976 resultados para Implant overdenture


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Statement of problem. Implant overdenture prostheses are prone to acrylic resin fracture because of space limitations around the implant overdenture components.Purpose. The purpose of this study was to evaluate the influence of E-glass fibers and acrylic resin thickness in resisting acrylic resin fracture around a simulated overdenture abutment.Material and methods. A model was developed to simulate the clinical situation of an implant overdenture abutment with varying acrylic resin thickness (1.5 or 3.0 mm) with or without E-glass fiber reinforcement. Forty-eight specimens with an underlying simulated abutment were divided into 4 groups (n=12): 1.5 mm acrylic resin without E-glass fibers identified as thin with no E-glass fiber mesh (TN-N); 1.5 mm acrylic resin with E-glass fibers identified as thin with E-glass fiber mesh (TN-F); 3.0 mm acrylic resin without E-glass fibers identified as thick without E-glass fiber mesh (TK-N); and 3.0 mm acrylic resin with E-glass fibers identified as thick with E-glass fiber mesh (TK-F). All specimens were submitted to a 3-point bending test and fracture loads (N) were analyzed with a 2-way ANOVA and Tukey's post hoc test (alpha=.05).Results. The results revealed significant differences in fracture load among the 4 groups, with significant effects from both thickness (P<.001) and inclusion of the mesh (P<.001). Results demonstrated no interaction between mesh and thickness (P=.690). The TN-N: 39 +/- 5 N; TN-F: 50 +/- 6.9 N; TK-N: 162 +/- 13 N; and TK-F: 193 +/- 21 N groups were all statistically different (P<.001).Conclusions. The fracture load of a processed, acrylic resin implant-supported overdenture can be significantly increased by the addition of E-glass fibers even when using thin acrylic resin sections. on a relative basis, the increase in fracture load was similar when adding E-glass fibers or increasing acrylic resin thickness. (J Prosthet Dent 2011;106:373-377)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The treatment of extensive pathologic lesions in the jaw, most of the time, can generate rehabilitation problems to the patient. The solid ameloblastoma is a locally invasive odontogenic tumor with a high recurrence rate. Its treatment is aggressive and accomplished through resection with safety margin. The criterion standard for reconstruction is autogenous bone, but it can provide a high degree of resorption, causing inconvenience to the patient because of lack of rehabilitative option. This study aimed to describe a patient with ameloblastoma treated through resection and reconstruction with autogenous bone graft, in which, after an extensive resorption of the graft was made, a modified bar was applied to support a prosthetic implant overdenture. Copyright © 2013 by Mutaz B. Habal, MD.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

L’augmentation de la population âgée dans la société indique que les systèmes de soins de la santé font face à de nouveaux défis. Les hauts niveaux d’incapacité qui en résultent peuvent être réduits par les nouvelles technologies, la promotion de la santé ainsi que des stratégies de prévention. Les écrits scientifiques récents soulignent la supériorité des prothèses dentaires implanto-portées par rapport aux prothèses conventionnelles en termes de satisfaction et de qualité de la vie des patients. Cependant, il n'est toujours pas clair si ces avantages ont des effets positifs à long terme sur la santé orale et générale ainsi que sur la qualité de vie des populations âgées. Objectifs, Hypothèses : Notre but était de mesurer l’impact des prothèses mandibulaires retenues par 2 implants sur la qualité de vie associée à la santé bucco-dentaire et générale ainsi que sur la santé orale et la qualité du sommeil des aînés édentés. Nous avons évalué les hypothèses nulles suivantes : il n'y a aucune différence entre les individus portants des prothèses mandibulaires retenues par 2 implants (IODs) et ceux qui portent des prothèses conventionnelles (CDs), par rapport à la qualité de vie reliée à la santé bucco-dentaire et générale, la santé orale et la qualité du sommeil, un an après avoir reçu leurs nouvelles prothèses. Méthodes : Dans cette étude randomisée contrôlée, 255 aînés ont reçu au hasard IODs ou les CDs, les deux types de prothèses étant opposés à des prothèses maxillaires