991 resultados para NATURAL-WATERS


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes an electrochemical and quantum chemical investigation of the fipronil insecticide. Cyclic voltammetry (CV) and square wave voltammetry (SWV) experiments were performed over a graphite-polyurethane (GPU) composite electrode. The fipronil molecule presents an one?electron irreversible oxidation reaction. Profiting the SWV signal a square wave stripping voltammetry (SWSV) procedure to determine the fipronil molecule in a 0.10 mol L-1 Britton-Robinson buffer solution, pH 8.0 was developed with accumulation potential and time of 0.50 V and 120 s, respectively. The limits of detection and quantification were 0.80 and 2.67 ?g L-1, respectively. Recovery tests were performed in three natural waters samples with values ranging from 99.67 to 101.37%. Quantum chemical studies showed that the nitrogen atom of the pyrazole group is the most probable oxidation site of the fipronil molecule.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Les agents anti-infectieux sont utilisés pour traiter ou prévenir les infections chez les humains, les animaux, les insectes et les plantes. L’apparition de traces de ces substances dans les eaux usées, les eaux naturelles et même l’eau potable dans plusieurs pays du monde soulève l’inquiétude de la communauté scientifique surtout à cause de leur activité biologique. Le but de ces travaux de recherche a été d’étudier la présence d’anti-infectieux dans les eaux environnementales contaminées (c.-à-d. eaux usées, eaux naturelles et eau potable) ainsi que de développer de nouvelles méthodes analytiques capables de quantifier et confirmer leur présence dans ces matrices. Une méta-analyse sur l’occurrence des anti-infectieux dans les eaux environnementales contaminées a démontré qu’au moins 68 composés et 10 de leurs produits de transformation ont été quantifiés à ce jour. Les concentrations environnementales varient entre 0.1 ng/L et 1 mg/L, selon le composé, la matrice et la source de contamination. D’après cette étude, les effets nuisibles des anti-infectieux sur le biote aquatique sont possibles et ces substances peuvent aussi avoir un effet indirect sur la santé humaine à cause de sa possible contribution à la dissémination de la résistance aux anti-infecteiux chez les bactéries. Les premiers tests préliminaires de développement d’une méthode de détermination des anti-infectieux dans les eaux usées ont montré les difficultés à surmonter lors de l’extraction sur phase solide (SPE) ainsi que l’importance de la sélectivité du détecteur. On a décrit une nouvelle méthode de quantification des anti-infectieux utilisant la SPE en tandem dans le mode manuel et la chromatographie liquide couplée à la spectrométrie de masse en tandem (LC-MS/MS). Les six anti-infectieux ciblés (sulfaméthoxazole, triméthoprime, ciprofloxacin, levofloxacin, clarithromycin et azithromycin) ont été quantifiés à des concentrations entre 39 et 276 ng/L dans les échantillons d’affluent et d’effluent provenant d’une station d’épuration appliquant un traitement primaire et physico- chimique. Les concentrations retrouvées dans les effluents indiquent que la masse moyenne totale de ces substances, déversées hebdomadairement dans le fleuve St. Laurent, était de ~ 2 kg. En vue de réduire le temps total d’analyse et simplifier les manipulations, on a travaillé sur une nouvelle méthode de SPE couplée-LC-MS/MS. Cette méthode a utilisé une technique de permutation de colonnes pour préconcentrer 1.00 mL d’échantillon dans une colonne de SPE couplée. La performance analytique de la méthode a permis la quantification des six anti-infectieux dans les eaux usées municipales et les limites de détection étaient du même ordre de grandeur (13-60 ng/L) que les méthodes basées sur la SPE manuelle. Ensuite, l’application des colonnes de SPE couplée de chromatographie à débit turbulent pour la préconcentration de six anti-infectieux dans les eaux usées a été explorée pour diminuer les effets de matrice. Les résultats obtenus ont indiqué que ces colonnes sont une solution de réchange intéressante aux colonnes de SPE couplée traditionnelles. Finalement, en vue de permettre l’analyse des anti-infectieux dans les eaux de surface et l’eau potable, une méthode SPE couplée-LC-MS/MS utilisant des injections de grand volume (10 mL) a été développée. Le volume de fuite de plusieurs colonnes de SPE couplée a été estimé et la colonne ayant la meilleure rétention a été choisie. Les limites de détection et de