gaze behavior when examining the optic nerve and RNFL, whereas trainees do not. It remains to be elucidated whether incorporating systematic viewing behavior of the optic disc and RNFL into teaching programs for trainees may expedite their acquisition of accurate and efficient glaucoma diagnosis skills.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. We previously demonstrated that most eyes have regionally variable extensions of Bruch's membrane (BM) inside the clinically identified disc margin (DM) that are clinically and photographically invisible. We studied the impact of these findings on DM- and BM opening (BMO)-derived neuroretinal rim parameters. METHODS. Disc stereo-photography and spectral domain optical coherence tomography (SD-OCT, 24 radial B-scans centered on the optic nerve head) were performed on 30 glaucoma patients and 10 age-matched controls. Photographs were colocalized to SD-OCT data such that the DM and BMO could be visualized in each B-scan. Three parameters were computed: (1) DM-horizontal rim width (HRW), the distance between the DM and internal limiting membrane (ILM) along the DM reference plane; (2) BMO-HRW, the distance between BMO and ILM along the BMO reference plane; and (3) BMO-minimum rim width (MRW), the minimum distance between BMO and ILM. Rank-order correlations of sectors ranked by rim width and spatial concordance measured as angular distances between equivalently ranked sectors were derived. RESULTS. The average DM position was external to BMO in all quadrants, except inferotemporally. There were significant sectoral differences among all three rim parameters. DM- HRW and BMO-HRW sector ranks were better correlated (median rho = 0.84) than DM- HRW and BMO-MRW (median rho = 0.55), or BMO-HRW and BMO-MRW (median rho = 0.60) ranks. Sectors with the narrowest BMO-MRW were infrequently the same as those with the narrowest DM-HRW or BMO-HRW. CONCLUSIONS. BMO-MRW quantifies the neuroretinal rim from a true anatomical outer border and accounts for its variable trajectory at the point of measurement. (Invest Ophthalmol Vis Sci. 2012;53:1852-1860) DOI:10.1167/iovs.11-9309

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To characterize optic nerve head (ONH) anatomy related to the clinical optic disc margin with spectral domain-optical coherence tomography (SD-OCT). Design: Cross-sectional study. Participants: Patients with open-angle glaucoma with focal, diffuse, and sclerotic optic disc damage, and age-matched normal controls. Methods: High-resolution radial SD-OCT B-scans centered on the ONH were analyzed at each clock hour. For each scan, the border tissue of Elschnig was classified for obliqueness (internally oblique, externally oblique, or nonoblique) and the presence of Bruch's membrane overhanging the border tissue. Optic disc stereophotographs were co-localized to SD-OCT data with customized software. The frequency with which the disc margin identified in stereophotographs coincided with (1) Bruch's membrane opening (BMO), defined as the innermost edge of Bruch's membrane; (2) Bruch's membrane/border tissue, defined as any aspect of either outside BMO or border tissue; or (3) border tissue, defined as any aspect of border tissue alone, in the B-scans was computed at each clock hour. Main Outcome Measures: The SD-OCT structures coinciding with the disc margin in stereophotographs. Results: There were 30 patients (10 with each type of disc damage) and 10 controls, with a median (range) age of 68.1 (42-86) years and 63.5 (42-77) years, respectively. Although 28 patients (93%) had 2 or more border tissue configurations, the most predominant one was internally oblique, primarily superiorly and nasally, frequently with Bruch's membrane overhang. Externally oblique border tissue was less frequent, observed mostly inferiorly and temporally. In controls, there was predominantly internally oblique configuration around the disc. Although the configurations were not statistically different between patients and controls, they were among the 3 glaucoma groups. At most locations, the SD-OCT structure most frequently identified as the disc margin was some aspect of Bruch's membrane and border tissue external to BMO. Bruch's membrane overhang was regionally present in the majority of patients with glaucoma and controls; however, in most cases it was not visible as the disc margin. Conclusions: The clinically perceived disc margin is most likely not the innermost edge of Bruch's membrane detected by SD-OCT. These findings have important implications for the automated detection of the disc margin and estimates of the neuroretinal rim. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2012;119:738-747 (C) 2012 by the American Academy of Ophthalmology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the rate of visual field and optic disc change in patients with distinct patterns of glaucomatous optic disc damage. Design: Prospective longitudinal study. Participants: A total of 131 patients with open-angle glaucoma with focal (n = 45), diffuse (n = 42), and sclerotic (n = 44) optic disc damage. Methods: Patients were examined every 4 months with standard automated perimetry (SAP, SITA Standard, 24-2 test, Humphrey Field Analyzer, Carl Zeiss Meditec, Dublin, CA) and confocal scanning laser tomography (CSLT, Heidelberg Retina Tomograph, Heidelberg Engineering GmbH, Heidelberg, Germany) for a period of 4 years. During this time, patients were treated according to a predefined protocol to achieve a target intraocular pressure (IOP). Rates of change were estimated by robust linear regression of visual field mean deviation (MD) and global optic disc neuroretinal rim area with follow-up time. Main Outcome Measures: Rates of change in MD and rim area. Results: Rates of visual field change in patients with focal optic disc damage (mean -0.34, standard deviation [SD] 0.69 dB/year) were faster than in patients with sclerotic (mean - 0.14, SD 0.77 dB/year) and diffuse (mean + 0.01, SD 0.37 dB/year) optic disc damage (P = 0.003, Kruskal-Wallis). Rates of optic disc change in patients with focal optic disc damage (mean - 11.70, SD 25.5 x 10(-3) mm(2)/year) were faster than in patients with diffuse (mean -9.16, SD 14.9 x 10(-3) mm(2)/year) and sclerotic (mean -0.45, SD 20.6 x 10(-3) mm(2)/year) optic disc damage, although the differences were not statistically significant (P = 0.11). Absolute IOP reduction from untreated levels was similar among the groups (P = 0.59). Conclusions: Patients with focal optic disc damage had faster rates of visual field change and a tendency toward faster rates of optic disc deterioration when compared with patients with diffuse and sclerotic optic disc damage, despite similar IOP reductions during follow-up. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2012; 119: 294-303 (C) 2012 by the American Academy of Ophthalmology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To determine the incidence of optic disc swelling as a possible indicator of cerebral edema in a large group of healthy mountaineers exposed to very high altitudes and to correlate these findings with various clinical and environmental factors and occurrence of acute mountain sickness and high-altitude cerebral edema. METHODS: This multidisciplinary, prospective, observational cohort study was performed in 2005 within the scope of a medical research expedition to Muztagh Ata (7546 m [24,751 ft]) in Western Xinjiang Province, China. Twenty-seven healthy mountaineers aged 26 to 62 years participated. Medical examinations were performed in Switzerland 1 month before and 4 1/2 months after the expedition. Ophthalmologic examinations were performed at 4 high camps (maximum elevation, 6865 m [22,517 ft]). Optic disc status was documented using digital photography. Further assessments included arterial oxygen saturation and cerebral acute mountain sickness scores. RESULTS: Sixteen of 27 study subjects (59%) exhibited optic disc swelling during their stay at high altitudes, with complete regression on return to lowlands. Significant correlation was noted between optic disc swelling and lower arterial oxygen saturation (odds ratio, 0.86 per percentage of arterial oxygen saturation; 95% confidence interval, 0.81-0.92; P < .001), younger age (odds ratio, 0.95 per year; 95% confidence interval, 0.90-0.99; P = .03), and higher cerebral acute mountain sickness scores (odds ratio, 2.32 per 0.1 point; 95% confidence interval, 1.48-3.63; P < .001). CONCLUSION: Optic disc swelling occurs frequently in high-altitude climbers and is correlated with peripheral oxygen saturation and symptoms of acute mountain sickness. It is most likely the result of hypoxia-induced brain volume increase.