903 resultados para I-131 THERAPY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the impact of iodine-131 therapy received during childhood and adolescence and correlate it with the quality of life in these patients. Methods: We studied 19 patients diagnosed with cancer in childhood or adolescence who underwent thyroidectomy and supplemental therapy with I-131. We also recruited a control group of healthy subjects with the same demographic parameters. All patients were subjected to a scintigraphy examination of the salivary glands, and were also asked to complete a questionnaire in order to assess their overall quality of life. In addition, a more specific questionnaire for patients with head and neck cancer was also given to all study participants. Results: The quantitative and qualitative analyses of the salivary glands showed functional deficits with greater involvement of the parotid gland for volume, concentration and excretion. The right submandibular gland showed significant changes for volume in the patient group. The questionnaires made it possible to observe significant differences between the patient and control groups for symptoms such as thick saliva, dry mouth and speech problems. Conclusion: In spite of being very effective and widely used, iodine radionuclide therapy is correlated with a lower quality of life in young people.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Descrever uma série de pacientes portadores de obstrução do sistema lacrimal associado à radioiodoterapia para tratamento de carcinoma de tireoide, revisar os dados clínicos e a resposta ao tratamento cirúrgico desta rara complicação. MÉTODOS: Foi realizada uma análise retrospectiva dos achados oftalmológicos de pacientes com histórico de carcinoma de tireoide previamente submetidos à tireoidectomia e à RIT que foram encaminhados para cirurgia de vias lacrimais. RESULTADOS: Dezessete pacientes com carcinoma de tireoide tratados com tireoidectomia e RIT apresentaram obstrução do ducto nasolacrimal sintomática após período médio de 13,2 meses do tratamento do câncer. Onze pacientes tiveram epífora bilateral, 8 com mucocele de saco lacrimal. A idade dos pacientes variou entre 30 e 80 anos, sendo 10 com idade menor ou igual a 49 anos. A dose cumulativa média de radioiodo administrada foi de 571 mCi (variação entre 200-1200 mCi). Sintomas de obstrução nasal e aumento de glândulas salivares ocorreram em 53% dos pacientes. Todos os pacientes foram submetidos à dacriocistorrinostomia. Observou-se ainda que nos 3 pacientes mais jovens houve maior sangramento intraoperatótio e dilatação de saco lacrimal. A resolução completa da epífora e da dacriocistite ocorreu em 82,4%, e foi parcial em 17,6% (3 pacientes mantiveram queixa unilateral após a correção da obstrução bilateralmente). O seguimento médio foi de 6 meses (intervalo: 2-24 meses). CONCLUSÕES: Alta dose cumulativa de radioiodo, disfunção nasal e de glândulas salivares estão associadas à obstrução das vias lacrimais. Observa-se uma maior porcentagem de pacientes mais jovens apresentando quadro de dacriocistite quando comparado à dacrioestenose idiopática. A absorção de iodo radioativo pela mucosa do ducto nasolacrimal com subsequente inflamação, edema e fibrose parece ter relação direta com a obstrução do ducto nasolacrimal. O conhecimento desta complicação é importante para o estudo e abordagem correta desses pacientes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Adriamycin, a commonly used antineoplastic antibiotic, induces glomerular lesions in rats, resulting in persistent proteinuria and glomerulosclerosis. We studied the effects of dietary protein and of an angiotensin I converting enzyme inhibitor on the progression of this nephropathy and the evolution of the histological lesions, as well as mesangial macromolecule flow. Adriamycin nephropathy was induced by injecting a single iv dose of adriamycin (3 mg/kg body weight) into the tail vein of male Wistar rats (weight, 180-200 g). In Experiment I animals with adriamycin-induced nephropathy were fed diets containing 6% (Low-Protein Diet Group = LPDG), 20% (Normal-Protein Diet Group = NPDG) and 40% (High-protein Diet Group = HPDG) protein and were observed for 30 weeks. In Experiment II the rats with adriamycin nephropathy were divided into 2 groups: ADR, that received adriamycin alone, and ADR-ENA, that received adriamycin plus enalapril, an angiotensin I converting enzyme inhibitor. The animals were sacrificed after a 24-week observation period. Six hours before sacrifice the animals were injected with I-131-ferritin and the amount of I-131-ferritin in the glomeruli was measured. In Experiment III, renal histology was performed 4, 8 and 16 weeks after adriamycin injection. At the end of Experiment I the tubulointerstitial lesion index was 2 for LPDG, 8 for NPDG, and 7.5 for HPDG (P<0.05); the frequency of glomerulosclerosis was 19 +/- 6.1% in LPDG, 42.6 +/- 6% in NPDG, and 54 +/- 9% in HPDG (P<0.05); and proteinuria was 61.1 +/- 25 mg/24 h in LPDG, 218.7 +/- 27.5 mg/24 h in NPDG, and 324.5 +/- 64.8 mg/24 h in HPDG (P<0.05). In Experiment II, at sacrifice, 24-h proteinuria was 189 +/- 16.1 mg in ADR, and 216 +/- 26.1 mg in ADR-ENA (P>0.05); the tubulointerstitial lesion index was 5 for ADR, and 5 for ADR-ENA (P>0.05); the frequency of glomerulosclerosis was 40 +/- 5.2% in ADR and 44 +/- 6% in ADR-ENA (P>0.05); the amount of I-131-ferritin in the mesangium was 214.26 +/- 22.71 cpm/mg protein in ADR and 253.77 +/- 69.72 cpm/mg protein in ADR-ENA (P>0.05). In Experiment III, sequential histological analysis revealed an acute tubulointerstitial cellular infiltrate at week 4, which was decreased at week 8. Tubular casts and dilatation were first seen at week 8 and increased at week 16 when few glomerular lesions were found. The results suggest that the tubulointerstitial lesions may play a role in the development of glomerulosclerosis in adriamycin-induced nephropathy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We present an approach for evaluating the efficacy of combination antitumor agent schedules that accounts for order and timing of drug administration. Our model-based approach compares in vivo tumor volume data over a time course and offers a quantitative definition for additivity of drug effects, relative to which synergism and antagonism are interpreted. We begin by fitting data from individual mice receiving at most one drug to a differential equation tumor growth/drug effect model and combine individual parameter estimates to obtain population statistics. Using two null hypotheses: (i) combination therapy is consistent with additivity or (ii) combination therapy is equivalent to treating with the more effective single agent alone, we compute predicted tumor growth trajectories and their distribution for combination treated animals. We illustrate this approach by comparing entire observed and expected tumor volume trajectories for a data set in which HER-2/neu-overexpressing MCF-7 human breast cancer xenografts are treated with a humanized, anti-HER-2 monoclonal antibody (rhuMAb HER-2), doxorubicin, or one of five proposed combination therapy schedules.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

