990 resultados para Intra-aortic Balloon Pumping


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To report percutaneous fenestration of aortic dissection flaps to relieve distal ischemia using a novel intravascular ultrasound (IVUS)-guided fenestration device. CASE REPORTS: Two men (47 and 62 years of age) with aortic dissection and intermittent claudication had percutaneous ultrasound-guided fenestration performed under local anesthesia. Using an ipsilateral transfemoral approach, the intimal flap was punctured under real-time IVUS guidance using a needle-catheter combination through which a guidewire was placed across the dissection flap into the false lumen. The fenestration was achieved using balloon catheters of increasing diameter introduced over the guidewire. Stenting of the re-entry was performed in 1 patient to equalize pressure across the dissection membrane in both lumens. The procedures were performed successfully and without complications. In both patients, ankle-brachial indexes improved from 0.76 to 1.07 and from 0.8 to 1.1, respectively. Both patients were without claudication at the 3- and 6-month follow-up examination. CONCLUSION: Percutaneous intravascular ultrasound-guided fenestration and stenting at the level of the iliac artery in aortic dissection patients with claudication is a technically feasible and safe procedure and relieves symptoms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The indications for endovascular aortic aneurysm repair (EVAR) are mainly established in hostile abdomen, in patients with significant comorbidities which affect the general operability of the patient and, given the necessary infrastructure, also in ruptured aneurysm. Along to those, we present another possible indication in the presence of a kidney allograft in patients with aortic aneurysm. METHODS: Based on a case report of aorto-biiliac stent-graft repair of an infrarenal aortic aneurysm in a patient with renal allograft, a systematic review of the literature was performed of all similar cases concerning surgical therapy in this constellation. RESULTS: EVAR was performed using an aorto-biiliac system (Zenith) Trifab, COOK) in a 61-year-old male patient 11 years after heterotopic renal allotransplantation in the right iliac fossa. Preoperative renal function was normal. Because the donor renal artery was anastomosed to the recipient's external iliac artery the stent-graft was implanted from the left common femoral artery to minimize temporary allograft ischemia. The intra- and postoperative course was uneventful with a follow-up of presently 12 months. A primary type-II endoleak (retroleak from a lumbar artery) is being treated conservatively so far with embolization being a future option. At present there are 15 cases of EVAR in renal allograft patients that have been reported, all of them being successful. DISCUSSION: All data existing in the literature reported to date as well as our own experience justify the first choice of EVAR in morphologically suitable cases. One major advantage of EVAR in this constellation is the avoidance of aortic cross clamping which poses the graft at risk of ischemia. Long-term results will be most important for definite assessment of EVAR. However, contrast media application during the operation and for CT surveillance should be considered as a major disadvantage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whether or not there are molecular differences, at the intra- and extracellular level, between aortic dilatation in patients with bicuspid (BAV) and those with a tricuspid aortic valve (TAV) has remained controversial for years. We have performed 2-dimensional gel electrophoresis and mass spectrometry coupled with dephosphorylation and phosphostaining experiments to reveal and define protein alterations and the high abundant structural phosphoproteins in BAV compared to TAV aortic aneurysm samples. 2-D gel patterns showed a high correlation in protein expression between BAV and TAV specimens (n=10). Few proteins showed significant differences, among those a phosphorylated form of heat shock protein (HSP) 27 with significantly lower expression in BAV compared to TAV aortic samples (p=0.02). The phosphoprotein tracing revealed four different phosphoproteins including Rho GDP dissociation inhibitor 1, calponin 3, myosin regulatory light chain 2 and four differentially phosphorylated forms of HSP27. Levels of total HSP27 and dually phosphorylated HSP27 (S78/S82) were investigated in an extended patient cohort (n=15) using ELISA. Total HSP27 was significantly lower in BAV compared to TAV patients (p=0.03), with no correlation in levels of phospho-HSP27 (S78/S82) (p=0.4). Western blots analysis showed a trend towards lower levels of phospho-HSP27 (S78) in BAV patients (p=0.07). Immunohistochemical analysis revealed that differences in HSP27 occur in the cytoplasma of VSMC's and not extracellularly. Alterations in HSP27 may give early evidence for intracellular differences in aortic aneurysm of patients with BAV and TAV. Whether HSP27 and the defined phosphoproteins have a specific role in BAV associated aortic dilatation remains to be elucidated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To analyse our results of using a double arterial perfusion strategy to avoid lower body hypothermic circulatory arrest after extensive thoracic aortic surgery. METHODS We analysed the intra- and perioperative courses of 10 patients (median age 58 years, median logistic EuroSCORE 14.6) who underwent extensive thoracic aortic surgery with a double arterial perfusion strategy. The main goal of double arterial perfusion is to separate myocardial and supra-aortic from systemic perfusion. Aortic repair starts at the most distal level of the descending aorta, followed by