conventionnelles. La qualité de la vie reliée à la santé bucco-dentaire (OHRQoL) et la santé générale subjective ont été mesurées avec les questionnaires Oral Health Impact Profile (OHIP-20) et Short Form-36 (SF-36) en condition pré-traitement et après un an. La qualité du sommeil et la somnolence diurne ont été mesurées à l’aide du questionnaire Qualité de Sommeil de Pittsburg et de l'Échelle de Somnolence Epworth. La santé orale a été évaluée par un examen clinique. Les variables indépendantes étaient le sens de cohérence et le type de prosthèse, ainsi que des variables socio-démographiques. En utilisant des analyses statistiques bi et multi-factorielles, des comparaisons à l’intérieur d’un même groupe et entre deux groupes ont été effectuées. Résultats : Les différences pré et post traitement pour les cotes OHIP étaient significativement plus grandes pour le groupe IOD que le groupe CD (p<0.05). Le type de traitement et la cote pré-traitement étaient des facteurs significatifs à OHRQoL (p < 0.0001). Dans le groupe CD, il y avait une diminution significative par rapport aux cotes de «Physical Component Scores (PCS)», le fonctionnement physique, le rôle physique et la douleur physique entre les données pré-traitement et un an après le traitement, ce qui indique une diminution au niveau de la santé générale subjective. Dans le groupe IOD, une diminution statistiquement non significative a été remarquée par rapport à toutes les cotes des sous-échelles de SF-36, sauf pour la douleur physique. Le modèle final de régression a démontré qu’après ajustement pour les variables âge, sexe, statut marital et type de traitement, la cote totale finale d’OHIP et les données de bases de PCS prédisaient la cote finale de PCS (p < 0.0001). Aucune corrélation significative entre sens de cohérence et OHRQoL n'a été détectée (r =-0.1; p > 0.05). Les aînés porteurs des prothèses conventionnelles avaient presque 5 fois plus de chance d’avoir une stomatite prothétique que ceux portant des prothèses mandibulaires hybrides retenues par 2 implants (p < 0.0001). Les aînés ayant subjectivement une mauvaise santé générale avaient une qualité de sommeil moins bonne que ceux avec une meilleure santé générale subjective (p < 0.05). Les personnes qui avaient une OHRQoL moins bonne étaient presque 4 fois plus somnolentes pendant le jour que celles avec une meilleure OHRQoL (p=0.003, χ2; OR =3.8 CI 1.5 to 9.8). L'analyse de régression a montré que la santé générale subjective et OHRQoL prévoient la qualité du sommeil (p=0.022 et p=0.001, respectivement) et la somnolence diurne (p=0.017 et p=0.005, respectivement). Conclusions: Les résultats de cette étude suggèrent que, chez les aînés édentés, des prothèses mandibulaires hybrides retenues par deux implants amènent une amélioration significative de la qualité de vie reliée à la santé bucco-dentaire et maintiennent la sensation d’une meilleure santé physique. Des prothèses hybrides implanto-portées peuvent contribuer à la santé orale en réduisant les traumatismes infligés à la muqueuse orale et en contrôlant la stomatite prothétique. Les aînés édentés dont le niveau de qualité de vie reliée à la santé bucco-dentaire est bas, peuvent aussi avoir des troubles de qualité du sommeil.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To evaluate the masticatory efficiency of patients rehabilitated with conventional dentures (CDs) or implant-retained mandibular overdentures. Background: Despite the evident benefits of implants on mastication as assessed by subjective patient-based outcomes, the extent of implant overdenture treatment effect on food comminution is not well established. Materials and methods: A randomised clinical trial was carried out with 29 completely edentulous patients divided into two groups. The first group was rehabilitated with a mandibular overdenture retained by two splinted implants with bar-clip system, while the second group was rehabilitated with a mandibular CD. Both groups also were rehabilitated with maxillary CDs. Masticatory efficiency and patient satisfaction were assessed 3 months after denture insertion. Masticatory efficiency was evaluated through the colorimetric method with the beads as the artificial test-food. Comparisons for masticatory efficiency and patient satisfaction were performed using Student's t-test (alpha = 0.05). Results: No significant statistical difference was found for masticatory efficiency (p = 0.198). Patient overall satisfaction was significantly higher for the mandibular overdenture (p < 0.001). In addition, mandibular overdenture patients were significantly more satisfied with chewing experience (p < 0.05) and retention of the lower denture (p < 0.005). Conclusion: The results of this study suggest that mandibular overdenture significantly improves chewing experience, although limited effect on masticatory efficiency has been observed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: The mandibular implant overdenture is a popular treatment modality and is well documented in the literature. Follow-up studies with a long observation period are difficult to perform due to the increasing age of patients. The present data summarize a long-term clinical observation of patients with implant overdentures. MATERIALS AND METHODS: Between 1984 and 1997, edentulous patients were consecutively admitted for treatment with an implant overdenture. The dentures were connected to the implants by means of bars or ball anchors. Regular maintenance was provided with at least one or two scheduled visits per year. Recall attendance and reasons for dropout were analyzed based on the specific history of the patient. Denture maintenance service, relining, repair, and fabrication of new dentures were identified, and complications with the retention devices specified separately. RESULTS: In the time period from 1984 to 2008, 147 patients with a total of 314 implants had completed a follow-up period of >10 years. One hundred one patients were still available in 2008, while 46 patients were not reexamined for various reasons. Compliance was high, with a regular recall attendance of >90%. More than 80% of dentures remained in continuous service. Although major prosthetic maintenance was rather low in relation to the long observation period, visits to a dental hygienist and dentist resulted in an annual visit rate of 1.5 and 2.4, respectively. If new dentures became necessary, these were made in student courses, which increased the treatment time and number of appointments needed. Complications with the retention devices consisted mostly of the mounting of new female retainers, the repair of bars, and the changing of ball anchors. The average number of events and the rate of prosthetic service with ball anchors were significantly higher than those with bars. Twenty-two patients changed from ball anchors to bars; 9 patients switched from a clip bar to a rigid U-shaped bar. CONCLUSIONS: This long-term follow-up study demonstrates that implant overdentures are a favorable solution for edentulous patients with regular maintenance. In spite of specific circumstances in an aging population, it is possible to provide long-term care, resulting in a good prognosis and low risk for this treatment modality. For various reasons the dropout rate can be considerable in elderly patients and prosthetic service must be provided regularly.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND Implant-overdentures supported by rigid bars provide stability in the edentulous atrophic mandible. However, fractures of solder joints and matrices, and loosening of screws and matrices were observed with soldered gold bars (G-bars). Computer-aided designed/computer-assisted manufactured (CAD/CAM) titanium bars (Ti-bars) may reduce technical complications due to enhanced material quality. PURPOSE To compare prosthetic-technical maintenance service of mandibular implant-overdentures supported by CAD/CAM Ti-bar and soldered G-bar. MATERIALS AND METHODS Edentulous patients were consecutively admitted for implant-prosthodontic treatment with a maxillary complete denture and a mandibular implant-overdenture connected to a rigid G-bar or Ti-bar. Maintenance service and problems with the implant-retention device complex and the prosthesis were recorded during minimally 3-4 years. Annual peri-implant crestal bone level changes (ΔBIC) were radiographically assessed. RESULTS Data of 213 edentulous patients (mean age 68 ± 10 years), who had received a total of 477 tapered implants, were available. Ti-bar and G-bar comprised 101 and 112 patients with 231 and 246 implants, respectively. Ti-bar mostly exhibited distal bar extensions (96%) compared to 34% of G-bar (p < .001). Fracture rate of bars extensions (4.7% vs 14.8%, p < .001) and matrices (1% vs 13%, p < .001) was lower for Ti-bar. Matrices activation was required 2.4× less often in Ti-bar. ΔBIC remained stable for both groups. CONCLUSIONS Implant overdentures supported by soldered gold bars or milled CAD/CAM Ti-bars are a successful treatment modality but require regular maintenance service. These short-term observations support the hypothesis that CAD/CAM Ti-bars reduce technical complications. Fracture location indicated that the titanium thickness around the screw-access hole should be increased.