970 resultados para Laryngeal Mask Airway


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: During general anesthesia, nitrous oxide (N2O) diffuses rapidly into the air-filled laryngeal mask airway (LMA) cuff, increasing intracuff pressure. There is no clear correlation between LMA intracuff pressure and pressure on the pharynx. We have studied the effects of high LMA intracuff pressures secondary to N2O on the pharyngeal mucosa of dogs.Methods: Sixteen mongrel dogs were randomly allocated to two groups: G1 (intracuff volume, 30 mL; n = 8) breathed a mixture of O-2 (1 L.min(-1)) and air (1 L.min(-1)) and G2 (intracuff volume, 30 mL; n=8) a mixture of O-2 (1 L.min(-1)) and N2O (1 L.min(-1)). Anesthesia was induced and maintained with pentobarbitone. LMA cuff pressure was measured at zero (control), 30, 60, 90 and 120 min after #4 LMA insertion. The dogs were sacrificed, and biopsy specimens from seven predetermined areas of the pharynx in contact with the LMA cuff were collected for light (LM) and scanning electron microscopic (SEM) examination by a blinded observer.Results: LMA intracuff pressure decreased with time in G1 (P < 0.001) and increased in G2 (P < 0.001). There was a significant difference between the groups (P < 0.001). In both groups, the LM study showed a normal epithelium covering the pharyngeal mucosa and mild congestion in the subepithelial layer There were no differences between the groups (P > 0.10) or among the areas sampled (P > 0.05). In both groups, the SEM study showed a normal pharyngeal mucosa with mild superficial desquamation. Few specimens in G1 and G2 showed more intense epithelial desquamation.Conclusion: High LMA intracuff pressures produced by N2O do not increase pharyngeal mucosal injury in dogs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Avaliar as alterações morfológicas no epitélio traqueal de cães expostos à inalação de gases pouco condicionados, sob ventilação com tubo traqueal (TT) ou máscara laríngea (ML). MÉTODOS: Doze cães adultos foram divididos aleatoriamente em dois grupos: grupo TT (n-6) e grupo ML (n-6), submetidos à anestesia venosa e ventilação mecânica, em sistema sem reabsorção de CO2. Foram registrados parâmetros hemodinâmicos e ventilatórios, temperatura timpânica, temperatura, umidade relativa e absoluta do ar ambiente e dos gases inalados durante 3 horas. Ao término do experimento, os animais foram submetidos a eutanásia e realizadas biópsias ao longo do segmento traqueal para estudo morfológico. Três cães saudáveis foram utilizados para controle morfológico. RESULTADOS: A temperatura dos gases inalados manteve-se entre 24ºC e 26ºC, a umidade relativa entre 10% e 12%, e umidade absoluta entre 2 -3 mg H2O.L-1 sem diferença significativa entre os grupos. em ambos os grupos a análise histológica evidenciou processo inflamatório epitelial e congestão no córion, e a microscopia eletrônica de varredura mostrou agrupamento e desorganização ciliar. A microscopia eletrônica de transmissão detectou maiores alterações no grupo TT do que no ML, como alargamento das junções intercelulares, desorientação ciliar, vacuolização citoplasmática, alterações nucleares como pcinose e condensação da cromatina. CONCLUSÃO: A máscara laríngea determinou alterações menos pronunciadas no epitélio traqueal de cães expostos à inalação de gases pouco condicionados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of increased of laryngeal mask airway (LMA) intracuff pressures on the laryngopharyngeal mucosa. Study Design: Animal model. Methods: Sixteen mixed-breed dogs were randomly allocated to two groups, G1 (intracuff volume, 30 mL; n = 8) and G2 (intracuff volume, 54 mt; n = 8), to produce, respectively, high or very high intracuff pressures. Anesthesia was induced and maintained with pentobarbital. Intracuff pressures were measured immediately after insertion and inflation of a No. 4 laryngeal mask airway (LMA) and 30, 60, 90, and 120 minutes thereafter. The dogs were euthanized, and biopsy specimens from eight predetermined areas of the laryngopharynx in contact with LMA cuff were collected for light microscopic (LM) and scanning electron microscopic (SEM) examination. Results: Initial LMA cuff inflation in G1 and G2 resulted in intracuff pressures of 119 mm Hg +/- 4 mm Hg and 235 mm Hg +/- 13 mm Hg, respectively. Over a 2-hour period, the intracuff pressure decreased significantly in G1 (P < .001) and G2 (P < .01), and there was a significant difference between the groups over time (P < .001). The LM study of laryngopharyngeal mucosa in both groups showed mild congestion in the subepithelial layer. There were no differences between the groups (P > .10) or among the areas sampled (P > .10). In some areas of G2, the SEM study showed epithelial desquamation that was more intense than that in GI. Conclusions: the increase in LMA intracuff pressure caused only mild alterations in the laryngopharyngeal mucosa of the dog.