reinsertion of the supra-aortic vessels, and ends with completion of the proximal anastomosis or by any kind of root repair as needed. RESULTS Seven of 10 patients had prior surgery of the thoracic aorta. Indications for surgery were post-dissection aneurysm in 4 patients, true aneurysm in 3, anastomotic aneurysms in 2 and Type B aortic dissection with pseudo-coarctation in 1. Surgical access was performed through median sternotomy with left hemi-clamshell extension in all cases. There was no in-hospital mortality, but perioperative neurological symptoms occurred in 2 patients. These 2 patients developed delayed stroke (after awaking) after an initial uneventful clinical course, and in 1 of them, neurological symptoms resolved completely during follow-up. The median follow-up was 7 (±13) months. There was no death and no need for additional redo surgery during this observational period. CONCLUSIONS Extensive surgery of the thoracic aorta using a double arterial perfusion technique in order to avoid lower body hypothermic circulatory arrest is an attractive option. Further refinements of this technique may enable the safe and effective simultaneous multisegmental treatment of thoracic aortic pathology in patients who would otherwise have to undergo a two-step surgical approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently developed technologies allow aortic valve implantation off-pump in a beating heart. In this procedure, the native, stenotic aortic valve is not removed, but simply crushed by a pressure balloon mounted on a percutaneous catheter. Removal of the native aortic cusps before valve replacement may reduce the incidence of annular or cuspal calcium embolization and late perivalvular leaks and increase implantable valve size. However, a temporary valve system in the ascending aorta may be necessary to maintain hemodynamic stability by reducing acute aortic regurgitation and left ventricular volume overload. This study evaluates the hemodynamic effects of a wire-mounted, monoleaflet, temporary valve apparatus in a mechanical cardiovascular simulator. Aortic flow, systemic pressure and left ventricular pressure were continuously monitored. An intraluminal camera obtained real-time proximal and distal images of the valve in operation. Insertion of the parachute valve in the simulator increased diastolic pressure from 7 to 38 mm Hg. Cardiac output increased from 2.08 to 4.66 L/min and regurgitant volume decreased from 65 to 23 mL. In conclusion, placement of a temporary valve in the ascending aorta may help maintain hemodynamic stability and improve off-pump aortic valve replacement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the last two decades, imaging of the aorta has undergone a clinically relevant change. As part of the change non-invasive imaging techniques have replaced invasive intra-arterial digital subtraction angiography as the former imaging gold standard for aortic diseases. Computed tomography (CT) and magnetic resonance imaging (MRI) constitute the backbone of pre- and postoperative aortic imaging because they allow for imaging of the entire aorta and its branches. The first part of this review article describes the imaging principles of CT and MRI with regard to aortic disease, shows how both technologies can be applied in every day clinical practice, offering exciting perspectives. Recent CT scanner generations deliver excellent image quality with a high spatial and temporal resolution. Technical developments have resulted in CT scan performed within a few seconds for the entire aorta. Therefore, CT angiography (CTA) is the imaging technology of choice for evaluating acute aortic syndromes, for diagnosis of most aortic pathologies, preoperative planning and postoperative follow-up after endovascular aortic repair. However, radiation dose and the risk of contrast induced nephropathy are major downsides of CTA. Optimisation of scan protocols and contrast media administration can help to reduce the required radiation dose and contrast media. MR angiography (MRA) is an excellent alternative to CTA for both diagnosis of aortic pathologies and postoperative follow-up. The lack of radiation is particularly beneficial for younger patients. A potential side effect of gadolinium contrast agents is nephrogenic systemic fibrosis (NSF). In patients with high risk of NSF unenhanced MRA can be performed with both ECG- and breath-gating techniques. Additionally, MRI provides the possibility to visualise and measure both dynamic and flow information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV). OBJECTIVES This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV. METHODS We retrospectively collected baseline characteristics, procedural data, and clinical follow-up findings from 12 centers in Europe and Canada that had performed TAV-in-BAV. RESULTS A total of 139 patients underwent TAV-in-BAV with the balloon-expandable transcatheter heart valve (THV) (n = 48) or self-expandable THV (n = 91) systems. Patient mean age and Society of Thoracic Surgeons predicted risk of mortality scores were 78.0 ± 8.9 years and 4.9 ± 3.4%, respectively. BAV stenosis occurred in 65.5%, regurgitation in 0.7%, and mixed disease in 33.8% of patients. Incidence of type 0 BAV was 26.7%; type 1 BAV was 68.3%; and type 2 BAV was 5.0%. Multislice computed tomography (MSCT)-based TAV sizing was used in 63.5% of patients (77.1% balloon-expandable THV vs. 56.0% self-expandable THV, p = 0.02). Procedural mortality was 3.6%, with TAV embolization in 2.2% and conversion to surgery in 2.2%. The mean aortic gradient decreased from 48.7 ± 16.5 mm Hg to 11.4 ± 9.9 mm Hg (p < 0.0001). Post-implantation aortic regurgitation (AR) grade ≥2 occurred in 28.4% (19.6% balloon-expandable THV vs. 32.2% self-expandable THV, p = 0.11) but was prevalent in only 17.4% when MSCT-based TAV sizing was performed (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p < 0.0001). Thirty-day device safety, success, and efficacy were noted in 79.1%, 89.9%, and 84.9% of patients, respectively. One-year mortality was 17.5%. Major vascular complications were associated with increased 1-year mortality (OR: 5.66, 95% CI: 1.21 to 26.43; p = 0.03). CONCLUSIONS TAV-in-BAV is feasible with encouraging short- and intermediate-term clinical outcomes. Importantly, a high incidence of post-implantation AR is observed, which appears to be mitigated by MSCT-based TAV sizing. Given the suboptimal echocardiographic results, further study is required to evaluate long-term efficacy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

