993 resultados para Fetal monitoring


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To assess and explain deviations from recommended practice in National Institute for Clinical Excellence (NICE) guidelines in relation to fetal heart monitoring. Design: Qualitative study. Setting: Large teaching hospital in the UK. Sample: Sixty-six hours of observation of 25 labours and interviews with 20 midwives of varying grades. Methods: Structured observations of labour and semistructured interviews with midwives. Interviews were undertaken using a prompt guide, audiotaped, and transcribed verbatim. Analysis was based on the constant comparative method, assisted by QSR N5 software. Main outcome measures: Deviations from recommended practice in relation to fetal monitoring and insights into why these occur. Results: All babies involved in the study were safely delivered, but 243 deviations from recommended practice in relation to NICE guidelines on fetal monitoring were identified, with the majority (80%) of these occurring in relation to documentation. Other deviations from recommended practice included indications for use of electronic fetal heart monitoring and conduct of fetal heart monitoring. There is evidence of difficulties with availability and maintenance of equipment, and some deficits in staff knowledge and skill. Differing orientations towards fetal monitoring were reported by midwives, which were likely to have impacts on practice. The initiation, management, and interpretation of fetal heart monitoring is complex and distributed across time, space, and professional boundaries, and practices in relation to fetal heart monitoring need to be understood within an organisational and social context. Conclusion: Some deviations from best practice guidelines may be rectified through straightforward interventions including improved systems for managing equipment and training. Other deviations from recommended practice need to be understood as the outcomes of complex processes that are likely to defy easy resolution. © RCOG 2006.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Health monitoring has become widespread these past few years. Such applications include from exercise, food intake and weight watching, to specific scenarios like monitoring people who suffer from chronic diseases. More and more we see the need to also monitor the health of new-born babies and even fetuses. Congenital Heart Defects (CHDs) are the main cause of deaths among babies and doctors do not know most of these defects. Hence, there is a need to study what causes these anomalies, and by monitoring the fetus daily there will be a better chance of identifying the defects in earlier stages. By analyzing the data collected, doctors can find patterns and come up with solutions, thus saving peoples’ lives. In many countries, the most common fetal monitor is the ultrasound and the use of it is regulated. In Sweden for normal pregnancies, there is only one ultrasound scan during the pregnancy period. There is no great evidence that ultrasound can harm the fetus, but many doctors suggest to use it as little as possible. Therefore, there is a demand for a new non-ultrasound device that can be as accurate, or even better, on detecting the FHR and not harming the baby. The problems that are discussed in this thesis include how can accurate fetus health be monitored non-invasively at home and how could a fetus health monitoring system for home use be designed. The first part of the research investigates different technologies that are currently being used on fetal monitoring, and techniques and parameters to monitor the fetus. The second part is a qualitative study held in Sweden between April and May 2016. The data for the qualitative study was collected through interviews with 21 people, 10 mothers/mothers-to-be and 11 obstetricians/gynecologists/midwives. The questions were related to the Swedish pregnancy protocol, the use of technology in medicine and in particular during the pregnancy process, and the use of an ECG based monitoring device. The results show that there is still room for improvements on the algorithms to extract the fetal ECG and the survey was very helpful in understanding the need for a fetal home monitor. Parents are open to new technologies especially if it doesn't affect the baby's growth. Doctors are open to use ECG as a great alternative to ultrasound; on the other hand, midwives are happy with the current system. The remote monitoring feature is very desirable to everyone, if such system will be used in the future.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introducción: Después del ingreso de la monitoría fetal electrónica como estudio de bienestar fetal, se ha considerado por décadas que un aporte de carbohidratos a la gestante antes de la realización de la monitoría fetal influye en el reporte pero existen estudios que consideran que los niveles de glicemia materna no afecta la variabilidad de la monitoría fetal. Metodología: Se realizó un estudio de corte transversal, para evaluar el efecto de la glicemia materna en la monitoría fetal electrónica comparando los valores de glicemia materna con su resultado, según la categorización del ACOG. Las principales variables fueron las horas de ayuno, valores de glicemia, variabilidad de la monitoría fetal y presencia de aceleraciones. Resultados: Se incluyeron un total de 60 pacientes, que ingresaron al servicio de obstetricia y ginecología del Hospital Universitario Mayor Méderi en el periodo de estudio. No se encontraron diferencias estadísticamente significativas entre los resultados de monitoría fetal y los valores de glicemia materna. Ninguna paciente presentó monitoría categoría III (según categorización de la ACOG). Discusión Se requieren estudios analíticos más amplios para evaluar el papel de la glicemia en el resultado de la monitoría, pero el presente estudio sugiere que no existe relación entre la glicemia materna y el resultado de la monitoría fetal electrónica en la categorización del Colegio Americano De Ginecología Y Obstetricia (ACOG).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Fetal scalp lactate testing has been shown to be as useful as pH with added benefits. One remaining question is What level of lactate should trigger intervention in the first stage of labour?' Aims: This study aimed to establish the lactate level in the first stage of labour that indicates the need for intervention to ensure satisfactory outcomes for both babies and mothers. Methods: A prospective study at Mater Mothers' Hospital, Brisbane, Australia, a tertiary referral centre. One hundred and forty women in labour, with non-reassuring fetal heart rate traces, were tested using fetal blood scalp sampling of 5 mu L of capillary blood tested on an Accusport (Boeringer, Mannheim, East Sussex, UK) lactate meter. Decision to intervene in labour was based on clinical assessment plus a predetermined cut off. Main outcome measures were APGAR scores, cord arterial pH, meconium stained liquor and Intensive Care Nursery admission. Results: Two-graph receiver operating characteristic (TG-ROC) analysis showed optimal specificity, and sensitivity for predicting adverse neonatal outcomes was a scalp lactate level above 4.2 mmol/L. Conclusions: Fetal blood sampling remains the standard for further investigating-non-reassuring cardiotocograph (CTG) traces. Even so, it is a poor predictor of fetal outcomes. Scalp lactate has been shown to be at least as good a predictor as scalp pH, with the advantages of being easier, cheaper and with a lower rate of technical failure. Our study, found that a cut off fetal scalp lactate level of 4.2 mmol/L, in combination with an assessment of the entire clinical picture, is a useful tool in identifying those women who need intervention.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Fetal pulse oximetry (FPO) may improve the assessment of the fetal well-being in labour. Reports of health-care provider's evaluations of new technology are important in the overall evaluation of that technology. Aims: To determine doctors' and midwives' perceptions of their experience placing FPO sensors. Methods: We surveyed clinicians (midwives and doctors) following placement of a FPO sensor during the FOREMOST trial (multicentre randomised trial of fetal pulse oximetry). Clinicians rated ease of sensor placement (poor, fair, good and excellent). Potential influences on ease of sensor placement (staff category, prior experience in Birth Suite, prior experience in placing sensors, epidural analgesia, cervical dilatation and fetal station) were examined by ordinal regression. Results: There were 281 surveys returned for the 294 sensor placement attempts (response rate 96%). Sensors were placed by midwives (29%), research midwives (48%), registrars (22%) and obstetricians (1%). The majority of clinicians had 1 or more years' Birth Suite experience, had placed six or more sensors previously, and rated ease of sensor placement as good. Advancing fetal station (P < 0.001) and the presence of epidural analgesia prior to sensor placement (P = 0.029) predicted improved ease of sensor placement. Having a clinician placing a sensor for the first time predicted a lower rating for ease of sensor placement (P = 0.001), compared to having placed one or more sensors previously. Conclusions: Clinicians with varying levels of Birth Suite experience successfully placed fetal oxygen saturation sensors, with the majority rating ease of sensor placement as good.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Women born outside Australia make up more than a fifth of the Queensland birthing population and like migrants in other parts of the world face the challenges of cultural dislocation and possible language barriers. Recognising that labour and birth are major life events the aim was to investigate the experiences of these women in comparison to native-born English speaking women. Methods Secondary analysis of data from a population based survey of women who had recently birthed in Queensland. Self-reported clinical outcomes and quality of interpersonal care of 481 women born outside Australia who spoke a language other than English at home were compared with those of 5569 Australian born women speaking only English. Results After adjustment for demographic factors and type of birthing facility, women born in another country were less likely to be induced, but more likely to have constant electronic fetal monitoring (EFM), to give birth lying on their back or side, and to have an episiotomy. Most women felt that they were treated as an individual and with kindness and respect. However, women born outside Australia were less likely to report being looked after ‘very well’ during labour and birth and to be more critical of some aspects of care. Conclusion In comparing the labour and birth experiences of women born outside the country who spoke another language with native-born English speaking women, the present study presents a largely positive picture. However, there were some marked differences in both clinical and interpersonal aspects of care.