999 resultados para MR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bicycle ergometer is a scientific device used by exercise physiologists which attempts to mimic on-road cycling characteristics such as foot technique, EMG activity, VO2, VCO2 and rider cardiology in a laboratory environment. Presently there are no known useful scientific ergometers that mimic these characteristics and are able to provide a satisfactory controlled resistance that is independent of speed. Previous research has suggested the use of a Magneto-Rheological (MR) Fluid as part of the ergometer design, as when used in a rotary brake application it is able to be controlled electronically to increase resistance instantly and independent of speed. In the target application, MR fluids are subject to immense tribological wear and temperature during viscous shearing, and will eventually show some degree of deterioration which is usually manifested as an increase in off-state viscosity. It is not known exactly how the fluid fails, however the amount of deterioration is related to the shear rate, temperature and duration and directly related to the power dissipation. Currently, there is very little literature that investigates the flow and thermal characteristics of MR fluid tribology using CFD. In this paper, we present initial work that aims to improve understanding of MR fluid wear via CFD modelling using Fluent, and results from the model are compared with those obtained from a experimental test rig of an MR fluid-based bicycle ergometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Tide Lords series of fantasy novels set out to examine the issue of immortality. Its purpose was to look at the desirability of immortality, specifically why people actively seek it. It was meant to examine the practicality of immortality, specifically — having got there, what does one do to pass the time with eternity to fill? I also wished to examine the notion of true immortality — immortals who could not be killed. What I did not anticipate when embarking upon this series, and what did not become apparent until after the series had been sold to two major publishing houses in Australia and the US, was the strength of the immortality tropes. This series was intended to fly in the face of these tropes, but confronted with the reality of such a work, the Australian publishers baulked at the ideas presented, requesting the series be re-written with the tropes taken into consideration. They wanted immortals who could die, mortals who wanted to be immortal. And a hero with a sense of humour. This exegesis aims to explore where these tropes originated. It will also discuss the ways I negotiated a way around the tropes, and was eventually able to please the publishers by appearing to adhere to the tropes, while still staying true to the story I wanted to tell. As such, this discussion is, in part, an analysis of how an author negotiates the tensions around writing within a genre while trying to innovate within it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magneto-rheological (MR) fluid damper is a semi-active control device that has recently received more attention by the vibration control community. But inherent nonlinear hysteresis character of magneto-rheological fluid dampers is one of the challenging aspects for utilizing this device to achieve high system performance. So the development of accurate model is necessary to take the advantage their unique characteristics. Research by others [3] has shown that a system of nonlinear differential equations can successfully be used to describe the hysteresis behavior of the MR damper. The focus of this paper is to develop an alternative method for modeling a damper in the form of centre average fuzzy interference system, where back propagation learning rules are used to adjust the weight of network. The inputs for the model are used from the experimental data. The resulting fuzzy interference system is satisfactorily represents the behavior of the MR fluid damper with reduced computational requirements. Use of the neuro-fuzzy model increases the feasibility of real time simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the analysis of medical images for computer-aided diagnosis and therapy, segmentation is often required as a preliminary step. Medical image segmentation is a complex and challenging task due to the complex nature of the images. The brain has a particularly complicated structure and its precise segmentation is very important for detecting tumors, edema, and necrotic tissues in order to prescribe appropriate therapy. Magnetic Resonance Imaging is an important diagnostic imaging technique utilized for early detection of abnormal changes in tissues and organs. It possesses good contrast resolution for different tissues and is, thus, preferred over Computerized Tomography for brain study. Therefore, the majority of research in medical image segmentation concerns MR images. As the core juncture of this research a set of MR images have been segmented using standard image segmentation techniques to isolate a brain tumor from the other regions of the brain. Subsequently the resultant images from the different segmentation techniques were compared with each other and analyzed by professional radiologists to find the segmentation technique which is the most accurate. Experimental results show that the Otsu’s thresholding method is the most suitable image segmentation method to segment a brain tumor from a Magnetic Resonance Image.