IMPORTANCE Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES Survival, stroke, and New York Heart Association functional class. RESULTS Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To conduct a survey across European cardiac centres to evaluate the methods used for cerebral protection during aortic surgery involving the aortic arch. METHODS All European centres were contacted and surgeons were requested to fill out a short, comprehensive questionnaire on an internet-based platform. One-third of more than 400 contacted centres completed the survey correctly. RESULTS The most preferred site for arterial cannulation is the subclavian-axillary, both in acute and chronic presentation. The femoral artery is still frequently used in the acute condition, while the ascending aorta is a frequent second choice in the case of chronic presentation. Bilateral antegrade brain perfusion is chosen by the majority of centres (2/3 of cases), while retrograde perfusion or circulatory arrest is very seldom used and almost exclusively in acute clinical presentation. The same pumping system of the cardio pulmonary bypass is most of the time used for selective cerebral perfusion, and the perfusate temperature is usually maintained between 22 and 26°C. One-third of the centres use lower temperatures. Perfusate flow and pressure are fairly consistent among centres in the range of 10-15 ml/kg and 60 mmHg, respectively. In 60% of cases, barbiturates are added for cerebral protection, while visceral perfusion still receives little attention. Regarding cerebral monitoring, there is a general tendency to use near-infrared spectroscopy associated with bilateral radial pressure measurement. CONCLUSIONS These data represent a snapshot of the strategies used for cerebral protection during major aortic surgery in current practice, and may serve as a reference for standardization and refinement of different approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND New generation transcatheter heart valves (THV) may improve clinical outcomes of transcatheter aortic valve implantation. METHODS AND RESULTS In a nationwide, prospective, multicenter cohort study (Swiss Transcatheter Aortic Valve Implantation Registry, NCT01368250), outcomes of consecutive transfemoral transcatheter aortic valve implantation patients treated with the Sapien 3 THV (S3) versus the Sapien XT THV (XT) were investigated. An overall of 153 consecutive S3 patients were compared with 445 consecutive XT patients. Postprocedural mean transprosthetic gradient (6.5±3.0 versus 7.8±6.3 mm Hg, P=0.17) did not differ between S3 and XT patients, respectively. The rate of more than mild paravalvular regurgitation (1.3% versus 5.3%, P=0.04) and of vascular (5.3% versus 16.9%, P<0.01) complications were significantly lower in S3 patients. A higher rate of new permanent pacemaker implantations was observed in patients receiving the S3 valve (17.0% versus 11.0%, P=0.01). There were no significant differences for disabling stroke (S3 1.3% versus XT 3.1%, P=0.29) and all-cause mortality (S3 3.3% versus XT 4.5%, P=0.27). CONCLUSIONS The use of the new generation S3 balloon-expandable THV reduced the risk of more than mild paravalvular regurgitation and vascular complications but was associated with an increased permanent pacemaker rate compared with the XT. Transcatheter aortic valve implantation using the newest generation balloon-expandable THV is associated with a low risk of stroke and favorable clinical outcomes. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01368250.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The SOURCE XT Registry (Edwards SAPIEN XT Aortic Bioprosthesis Multi-Region Outcome Registry) assessed the use and clinical outcomes with the SAPIEN XT (Edwards Lifesciences, Irvine, California) valve in the real-world setting. BACKGROUND Transcatheter aortic valve replacement is an established treatment for high-risk/inoperable patients with severe aortic stenosis. The SAPIEN XT is a balloon-expandable valve with enhanced features allowing delivery via a lower profile sheath. METHODS The SOURCE XT Registry is a prospective, multicenter, post-approval study. Data from 2,688 patients at 99 sites were analyzed. The main outcome measures were all-cause mortality, stroke, major vascular complications, bleeding, and pacemaker implantations at 30-days and 1 year post-procedure. RESULTS The mean age was 81.4 ± 6.6 years, 42.3% were male, and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 20.4 ± 12.4%. Patients had a high burden of coronary disease (44.2%), diabetes (29.4%), renal insufficiency (28.9%), atrial fibrillation (25.6%), and peripheral vascular disease (21.2%). Survival was 93.7% at 30 days and 80.6% at 1 year. At 30-day follow-up, the stroke rate was 3.6%, the rate of major vascular complications was 6.5%, the rate of life-threatening bleeding was 5.5%, the rate of new pacemakers was 9.5%, and the rate of moderate/severe paravalvular leak was 5.5%. Multivariable analysis identified nontransfemoral approach (hazard ratio [HR]: 1.84; p < 0.0001), renal insufficiency (HR: 1.53; p < 0.0001), liver disease (HR: 1.67; p = 0.0453), moderate/severe tricuspid regurgitation (HR: 1.47; p = 0.0019), porcelain aorta (HR: 1.47; p = 0.0352), and atrial fibrillation (HR: 1.41; p = 0.0014), with the highest HRs for 1-year mortality. Major vascular complications and major/life-threatening bleeding were the most frequently seen complications associated with a significant increase in 1-year mortality. CONCLUSIONS The SOURCE XT Registry demonstrated appropriate use of the SAPIEN XT THV in the first year post-commercialization in Europe. The safety profile is sustained, and clinical benefits have been established in the real-world setting. (SOURCE XT Registry; NCT01238497).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