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective - To investigate the use of the laryngeal mask airway (LMA) in dogs. Study Design - Prospective experimental study. Animals - Eight healthy adult mixed breed dogs weighing from 15 to 20 kg. Methods - The dogs were anesthetized with intravenous pentobarbital. An LMA was introduced after the induction of anesthesia and 1 L/min O2 plus 1 L/min air was delivered using a circle anesthetic system. Respiratory rate, tidal volume, arterial O2 saturation (pulse oximetry), end tidal CO2, inspired fraction of O2, pulse rate, and mean arterial blood pressure were measured after the insertion of the LMA and 30, 60, 90, and 120 minutes afterwards. Results - There were no changes in respiratory rate, tidal volume, arterial O2 saturation, and pulse rate during anesthesia. End tidal CO2 decreased significantly by the end of anesthesia and ventilation appeared satisfactory. Conclusions - An LMA appeared to be an alternative option to maintain the patency of the airway in dogs. Clinical Relevance - This device may allow safe maintenance of an airway in dogs when intubation is difficult or when it interferes with the procedure (eg, cervical myelography). ©Copyright 1999 by The American College of Veterinary Surgeons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

After marked airway obstruction with laryngeal mask (LM) placement in neonate piglets, anatomical observations in cadavers revealed a large epiglottis advancing markedly over the soft palate. CT imaging in vivo confirmed that the LM pushes the epiglottis caudally thereby obstructing the larynx. As a new approach, in 20 piglets a flexible PVC bougie placed under laryngoscopy was used to guide the LM to the correct position at the larynx. Placement of the bougie was easy and the LM was positioned successfully in all piglets at first attempt. In 14 piglets, the epiglottis was positioned dorsal to the soft palate before LM insertion and had to be pushed downwards to advance the bougie. In case of failure of LM placement with potential airway obstruction, the use of a bougie to guide the LM over the epiglottis was simple, rapid, and improved the success rate without complication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When using the laryngeal tube and the intubating laryngeal mask airway (ILMA), the medium-size (maximum volume 1100 ml) versus adult (maximum volume 1500 ml) self-inflating bags resulted in significantly lower lung tidal volumes. No gastric inflation occurred when using both devices with either ventilation bag. The newly developed medium-size self-inflating bag may be an option to further reduce the risk of gastric inflation while maintaining sufficient lung ventilation. Both the ILMA and laryngeal tube proved to be valid alternatives for emergency airway management in the experimental model used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and objective: There are no data about the influence of anaesthetics on cardiovascular variables during pressure support ventilation of the lungs through the laryngeal mask airway. We compared propofol, sevoflurane and isoflurane for maintenance of anaesthesia with the ProSeal (R) laryngeal mask airway during pressure support ventilation. Methods: Sixty healthy adults undergoing peripheral musculo-skeletal surgery were randomized for maintenance with sevoflurane end-tidal 29%, isoflurane end-tidal 1.1% or propofol 6 mg kg(-1) h(-1) in oxygen 33% and air. Pressure support ventilation comprised positive end-expiratory pressure set at 5 cmH(2)O, and pressure support set 5 cmH(2)O above positive end-expiratory pressure. Pressure support was initiated when inspiration produced a 2 cmH(2)O reduction in airway