confirmation de la méthode ont été entre 1 à 6 ng/L. L’analyse des échantillons réels a démontré que la concentration des trois anti-infectieux ciblés (sulfaméthoxazole, triméthoprime et clarithromycine) était au dessous de la limite de détection de la méthode. La mesure des masses exactes par spectrométrie de masse à temps d’envol et les spectres des ions produits utilisant une pente d’énergie de collision inverse dans un spectromètre de masse à triple quadripôle ont été explorés comme des méthodes de confirmation possibles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Avec la hausse mondiale de la fréquence des floraisons de cyanobactéries (CB), dont certaines produisent des cyanotoxines (CT), le développement d’une méthode de détection/quantification rapide d’un maximum de CT s’impose. Cette méthode permettrait de faire un suivi quotidien de la toxicité de plans d’eau contaminés par des CB et ainsi d’émettre rapidement des avis d’alerte appropriés afin de protéger la santé publique. Une nouvelle technologie utilisant la désorption thermique induite par diode laser (LDTD) couplée à l’ionisation chimique sous pression atmosphérique (APCI) et reliée à la spectrométrie de masse en tandem (MS/MS) a déjà fait ses preuves avec des temps d'analyse de l’ordre de quelques secondes. Les analytes sont désorbés par la LDTD, ionisés en phase gazeuse par APCI et détectés par la MS/MS. Il n’y a donc pas de séparation chromatographique, et la préparation de l’échantillon avant l’analyse est minimale selon la complexité de la matrice contenant les analytes. Parmi les quatre CT testées (microcystine-LR, cylindrospermopsine, saxitoxine et anatoxine-a (ANA-a)), seule l’ANA-a a généré une désorption significative nécessaire au développement d’une méthode analytique avec l’interface LDTD-APCI. La forte polarité ou le poids moléculaire élevé des autres CT empêche probablement leur désorption. L’optimisation des paramètres instrumentaux, tout en tenant compte de l’interférence isobarique de l’acide aminé phénylalanine (PHE) lors de la détection de l’ANA-a par MS/MS, a généré une limite de détection d’ANA-a de l’ordre de 1 ug/L. Celle-ci a été évaluée à partir d’une matrice apparentée à une matrice réelle, démontrant qu’il serait possible d’utiliser la LDTD pour effectuer le suivi de l’ANA-a dans les eaux naturelles selon les normes environnementales applicables (1 à 12 ug/L). Il a été possible d’éviter l’interférence isobarique de la PHE en raison de sa très faible désorption avec l’interface LDTD-APCI. En effet, il a été démontré qu’une concentration aussi élevée que 500 ug/L de PHE ne causait aucune interférence sur le signal de l’ANA-a.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Le présent projet vise à documenter la nécessité d’augmenter notre connaissance de la présence des contaminants organiques tels que les médicaments dans l’environnement et d’évaluer leur devenir environnemental. On a étudié la présence de composés pharmaceutiques dans différents échantillons d'eau. On a focalisé nos efforts spécialement sur les échantillons d'eau de l'usine d'épuration de la Ville de Montréal et ses effluents, les eaux de surface avoisinantes et l’eau du robinet dans la région de Montréal. Pour ce faire, on a tout d’abord développé deux méthodes analytiques automatisées basées sur la chromatographie liquide avec extraction en phase solide (SPE) couplée à la chromatographie liquide couplée à la spectrométrie de masse en tandem (LC-MS/MS). On a également étudié les performances des trois techniques d'ionisation à pression atmosphérique (API), pour ensuite les utiliser dans la méthode analytique développée. On a démontré que l'ionisation par électronébulisation (ESI) est une méthode d'ionisation plus efficace pour l'analyse des contaminants pharmaceutiques dans des échantillons de matrices très complexes comme les eaux usées. Une première méthode analytique SPE couplée à la LC-MS/MS a été développée et validée pour l'étude des échantillons complexes provenant de l'usine d'épuration de la Ville de Montréal et des eaux de surface près de l'usine. Cinq médicaments de prescription ont été étudiés: le bézafibrate (un régulateur de lipides), le cyclophosphamide et le méthotrexate (deux agents anticancéreux), l'orlistat (un agent anti-obésité) et l’énalapril (utilisé dans le traitement de l'hypertension). La plupart de ces drogues sont excrétées par le corps humain et rejetées dans les eaux usées domestiques en faisant par la suite leur chemin vers les usines municipales de traitement des eaux usées. On a pu démontrer qu'il y a un faible taux d’élimination à l'usine d'épuration pour le bézafibrate et l'énalapril. Ces deux composés ont aussi été détectés dans les eaux de surface sur un site à proximité immédiate de la décharge de l’effluent de la station d'épuration. i En observant la nécessité de l'amélioration des limites de détection de la première méthode analytique, une deuxième méthode a été développée. Pour la deuxième méthode, un total de 14 contaminants organiques, incluant trois agents anti-infectieux (clarithromycin, sulfaméthoxazole et triméthoprime), un anticonvulsant (carbamazépine) et son produit de dégradation (10,11-dihydrocarbamazépine), l'agent antihypertensif (enalapril), deux antinéoplastiques utilisés en chimiothérapie (cyclophosphamide et méthotrexate), des herbicides (atrazine, cyanazine, et simazine) et deux produits de transformation de l’atrazine (deséthylatrazine et déisopropylatrazine) ainsi qu’un agent antiseptique (triclocarban). Ces produits ont été quantifiés dans les eaux de surface ainsi que dans l’eau du robinet. L'amélioration des limites de détection pour cette méthode a été possible grâce à la charge d'un volume d'échantillon supérieur à celui utilisé dans la première méthode (10 mL vs 1 mL). D'autres techniques de confirmation, telles que les spectres des ions produits utilisant une pente d’énergie de collision inverse dans un spectromètre de masse à triple quadripôle et la mesure des masses exactes par spectrométrie de masse à temps d’envol, ont été explorées. L'utilisation d'un analyseur de masse à temps d’envol a permis la confirmation de 6 des 14 analytes. Finalement, étant donné leur haute toxicité et pour évaluer leur persistance et leur transformation au niveau du traitement des eaux potables, la cinétique d'oxydation du cyclophosphamide et de méthotrexate avec l'ozone moléculaire et des radicaux OH a été étudiée. Les constantes de dégradation avec l'ozone moléculaire ont été calculées et la qualité de l'eau après traitement a pu être évaluée. Le rendement du processus d'ozonation a été amélioré pour la cyclophosphamide dans les eaux naturelles, en raison de la combinaison de réactions directes et indirectes. Cette étude a montré que l'ozone est très efficace pour oxyder le méthotrexate mais que le cyclophosphamide serait trop lent à s’oxyder pour un traitement efficace aux conditions usuelles de traitement de l’eau potable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Les nanomatériaux sont une classe de contaminants qui est de plus en plus présent dans l’environnement. Leur impact sur l’environnement dépendra de leur persistance, mobilité, toxicité et bioaccumulation. Chacun de ces paramètres dépendra de leur comportement physicochimique dans les eaux naturelles (i.e. dissolution et agglomération). L’objectif de cette étude est de comprendre l’agglomération et l’hétéroagglomération des nanoparticules d’argent dans l’environnement. Deux différentes sortes de nanoparticules d’argent (nAg; avec enrobage de citrate et avec enrobage d’acide polyacrylique) de 5 nm de diamètre ont été marquées de manière covalente à l’aide d’un marqueur fluorescent et ont été mélangées avec des colloïdes d’oxyde de silice (SiO2) ou d’argile (montmorillonite). L’homo- et hétéroagglomération des nAg ont été étudiés dans des conditions représentatives d’eaux douces naturelles (pH 7,0; force ionique 10 7 à 10-1 M de Ca2+). Les tailles ont été mesurées par spectroscopie de corrélation par fluorescence (FCS) et les résultats ont été confirmés à l’aide de la microscopie en champ sombre avec imagerie hyperspectrale (HSI). Les résultats ont démontrés que les nanoparticules d’argent à enrobage d’acide polyacrylique sont extrêmement stables sous toutes les conditions imposées, incluant la présence d’autres colloïdes et à des forces ioniques très élevées tandis que les nanoparticules d’argent avec enrobage de citrate ont formées des hétéroagrégats en présence des deux particules colloïdales.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Department of Chemical Oceanography,Cochin University of Science and Technology

