916 resultados para Guideline Adherence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reported incidence of colonization of oropharyngeal medical devices with Candida spp. has increased in recent years, although few studies that have systematically examined the adherence of yeast cells to such biomaterials, the primary step in the process of colonization. This study, therefore, examined the effects of oropharyngeal atmospheric conditions (5% v/v carbon dioxide) and the presence of a salivary conditioning film on both the surface properties and adherence of Candida albicans, Candida krusei and Candida tropicalis to PVC and silicone. Furthermore, the effects of the salivary conditioning film on the surface properties of these biomaterials are reported. Growth of the three Candida spp. in an atmosphere containing 5% v/v CO2 significantly increased their cell surface hydrophobicity and reduced the zeta potential of C. albicans and C. krusei yet increased the zeta potential of C. tropicalis (p < 0.05). Furthermore, growth in 5% v/v CO2 decreased the adherence of C. tropicalis and C. albicans to both PVC and silicone, however, increased adherence of C. krusei (p < 0.05). Pre-treatment of the microorganisms with pooled human saliva significantly decreased their cell surface hydrophobicity and increased their adherence to either biomaterial in comparison to yeast cells that had been pre-treated with PBS (p < 0.05). Saliva treatment of the microorganisms had no consistent effect on microbial zeta potential. Interestingly, adherence of the three, saliva-treated Candida spp. to saliva-treated silicone and PVC was significantly lower than whenever the microorganisms and biomaterials had been treated with PBS (p < 0.05). Treatment of silicone and PVC with saliva significantly altered the surface properties, notably reducing both the advancing and receding contact angles and, additionally, the microrugosity. These effects may contribute to the decreased adherence of saliva-treated microorganisms to these biomaterials. In conclusion, this study has demonstrated the effects of physiological conditions within the oral cavity on the adherence of selected Candida spp. to biomaterials employed as oropharyngeal medical devices. In particular, this study has ominously shown that these materials act as substrates for yeast colonization, highlighting the need for advancements in biomaterial design. Furthermore, it is important that physiological conditions should be employed whenever biocompatibility of oropharyngeal biomaterials is under investigation. © 2001 Kluwer Academic Publishers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the resistance of biodegradable biomaterials, composed of blends of poly(e-caprolactone) (PCL) and the polymeric antimicrobial complex, polyvinylpyrrolidone–iodine (PVP-I) to the adherence of a clinical isolate of Escherichia coli is described. Blends of PCL composed of a range of high (50,000 g mol1) to low (5000 g mol1) molecular weight ratios of polymer and either
devoid of or containing PVP-I (1% w/w) were prepared by solvent evaporation. Following incubation (4 h), there was no relationship between m. wt. ratio of PCL in ?lms devoid of PVP-I and adherence ofE. coli. Conversely, microbial adherence to PCL containing PVP-I decreased as the ratio of high:low m. wt. polymer was decreased and was approximately 1000 fold lower than that to comparator ?lms devoid of PVP-I. Following periods of immersion of PVP-I containing PCL ?lms under sink conditions in phosphate buffered saline, subsequent adherence of E. coli was substantially reduced for 2 days (40:60 m. wt. ratio) and 6 days (100:0 m. wt. ratio). Concurrent exposure of PCL and E. coli to sub-minimum inhibitory concentrations (sub-MIC) of PVP-I signi?cantly reduced microbial adherence to the biomaterial; however, the molecular weight ratio of PCL did not affect this outcome. Pretreatment of PCL with similar sub-MIC of PVP-I prior to inclusion within the microbial adherence assay signi?cantly decreased the subsequent adherence of E. coli. Greatest reduction in adherence was observed following treatment of PCL (40:60 m. wt. ratio) with 0.0156% w/w PVP-I. In conclusion, this study has illustrated the utility of PVP-I as a suitable therapeutic agent for incorporation within PCL as a novel biomaterial. Due to the combined antimicrobial and biodegradable properties, these biomaterials offer a promising strategy for the reduction in medical device related infection. © 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate the factors influencing the acceptability of hip protectors to residents of nursing and residential homes, especially the effect of hip protector type, and resident characteristics. Design: A randomised controlled trial with 12 weeks follow-up. Participants were randomised to receive either Safehips or HipSaverTM hip protectors. Setting/Participants: 109 residents aged 61 to 98 years from seven residential homes and two nursing homes in Northern Ireland. Main outcome measures: Percentage day-time use of the hip protectors over 12 weeks and ongoing use at 12 weeks. Results: 42% (119/285) of residents invited to enter the studyagreed to take part, and 109 started to wear the hip protectors. 43.1% (47/109) were still using them at 12 weeks. Mean percentage day-time use for all residents during 12 weeks was 48.6%. There was no significant difference in percentage day-time use (p=0.40), or use at 12 weeks (p=0.56) between the residents wearing Safehips and HipSaverTM protectors. Greater percentage daytime use of hip protectors was associated with being resident in a home for the elderlymentallyinfirm (75.1%, pp0.0005), having a low (12 or less) Barthel score (61.1%, pp0.0005), and having been injured in a fall in the last 12 months (57.3%, p=0.012). Conclusions: The type of hip protector appeared to make no difference to their continued use by residents. Residents with a historyof a fall and those who are physicallyand mentallyincapacitated appear to be more likelyto wear hip protectors. These residents, who are at high risk of falling, are also highlydependent on nursing staff. Efforts to increase hip protector use in residential and nursing home should focus on staff, who are in the best position to advise and influence residents and their relatives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Hip protectors are protective pads designed to cover the greater trochanter and attenuate or disperse the force of a fall sufficiently to prevent a hip fracture. Promising results from randomised controlled trials in nursing homes have resulted in hip protectors being widely recommended in the health care literature and in national guidelines. Objectives: The objectives of the study were to identify characteristics of individual residents, and the organisational features of the homes in which they live, which may affect adherence to wearing hip protectors. Design: An observational, correlation study designed to identify factors related to adherence. Setting: Forty nursing and residential homes in the UK. Participants: 1346 residents of the homes who were not confined to bed and with no pressure sore on the hip. Methods: The introduction of an evidence-based policy to offer Safehips hip protectors to residents free of charge and with support from a nurse facilitator. Adherence to wearing the hip protectors was observed over 72 weeks. Results: Initial acceptance of the hip protectors was 37.2%. Continued adherence was 23.9% at 24 weeks; 23.2% at 48 weeks; and 19.9% at 72 weeks. Greater adherence was associated with the following individual resident characteristics: a greater degree of dependency (95% CI 1.39 - m3.78) and cognitive impairment (95% CI 1.01 - 2.98); being male rather than female (95% CI 1.06 - 2.48). Greater adherence was also associated with the following organisational characteristics of homes: fewer changes of senior manager during the study period (95% CI 1.01 - 8.51), and being resident in a home with a resident profile showing a greater proportion of residents with a higher degree of dependency (95% CI 1.04 - 1.27). There was wide a variation in the degree of success in implementation between homes (adherence of 0 - 100% at 24 weeks). Conclusions: Those implementing a policy of introducing hip protectors into nursing and residential homes should consider targeting residents with cognitive impairment. Such residents are at greater risk of hip fracture and appear to be more likely to continue wearing hip protectors. Those charged with implementing changes inpractice or policy should consider how the context for implementation can be optimised to increase the likelihood of success.