188 resultados para Hypothermia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Arterial entrapment syndrome (AES) at elbow level is very rare and to our knowledge no case of AES by lacertus fibrosus in the cubital fossa in presence of brachial artery duplication has been described to date. We describe a rare case of acute arterial thrombosis of one of two brachial arteries highlighted in the cubital fossa which developed after strenuous right elbow flexor muscle activity and hyper-extensions presumably related to AES by lacertus fibrosus at elbow level. A 43-year-old right-handed woman, experienced paleness, coldness and numbness of the right hand, after 8 consecutive hours of gardening. As she worked, her ipsilateral flexor elbow muscles remained in prolonged and inappropriate tension. Clinical examination evidenced the absence of radial artery pulse in the wrist and mild hypothermia in the second and third finger. During surgical exploration two anastomosed brachial arteries were detected in the cubital fossa under the lacertus fibrosus. The lateral superficial brachial artery was occluded. Intraoperative arteriography evidenced brachial artery duplication at the third superior of the arm and normal vascular pattern at the forearm level. In cases of unexplained atypical intermittent upper extremity claudication or acute ischemic symptoms an AES should always be ruled out, particularly when symptoms are exacerbated by strenuous upper extremity activity or when upper limb muscular hypertrophy is evident. In these cases a thorough dynamic clinical and instrumental examination is mandatory to confirm a diagnosis of AES and to avoid possible future ischemic complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A atuação eficaz dos trabalhadores da saúde no atendimento imediato da parada cardiorrespiratória possibilita o efetivo processo de implementação da hipotermia terapêutica, reduzindo possíveis danos cerebrais e proporcionando um melhor prognóstico para o paciente. O presente estudo objetivou conhecer o processo de implementação da hipotermia terapêutica pós-parada cardiorrespiratória em hospitais do extremo sul do Brasil. Tratou-se de uma pesquisa de abordagem qualitativa, do tipo descritiva. O cenário do estudo foram duas Unidades de Terapia Intensiva de dois hospitais onde a hipotermia terapêutica pós-parada cardiorrespiratória é realizada. Os sujeitos do estudo foram médicos, enfermeiros e técnicos de enfermagem atuantes nas referidas unidades. A coleta de dados foi composta por dois momentos. Primeiramente, foi desenvolvida uma pesquisa retrospectiva nos prontuários dos pacientes e, posteriormente, foram aplicadas entrevistas semiestruturadas por meio de roteiro de entrevista com os profissionais citados, as quais foram gravadas com aparelho digital. A coleta de dados ocorreu durante o mês de outubro de 2014. Para interpretação dos dados, foi utilizada a análise textual discursiva, construindo-se três categorias. Na primeira categoria, “processo de implementação da hipotermia terapêutica”, constatou-se que o hospital com uma implementação sistematizada e organizada utiliza um protocolo escrito e, em relação às fases de aplicação da hipotermia terapêutica, ambas as instituições utilizam os métodos tradicionais de indução, manutenção e reaquecimento. A segunda categoria, “facilidades e dificuldades vivenciadas pela equipe de saúde durante a aplicação da hipotermia terapêutica”, identifica a estrutura física, harmonia da equipe, equipamentos para a monitorização constante das condições hemodinâmicas dos pacientes e a otimização do tempo de trabalho como facilitadores. No que tange às dificuldades, constatou-se a aquisição de materiais, como o gelo e o BIS; disponibilidade de um único termômetro esofágico; inexistência de EPI’s; conhecimento insuficiente e inaptidão técnica; ausência de educação permanente e dimensionamento inadequado dos profissionais de enfermagem. Na terceira categoria, “efeitos adversos e complicações encontradas pela equipe de saúde durante a aplicação da hipotermia terapêutica e cuidados de enfermagem realizados”, verificou-se, como efeitos adversos, a ocorrência de tremores, bradicardia e hipotensão e de complicações como hipotermia excessiva e queimaduras de pele. Os cuidados de enfermagem direcionam-se aos cuidados com a pele e extremidades, uso do gelo, sedação, higiene, conforto e preparo de material para monitorização. Concluiu-se que a hipotermia terapêutica é possível de ser aplicada, na realidade das instituições pesquisadas, de maneira segura, eficaz e de baixo custo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optical mapping of voltage signals has revolutionised the field and study of cardiac electrophysiology by providing the means to visualise changes in electrical activity at a high temporal and spatial resolution from the cellular to the whole heart level under both normal and disease conditions. The aim of this thesis was to develop a novel method of panoramic optical mapping using a single camera and to study myocardial electrophysiology in isolated Langendorff-perfused rabbit hearts. First, proper procedures for selection, filtering and analysis of the optical data recorded from the panoramic optical mapping system were established. This work was followed by extensive characterisation of the electrical activity across