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectifs: Observer l’évolution de la stomatite prothétique dans le temps quant à la fréquence et la sévérité ainsi que son association avec de potentiels facteurs de risque au cours d’un suivi longitudinal de 2 ans. Matériels et méthodes : Cent trente-cinq patients âgés complètement édentés et en bonne santé ont été sélectionnés pour participer à cette étude et ont été divisés de façon randomisée en deux groupes. Ils ont tous reçu une prothèse dentaire amovible totale conventionnelle au maxillaire supérieur. La moitié d’entre eux a reçu une prothèse totale mandibulaire implanto-portée retenue par deux attachements boule et l’autre moitié une prothèse conventionnelle. Ils ont été suivis sur une période de deux ans. Les données sociodémographiques, d’habitudes de vie, d’hygiène et de satisfaction des prothèses ont été amassées à l’aide de questionnaires. Les patients ont aussi subi un examen oral complet lors duquel une évaluation de la stomatite prothétique, basée sur la classification de Newton, a été effectuée ainsi qu’un prélèvement de la plaque prothétique. Les analyses microbiologiques pertinentes afin de détecter la présence de Candida ont ensuite été effectuées. Des tests Chi-carré de Pearson et McNemar ont été utilisés pour analyser la fréquence de la stomatite, son association avec de possibles facteurs de risque ainsi que son évolution dans le temps. Des rapports de cotes (odds ratio) et leurs intervalles de confiance (95%) ont été effectués afin de déterminer la force d’association entre les facteurs de risque et la stomatite prothétique. Résultats : La prévalence de la stomatite a augmenté entre la première (63,6%) et la deuxième année de suivi (88,7%) avec une incidence de 78,8%. Les patients souffrant d’une stomatite de type 2 ou 3 et qui brossent leur palais ont environ 6 fois plus de chance de voir la sévérité de leur stomatite diminuer [p = 0,04 OR 5,88 CI (1,1-32,2)]. Il n’y a pas d’association statistiquement significative entre la fréquence de la stomatite et les facteurs de risque investigués. La prévalence de la candidose est demeurée stable dans le temps (45,8% et 49,2% à la première et deuxième année de suivi respectivement, p > 0,05). Il n’y a pas d’association entre la présence d’une candidose orale, la stomatite prothétique et les facteurs de risque étudiés. Conclusion : Les résultats de cette étude suggèrent que la stomatite prothétique progresse dans le temps indépendamment de la présence d’une candidose. Le brossage du palais pourrait être une approche simple à conseiller aux patients souffrant d’une stomatite prothétique de type 2 ou 3.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Problématique : La satisfaction des patients et la qualité de vie reliée à la santé bucco-dentaire (OHRQoL) sont deux mesures de résultats fréquemment utilisées durant les études cliniques. Néanmoins, chez les patients totalement édentés, les évidences scientifiques relatives au niveau de relation entre ces deux mesures sont faibles. De plus, on ignore toujours quels éléments de la satisfaction des patients relativement à leurs prothèses partagent la meilleure relation avec la OHRQoL. Objectifs : Déterminer, chez les patients totalement édentés, s’il existe un lien entre leur satisfaction de leurs prothèses et leur OHRQoL et identifier les déterminants de satisfaction qui démontrent le meilleur niveau de relation avec la OHRQoL. Méthodologie : Les données provenant de 255 patients totalement édentés qui ont participé à une étude randomisée et contrôlée ont été utilisées. La OHRQoL a été évaluée à l’aide du questionnaire Oral Health Impact Profile (OHIP-20). Le McGill Denture Satisfaction Instrument a été utilisé pour estimer la satisfaction des patients. Ces mesures ont été prises au temps initial, à 6 mois et à 12 mois suivants la mise en bouche des prothèses. Des analyses statistiques de régression linéaire simples et multiples ont été