972 resultados para MAXILLARY FRACTURES


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated different techniques for surgically assisted rapid maxillary expansion (SARME) according to the type of transverse maxillary deficiency using computed tomography (CT). Six adult patients with bilateral transverse maxillary deficiencies underwent SARME. the patients were equally divided into three groups: Group I, maxillary atresia in both the anterior and posterior regions; Group II, greater maxillary atresia in the anterior region; and Group ill, increased maxillary atresia in the posterior region. in Group I, a subtotal Le Fort I osteotomy was used. in Group II, a subtotal Le Fort I osteotomy was used without pterygomaxillary suture disjunction. in Group III, a subtotal Le Fort I osteotomy was used with pterygomaxillary suture disjunction and fixation of the anterior nasal spine with steel wire. the midpalatal suture opening was evaluated preoperatively and immediately after the activation period using CT. for Group I, the opening occurred parallel to midpalatal suture; for Group II, the opening comprised a V-shape with a vertex on the posterior nasal spine; and for Group III, the opening comprised a V-shape with a vertex at the anterior nasal spine. the conclusion was that the SARME technique should be individualized according to the type of transverse maxillary deficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This PhD thesis describes work carried out on investigation of various interventions with the aim to optimise the anaesthetic management of patients scheduled to undergo operative fixation of hip fractures. We analysed the perioperative effects of continuous femoral nerve block, single preoperative dose of i.v. dexamethasone, the intention to deposit local anaesthetic in different locations around the femoral nerve during ultrasound guided femoral nerve block, continuous spinal anaesthesia and peri-surgical site infiltration with local anaesthetic after surgical fixation of hip fractures. Continuous femoral nerve block provided more effective preoperative analgesia six hours after the insertion of the perineural catheter compared to a standard opiate-based regimen in patients undergoing operative fixation of fractured hip. A single low dose of preoperative dexamethasone in the intervention group decreased pain scores by 75% six hours after the surgery. Both interventions had no major effect on the functional recovery in the first year after the surgical fixation of fractured hip. The results of the ultrasound guided femoral nerve block trial showed no clinical advantage of intending to deposit local anaesthetic circumferentially during performing femoral nerve block. Using the Dixon and Massey’s “up- and-down” method, we demonstrated that intrathecal 0.26 ml of 0.5% bupivacaine provided adequate surgical anaesthesia within 15 minutes in 50% of patients undergoing operative fixation of hip fracture. Finally, we demonstrated that local anaesthetic infiltration had no effect on pain scores 12 hours after the surgical fixation of fractured neck of femur. In addition to this original body of work, a review article was published on femoral nerve block highlighting the use of ultrasound guidance. In conclusion, the results of this thesis offer an insight into interventions aimed at optimising perioperative analgesia in patients scheduled to undergo operative fixation of hip fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare the incidence and timing of bone fractures in postmenopausal women treated with 5 years of adjuvant tamoxifen or letrozole for endocrine-responsive early breast cancer in the Breast International Group (BIG) 1-98 trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In patients with myelomeningocele (MMC), a high number of fractures occur in the paralyzed extremities, affecting mobility and independence. The aims of this retrospective cross-sectional study are to determine the frequency of fractures in our patient cohort and to identify trends and risk factors relevant for such fractures. MATERIALS AND METHODS: Between March 1988 and June 2005, 862 patients with MMC were treated at our hospital. The medical records, surgery reports, and X-rays from these patients were evaluated. RESULTS: During the study period, 11% of the patients (n = 92) suffered one or more fractures. Risk analysis showed that patients with MMC and thoracic-level paralysis had a sixfold higher risk of fracture compared with those with sacral-level paralysis. Femoral-neck z-scores measured by dual-energy X-ray absorptiometry (DEXA) differed significantly according to the level of neurological impairment, with lower z-scores in children with a higher level of lesion. Furthermore, the rate of epiphyseal separation increased noticeably after cast immobilization. Mainly patients who could walk relatively well were affected. CONCLUSIONS: Patients with thoracic-level paralysis represent a group with high fracture risk. According to these results, fracture and epiphyseal injury in patients with MMC should be treated by plaster immobilization. The duration of immobilization should be kept to a minimum (<4 weeks) because of increased risk of secondary fractures. Alternatively, patients with refractures can be treated by surgery, when nonoperative treatment has failed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular dynamics has been employed to model the fracture of a twodimensional triangular atomic lattice. The N-body Sutton-Chen potential developed for fcc metals and its extended version (Rafii-Tabar and Sutton) for fcc random binary alloys were used for the interatomic interactions. It is shown that at low temperatures cleavage fractures can occur in both an elemental metal and an alloy. At elevated temperatures the nucleation of dislocations is shown to cause a brittle-to-ductile transition. For the brittle crack propagation in the elemental metal, crack propagation speeds have been computed for different stress rates, and a crack instability found to exist as the speed reaches a critical value of about 32% of the Rayleigh wave speed. For the random alloy, we find that the dislocation movement can be affected by the distorted lattice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular dynamics has been employed to model the fracture of a two dimensional triangular atomic lattice. The N-body Sutton-Chen potential developed for fcc metals and its extended version (Rafii-Tabar and Sutton) for fcc random binary alloys were used for the interatomic interactions. It is shown that at low temperatures cleavage fractures can occur in both an elemental metal and an alloy. At elevated temperatures the nucleation of dislocations is shown to cause a brittle-to-ductile transition. For the brittle crack propagation in the elemental metal, crack propagation speeds have been computed for different stress rates, and a crack instability found to exist as the speed reaches a critical value of about 32% of the Rayleigh wave speed. For the random alloy, we find that the dislocation movement can be affected by the distorted lattice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess 3-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques to see whether doses to critical structures could be reduced while maintaining planning target volume (PTV) coverage in patients receiving conventional radiotherapy (RT) for carcinoma of the maxillary sinus because of the risk of radiation-induced complications, particularly visual loss. Six patients who had recently received conventional RT for carcinoma of the maxillary sinus were studied. Conventional RT, 3D-CRT, and step-and-shoot IMRT plans were prepared using the same 2-field arrangement. The effect of reducing the number of segments in the IMRT beams was investigated. 3D-CRT and IMRT reduced the brain and ipsilateral parotid gland doses compared with the conventional plans. IMRT reduced doses to both optic nerves; for the contralateral optic nerve, 15-segment IMRT plans delivered an average maximal dose of 56.4 Gy (range 53.9–59.3) compared with 65.7 Gy (range 65.3–65.9) and 64.2 Gy (range 61.4–65.6) for conventional RT and 3D-CRT, respectively. IMRT also gave improved PTV homogeneity and improved coverage, with an average of 8.5% (range 7.0–11.7%) of the volume receiving