En la presente tesis desarrollamos una estrategia para la simulación numérica del comportamiento mecánico de la aorta humana usando modelos de elementos finitos no lineales. Prestamos especial atención a tres aspectos claves relacionados con la biomecánica de los tejidos blandos. Primero, el análisis del comportamiento anisótropo característico de los tejidos blandos debido a las familias de fibras de colágeno. Segundo, el análisis del ablandamiento presentado por los vasos sanguíneos cuando estos soportan cargas fuera del rango de funcionamiento fisiológico. Y finalmente, la inclusión de las tensiones residuales en las simulaciones en concordancia con el experimento de apertura de ángulo. El análisis del daño se aborda mediante dos aproximaciones diferentes. En la primera aproximación se presenta una formulación de daño local con regularización. Esta formulación tiene dos ingredientes principales. Por una parte, usa los principios de la teoría de la fisura difusa para garantizar la objetividad de los resultados con diferentes mallas. Por otra parte, usa el modelo bidimensional de Hodge-Petruska para describir el comportamiento mesoscópico de los fibriles. Partiendo de este modelo mesoscópico, las propiedades macroscópicas de las fibras de colágeno son obtenidas a través de un proceso de homogenización. En la segunda aproximación se presenta un modelo de daño no-local enriquecido con el gradiente de la variable de daño. El modelo se construye a partir del enriquecimiento de la función de energía con un término que contiene el gradiente material de la variable de daño no-local. La inclusión de este término asegura una regularización implícita de la implementación por elementos finitos, dando lugar a resultados de las simulaciones que no dependen de la malla. La aplicabilidad de este último modelo a problemas de biomecánica se estudia por medio de una simulación de un procedimiento quirúrgico típico conocido como angioplastia de balón. In the present thesis we develop a framework for the numerical simulation of the mechanical behaviour of the human aorta using non-linear finite element models. Special attention is paid to three key aspects related to the biomechanics of soft tissues. First, the modelling of the characteristic anisotropic behaviour of the softue due to the collagen fibre families. Secondly, the modelling of damage-related softening that blood vessels exhibit when subjected to loads beyond their physiological range. And finally, the inclusion of the residual stresses in the simulations in accordance with the opening-angle experiment The modelling of damage is addressed with two major and different approaches. In the first approach a continuum local damage formulation with regularisation is presented. This formulation has two principal ingredients. On the one hand, it makes use of the principles of the smeared crack theory to avoid the mesh size dependence of the structural response in softening. On the other hand, it uses a Hodge-Petruska bidimensional model to describe the fibrils as staggered arrays of tropocollagen molecules, and from this mesoscopic model the macroscopic material properties of the collagen fibres are obtained using an homogenisation process. In the second approach a non-local gradient-enhanced damage formulation is introduced. The model is built around the enhancement of the free energy function by means of a term that contains the referential gradient of the non-local damage variable. The inclusion of this term ensures an implicit regularisation of the finite element implementation, yielding mesh-objective results of the simulations. The applicability of the later model to biomechanically-related problems is studied by means of the simulation of a typical surgical procedure, namely, the balloon angioplasty.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cardiovascular diseases (CVDs) have reached an epidemic proportion in the US and worldwide with serious consequences in terms of human suffering and economic impact. More than one third of American adults are suffering from CVDs. The total direct and indirect costs of CVDs are more than $500 billion per year. Therefore, there is an urgent need to develop noninvasive diagnostics methods, to design minimally invasive assist devices, and to develop economical and easy-to-use monitoring systems for cardiovascular diseases. In order to achieve these goals, it is necessary to gain a better understanding of the subsystems that constitute the cardiovascular system. The aorta is one of these subsystems whose role in cardiovascular functioning has been underestimated. Traditionally, the aorta and its branches have been viewed as resistive conduits connected to an active pump (left ventricle of the heart). However, this perception fails to explain many observed physiological results. My goal in this thesis is to demonstrate the subtle but important role of the aorta as a system, with focus on the wave dynamics in the aorta.