the epicardial surface of the preparation investigating time and heart dependent effects. In an initial study, features of epicardial electrophysiology were examined as the temperature of the heart was reduced below physiological values. This manoeuvre was chosen to mimic the temperatures experienced during various levels of hypothermia in vivo, a condition known to promote arrhythmias. The facility for panoramic optical mapping allowed the extent of changes in conduction timing and pattern of ventricular activation and repolarisation to be assessed. In the main experimental section, changes in epicardial electrical activity were assessed under various pacing conditions in both normal hearts and in a rabbit model of chronic MI. In these experiments, there was significant changes in the pattern of electrical activation corresponding with the changes in pacing regime. These experiments demonstrated a negative correlation between activation time and APD, which was not maintained during ventricular pacing. This suggests that activation pattern is not the sole determinant of action potential duration in intact hearts. Lastly, a realistic 3D computational model of the rabbit left ventricle was developed to simulate the passive and active mechanical properties of the heart. The aim of this model was to infer further information from the experimental optical mapping studies. In future, it would be feasible to gain insight into the electrical and mechanical performance of the heart by simulating experimental pacing conditions in the model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To identify reasons for neonatal admission and death with the aim of determining areas needing improvement. Method: A retrospective chart review was conducted on records for neonates admitted to Mulago National Referral Hospital Special Care Baby Unit (SCBU) from 1st November 2013 to 31st January 2014. Final diagnosis was generated after analyzing sequence of clinical course by 2 paediatricians. Results: A total of 1192 neonates were admitted. Majority 83.3% were in-born. Main reasons for admissions were prematurity (37.7%) and low APGAR (27.9%).Overall mortality was 22.1% (Out-born 33.6%; in born 19.8%). Half (52%) of these deaths occurred in the first 24 hours of admission. Major contributors to mortality were prematurity with hypothermia and respiratory distress (33.7%) followed by birth asphyxia with HIE grade III (24.6%) and presumed sepsis (8.7%). Majority of stable at risk neonates 318/330 (i.e. low APGAR or prematurity without comorbidity) survived. Factors independently associated with death included gestational age <30 weeks (p 0.002), birth weight <1500g (p 0.007) and a 5 minute APGAR score of < 7 (p 0.001). Neither place of birth nor delayed and after hour admissions were independently associated with mortality. Conclusion and recommendations: Mortality rate in SCBU is high. Prematurity and its complications were major contributors to mortality. The management of hypothermia and respiratory distress needs scaling up. A step down unit for monitoring stable at risk neonates is needed in order to decongest SCBU.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Resuscitated cardiac arrest (CA) patients typically receive therapeutic hypothermia, but arterial blood gases (ABGs) are often assessed after adjustment to 37°C (alpha-stat) instead of actual body temperature (pH-stat). We sought to compare alpha-stat and pH-stat assessment of PaO2 and PaCO2 in such patients. MATERIALS AND METHODS: Using ABG data obtained during the first 24 hours of intensive care unit admission, we determined the impact of measured alpha vs calculated pH-stat on PaO2 and PaCO2 on patient classification and outcomes for CA patients. RESULTS: We assessed 1013 ABGs from 120 CA patients with a median age of patients 66 years (interquartile range, 50-76). Median alpha-stat PaO2 changed from 122 (95-156) to 107 (82-143) mm Hg with pH-stat and median PaCO2 from 39 (34-46) to 35 (30-41) mm Hg (both P < .001). Using the categories of hyperoxemia, normoxemia, and hypoxemia, pH-stat estimation of PaO2 reclassified approximately 20% of patients. Using the categories of hypercapnia, normocapnia, and hypocapnia, pH stat estimation of PaCO2 reclassified approximately 40% of patients. The mortality of patients in different PaO2 and PaCO2 categories was similar for pH-stat and alpha-stat. CONCLUSIONS: Using the pH-stat method, fewer resuscitated CA patients admitted to intensive care unit were classified as hyperoxemic or hypercapnic compared with alpha-stat. These findings suggest an impact of ABG assessment methodology on PaO2, PaCO2 , and patient classification but not on associated outcomes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to investigate the effect of 22 °C local muscle temperature of intact human plantar flexors performing fatiguing contractions on evoked and voluntary contractile properties before and after fatigue. Twelve subjects were tested on plantar flexor voluntary torque, percent muscle activation derived from twitch interpolation, integrated electromyographic (iEMG) activity, and evoked torque and temporal characteristics of maximal twitch and tetanic stimulations before fatigue and 1, 5, and 10 min after intermittent, high-intensity, isometric fatigue under both normothermic and hypothermic