pressure. A blinded observer recorded cardiorespiratory variables (heart rate, mean blood pressure, oxygen saturation, air-way occlusion pressure, respiratory rate, expired tidal volume, expired minute volume and end-tidal CO2), adverse events and emergence times. Results: Respiratory rate and minute volume were 10-21% lower, and end-tidal CO2 6-11% higher with the propofol group compared with the sevoflurane or isoflurane groups, but otherwise cardiorespiratory variables were similar among groups. No adverse events occurred in any group. Emergence times were longer with the propofol group compared with the sevoflurane or isoflurane groups (10 vs. 7 vs. 7 min). Conclusion: Lung ventilation is less effective and emergence times are longer with propofol than sevoflurane or isoflurane for maintenance of anaesthesia during pressure support ventilation with the ProSeal (R) laryngeal mask airway. However, these differences are small and of doubtful clinical importance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Laryngeal Mask Airway is a reusable device for maintaining the patency of a patient's airway during general anaesthesia. The device can be reused after it has been cleaned and sterilized. Protein contamination of medical instruments is a concern and has been found to occur despite standard sterilization techniques. The reason for the concern relates to the possibility of the transmission of prions and the risk of developing a neurodegenerative disorder such as Creutzveldt-Jacob disease. The purpose of this study was to quantify the amount of protein contamination that occurs, and to relate this to the number of times the Laryngeal Mask Airway has been used. Fifty previously used Classic Laryngeal Masks were collected after routine sterilization and packaging. The devices were immersed in protein detecting stain and then visual inspection performed to assess the degree and distribution of the staining. The researcher was blinded to the number of times the Laryngeal Mask Airway had been used. Linear regression analysis of the degrees of staining of the airway revealed that protein contamination occurs after the first use of the device and this increases with each subsequent use. This finding highlights the concern that the currently used cleaning and sterilization methods do not prevent the accumulation of proteinaceous material on Laryngeal Mask Airways. Consideration should be given to the search for more efficient cleaning and sterilization techniques or the use of disposable devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To compare the cardiorespiratory effects and incidence of gastroesophageal reflux with the use of a laryngeal mask airway (LMA) or endotracheal tube (ET) in anesthetized cats during spontaneous (SV) or controlled ventilation (CV).Study design Prospective randomized experimental trial.Animals Thirty-two adult crossbred cats, weighing 2.7 +/- 0.4 kg.Methods the cats were sedated with intramuscular (IM) methotrimeprazine (0.5 mg kg(-1)) and buprenorphine (0.005 mg kg(-1)), followed 30 minutes later by induction of anesthesia with intravenous (IV) thiopental (12.5-20 mg kg(-1)). An ET was used in 16 cats and an LMA in the remaining 16 animals. Anesthesia was maintained with 0.5 minimum alveolar concentration (0.6%) of halothane in oxygen using a Mapleson D breathing system. Cats in both groups were further divided into two equal groups (n = 8), undergoing either SV or CV. Neuromuscular blockade with pancuronium (0.06 mg kg(-1)) was used to facilitate CV. Heart and respiratory rates, direct arterial blood pressure, capnometry (PE'CO2) and arterial blood gases were measured. Gastric reflux and possible aspiration was investigated by intragastric administration of 5 mL of radiographic contrast immediately after induction of anesthesia. Cervical and thoracic radiographs were taken at the end of anesthesia. Data were analyzed using ANOVA followed by Student-Newman-Keuls, Kruskal-Wallis or Friedman test where appropriate.Results Values for PaCO2 and PE'CO2 were higher in spontaneously breathing cats with the LMA when compared with other groups. Values of PaO2 and hemoglobin oxygen saturation did not differ between groups. Gastroesophageal reflux occurred in four of eight and two of eight cats undergoing CV with ET or LMA, respectively. There