High-spin levels of 189Pt have been studied with the in-beam γ-spectroscopy method via the 176Yb(18O,5n) reaction at the beam energies of 88 and 95 MeV. The previously known νi-131/2 band has been confirmed, and its unfavored signature branch extended up to the 13/2+ state. Within the framework of the triaxial particle-rotor model, the νi-113/2 band is suggested to be associated with the 11/2[615] configuration, and to have triaxial deformation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The outcomes for both (i) radiation therapy and (ii) preclinical small animal radio- biology studies are dependent on the delivery of a known quantity of radiation to a specific and intentional location. Adverse effects can result from these procedures if the dose to the target is too high or low, and can also result from an incorrect spatial distribution in which nearby normal healthy tissue can be undesirably damaged by poor radiation delivery techniques. Thus, in mice and humans alike, the spatial dose distributions from radiation sources should be well characterized in terms of the absolute dose quantity, and with pin-point accuracy. When dealing with the steep spatial dose gradients consequential to either (i) high dose rate (HDR) brachytherapy or (ii) within the small organs and tissue inhomogeneities of mice, obtaining accurate and highly precise dose results can be very challenging, considering commercially available radiation detection tools, such as ion chambers, are often too large for in-vivo use.

In this dissertation two tools are developed and applied for both clinical and preclinical radiation measurement. The first tool is a novel radiation detector for acquiring physical measurements, fabricated from an inorganic nano-crystalline scintillator that has been fixed on an optical fiber terminus. This dosimeter allows for the measurement of point doses to sub-millimeter resolution, and has the ability to be placed in-vivo in humans and small animals. Real-time data is displayed to the user to provide instant quality assurance and dose-rate information. The second tool utilizes an open source Monte Carlo particle transport code, and was applied for small animal dosimetry studies to calculate organ doses and recommend new techniques of dose prescription in mice, as well as to characterize dose to the murine bone marrow compartment with micron-scale resolution.