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Currently, care providers and policy-makers internationally are working to promote normal birth. In Australia, such initiatives are being implemented without any evidence of the prevalence or determinants of normal birth as a multidimensional construct. This study aimed to better understand the determinants of normal birth (defined as without induction of labour, epidural/spinal/general anaesthesia, forceps/vacuum, caesarean birth, or episiotomy) using secondary analyses of data from a population survey of women in Queensland, Australia. Methods Women who birthed in Queensland during a two-week period in 2009 were mailed a survey approximately three months after birth. Women (n=772) provided retrospective data on their pregnancy, labour and birth preferences and experiences, socio-demographic characteristics, and reproductive history. A series of logistic regressions were conducted to determine factors associated with having labour, having a vaginal birth, and having a normal birth. Findings Overall, 81.9% of women had labour, 66.4% had a vaginal birth, and 29.6% had a normal birth. After adjusting for other significant factors, women had significantly higher odds of having labour if they birthed in a public hospital and had a pre-existing preference for a vaginal birth. Of women who had labour, 80.8% had a vaginal birth. Women who had labour had significantly higher odds of having a vaginal birth if they attended antenatal classes, did not have continuous fetal monitoring, felt able to ‘take their time’ in labour, and had a pre-existing preference for a vaginal birth. Of women who had a vaginal birth, 44.7% had a normal birth. Women who had a vaginal birth had significantly higher odds of having a normal birth if they birthed in a public hospital, birthed outside regular business hours, had mobility in labour, did not have continuous fetal monitoring, and were non-supine during birth. Conclusions These findings provide a strong foundation on which to base resources aimed at increasing informed decision-making for maternity care consumers, providers, and policy-makers alike. Research to evaluate the impact of modifying key clinical practices (e.g., supporting women׳s mobility during labour, facilitating non-supine positioning during birth) on the likelihood of a normal birth is an important next step.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objetivo: Determinar los factores de riesgo de anteparto, intraparto y fetales asociados a asfixia perinatal en los recién nacidos del servicio de neonatología del Hospital Universitario Mayor Méderi de Bogotá, 2010-2011. Materiales y métodos: Estudio de casos y controles pareado por fecha de nacimiento, con una relación 1:5(51:306). Las asociaciones se evaluaron con la prueba de ji-cuadrado de Mantel y Haenszel o Test de Fisher para datos pareados, con OR e intervalo de confianza del 95%, el análisis multivariado con un modelo de regresión logística condicional. Resultados: Los factores de riesgo con asociación significativa fueron: - Ante parto: Antecedentes patológicos maternos (OR=6.00,IC95%:1.55-23.19,p=0.013), primigestación (OR=1.91,IC95%:1.02-3.56,p=0,090), -Intraparto: Abruptio de placenta (OR=25,00,IC95%:2.92-213.99,p=0.001), hemorragia del tercer trimestre (OR=12.50,IC95%:2.43-64.43,p=0.001), Oligohidramnios(OR=6.25,IC95%:1.68-23.28,p=0.001), taquicardia fetal (OR=7.66,IC95%:1.67-35.04,p=0.011), monitoreo fetal intraparto anormal (OR=10.33,IC95%:4.38-24.34,p=0.001), expulsivo prolongado(OR=13.00,IC95%:4.63-36.46,p=0.001), fiebre materna(p<0.001), corioamnionitis(p<0.001), convulsiones maternas(p<0.001), bradicardia fetal (p=<0.001), -Fetales: Género masculino(OR=1.87,IC95%:1.02-3.44,p=0.026), edad gestacional por BALLARD igual ó <36semanas(OR=4.78(IC95%:2.21-10.35,p=0.001), vía del nacimiento instrumentado(OR=18,80,IC95%:3.69-39.55,p=0.001), líquido amniótico hemorrágico o teñido de meconio(OR= 9.00,IC95%:3.01-26.85,p=0.001), circular de cordón(OR=9.00,IC95%:3.59-22.52,p=0.001), peso al nacer igual ó <2500 gramos (OR=8.88,IC95%:3.73-21.15,p=0.001). Los subrayados y el síndrome hipertensivo asociado al embarazo se encontraron significativos en análisis multivariado. Conclusiones: Los factores de riesgo para asfixia perinatal fueron: antecedentes patológicos maternos, primigestación, abruptio de placenta, hemorragia del tercer trimestre, oligohidramnios, monitoreo fetal intraparto anormal, taquicardia y bradicardia fetal, expulsivo prolongado, corioamnionitis, fiebre materna, convulsiones maternas, género masculino, edad gestacional por BALLARD igual ó <36 semanas, vía del nacimiento instrumentado, líquido amniótico hemorrágico o teñido de meconio, circular de cordón, peso al nacer igual ó <2500 gramos.