974 resultados para Foreign-Body Reaction


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current strategies to limit macrophage adhesion, fusion and fibrous capsule formation in the foreign body response have focused on modulating material surface properties. We hypothesize that topography close to biological scale, in the micron and nanometric range, provides a passive approach without bioactive agents to modulate macrophage behavior. In our study, topography-induced changes in macrophage behavior was examined using parallel gratings (250 nm-2 mum line width) imprinted on poly(epsilon-caprolactone) (PCL), poly(lactic acid) (PLA) and poly(dimethyl siloxane) (PDMS). RAW 264.7 cell adhesion and elongation occurred maximally on 500 nm gratings compared to planar controls over 48 h. TNF-alpha and VEGF secretion levels by RAW 264.7 cells showed greatest sensitivity to topographical effects, with reduced levels observed on larger grating sizes at 48 h. In vivo studies at 21 days showed reduced macrophage adhesion density and degree of high cell fusion on 2 mum gratings compared to planar controls. It was concluded that topography affects macrophage behavior in the foreign body response on all polymer surfaces examined. Topography-induced changes, independent of surface chemistry, did not reveal distinctive patterns but do affect cell morphology and cytokine secretion in vitro, and cell adhesion in vivo particularly on larger size topography compared to planar controls.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although the release of nitric oxide (NO) from biomaterials has been shown to reduce the foreign body response (FBR), the optimal NO release kinetics and doses remain unknown. Herein, polyurethane-coated wire substrates with varying NO release properties were implanted into porcine subcutaneous tissue for 3, 7, 21 and 42 d. Histological analysis revealed that materials with short NO release durations (i.e., 24 h) were insufficient to reduce the collagen capsule thickness at 3 and 6 weeks, whereas implants with longer release durations (i.e., 3 and 14 d) and greater NO payloads significantly reduced the collagen encapsulation at both 3 and 6 weeks. The acute inflammatory response was mitigated most notably by systems with the longest duration and greatest dose of NO release, supporting the notion that these properties are most critical in circumventing the FBR for subcutaneous biomedical applications (e.g., glucose sensors).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

COSTA MIGUEL, M. C.; NONAKA, C. F. W.; GERMANO, A. R.; SOUZA, L. B.; SOUZA, L. B. Oral foreign body granuloma: unusual presentation of a rare adverse reaction to permanent injectable cosmetic filler. International journal of oral and maxillofacial surgery, v. 38, p. 385-387, 2009.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

COSTA MIGUEL, M. C.; NONAKA, C. F. W.; GERMANO, A. R.; SOUZA, L. B.; SOUZA, L. B. Oral foreign body granuloma: unusual presentation of a rare adverse reaction to permanent injectable cosmetic filler. International journal of oral and maxillofacial surgery, v. 38, p. 385-387, 2009.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