Hardware design changes were implemented to reduce the overall fiber diameter to <0.9 mm for the nano-crystalline scintillator based fiber optic detector (NanoFOD) system. Lower limits of device sensitivity were found to be approximately 0.05 cGy/s. Herein, this detector was demonstrated to perform quality assurance of clinical 192Ir HDR brachytherapy procedures, providing comparable dose measurements as thermo-luminescent dosimeters and accuracy within 20% of the treatment planning software (TPS) for 27 treatments conducted, with an inter-quartile range ratio to the TPS dose value of (1.02-0.94=0.08). After removing contaminant signals (Cerenkov and diode background), calibration of the detector enabled accurate dose measurements for vaginal applicator brachytherapy procedures. For 192Ir use, energy response changed by a factor of 2.25 over the SDD values of 3 to 9 cm; however a cap made of 0.2 mm thickness silver reduced energy dependence to a factor of 1.25 over the same SDD range, but had the consequence of reducing overall sensitivity by 33%.

For preclinical measurements, dose accuracy of the NanoFOD was within 1.3% of MOSFET measured dose values in a cylindrical mouse phantom at 225 kV for x-ray irradiation at angles of 0, 90, 180, and 270˝. The NanoFOD exhibited small changes in angular sensitivity, with a coefficient of variation (COV) of 3.6% at 120 kV and 1% at 225 kV. When the NanoFOD was placed alongside a MOSFET in the liver of a sacrificed mouse and treatment was delivered at 225 kV with 0.3 mm Cu filter, the dose difference was only 1.09% with use of the 4x4 cm collimator, and -0.03% with no collimation. Additionally, the NanoFOD utilized a scintillator of 11 µm thickness to measure small x-ray fields for microbeam radiation therapy (MRT) applications, and achieved 2.7% dose accuracy of the microbeam peak in comparison to radiochromic film. Modest differences between the full-width at half maximum measured lateral dimension of the MRT system were observed between the NanoFOD (420 µm) and radiochromic film (320 µm), but these differences have been explained mostly as an artifact due to the geometry used and volumetric effects in the scintillator material. Characterization of the energy dependence for the yttrium-oxide based scintillator material was performed in the range of 40-320 kV (2 mm Al filtration), and the maximum device sensitivity was achieved at 100 kV. Tissue maximum ratio data measurements were carried out on a small animal x-ray irradiator system at 320 kV and demonstrated an average difference of 0.9% as compared to a MOSFET dosimeter in the range of 2.5 to 33 cm depth in tissue equivalent plastic blocks. Irradiation of the NanoFOD fiber and scintillator material on a 137Cs gamma irradiator to 1600 Gy did not produce any measurable change in light output, suggesting that the NanoFOD system may be re-used without the need for replacement or recalibration over its lifetime.

For small animal irradiator systems, researchers can deliver a given dose to a target organ by controlling exposure time. Currently, researchers calculate this exposure time by dividing the total dose that they wish to deliver by a single provided dose rate value. This method is independent of the target organ. Studies conducted here used Monte Carlo particle transport codes to justify a new method of dose prescription in mice, that considers organ specific doses. Monte Carlo simulations were performed in the Geant4 Application for Tomographic Emission (GATE) toolkit using a MOBY mouse whole-body phantom. The non-homogeneous phantom was comprised of 256x256x800 voxels of size 0.145x0.145x0.145 mm3. Differences of up to 20-30% in dose to soft-tissue target organs was demonstrated, and methods for alleviating these errors were suggested during whole body radiation of mice by utilizing organ specific and x-ray tube filter specific dose rates for all irradiations.

