887 resultados para Lasers in surgery


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The purpose of this study was to investigate the rat skin penetration abilities of two commercially available low-level laser therapy (LLLT) devices during 150 sec of irradiation. Background data: Effective LLLT irradiation typically lasts from 20 sec up to a few minutes, but the LLLT time-profiles for skin penetration of light energy have not yet been investigated. Materials and methods: Sixty-two skin flaps overlaying rat's gastrocnemius muscles were harvested and immediately irradiated with LLLT devices. Irradiation was performed either with a 810 nm, 200mW continuous wave laser, or with a 904 nm, 60mW superpulsed laser, and the amount of penetrating light energy was measured by an optical power meter and registered at seven time points (range, 1-150 sec). Results: With the continuous wave 810nm laser probe in skin contact, the amount of penetrating light energy was stable at similar to 20% (SEM +/- 0.6) of the initial optical output during 150 sec irradiation. However, irradiation with the superpulsed 904 nm, 60mW laser showed a linear increase in penetrating energy from 38% (SEM +/- 1.4) to 58% (SEM +/- 3.5) during 150 sec of exposure. The skin penetration abilities were significantly different (p < 0.01) between the two lasers at all measured time points. Conclusions: LLLT irradiation through rat skin leaves sufficient subdermal light energy to influence pathological processes and tissue repair. The finding that superpulsed 904nm LLLT light energy penetrates 2-3 easier through the rat skin barrier than 810nm continuous wave LLLT, corresponds well with results of LLLT dose analyses in systematic reviews of LLLT in musculoskeletal disorders. This may explain why the differentiation between these laser types has been needed in the clinical dosage recommendations of World Association for Laser Therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Objectives Laser tissue repair usually relies on hemoderivate protein solders, based on serum albumin. These solders have intrinsic limitations that impair their widespread use, such as limited tensile strength of repaired tissue, poor solder solubility, and brittleness prior to laser denaturation. Furthermore, the required activation temperature of albumin solders (between 65 and 70°C) can induce significant thermal damage to tissue. In this study, we report on the design of a new polysaccharide adhesive for tissue repair that overcomes some of the shortcomings of traditional solders. Study Design/Materials and Methods Flexible and insoluble strips of chitosan adhesive (elastic modulus ~6.8 Mpa, surface area ~34 mm2, thickness ~20 µm) were bonded onto rectangular sections of sheep intestine using a diode laser (continuous mode, 120 ± 10 mW, = λ 808 nm) through a multimode optical fiber with an irradiance of ~15 W/cm2. The adhesive was based on chitosan and also included indocyanin green dye (IG). The temperature between tissue and adhesive was measured using a small thermocouple (diameter ~0.25 mm) during laser irradiation. The repaired tissue was tested for tensile strength by a calibrated tensiometer. Murine fibroblasts were cultured in extracted media from chitosan adhesive to assess cytotoxicity via cell growth inhibition in a 48 hours period. Results Chitosan adhesive successfully repaired intestine tissue, achieving a tensile strength of 14.7 ± 4.7 kPa (mean ± SD, n = 30) at a temperature of 60-65°C. Media extracted from chitosan adhesive showed negligible toxicity to fibroblast cells under the culture conditions examined here. Conclusion A novel chitosan-based adhesive has been developed, which is insoluble, flexible, and adheres firmly to tissue upon infrared laser activation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Failure to convey time-critical information to team members during surgery diminishes members’ perception of the dynamic information relevant to their task, and compromises shared situational awareness. This research reports the dialog around clinical decisions made by team members in the time-pressured and high-risk context of surgery, and the impact of these communications on shared situational awareness. Methods Fieldwork methods were used to capture the dynamic integration of individual and situational elements in surgery that provided the backdrop for clinical decisions. Nineteen semi structured interviews were performed with 24 participants from anaesthesia, surgery, and nursing in the operating rooms of a large metropolitan hospital in Queensland, Australia. Thematic analysis was used. Results: The domain “coordinating decisions in surgery” was generated from textual data. Within this domain, three themes illustrated the dialog of clinical decisions, i.e., synchronizing and strategizing actions, sharing local knowledge, and planning contingency decisions based on priority. Conclusion Strategies used to convey decisions that enhanced shared situational awareness included the use of “self-talk”, closed-loop communications, and “overhearing” conversations that occurred at the operating table. Behaviours’ that compromised a team’s shared situational awareness included tunnelling and fixating on one aspect of the situation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As a key department within a healthcare organisation, the operating room is a hazardous environment, where the consequences of errors are high, despite the relatively low rates of occurrence. Team performance in surgery is increasingly being considered crucial for a culture of safety. The aim of this study was to describe team communication and the ways it fostered or threatened safety culture in surgery. Ethnography was used, and involved a 6-month fieldwork period of observation and 19 interviews with 24 informants from nursing, anaesthesia and surgery. Data were collected during 2009 in the operating rooms of a tertiary care facility in Queensland, Australia. Through analysis of the textual data, three themes that exemplified teamwork culture in surgery were generated: ‘‘building shared understandings through open communication’’; ‘‘managing contextual stressors in a hierarchical environment’’ and ‘‘intermittent membership influences team performance’’. In creating a safety culture in a healthcare organisation, a team’s optimal performance relies on the open discussion of teamwork and team expectation, and significantly depends on how the organisational culture promotes such discussions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has been 21 years since the decision in Rogers v Whitaker and the legal principles concerning informed consent and liability for negligence are still strongly grounded in this landmark High Court decision. This paper considers more recent developments in the law concerning the failure to disclose inherent risks in medical procedures, focusing on the decision in Wallace v Kam [2013] HCA 19. In this case, the appellant underwent a surgical procedure that carried a number of risks. The surgery itself was not performed in a sub-standard way, but the surgeon failed to disclose two risks to the patient, a failure that constituted a breach of the surgeon’s duty of care in negligence. One of the undisclosed risks was considered to be less serious than the other, and this lesser risk eventuated causing injury to the appellant. The more serious risk did not eventuate, but the appellant argued that if the more serious risk had been disclosed, he would have avoided his injuries completely because he would have refused to undergo the procedure. Liability was disputed by the surgeon, with particular reference to causation principles. The High Court of Australia held that the appellant should not be compensated for harm that resulted from a risk he would have been willing to run. We examine the policy reasons underpinning the law of negligence in this specific context and consider some of the issues raised by this unusual case. We question whether some of the judicial reasoning adopted in this case, represents a significant shift in traditional causation principles.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advanced waveguide lasers, operating both in continuous wave and pulsed regimes, have been realized in an active phosphate glass by direct writing with femtosecond laser pulses. Stable single mode operation was obtained; the laser provided more than 50 m W in single longitudinal and transverse mode operation with 21% slope efficiency. Furthermore, by combining a high gain waveguide and an innovated fiber-pigtailed saturable absorber based on carbon nanotubes, a mode-locked ring laser providing transform limited 1.6 ps pulses was demonstrated. © 2007 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The polarization of vertical-cavity surface-emitting laser (VCSEL) can be controlled by electro-optic birefringence. We calculated the birefringence resulted from external electric field which was imposed on the top DBR of VCSEL by assuming that the two polarization modes were in the same place of the gain spectra in the absence of electric field beginning. By modifying SFM, the affection of the electric field strength on the polarization switching currents between the two polarization modes had been shown.

Relevância:

100.00% 100.00%

Publicador: