932 resultados para Indicator microorganisms


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quantitative variations in heterotrophic plate count (HPC) and in the presence of indicator microorganisms in 0.5, 1.5 and 20-L bottles of different brands of Brazilian mineral water were analyzed during their shelf life. No variations were identified in the presence of indicator microorganisms, but quantitative variations in HPC were observed in some brands, which suggests that changes may be occurring in the water quality during storage. The aim of this study was also to evaluate the quality of the bottled mineral waters and the presence of enterococci and Pseudomonas aeruginosa were verified in six and two bottles, respectively, which is in disagreement with the microbiological quality criteria established in the current legislation. Although no limit is set for HPC in mineral water, this study relies on the limit of 500 colony-forming units per mL of sample (CFU/mL). Seventy-two bottles presented levels above 500 CFU/mL and up to 560,000 CFU/mL. This study showed that the control of HPC (<500 CFU/mL) for non-returnable packaging seems to be adequate to ensure the quality of mineral water during storage. The high values of HPC and its variations detected during storage seem to fully justify the need for a reevaluation of the use of HPC in bottled mineral water quality management. More detailed studies on the potential health risk of HPC and its variations in mineral water are also needed. © 2012 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To determine the inhibitory capacity of lactic acid bacteria due to the action of antagonistic substances, we tested 474 isolates of Lactobacillus from the crop and cecum of chickens against gram-positive and gram-negative indicator microorganisms by the spot-on-the-lawn and well-diffusion antagonism methods. of the 474 isolates, 265 demonstrated antimicrobial activity against the indicator microorganisms. Isolates identified as L. reuteri, L. salivarius, or Lactobacillus spp. inhibited Enterococcus faecalis, E. faecium, Listeria monocytogenes, and Salmonella spp. but not L. casei, L. delbrueckii, L. fermentum, or L. helveticus by the well-diffusion simultaneous antagonism method under anaerobic incubation conditions. The antagonistic substances produced by some of the Lactobacillus isolates were inactivated after treatment by proteolytic enzymes, which suggested that the substances could be antimicrobial peptides or bacteriocins.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

While searching for healthier diets, people became more attentive to organic produce. Yet, organic foods may be more susceptible to microbiological contamination because of the use of organic fertilizers, a possible source of pathogenic bacteria. In this study, 130 samples of different organic and conventional vegetable varieties sold in Brazil were analyzed for mesophilic aerobic bacteria, yeasts and molds, total coliforms, Escherichia coli and Salmonella spp. Most of the mesophilic aerobic bacteria counts in organic and conventional vegetables ranged from 6 to 7 log10 CFU/g; most of the yeasts and molds counts ranged from 5 to 6 log10 CFU/g and most of the total coliforms counts ranged from 4 to 5 log10 CFU/g. E. coli was found in 41.5% of the organic and 40.0% of the conventional vegetables, and most samples had counts ranging from 1 to 2 log10 CFU/g. Salmonella spp. was not found in any sample. Comparative analyses of the microbial counts of organic and conventional vegetables showed that some organic varieties have greater counts. However, the global results show that this is not a trend. These results indicate the need of good farming practices, and proper sanitization before consumption, to ensure food quality and safety. © 2012 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Countries have different official programs and implement different sampling methods for the detection of Salmonella on poultry carcasses. In Brazil, a 25-g sample of skin and muscle excision (SME) from the wings, neck, and pericloacal parts is used; in the European Union (EU), a 25-g sample of neck skin (NSE) is used; and, in the United States, the whole carcass is rinsed with 400 ml of diluent (WCR). In the present study, these methods were evaluated to compare Salmonella occurrence and counts of hygiene indicator microorganisms (Escherichia coli, Enterobacteriaceae, and total viable count of aerobic mesophilic bacteria) using different carcasses from the same flock and also using different analytical units taken from the same carcass. Eighty flocks, with four broiler carcasses from each, were included in this study; three broilers were sampled according to protocols from Brazil, the EU, and the United States, and the last one by all three methods. SME, NSE, and WCR provided equivalent results (P > 0.05) for Salmonella detection on broiler carcasses when using different carcasses from the same flock and when using the same carcass. The predominant serovar was Salmonella Enteritidis. For the enumeration of hygiene indicator microorganisms, WRC provided higher counts than SME or NSE (P < 0.05), when using both the same or different carcasses. Therefore, it is possible to directly compare Salmonella results in poultry carcasses when using the methods recommended by the legislative bodies of Brazil, the United States, and the EU. However, WCR provides the best results for hygiene indicator microorganisms. Copyright © International Association for Food Protection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The use of all by-products of bovine slaughter is of high economic importance for the industries of products of animal origin. Among these products, fat has an important role, once fat rendering may generate several different products, such as protein material that may be used in the manufacture of meat products. However, in spite of the importance that the use of all by-products has for the economic balance of the industry, there are no reports on their use in Brazil, or studies that supply data on microbiological and physical-chemical local standards for this protein. Thus, the objective of this study was to evaluate microbiological and physical-chemical characteristics of protein material obtained from fat rendering, as well as to provide support for companies to use fat rendering to generate protein material, adding value to industrialized meat products.Materials, Methods & Results: The experimental production of edible protein obtained of fat rendering was conducted in slaughterhouse with supervision of the Brazilian Ministry of Agriculture, Livestock and Food Supply. Protein material was obtained in a continuous, humid heat system at high temperatures. Fat scraps containing protein were ground and cooked at high temperature (85 degrees C), and placed in a three phase decanter centrifuge. After centrifugation, protein material was ground again and packed. Samples were collected from 15 batches of protein material, and the following microbiological analyses were carried out: counts of aerobic mesophilic and psychrotrophic microorganisms, coliforms at 35 degrees C, Escherichia coli, sulfite-reducing Clostridium, and Staphylococcus aureus, besides presence or absence of Salmonella and Listeria monocytogens. The following physical-chemical analyses were also carried out: protein, total lipid, moisture, ash, carbohydrate, and energy content. Mean counts of mesophiles, psychrotrophs, and coliforms at 35 degrees C were 4.17; 3.69 and 1.87 (log CFU/g), respectively. Levels of protein, total lipids, moisture, ashes and carbohydrates were 27.50; 7.83; 63.88%; 0.24%; and 0.55%, respectively, and energy content was 182.63 kcal/100g.Discussion: Results of microbiological analyses demonstrated that, although low, the final product showed to be contaminated. Contamination that occurred during the second grinding procedure may be an explanation for these bacterial counts. Also, the temperature used for fat fusion was not enough to eliminate thermoduric microorganisms. However, even with the presence of indicator microorganisms in the samples, none was contaminated by E. coli, sulfite-reducing Clostridium, S. aureus, Salmonella or L. monocytogenes. Physical-chemical analyses showed that the product had adequate nutritional quality. Based on these results, it was possible to conclude that protein material obtained in fat rendering showed characteristics that enable the use of this product as raw material for processed meat products. Besides, the present study was the first one to present scientific results in relation to edible by-products obtained in fat rendering, supplying important information for slaughterhouses and meat-processing plants. The study also produced relevant data on the innocuousness of the product, which may be used to guide decision-making of health inspectors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to evaluate the hygienic-sanitary conditions of lamb carcasses for human consumption, this study aimed at quantifying populations of indicator microorganisms, such as: mesophiles and psychrotrophs, molds and yeasts, Escherichia coli, Staphylococcus spp. and at identifying pathogenic microorganisms (Salmonella sp. and Listeria spp.). The study was conducted in one lamb slaughterhouse located in the State of São Paulo. Swab samples were collected from muscle surface of forequarter and hindquarter regions of 30 half-carcasses after skinning, evisceration and washing processes. Population counts were between the following values in log10: 2,00 ± 0,32 and 2,59 ± 0,76 UFC/cm2 for mesophiles; 1,52 ± 0,98 and 2,35 ± 1,17 UFC/cm2 for psychrotrophs; 0,75 ± 0,87 and 1,23 ± 0,97 UFC/cm2 for molds and yeasts; 0,00 ± 0,00 and 0,31 ± 0,84 NMP/cm2 for Escherichia coli and 1,75 ± 0,71 and 1,95 ± 0,68 UFC/cm2 for Staphylococcus spp. Salmonella sp. and Listeria spp. were not detected from any of the sampled points. These results indicate the necessity to improve the hygienic-sanitary conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Groundwater is routinely analyzed for fecal indicators but direct comparisons of fecal