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A magneto-rheological (MR) fluid damper is a semi-active control device that has recently begun to receive more attention in the vibration control community. However, the inherent nonlinear nature of the MR fluid damper makes it challenging to use this device to achieve high damping control system performance. Therefore the development of an accurate modeling method for a MR fluid damper is necessary to take advantage of its unique characteristics. Our goal was to develop an alternative method for modeling a MR fluid damper by using a self tuning fuzzy (STF) method based on neural technique. The behavior of the researched damper is directly estimated through a fuzzy mapping system. In order to improve the accuracy of the STF model, a back propagation and a gradient descent method are used to train online the fuzzy parameters to minimize the model error function. A series of simulations had been done to validate the effectiveness of the suggested modeling method when compared with the data measured from experiments on a test rig with a researched MR fluid damper. Finally, modeling results show that the proposed STF interference system trained online by using neural technique could describe well the behavior of the MR fluid damper without need of calculation time for generating the model parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twin studies offer the opportunity to determine the relative contribution of genes versus environment in traits of interest. Here, we investigate the extent to which variance in brain structure is reduced in monozygous twins with identical genetic make-up. We investigate whether using twins as compared to a control population reduces variability in a number of common magnetic resonance (MR) structural measures, and we investigate the location of areas under major genetic influences. This is fundamental to understanding the benefit of using twins in studies where structure is the phenotype of interest. Twenty-three pairs of healthy MZ twins were compared to matched control pairs. Volume, T2 and diffusion MR imaging were performed as well as spectroscopy (MRS). Images were compared using (i) global measures of standard deviation and effect size, (ii) voxel-based analysis of similarity and (iii) intra-pair correlation. Global measures indicated a consistent increase in structural similarity in twins. The voxel-based and correlation analyses indicated a widespread pattern of increased similarity in twin pairs, particularly in frontal and temporal regions. The areas of increased similarity were most widespread for the diffusion trace and least widespread for T2. MRS showed consistent reduction in metabolite variation that was significant in the temporal lobe N-acetylaspartate (NAA). This study has shown the distribution and magnitude of reduced variability in brain volume, diffusion, T2 and metabolites in twins. The data suggest that evaluation of twins discordant for disease is indeed a valid way to attribute genetic or environmental influences to observed abnormalities in patients since evidence is provided for the underlying assumption of decreased variability in twins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current gold standard for the design of orthopaedic implants is 3D models of long bones obtained using computed tomography (CT). However, high-resolution CT imaging involves high radiation exposure, which limits its use in healthy human volunteers. Magnetic resonance imaging (MRI) is an attractive alternative for the scanning of healthy human volunteers for research purposes. Current limitations of MRI include difficulties of tissue segmentation within joints and long scanning times. In this work, we explore the possibility of overcoming these limitations through the use of MRI scanners operating at a higher field strength. We quantitatively compare the quality of anatomical MR images of long bones obtained at 1.5 T and 3 T and optimise the scanning protocol of 3 T MRI. FLASH images of the right leg of five human volunteers acquired at 1.5 T and 3 T were compared in terms of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The comparison showed a relatively high CNR and SNR at 3 T for most regions of the femur and tibia, with the exception of the distal diaphyseal region of the femur and the mid diaphyseal region of the tibia. This was accompanied by an ~65% increase in the longitudinal spin relaxation time (T1) of the muscle at 3 T compared to 1.5 T. The results suggest that MRI at 3 T may be able to enhance the segmentability and potentially improve the accuracy of 3D anatomical models of long bones, compared to 1.5 T. We discuss how the total imaging times at 3 T can be kept short while maximising the CNR and SNR of the images obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The late eighteenth century witnessed the emergence of new technologies of subjectivity and of the literary. Most obviously, “the novel as a literary form appeared to embody and turn into an object the experience of life itself” (Park), and the novel genre came to both reflect and shape notions of interiority and subjectivity. In this same period, “A shift was taking place in the way people felt and thought about children and the accoutrements of childhood, including books and toys, were implicated in this change” (Lewis). In seeking to understand the relationships between media (e.g. books and toys), genres (e.g. novels and picture books), and modes of subjectivity, Marx’s influential theory of commodity fetishism, whereby “a definite social relation between men, that assumes, in their eyes, the fantastic form of a relation between things”, has served as a productive tool of analysis. The extent to which Marx’s account of commodity fetishism continues to be of use becomes clear when the corollaries between the late eighteenth-century emergence of novels and pictures books as technologies of subjectivity and the early twenty-first century emergence of e-readers and digital texts as technologies of subjectivity are considered. This paper considers the literary technology of Apple’s iPad (first launched in 2010) as a commodity fetish, and the circulation of “apps” as texts made available by and offered as justifications for, this fetish object. The iPad is both book and toy, but is never “only” either; it is arguably a new technology of subjectivity which incorporates but also destabilises categories of reading and playing such as those made familiar by earlier technologies of literature and the self. The particular focus of this paper is on the multimodal versions (app, film, and picture book) of The Fantastic Flying Books of Mr. Morris Lessmore, which are understood here as a narrativisation of commodity fetishism, subjectivity, and the act of reading itself.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In light of the time available today, I will limit my comments to addressing that aspect of Professor Fletcher’s paper in which he refers to the 2012 report he co-authored with Professor Wessels of the Netherlands for the American Law Institute (ALI) and the International Insolvency Institute (III) on Transnational Insolvency: Global Principles for Cooperation in International Insolvency Cases. I will comment on the potential benefits for Australian courts as well as insolvency administrators and their advisers in referring to the ALI-III Report - in light of Australia’s adoption of the UNCITRAL Model Law. In so doing, I would like to acknowledge the support of the Australian Academy of Law, under the leadership of The Hon Dr Kevin Lindgren for the research project underpinning these comments, as well as to acknowledge the contributions of my colleagues Associate Professor Sheryl Jackson and Mark Wellard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interview with Mr Kaan Ozgun, PhD Candidate at Queensland University of Technology, about clean energy in Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the Mr. 72,000 type IV collagenase (matrix metalloproteinase 2) has been implicated in a variety of normal and pathogenic processes, its activation mechanism in vivo is unclear. We have found that fibroblasts from normal and neoplastic human breast, as well as the sarcomatous human Hs578T and HT1080 cell lines, activate endogenous matrix metalloprotease 2 when cultured on type I collagen gels, but not on plastic, fibronectin, collagen IV, gelatin, matrigel, or basement membrane-like HR9 cell matrix. This activation is monitored by the zymographic detection of Mr 59,000 and/or Mr 62,000 species, requires 2-3 days of culture on vitrogen to manifest, is cycloheximide inhibitable, and correlates with an arborized morphology. A similar activation pattern was seen in these cells in response to Concanavalin A but not transforming growth factor β or 12-O-tetradecanoylphorbol-13-acetate. The interstitial matrix may thus play an important role in regulating matrix degradation in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiographs are commonly used to assess articular reduction of the distal tibia (pilon) fractures postoperatively, but may reveal malreductions inaccurately. While Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) are potential 3D alternatives they generate metal-related artifacts. This study aims to quantify the artifact size from orthopaedic screws using CT, 1.5T and 3T MRI data. Three screws were inserted into one intact human cadaver ankle specimen proximal to and along the distal articular surface, then CT, 1.5T and 3T MRI scanned. Four types of screws were investigated: titanium alloy (TA), stainless steel (SS) (Ø = 3.5 mm), cannulated TA (CTA) and cannulated SS (CSS)(Ø = 4.0 mm, Ø empty core = 2.6 mm). 3D artifact models were reconstructed using adaptive thresholding. The artifact size was measured by calculating the perpendicular distance from the central screw axis to the boundary of the artifact in four anatomical directions with respect to the distal tibia. The artifact sizes (in the order of TA, SS, CTA and CSS) from CT were 2.0 mm, 2.6 mm, 1.6 mm and 2.0 mm; from 1.5T MRI they were 3.7 mm, 10.9 mm, 2.9 mm, and 9 mm; and 3T MRI they were 4.4 mm, 15.3 mm, 3.8 mm, and 11.6 mm respectively. Therefore, CT can be used as long as the screws are at a safe distance of about 2 mm from the articular surface. MRI can be used if the screws are at least 3 mm away from the articular surface except SS and CSS. Artifacts from steel screws were too large thus obstructed the pilon from being visualised in MRI. Significant differences (P < 0.05) were found in the size of artifacts between all imaging modalities, screw types and material types, except 1.5T versus 3T MRI for the SS screws (P = 0.063). CTA screws near the joint surface can improve postoperative assessment in CT and MRI. MRI presents a favourable non-ionising alternative when using titanium hardware. Since these factors may influence the quality of postoperative assessment, potential improvements in operative techniques should be considered.