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis Entitled Trace metal speciation in the cochin estuary.Natural waters provide a favourable environment for speciation studies because of the prevailing variable chemical matrix and the variety of metal forms which may exist there.An estuary is a mixing zone of riverine and oceanic waters with widely varying compositions where end members interact both physically and chemically. The trace element chemistry in the estuarine environment has been an area of considerable research in the past decades. The trace metal distribution in the Cochin estuary is considerably influenced by the tropical features of the location and by human activities. The lower Periyar river and the Cochin estuary have been particularly selected for this investigation in view of the impact of trace metals on the estuarine ecosystem as well as in attempt quantify the phenomenon of metal speciation in the waters of a tropical coastal plain waterbody. If the concentration in the water media is very low, then, many of the fractions that could be estimated by speciation schemes for metals will fall below the detection limits, a factor which is undesirable.The study would also delineate the features of metal speciation which modify the chemical regime of ionic elements that traverse natural boundaries in aquatic environments, especally in those tropical areas prone to multivariate geographical settings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Kerala Water Authority requested the School of Environmental Studies to carry out investigations on the mechanism of sporadic mobilization of iron and odour in the raw water drawn to the drinking water treatment plant. The currently used treatment process failed to remove iron completely. This led to problems in the filter and complaints of taste and colour due to iron in the finished water. The sporadic nature of the problem itself made the trouble shooting difficult. The problem was looked in from three points of view. 1. Influence of environmental (climatic) conditions on the dynamics of the relevant basin of the reservoir. 2. Influence of the physical dynamics on the physico — chemical quality of water. 3. Identification of cost-effective treatment processes to suit the existing plant. Since the problem emerged only during the post- monsoon to pre-monsoon months, a related problem was investigated, namely, influence of anions on the oxidation of Fe(II) in natural waters by air. This is presented in Part II of the dissertation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A total of eighty-one Escherichia coli isolates belonging to forty-three different serotypes including several pathogenic strains such as enterotoxigenic E. coli (ETEC), enterohaemorrhagic E. coli (EHEC), enteropathogenic E. coli (EPEC) and uropathogenic E. coli (UPEC) isolated from Cochin estuary between November 2001 and October 2002 were tested against twelve antibiotics to determine the prevalence of multiple antibiotic resistance (MAR) and antimicrobial resistance profiles as a measure of high risk source of contamination. The results revealed that more than 95% of the isolates were multiple antibiotic resistant (resistant to more than three antibiotics). The MAR indexing of the isolates showed that all these strains originated from high risk source of contamination. The incidence of multiple antibiotic resistant E. coli especially the pathogenic strains in natural waters will pose a serious threat to human population

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The survival of Escherichia coli in tropical estuarine water has been studied under controlled laboratory conditions using microcosms. The survival has been assessed in terms of various self purifying factors of the natural waters such as biological, chemical and physical factors. The biological factors considered included competition from other microorganisms, predation by protozoa and coliphages. The suitability of the chemical composition of estuarine water has been studied under chemical factors and negative impact of sunlight has been studied under physical factors. The results revealed that sunlight exerted maximum negative impact, followed by biotic factors contained in the estuarine water. However, the chemical composition of the estuarine water is found to be suitable for the growth and survival of E. coli. The injury exerted by each of the above factors was also evaluated by using a selective and non-selective medium in conjunction. It was found that sunlight resulted in 100% injury of the cells as the cells failed to develop in a selective medium. While, sunlight resulted in the extinction of 90% of the E. coli cells within the first two hours of exposure, biotic factors took nearly 24 hours to remove the same amount of population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The thesis deals with the