indicators to the presence of bacterial and viral pathogens are rare. This study was conducted in rural Bangladesh where the human population density is high, sanitation is poor, and groundwater pumped from shallow tubewells is often contaminated with fecal bacteria. Five indicator microorganisms (E. coli, total coliform, F+RNA coliphage, Bacteroides and human-associated Bacteroides (HuBacteroides)) and various environmental parameters were compared to the direct detection of waterborne pathogens by quantitative PCR in groundwater pumped from 50 tubewells. Rotavirus was detected in groundwater filtrate from the largest proportion of tubewells (40%), followed by Shigella (10%), Vibrio (10%), and pathogenic E. coli (8%). Spearman rank correlations and sensitivity-specificity calculations indicate that some, but not all, combinations of indicators and environmental parameters can predict the presence of pathogens. Culture-dependent fecal indicator bacteria measured on a single date did not predict bacterial pathogens, but annually averaged monthly measurements of culturable E. coli did improve prediction for total bacterial pathogens. F+RNA coliphage were neither correlated nor sufficiently sensitive towards rotavirus, but were predictive of bacterial pathogens. A qPCR-based E. coli assay was the best indicator for the bacterial pathogens, rotavirus and all pathogens combined. Since groundwater cannot be excluded as a significant source of diarrheal disease in Bangladesh and neighboring countries with similar characteristics, the need to develop more effective methods for screening tubewells with respect to microbial contamination is necessary.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O propósito do presente estudo foi investigar e monitorar a remoção de cistos de Giardia spp. e oocistos de Cryptosporidium spp. por diferentes processos de uma estação de tratamento de esgoto (ETE) em escala plena, composta basicamente por tratamento preliminar, reator UASB e flotador por ar dissolvido, e verificar a ocorrência desses protozoários no lodo do reator UASB e do flotador. Além disso, avaliou-se a remoção desses parasitos pelo processo de flotação por ar dissolvido em escala de bancada (equipamento Flotateste). Analisou-se a qualidade das amostras a partir de variáveis físicas e químicas, e pela detecção de microrganismos indicadores - E. coli, coliformes totais e Clostridium perfringens. Os métodos de detecção de protozoários se basearam nas etapas de concentração (tripla centrifugação ou filtração em membrana seguida de tripla centrifugação); purificação por separação imunomagnética (IMS); detecção por reação de imunofluorescência direta (RID). As recuperações de cistos variaram de 32,6 a 67,0 % dependendo do método adotado, já para os oocistos as recuperações estiveram na faixa de 5,6 a 12,0 %. Na ETE-Monjolinho foram detectadas significativas quantidades de cistos de Giardia spp. em 100% das amostras de esgoto analisadas, com concentração média de 1,89 x 104 e 2,35 x 102 cistos.L-1 no esgoto bruto e tratado, respectivamente. Já os oocistos de Cryptosporidium spp. foram detectados em 39,0 % das amostras de esgoto, com concentração média de 1,35 x 102 oocistos.L-1 no esgoto bruto e 5,87 oocistos.L-1 em esgoto tratado (após flotador). A remoção global da ETE para remoção de Giardia spp. foi em média 2,03 log. O lodo do reator UASB e lodo do flotador apresentaram altas quantidade de (oo)cistos, constatando-se a tendência desses sistemas em concentrar os (oo)cistos por seus processos físicos. Algumas correlações significativas foram encontradas, como correlação entre a concentração de cistos no lodo e a variável sólidos totais, a concentração de cistos no esgoto bruto e as variáveis cor aparente, DQO total e particulada, e a concentração de cistos no efluente UASB e o microrganismo Clostridium perfringens. Diferentemente do flotador em escala plena, o processo do flotação por ar dissolvido em escala de bancada alcançou elevadas remoções médias de cistos de Giardia spp., entre 2,5 e 2,7 log nas diferentes condições de floculação estudadas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. To determine whether copper incorporated into hospital ward furnishings and equipment can reduce their surface microbial load. Design. A crossover study. Setting. Acute care medical ward with 19 beds at a large university hospital. Methods. Fourteen types of frequent-touch items made of copper alloy were installed in various locations on an acute care medical ward. These included door handles and push plates, toilet seats and flush handles, grab rails, light switches and pull cord toggles, sockets, overbed tables, dressing trolleys, commodes, taps, and sink fittings. Their surfaces and those of equivalent standard items on the same ward were sampled once weekly for 24 weeks. The copper and standard items were switched over after 12 weeks of sampling to reduce bias in usage patterns. The total aerobic microbial counts and the presence of indicator microorganisms were determined. Results. Eight of the 14 copper item types had microbial