was no tracheal or pulmonary aspiration in any cases.Conclusions and clinical relevance the use of an LMA may be used as an alternative to endotracheal intubation in anesthetized cats. Although aspiration was not observed, gastric reflux may occur in mechanically ventilated animals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The single-use supraglottic airway devices LMA-Supreme (LMA-S; Laryngeal Mask Company, Henley-on-Thames, United Kingdom) and i-gel (Intersurgical Ltd, Wokingham, Berkshire, United Kingdom) have a second tube for gastric tube insertion. Only the LMA-S has an inflatable cuff. They have the same clinical indications and might be useful for difficult airway management. This prospective, crossover, randomized controlled trial was performed in a simulated difficult airway scenario using an extrication collar limiting mouth opening and neck movement. METHODS: Sixty patients were included. Both devices were placed in random order in each patient. Primary outcome was overall success rate. Other measurements were time to successful ventilation, airway leak pressure, fiberoptic glottic view, and adverse events. RESULTS: Success rate for the LMA-S was 95% versus 93% for the i-gel (P = 1.000). LMA-S needed shorter insertion time (34 +/- 12 s vs. 42 +/- 23 s, P = 0.024). Tidal volumes and airway leak pressure were similar (LMA-S 26 +/- 8 cm H20; i-gel 27 +/- 9 cm H20; P = 0.441). Fiberoptic view through the i-gel showed less epiglottic downfolding. Overall agreement in insertion outcome was 54 (successes) and 1 (failure) or 55 (92%) of 60 patients. The difference in success rate was 1.7% (95% CI -11.3% to 7.6%). CONCLUSIONS: Both airway devices had similar insertion success and clinical performance in the simulated difficult airway situation. The authors found less epiglottic downfolding and better fiberoptic view but longer insertion time with the i-gel. Our study shows that both devices are feasible for emergency airway management in patients with reduced neck movement and limited mouth opening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available. Therefore, we performed this prospective randomized controlled trial to compare the success rate of blind tracheal intubation with a Magill PVC tube through the i-gel™ with intubation using an sILMA™ PVC tube through the single-use intubating laryngeal mask airway (sILMA™).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This prospective, randomized, controlled trial compares the performance of the pediatric i-gel (Intersurgical Ltd., Wokingham, United Kingdom) with the Ambu AuraOnce laryngeal mask (Ambu A/S, Ballerup, Denmark) in anesthetized and ventilated children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaluar si el Heliox reduce la resistencia en la vía aérea en niños y adolescentes con patología bronquial obstructiva que requieren ventilación mecánica. Materiales y Métodos: Estudio prospectivo observacional descriptivo en niños y adolescentes con patología bronquial obstructiva y ventilación mecánica con Fi02 ≤ 0,5. Medición de variables: resistencia, presión pico, presión media de la vía aérea, presión meseta, volumen corriente, autoPEEP, distensibilidad, PetCO2, ventilación de espacio muerto antes de inicio de heliox y a los 30 minutos, 2, 4, 6, 12, 18 y 24 horas y diariamente hasta suspenderlo por extubación o FiO2 > 0,5. Resultados: Resultados parciales, incluyó 9 pacientes encontrando descenso significativo de resistencia espiratoria a los 30 minutos (51,2 vs 32,3; p=0,0008 ), 2 horas ( 51,2 vs 33,4; p=0,0019) y 4 horas (51,2 vs 30,7; p=0,0012) así como de la resistencia inspiratoria a la hora 2 (48,6 vs 36,2; p = 0,013) y hora 4 (48,6 vs 30 ; p=0,004). Se observó tendencia al descenso de la PetCO2 que no fue significativa (52,3 vs 34,3: p=0,06). No se evidenció cambios en las variables; autoPEEP, presión pico, presión media de la vía aérea, distensibilidad, ventilación de espacio muerto, presión meseta y volumen corriente antes y después del inicio del Heliox. Conclusión: La ventilación mecánica con Heliox en niños con patología bronquial obstructiva parece ser que reduce de manera significativa la resistencia de la vía aérea, con tendencia al descenso de la PetC02. Se necesitan estudios prospectivos al menos observacionales analíticos que corroboren estos hallazgos.