utilisées afin d’évaluer la relation entre les deux mesures. Résultats : Une relation positive et considérable existe entre la satisfaction des patients totalement édentés et leur OHRQoL. La difficulté masticatoire (P = .005) et la condition buccale (P = .002) sont les éléments de la satisfaction qui possèdent le meilleur lien avec la OHRQoL. Ces deux facteurs expliquent 46.4% (P = .0001) de la variance dans l’amélioration d’OHIP suivant un traitement prosthodontique. La relation décrite est dépendante du temps, mais pas du type de traitement ni des variables sociodémographiques. Conclusions : Dans les limites de l’étude, il est conclu qu’une relation positive existe entre la satisfaction des patients et leur OHRQoL. La difficulté masticatoire et la condition buccale sont les deux éléments de la satisfaction les plus importants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Problématique : La majorité des études publiées sur la réhabilitation par mise en charge immédiate de deux implants non jumelés avec une prothèse totale mandibulaire de recouvrement n’ont rapporté que des mesures cliniques objectives et très peu ont évalué les mesures centrées sur le patient, et ce, avec des erreurs de mesure. Aucune étude n’a évalué les attentes des patients vis-à-vis d'un tel protocole. Objectifs : Évaluer les attentes, le niveau de satisfaction ainsi que la qualité de vie reliée à la santé bucco-dentaire des édentés complets suite à un protocole de mise en charge immédiate. Méthodologie : Cet essai clinique de phase 1 utilise un design pré-post afin d’évaluer les mesures centrées sur le patient. Dix-huit individus, complètement édentés et âgés en moyenne de 62,39 ± 7,65 ans, ont reçu une prothèse totale mandibulaire de recouvrement sur deux implants non jumelés suite à un protocole de mise en charge immédiate, conjointement à une prothèse totale conventionnelle maxillaire. Un instrument adapté pour mesurer leurs attentes à l’aide d’échelles visuelles analogues, le questionnaire « McGill Denture Satisfaction Instrument » ainsi que le questionnaire OHIP-20 ont été remis aux patients avant de procéder aux traitements (T0), ainsi qu’aux rendez-vous de suivi à 2 semaines (T1), 1 mois (T2) et 4 mois (T3). De plus, l’inventaire de personnalité révisé (NÉO PI-R) ainsi qu’un questionnaire sociodémographique ont été remplis par les participants. Les « change scores » ont été calculés puis des tests non paramétriques et des analyses de variances en mesures répétées suivies de comparaisons par paires ont été utilisés afin d’analyser les données recueillies. La taille d’effet a été estimée. Résultats : Les participants avaient différentes attentes par rapport à la mise en charge immédiate. Certains s’attendaient à un effet positif à court terme par rapport à leur apparence esthétique (83,3 %) et à leur vie sociale (55,7 %), alors que d’autres avaient des craintes envers leur confort (5,6 %), leur habileté à mastiquer (11,1 %) et à nettoyer leur prothèse inférieure (11,1 %). À 4 mois, le protocole de mise en charge immédiate avait rencontré la majorité des attentes des patients par rapport à l’esthétique (94.4 %), la mastication (83.3 %), la phonétique (61.1 %), le confort (94.4 %), l’hygiène (88.9 %) et leur vie sociale (88.9 %). Une amélioration statistiquement significative de la satisfaction en générale, du confort, de l’esthétique, de la stabilité de la prothèse inférieure et de l’habileté à mastiquer a été notée à 2 semaines (p<0,001). Également, les comparaisons par paires ont révélé une diminution statistiquement significative du score total de l’OHIP-20 (p < 0,001) de même que la majorité des domaines de l’OHIP (p < 0.01), sauf pour l’handicap social qui n’a diminué significativement qu’après 1 mois (p = 0.01). Ces changements (pour la satisfaction et la qualité de vie) sont restés stables au cours des suivis subséquents. Indépendamment des traits de personnalité et des variables sociodémographiques, le protocole immédiat a satisfait 94,4 % des participants et a amélioré leur qualité de vie avec une large magnitude d’effet (d = 1.9; p < 0.001). Bien que deux patients aient perdu des implants au cours du traitement, 100 % des participants étaient d’accord pour recommander cette procédure à leurs pairs. Conclusions: Le protocole de mise en charge immédiate semble satisfaire les patients quelles que soient leurs attentes. Le protocole MCI peut améliorer, à court terme, la qualité de vie des patients totalement édentés. Les résultats prometteurs de la phase 1 devraient être corroborés lors de la 2e phase de cette étude.