conditions. Hypothermic and normothermic changes between time points were analysed by repeated-measures analysis of variance. Normothermic fatigue induced small to large effects (Cohen’s d: 0.29–3.06) on voluntary and evoked contractile properties, whereas most effects of unfatigued hypothermia were limited to rate-dependent processes (Cohen’s d: 0.78–1.70). Most tetanic properties were potentiated 1 min after normothermic fatigue, but remained unchanged by hypothermic fatigue, resulting in significant differences between the two conditions. Soleus iEMG significantly declined 1 min after normothermic fatigue (–29%), but not after hypothermic fatigue. Twitch torque was potentiated by 29% one minute after fatigue while normothermic, but was potentiated by 46% while hypothermic; rate of twitch torque development and time to peak twitch were potentiated by 39% and 10% while normothermic, but 89% and 28% while hypothermic. Although voluntary contractile properties are generally impaired soon after normothermic fatigue, most were not after hypothermic fatigue. Furthermore, evoked contractile properties were generally higher 1 min after hypothermic fatigue. We conclude that the hypothermic condition slows the recovery of potentiated evoked contractile properties back to baseline values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Seizures are harmful to the neonatal brain; this compels many clinicians and researchers to persevere further in optimizing every aspects of managing neonatal seizures. Aims To delineate the seizure profile between non-cooled versus cooled neonates with hypoxic-ischaemic encephalopathy (HIE), in neonates with stroke, the response of seizure burden to phenobarbitone and to quantify the degree of electroclinical dissociation (ECD) of seizures. Methods The multichannel video-EEG was used in this research study as the gold standard to detect seizures, allowing accurate quantification of seizure burden to be ascertained in term neonates. The entire EEG recording for each neonate was independently reviewed by at least 1 experienced neurophysiologist. Data were expressed in medians and interquartile ranges. Linear mixed models results were presented as mean (95% confidence interval); p values <0.05 were deemed as significant. Results Seizure burden in cooled neonates was lower than in non-cooled neonates [60(39-224) vs 203(141-406) minutes; p=0.027]. Seizure burden was reduced in cooled neonates with moderate HIE [49(26-89) vs 162(97-262) minutes; p=0.020] when compared with severe HIE. In neonates with stroke, the background pattern showed suppression over the infarcted side and seizures demonstrated a characteristic pattern. Compared with 10 mg/kg, phenobarbitone doses at 20 mg/kg reduced seizure burden (p=0.004). Seizure burden was reduced within 1 hour of phenobarbitone administration [mean (95% confidence interval): -14(-20 to -8) minutes/hour; p<0.001], but seizures returned to pre-treatment levels within 4 hours (p=0.064). The ECD index in cooled, non-cooled neonates with HIE, stroke and in neonates with other diagnoses were 88%, 94%, 64% and 75% respectively. Conclusions Further research exploring the treatment effects on seizure burden in the neonatal brain is required. A change to our current treatment strategy is warranted as we continue to strive for more effective seizure control, anchored with use of the multichannel EEG as the surveillance tool.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neonatal seizures are common in the neonatal intensive care unit. Clinicians treat these seizures with several anti-epileptic drugs (AEDs) to reduce seizures in a neonate. Current AEDs exhibit sub-optimal efficacy and several randomized control trials (RCT) of novel AEDs are planned. The aim of this study was to measure the influence of trial design on the required sample size of a RCT. We used seizure time courses from 41 term neonates with hypoxic ischaemic encephalopathy to build seizure treatment trial simulations. We used five outcome measures, three AED protocols, eight treatment delays from seizure onset (Td) and four levels of trial AED efficacy to simulate different RCTs. We performed power calculations for each RCT design and analysed the resultant sample size. We also assessed the rate of false positives, or placebo effect, in typical uncontrolled studies. We found that the false positive rate ranged from 5 to 85% of patients depending on RCT design. For controlled trials, the choice of outcome measure had the largest effect on sample size with median differences of 30.7 fold (IQR: 13.7–40.0) across a range of AED protocols, Td and trial AED efficacy (p<0.001). RCTs that compared the trial AED with positive controls required sample sizes with a median fold increase of 3.2 (IQR: 1.9–11.9; p<0.001). Delays in AED administration from seizure onset also increased the required sample size 2.1 fold (IQR: 1.7–2.9; p<0.001). Subgroup analysis showed that RCTs in neonates treated with hypothermia required a median fold increase in sample size of 2.6 (IQR: 2.4–3.0) compared to trials in normothermic neonates (p<0.001). These results show that RCT design has a profound influence on the required sample size. Trials that use a control group, appropriate outcome measure, and control for differences in Td between groups in analysis will be valid and minimise sample size.