counts on their surfaces that were significantly lower than counts on standard materials. The other 6 copper item types had reduced microbial numbers on their surfaces, compared with microbial counts on standard items, but the reduction did not reach statistical significance. Indicator microorganisms were recovered from both types of surfaces; however, significantly fewer copper surfaces were contaminated with vancomycin-resistant enterococci, methicillin-susceptible Staphylococcus aureus, and coliforms, compared with standard surfaces. Conclusions. Copper alloys (greater than or equal to 58% copper), when incorporated into various hospital furnishings and fittings, reduce the surface microorganisms. The use of copper in combination with optimal infection-prevention strategies may therefore further reduce the risk that patients will acquire infection in healthcare environments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The pig slaughter process involve different steps that can influence the microbiological quality of carcasses. At this, the understanding of the slaughter process on the microbiological aspects is necessary for the implementation and evaluation of critical control points. The microbiological control of the slaughter process should involve the evaluation of pathogens prevalence and levels of quality and hygiene indicator microorganisms. This study aimed at investigating the influence of steps slaughter process on the microbiological levels of pig carcasses, and evaluate if there is correlation between pathogens (Salmonella spp. and Listeria monocytogenes) and indicators (aerobic mesophilic counts, total coliforms, Escherichia coli and Enterobacteriaceae) microorganisms. A high Salmonella soroprevalence in pigs were founded before the slaughter (57.49 %). While the Salmonella prevalence in carcasses at the initial stage of the slaughter was 26.67 % and in the final stage 1.11 %, L. monocytogenes was detected only in the final washing and cooling steps, with a prevalence of 21.11 and 8.89 %, respectively. The aerobic mesophilic counts, Enterobacteriaceae, total coliforms and E. coli levels in initial steps of slaughter process were 4.25 ± 0.37; 1.25 ± 0.38; 1.10 ± 0.35 and 0.86 ± 0.36, respectively. At the end of slaughter process the results were lower (ranging from 0.16 at 2.70 log CFU/cm2). The step that most reduced microbiological levels was the scalding. The dehairing was a critical step that led to a significant increase of microorganisms levels in the process (p < 0.05). The evisceration not proved to be a critical step on the increase of microbial levels, differently of the final washing, which showed significant increases (p < 0.05) over the levels of aerobic counts, total coliforms, E. coli and enterobacterias (0.30; 0.36; 0.27 and 0.42 log respectively) and Salmonella spp. and L. monocytogenes. The chilling contributes significantly to the reduction of microbiological levels of carcasses, bringing them to levels below the all process stages, with the exception of scalding. No correlation between the hygiene indicator microorganisms used and presence of Salmonella spp. and L. monocytogenes were obtained (p < 0.05). The results show that steps in the process are critical to the sanitary profile, which implies the need to implement actions in the process to reducing the microbiological levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study aimed to evaluate the suitability of Escherichia coli, enterococci and C. perfringens to assess the microbiological quality of roof harvested rainwater, and to assess whether the concentrations of these faecal indicators can be used to predict the presence or absence of specific zoonotic bacterial or protozoan pathogens. From a total of 100 samples tested, respectively 58%, 83% and 46% of samples were found to be positive for E. coli, enterococci and C. perfringens spores, as determined by traditional culture based methods. Additionally, in the samples tested, 7%, 19%, 1%, 8%, 17%, and 15% were PCR positive for A. hydrophila lip, C. coli ceuE, C. jejuni mapA, L. pneumophila mip, Salmonella invA, and G. lamblia β-giardin genes. However, none of the samples was positive for E. coli O157 LPS, VT1, VT2 and C. parvum COWP genes. The presence or absence of these potential pathogens did not correlate with any of the faecal indicator bacterial concentrations as determined by a binary logistic regression model. The roof-harvested rainwater samples tested in this study appear to be of poor microbiological quality and no significant correlation was found between the concentration of faecal indicators and pathogenic microorganisms. The use of faecal indicator bacteria raises questions regarding their reliability in assessing the microbiological quality of water and particularly their poor correlation with pathogenic microorganisms. The presence of one or more zoonotic pathogens suggests that the microbiological analysis of water should be performed, and appropriate treatment measures should be undertaken especially in tanks where the water is used for drinking.