COSTA MIGUEL, M. C.; NONAKA, C. F. W.; GERMANO, A. R.; SOUZA, L. B.; SOUZA, L. B. Oral foreign body granuloma: unusual presentation of a rare adverse reaction to permanent injectable cosmetic filler. International journal of oral and maxillofacial surgery, v. 38, p. 385-387, 2009.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There has been a continuous surge toward developing new biopolymers that exhibit better in vivo biocompatibility properties in terms of demonstrating a reduced foreign body response (FBR). One approach to mitigate the undesired FBR is to develop an implant capable of releasing anti-inflammatory molecules in a sustained manner over a long time period. Implants causing inflammation are also more susceptible to infection. In this article, the in vivo biocompatibility of a novel, biodegradable salicylic acid releasing polyester (SAP) has been investigated by subcutaneous implantation in a mouse model. The tissue response to SAP was compared with that of a widely used biodegradable polymer, poly(lactic acid-co-glycolic acid) (PLGA), as a control over three time points: 2, 4, and 16 weeks postimplantation. A long-term in vitro study illustrates a continuous, linear (zero order) release of salicylic acid with a cumulative mass percent release rate of 7.34 x 10(-4) h(-1) over similar to 1.5-17 months. On the basis of physicochemical analysis, surface erosion for SAP and bulk erosion for PLGA have been confirmed as their dominant degradation modes in vivo. On the basis of the histomorphometrical analysis of inflammatory cell densities and collagen distribution as well as quantification of proinflammatory cytokine levels (TNF-alpha and IL-1 beta), a reduced foreign body response toward SAP with respect to that generated by PLGA has been unambiguously established. The favorable in vivo tissue response to SAP, as manifest from the uniform and well-vascularized encapsulation around the implant, is consistent with the decrease in inflammatory cell density and increase in angiogenesis with time. The above observations, together with the demonstration of long-term and sustained release of salicylic acid, establish the potential use of SAP for applications in improved matrices for tissue engineering and chronic wound healing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reactions produced by the He3 bombardment of the He3 have been investigated for bombarding energies from 1 to 20 MeV using a tandem Van de Graaff accelerator. Proton spectra from the three-body reaction He3(He3, 2p)He4 have been measured with a counter telescope at 13 angles for 9 bombarding energies between 3 and 18 MeV. The results are compared with a model for the reaction which includes a strong p-He4 final-state interaction. Alpha-particle spectra have been obtained at 12 and 18 MeV for forward angles with a magnetic spectrometer. These spectra indicate a strongly forward-peaked mechanism involving the 1S0 p-p interaction in addition to the p-He4 interaction. Measurements of p-He4 and p-p coincidence spectra at 10 MeV confirm these features of the reaction mechanism. Deuteron spectra from the reaction of He3(He3, d)pHe3 have been measured at 18 MeV. A triton spectrum from the reaction He3(He3, t)3p at 20 MeV and 40 is interpreted in terms of a sequential decay through an excited state of the alpha particle at 20.0 MeV. No effects are observed which would indicate an interaction in the residual (3p) system. Below 3 MeV the He3(He3, 2p)He4 reaction mechanism is observed to be changing and further measurements are suggested in view of the importance of this reaction in stellar interiors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Inflammation and the formation of an avascular fibrous capsule have been identified as the key factors controlling the wound healing associated failure of implantable glucose sensors. Our aim is to guide advantageous tissue remodeling around implanted sensor leads by the temporal release of dexamethasone (Dex), a potent anti-inflammatory agent, in combination with the presentation of a stable textured surface.

First, Dex-releasing polyurethane porous coatings of controlled pore size and thickness were fabricated using salt-leaching/gas-foaming technique. Porosity, pore size, thickness, drug release kinetics, drug loading amount, and drug bioactivity were evaluated. In vitro sensor functionality test were performed to determine if Dex-releasing porous coatings interfered with sensor performance (increased signal attenuation and/or response times) compared to bare sensors. Drug release from coatings monitored over two weeks presented an initial fast release followed by a slower release. Total release from coatings was highly dependent on initial drug loading amount. Functional in vitro testing of glucose sensors deployed with porous coatings against glucose standards demonstrated that highly porous coatings minimally affected signal strength and response rate. Bioactivity of the released drug was determined by monitoring Dex-mediated, dose-dependent apoptosis of human peripheral blood derived monocytes in culture.

The tissue modifying effects of Dex-releasing porous coatings were accessed by fully implanting Tygon® tubing in the subcutaneous space of healthy and diabetic rats. Based on encouraging results from these studies, we deployed Dex-releasing porous coatings from the tips of functional sensors in both diabetic and healthy rats. We evaluated if the tissue modifying effects translated into accurate, maintainable and reliable sensor signals in the long-term. Sensor functionality was accessed by continuously monitoring glucose levels and performing acute glucose challenges at specified time points.

Sensors treated with porous Dex-releasing coatings showed diminished inflammation and enhanced vascularization of the tissue surrounding the implants in healthy rats. Functional sensors with Dex-releasing porous coatings showed enhanced sensor sensitivity over a 21-day period when compared to controls. Enhanced sensor sensitivity was accompanied with an increase in sensor signal lag and MARD score. These results indicated that Dex-loaded porous coatings were able to elicit a favorable tissue response, and that such tissue microenvironment could be conducive towards extending the performance window of glucose sensors in vivo.