prevalence and distribution of motile aeromonads in selected ornamental fishes. The presence of motile aeromonads in ornamental fishes and associated carriage water is well documented. Though aeromonads are a part of autochthonous flora of natural waters, disease outbreak occurs as a result of environmental stress on the cultured species and virulence of the pathogens. While ornamental aquaculture in many parts of the world is highly organized and practiced scientifically, it is highly unorganized in India. The culture ponds/tanks are often maintained in very poor manner and the fishes are subjected to high degree of stress during transportation from the production facility to retail vendors. The situation is no better at retail outlets, where fishes are maintained in crowded condition without proper aeration or food. All these could result in high prevalence of diseases caused by motile aeromonads. No systematic study has been carried out to understand the prevalence of motile aeromonads in ornamental fishes and carriage water . It also gives an account of the production of extracellular virulence factors and the antibiogram of the different species of motile aeromonads isolated. The growth characteristics and virulence potential of a representative strain of Aeromonas hydrophila is also studied. The nucleotide sequencing of the strain was carried out and sequences deposited in Genbank. Survival and immune response of Cyprinus carpio under different stress conditions and on probiotic treatment with Bacillus NL110, when challenged with A. hydrophila is also dealt within this thesis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El glifosat, N-(fosfonometil) glicina, és un dels herbicides més utilitzats arreu del món a causa de la seva baixa toxicitat i al seu ampli espectre d'aplicació. A conseqüència del gran ús que se'n fa, és necessari monitoritzar aquest compost i el seu principal metabòlit, l'àcid aminometilfosfònic (AMPA), en el medi ambient. S'han descrit diversos mètodes instrumentals basats en cromatografia de gasos (GC) i de líquids (HPLC), sent aquesta darrera l'opció més favorable a causa del caràcter polar dels anàlits. Per assolir nivells de concentració baixos cal, però, la preconcentració dels anàlits. En aquest treball s'estudien diferents alternatives amb aquest objectiu. S'ha avaluat la tècnica de membrana líquida suportada (SLM) on la membrana consisteix en una dissolució orgànica, que conté un transportador (en el nostre cas, un bescanviador d'anions comercial, Aliquat 336), que impregna un suport polimèric microporós que se situa entre dues solucions aquoses: la de càrrega, que conté els anàlits inicialment, i la receptora, on es retenen els anàlits després del seu transport a través de la membrana. Les condicions d'extracció més adequades s'obtenen treballant en medi bàsic amb NaOH on els anàlits estan en forma aniònica i les majors recuperacions s'obtenen amb HCl 0,1 M o NaCl 0,5 M, la qual cosa indica que l'ió clorur és la força impulsora del transport. Un cop dissenyat el sistema, es duen a terme experiments de preconcentració amb dues geometries diferents: un sistema de membrana laminar (LSLM) on recircula la fase receptora i un sistema de fibra buida (HFSLM). Els millors resultats s'obtenen amb el mòdul de fibra buida, amb factors de concentració de 25 i 3 per a glifosat i AMPA, respectivament, fent recircular durant 24 hores 100 ml de solució de càrrega i 4 ml de solució receptora. També s'aplica una tècnica més selectiva, la cromatografia d'afinitat amb ió metàl·lic immobilitzat (IMAC), basada en la interacció entre els anàlits i un metall immobilitzat en una resina a través d'un grup funcional d'aquesta. En aquest estudi s'immobilitza pal·ladi al grup funcional 8-hidroxiquinoleïna de la resina amb matriu acrílica Spheron Oxine 1000 i s'avalua per a l'extracció i preconcentració de glifosat i AMPA. Per a ambdós anàlits l'adsorció és del 100 % i les recuperacions són superiors al 80 % i al 60 % per a glifosat i AMPA, respectivament, utilitzant HCl 0,1 M + NaCl 1 M com a eluent. Aquests resultats es comparen amb els obtinguts amb dues resines més, també carregades amb pal·ladi: Iontosorb Oxin 100, que té el mateix grup funcional però matriu de cel·lulosa, i Spheron Thiol 1000, on el grup funcional és un tiol i la matriu també és acrílica. Per al glifosat els resultats són similars amb totes les resines, però per a l'AMPA la resina Spheron Thiol és la única que proporciona recuperacions superiors al 93 %. Finalment, una