Monte Carlo analysis was used on 1 µm resolution CT images of a mouse femur and a mouse vertebra to calculate the dose gradients within the bone marrow (BM) compartment of mice based on different radiation beam qualities relevant to x-ray and isotope type irradiators. Results and findings indicated that soft x-ray beams (160 kV at 0.62 mm Cu HVL and 320 kV at 1 mm Cu HVL) lead to substantially higher dose to BM within close proximity to mineral bone (within about 60 µm) as compared to hard x-ray beams (320 kV at 4 mm Cu HVL) and isotope based gamma irradiators (137Cs). The average dose increases to the BM in the vertebra for these four aforementioned radiation beam qualities were found to be 31%, 17%, 8%, and 1%, respectively. Both in-vitro and in-vivo experimental studies confirmed these simulation results, demonstrating that the 320 kV, 1 mm Cu HVL beam caused statistically significant increased killing to the BM cells at 6 Gy dose levels in comparison to both the 320 kV, 4 mm Cu HVL and the 662 keV, 137Cs beams.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present time-resolved spectroscopy and photometry of the double-lined eclipsing cataclysmic variable V347 Pup ( = LB 1800). There is evidence of irradiation on the inner hemisphere of the secondary star, which we correct for using a model to give a secondary-star radial velocity of K R = 198 +/- 5 km s(-1). The rotational velocity of the secondary star in V347 Pup is found to be v sin i = 131 +/- 5 km s(-1) and the system inclination is i = 84degrees.0 +/- 2degrees.3. From these parameters we obtain masses of M-1 = 0.63 +/- 0.04 M for the white dwarf primary and M-2 = 0.52 +/- 0.06 M for the M0.5V secondary star, giving a mass ratio of q = 0.83 +/- 0.05. On the basis of the component masses, and the spectral type and radius of the secondary star in V347 Pup, we find tentative evidence for an evolved companion. V347 Pup shows many of the characteristics of the SW Sex stars, exhibiting single-peaked emission lines, high-velocity S-wave components and phase-offsets in the radial velocity curve. We find spiral arms in the accretion disc of V347 Pup and measure the disc radius to be close to the maximum allowed in a pressureless disc.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La Organización Mundial de la Salud define la Medicina Nuclear como una especialidad que se ocupa del diagnóstico, tratamiento e investigación básica o clínica mediante el uso de trazadores radiactivos en medicina cuyo origen estuvo dirigido a estudios dinámicos y funcionales, realizado por primera vez en seres humano por Hevesy en 1.935. En Colombia, la medicina nuclear nace el 28 de julio de 1.955 cuando el Dr. Jaime Cortazar administra la primera dosis de I-131 en un paciente con hipetiroidismo en el Instituto Nacional de Radium, hoy en día conocido como el instituto Nacional de Cancerología. La primera gamacámaras, llegaron al país en la década de los años 70 como parte del Plan nacional hospitalario y fueron instaladas en el Instituto Nacional de Cancerología, y el hospital Militar Central, donde surgieron las primeras escuela de Medicina nuclear del país. En la actualidad, el Hospital de San José y la Fundación CardioInfaltil, también ofrecen esta profesión.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

1. Mostrar la importancia que una ciencia como la Matemática tiene en nuestros días. 2. Demostrar determinadas conexiones establecidas entre la psicología del aprendizaje y la moderna estructuración de los contenidos matemáticos. 3. Ofrecer una alternativa válida (más adecuada que la tradicional) a la Enseñanza de las Matemáticas. En concreto, se pretende averiguar si la construcción espontánea del número racional se aproxima al punto de vista del mismo basado en la idea de operador o en un concepto intuitivo de número racional. 57 alumnos de sexto de EGB y 51 alumnos de séptimo de EGB de nivel socio-económico medio. El diseño experimental corresponde al denominado de cuatro grupos: dos grupos controles y dos experimentales. Los grupos controles de sexto y séptimo de EGB trabajaron con el punto de vista basado en un concepto de número racional intuitivo y los grupos experimentales trabajaron con un punto de vista de número racional basado en la idea de operador. Se midió el rendimiento en dos pruebas de conocimientos. Prueba A sobre números racionales elaborada adhoc. Prueba B elaborada por la International Asociation for the Evaluation of Educational Achievement. Porcentajes. Se pone de manifiesto que existen entre varios grupos de alumnos diferencias notables a la hora de hacer efectivos sus conocimientos sobre el concepto y operaciones de números racionales. Así, aunque no se puede afirmar que dichas diferencias se deban a la variable tratamiento (distinta en cada caso), los datos obtenidos alegan por una mayor bondad del proceso de aprendizaje seguido por los grupos experimentales. El proceso de aprendizaje experimental ofrece más oportunidades, por la utilización de métodos basados en el descubrimiento personal del alumno. Consecuentemente facilita su desarrollo lógico basado en el propio hacer y sustituye conductas mecanicistas o automatizadas por aquellas otras en las cuales se da más opción al razonamiento.