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The oral rehabilitation of the patients toothless totals presents large difficulties, because diverse factors act limiting the treatment with complete dentures conventional, as severe reabsorption of the alveolar process, generating for the phonetic patient difficulties and of mastication, annoyance, retention lack and stability of the prosthesis. With the emergence of you implant them osseointegratin idealized by Prof o Branemark, these aspects were improved by means of the possibility of new treatment options, as the overdentures tissue-implant-supported. However, the protocol of Branemark demanded a period of scaring from three to six months, owing the patients to await this time for the placement of the final prosthesis. This way, the surgical technique of immediate load was proposed to abbreviate this period, improving the transition phase, at the same time that it reduces the problems psychological associates. This way, the objective of the present study is to carry out a literature revision about the works that used overdentures comparing immediate and late load, the best alternative and factors wrapped in the success of the procedure discussing. © 2008 1995, Editorial Ciencias médicas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The use of endosseous dental implants has become common practice for the rehabilitation of edentulous patients, and a two-implant overdenture has been recommended as the standard of care. The use of small-diameter implants may extend treatment options and reduce the necessity for bone augmentation. However, the mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable. Purpose: This randomized, controlled, double-blind, multicenter study investigated in a split-mouth model whether small-diameter implants made from Titanium-13Zirconium alloy (TiZr, Roxolid™) perform at least as well as Titanium Grade IV implants. Methods and Materials: Patients with an edentulous mandible received one TiZr and one Ti Grade IV small-diameter bone level implant (3.3 mm, SLActive®) in the interforaminal region. The site distribution was randomized and double-blinded. Outcome measures included change in radiological peri-implant bone level from surgery to 12 months post-insertion (primary), implant survival, success, soft tissue conditions, and safety (secondary). Results: Of 91 treated patients, 87 were available for the 12-month follow-up. Peri-implant bone level change (-0.3 ± 0.5 mm vs -0.3 ± 0.6 mm), plaque, and sulcus bleeding indices were not significantly different between TiZr and Ti Grade IV implants. Implant survival rates were 98.9 percent and 97.8 percent, success rates were 96.6 percent and 94.4 percent, respectively. Nineteen minor and no serious adverse events were related to the study devices. Conclusion: This study confirms that TiZr small-diameter bone level implants provide at least the same outcomes after 12 months as Ti Grade IV bone level implants. The improved mechanical properties of TiZr implants may extend implant therapy to more challenging clinical situations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to compare the stress distribution induced by posterior functional loads on conventional complete dentures and implant-retained overdentures with different attachment systems using a two-dimentional Finite Element Analysis (FEA-2D). Three models representative of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture over two splinted implants connected with the bar-clip system; Group C, a model of edentuluos mandible supporting an overdenture over two unsplinted impants with the O-ring system. Evaluation was conducted on Ansys software, with a vertical force of 100 N applied on the mandibular left first molar. When the stress was evaluated in supporting tissues, groups B (51.0 MPa) and C (52.6 MPa) demonstrated higher stress values than group A (10.1 MPa). Within the limits of this study, it may be conclued that the use of an attachment system increased stress values; furthermore, the use of splinted implants associated with the bar-clip attachment system favoured a lower stress distribution over the supporting tissue than the unsplinted implants with an O-ring abutment to retain the manibular overdenture.