The operation of a healthy heart is based on an optimized balance between its pumping characteristics and the hemodynamics of the aorta and vascular branches. The delicate balance between the aorta and heart can be impaired due to aging, smoking, or disease. The heart generates pulsatile flow that produces pressure and flow waves as it enters into the compliant aorta. These aortic waves propagate and reflect from reflection sites (bifurcations and tapering). They can act constructively and assist the blood circulation. However, they may act destructively, promoting diseases or initiating sudden cardiac death. These waves also carry information about the diseases of the heart, vascular disease, and coupling of heart and aorta. In order to elucidate the role of the aorta as a dynamic system, the interplay between the dominant wave dynamic parameters is investigated in this study. These parameters are heart rate, aortic compliance (wave speed), and locations of reflection sites. Both computational and experimental approaches have been used in this research. In some cases, the results are further explained using theoretical models.

The main findings of this study are as follows: (i) developing a physiologically realistic outflow boundary condition for blood flow modeling in a compliant vasculature; (ii) demonstrating that pulse pressure as a single index cannot predict the true level of pulsatile workload on the left ventricle; (iii) proving that there is an optimum heart rate in which the pulsatile workload of the heart is minimized and that the optimum heart rate shifts to a higher value as aortic rigidity increases; (iv) introducing a simple bio-inspired device for correction and optimization of aortic wave reflection that reduces the workload on the heart; (v) deriving a non-dimensional number that can predict the optimum wave dynamic state in a mammalian cardiovascular system; (vi) demonstrating that waves can create a pumping effect in the aorta; (vii) introducing a system parameter and a new medical index, Intrinsic Frequency, that can be used for noninvasive diagnosis of heart and vascular diseases; and (viii) proposing a new medical hypothesis for sudden cardiac death in young athletes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Body composition (fat mass [FM] and skeletal muscle mass [SMM]) predicts clinical outcomes. In particular, loss of SMM (sarcopenia) is associated with frailty and mortality. There are no data on the prevalence and impact of FM and SMM in patients undergoing transcatheter aortic valve implantation (TAVI). The objective of this study is to determine body composition from pre-TAVI computed tomography (CT) and evaluate its association with clinical outcomes in patients who underwent TAVI. A total of 460 patients (mean age 81 ± 8 years, men: 51%) were included. Pre-TAVI CTs of the aorto-ilio-femoral axis were analyzed for FM and SMM cross-sectional area at the level of the third lumbar vertebrae (L3). Regression equations correlating cross-sectional area at L3 to total body FM and SMM were used to determine prevalence of sarcopenia, obesity, and sarcopenic obesity in patients (64%, 65%, and 46%, respectively). Most TAVI procedures were performed through a transfemoral approach (59%) using a balloon-expandable valve (94%). The 30-day and mid-term (median 12 months [interquartile range 6 to 27]) mortality rates were 6.1% and 29.6%, respectively. FM had no association with clinical outcomes, but sarcopenia predicted cumulative mortality (hazard ratio 1.55, 95% confidence interval 1.02 to 2.36, p = 0.04). In conclusion, body composition analysis from pre-TAVI CT is feasible. Sarcopenia, obesity, and sarcopenic obesity are prevalent in the TAVI population, with sarcopenia predictive of cumulative mortality.