The diabetic pilot animal study showed differences in wound healing patters between healthy and diabetic subjects. Diabetic rats showed lower levels of inflammation and vascularization of the tissue surrounding implants when compared to their healthy counterparts. Also, functional sensors treated with Dex-releasing porous coatings did not show enhanced sensor sensitivity over a 21-day period. Moreover, increased in sensor signal lag and MARD scores were present in porous coated sensors regardless of Dex-loading when compared to bare implants. These results suggest that the altered wound healing patterns presented in diabetic tissues may lead to premature sensor failure when compared to sensors implanted in healthy rats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar o efeito da suplementação com vitamina C no aumento da atividade de macrófagos e células gigantes multinucleadas (CGM), em pacus mantidos em duas densidades de estocagem. O experimento foi realizado em parcelas subdivididas, em arranjo fatorial 2x2x3 com: 0 e 500 mg kg-1 de vitamina C; densidade de estocagem de 5 e 20 kg m-3; e tempos de avaliação de 3, 6 e 12 dias após o implante subcutâneo (DPI) de lamínulas de vidro. Foram determinados o número de macrófagos e de CGM, bem como os níveis de cortisol e glicose no plasma. O número de macrófagos e de CGM com 2 a 5 núcleos foi significativamente maior nos peixes suplementados com vitamina C, à densidade 5 kg m-3, aos 3 DPI, em relação aos não suplementados. Constatou-se menor quantidade de macrófagos e CGM em peixes com baixa concentração plasmática de cortisol. A suplementação com 500 mg de vitamina C por quilograma de ração beneficia a atividade de macrófagos em inflamações do tipo corpo estranho, e a elevada concentração de cortisol circulante tem efeito supressor nesta resposta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To study cases of foreign bodies (FB) in the tracheobronchial tree investigating the clinical and radiological FB characteristics, complications and endoscopic and surgical intervention. Medical and radiological records review of all FB aspiration cases treated at S (a) over tilde uo Paulo State University Hospital over the last 30 years. One hundred and sixty-four FB cases were analyzed; 57% were male, 84% of these were under 16 years old. The most common clinical manifestations were coughing (68.3%) and choking (54.9%). The most common FBs were seeds (peanut, bean, maize) and also small metal or plastic objects. Radiography was normal in 21.3%, atelectasis was present in 40.9%, hyperinsufflation in 17.1% and the FB was radio-opaque in 20.7%. FB time in the bronchial tree varied from hours to years. The most serious complications, as fibroatelectasis and difficult resolution pneumonia, were caused by the long time that the FB remained in the bronchial tree. FB extraction was by endoscopy in 89% of cases, while 6% required surgical extraction or resection of destroyed part of lung, and 5% spontaneously eliminated the FB. There was no mortality in this series. Coughing and choking were the commonest clinical findings. Most FBs were dried seeds. Complications were due to delays in diagnosis, and most would not have existed if the doctor had given credence to the history. Radiography can be normal as most FBs are radiotransparent. FB extraction was by endoscopy, but a few cases required surgery and others were spontaneously eliminated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foreign bodies, although they are often found throughout the body, to a lesser degree in the face, still constitute a diagnostic challenge for the trauma surgeon. Its removal means danger of damaging important facial anatomic structures, even if its exact position from the image data was known. So, the objective is to describe a clinical report of a patient (42 years of age, male sex) who experienced falling to the ground, attended by the Department of Surgery and Traumatology Bucco-Maxillo-Facial Surgery, Faculty of Dentistry of Aracatuba, São Paulo State University, and 2 days after the trauma, he reported difficulty in mouth opening and pain. After clinical evaluation, we observed the presence of injury in the left preauricular region already in the process of healing. During the intraoral physical examination, a limitation of the mouth opening was noted. Radiographic posteroanterior and profile of the face showed 2 radiopaque foreign bodies in the left side, lying apparently at the region of the mandibular condylar process. Under local anesthesia, foreign body removal was carried from there with access to it through the preexisting facial injury. Further clinical examinations showed an improvement in mouth opening, absence of pain complaints, and/or functional complaints.