altra opció estudiada és l'acoblament de dues columnes de cromatografia líquida (LC-LC). En l'estudi l'objectiu és millorar el mètode existent per a glifosat i AMPA en aigües naturals on el LOD era de 0,25 ug/l. El mètode consisteix en la derivatització precolumna amb el reactiu fluorescent FMOC i l'anàlisi amb l'acoblament LC-LC-fluorescència. Variant lleugerament les condicions de derivatització s'aconsegueix quantificar 0,1 ug/l de glifosat i AMPA. Es fortifiquen aigües naturals amb 0,1, 1 i 10 ug/l dels anàlits per validar el mètode. S'obtenen recuperacions d'entre el 85 % i el 100 %, amb desviacions estàndard relatives inferiors al 8 %. Aplicant una tècnica de preconcentració prèvia a la derivatització i anàlisi utilitzant una resina de bescanvi aniònic, Amberlite IRA-900, es millora la sensibilitat del mètode i s'assoleix un LOD per al glifosat de 0,02 ug/l.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In plankton ecology, it is a fundamental question as to how a large number of competing phytoplankton species coexist in marine ecosystems under a seemingly-limited variety of resources. This ever-green question was first proposed by Hutchinson [Hutchinson, G.E., 1961. The paradox of the plankton. Am. Nat. 95, 137–145] as ‘the paradox of the plankton’. Starting from Hutchinson [Hutchinson, G.E., 1961. The paradox of the plankton. Am. Nat. 95, 137–145], over more than four decades several investigators have put forward varieties of mechanisms for the extreme diversity of phytoplankton species. In this article, within the boundary of our knowledge, we review the literature of the proposed solutions and give a brief overview of the mechanisms proposed so far. The proposed mechanisms that we discuss mainly include spatial and temporal heterogeneity in physical and biological environment, externally imposed or self-generated spatial segregation, horizontal mesoscale turbulence of ocean characterized by coherent vortices, oscillation and chaos generated by several internal and external causes, stable coexistence and compensatory dynamics under fluctuating temperature in resource competition, and finally the role of toxin-producing phytoplankton in maintaining the coexistence and biodiversity of the overall plankton population that we have proposed recently. We find that, although the different mechanisms proposed so far is potentially applicable to specific ecosystems, a universally accepted theory for explaining plankton diversity in natural waters is still an unachieved goal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thermal Lens Spectrometry has traditionally been carried out in the single-beam and the mode-mismatched dual-beam configurations. Recently, a much more sensitive dual-beam TL setup was developed, where the probe beam is expanded and collimated. This feature optimizes Thermal Lens (TL) signal and allows the use of thicker samples, further improving the sensitivity. In this paper, we have made comparisons between the conventional and optimized TL configurations, and presented applications such as measurements of very low absorptions and concentrations in water and Cr(III) aqueous solution in the UV-vis range. For pure water we found linear absorption coefficients as low as the Raman scattering one due to the stretching vibrational modes of OH group. The detection limit was estimated 1 x 10(-6) cm(-1) with a 180-mW excitation power using a 100-mm cell length. This sensitivity is very high, considering that water has a photothermal enhancement factor similar to 33 times smaller than CCl(4), for example. For Cr(III) species in aqueous solution, the limit of detection (LOD) was estimated in similar to 40 ng mL(-1) at 514 nm, or similar to 10ng mL(-1) at 405 nm, which is similar to 30 times smaller than the LOD achieved with conventional transmission techniques. The more recent TL configuration is very attractive to obtain absorption spectra, since the result does not depend critically on the beam parameters, unlike the other configurations. The main drawbacks of this optimized TL configuration are the longer acquisition time and the need for larger samples. (C) 2011 Published by Elsevier B.V.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 mu L s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), mu A) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): ip = (-20.5 +/- 0.3) Cparaquat -(0.02 +/- 0.03). The limits of detection and quantification were 2.0 and 7.0 mu g L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.