991 resultados para Eye artificial


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Prosthetic eyes are artificial substitutes for the eyeball, made of heat-curing acrylic resin, serving to improve the esthetic appearance of the mutilated patient and his/her inclusion in society. The aim of this study was to assess the flexural strength of two heat-curing acrylic resins used for manufacturing prosthetic eyes. Thirty-six specimens measuring 64 x 10 x 3.3 mm were obtained and divided into four groups: acrylic resin for artificial sclera N1 (Artigos Odontológicos Clássico, São Paulo, SP, Brazil), heat-cure water technique (GI) and microwave-cured (GII); colorless acrylic resin for prosthetic eyes (Artigos Odontológicos Clássico, São Paulo, SP, Brazil), heat-cure water technique (GIII) and microwave-cured (GIV). Mechanical tests using three point loads were performed in a test machine (EMIC, São José dos Pinhais, PR, Brazil). The analysis of variance and the Tukey test were used to identify significant differences (p < 0.01). Groups GII and GIV presented, respectively, the highest (98.70 ± 11.90 MPa) and lowest means (71.07 ± 8.93 MPa), with a statistically significant difference. The cure method used for the prosthetic eye resins did not interfere in their flexural strength. It was concluded that all the resins assessed presented sufficient flexural strength values to be recommended for the manufacture of prosthetic eyes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Foram eviscerados os globos oculares esquerdos de 32 ratos, linhagem Wistar, divididos em quatro grupos (A, B, C, D) constituídos, cada um, de cinco testemunhas e três controles. Nos animais-testemunha introduziu-se, dentro da capa córneo-escleral, uma esfera de resina acrílica (metilmetacrilato), previamente confeccionada e esterilizada por autoclavagem, ao passo que nos controles a cavidade eviscerada foi mantida sem prótese. Os ratos dos grupos A, B, C e D foram sacrificados respectivamente aos 7, 15, 30 e 90 dias de pós-operatório, quando os conteúdos orbitários esquerdos foram exenterados e preparados para o exame histopatológico. Observou-se que os animais-testemunha tiveram resposta inflamatória do tipo tecido de granulação ao redor da prótese de cavidade, com edema inflamatório da córnea especialmente nos grupos A e B, quando se iniciou a regressão da inflamação aguda. A cavidade orbitária manteve o tamanho em todos os grupos nos animais-testemunha e houve contração significativa nos animais-controle. Com estas observações, foi possível concluir que a esfera de resina acrílica é uma opção, de baixo custo e fácil confecção, para correção de defeito estético causado pela perda do globo ocular.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To determine the most common approach to repair the anophthalmic socket in Brazil, and to compare the data with the trends in other countries.Methods: Exploratory study using electronic questionnaire sent by Internet to ophthalmologists members of the Brazilian Orbit and Oculoplastic Society (SBCPO). The received answers were analyzed by adhesion analysis, using Chi-square test.Results: We received 75 answered questionnaires. Fifty-three per cent of the respondents frequently treat anophthalmic socket and use the 18 mm diameter polymethylmethacrylate sphere in the majority of the surgeries, mainly covered by sclera (92%). Only seven interviewees had used integrated implants with pegging procedure. Eighty-two per cent of the ophthalmologists use the dermolipid graft to reconstruct the anophthalmic socket. They also follow the patients bi annually.Conclusions: The treatment of anophthalmic socket in Brazil generally involve polymethylmethacrylate sphere with 18 mm diameter. Pegging procedure is uncommon between us.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The patient with anophthalmia may present feelings of inferiority and rejection. Knowing his/her needs and expectations contribute to a better technical intervention. Purpose: To elaborate a questionnaire of the psychosocial profile of the patient with anophthalmia with indication of ocular prosthesis. Methods: An exploratory research was used to elaborate the questionnaire, by means of a guided interview followed by writing down what was said by the interviewees, who were adult patients of the Bucco-Maxillo-Facial Prosthesis Center of FOSJC - UNESP. The guided interview was made up of 14 items directly related to the future outline of the profile. Each item of the interview resulted in questions of the questionnaire, which was pretested twice before reaching its final version. Results: The patients reported, in the exploratory research, unpleasant feelings with the loss of the eye; relationship shyness; expectations regarding surgery and prosthesis use; a wish to receive explanations and to hold their opinion about the treatment. The questionnaire of the psychosocial profile of the patient with anophthalmia with indication of ocular prosthesis is, therefore, made of 43 questions divided into 5 blocks in order to aid the comprehension of the inquired aspects and to facilitate both the computation of data and discussion, and also to improve the selection of questions according to the objective of the researcher or professional. Conclusions: It was concluded that the questionnaire was viable, can be used in full or by selecting blocks and provide a panorama of the patient's history related to the problem he/she faces, from the loss of the ocular globe to the confection of the prosthesis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to assess color alteration of the paints used for iris painting in artificial eyes. Five disks of heat cured acrylic resin were confectioned by microwave energy for each paint analyzed, in a total of 40 specimens. Each specimen consisted of a colorless acrylic resin disk and another of equal size, of scleral white colored acrylic resin, with the painting interposed between the two disks. The specimens were submitted to an accelerated aging process in a chamber under ultraviolet radiation for 1,008 hours. To assess color variation, a reflective spectrophotometer was used. The results were statistically analyzed by ANOVA and the Tukey test (p < 0.05). All the paints underwent chromatic alteration. The oil paint presented the highest resistance to accelerated aging.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to assess the improvement in psychosocial awareness of anophthalmic patients wearing ocular prostheses and its relationship with demographic characteristics, factors of loss/treatment, social activity, and relationship between professional and patient. Surveys including a form for evaluation of psychosocial pattern were conducted with 40 anophthalmic patients rehabilitated with ocular prosthesis at the Center of Oral Oncology in the authors' dental school from January 1998 to November 2010. The improvement in psychosocial awareness was assessed by comparing the perception of some feelings reported in the period of eye loss and currently. Wilcoxon tests were applied for comparison of patients' perception between the periods. χ2 tests were used to assess the relationship between the improvement in psychosocial awareness and the variables of the study. In addition, the logistic regression model measured this relationship with the measure of odds ratio. The feelings of shame, shyness, preoccupation with hiding it, sadness, insecurity and fear were significant for improvement in psychosocial awareness. It was concluded that the anophthalmic patients wearing an ocular prosthesis has significant improvement in psychosocial awareness after rehabilitation. © 2012 International Association of Oral and Maxillofacial Surgeons.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dry eye disease is a common clinical condition whose aetiology and management challenges clinicians and researchers alike. Practitioners have a number of dry eye tests available to clinically assess dry eye disease, in order to treat their patients effectively and successfully. This thesis set out to determine the most relevant and successful key tests for dry eye disease diagnosis/ management. There has been very little research on determining the most effective treatment options for these patients; therefore a randomised controlled study was conducted in order to see how different artificial treatments perform compared to each other, whether the preferred treatment could have been predicted from their ocular clinical assessment, and if the preferred treatment subjectively related to the greatest improvement in ocular physiology and tear film stability. This research has found: 1. From the plethora of ocular the tear tests available to utilise in clinical practice, the tear stability tests as measured by the non-invasive tear break (NITBUT) up time and invasive tear break up time (NaFL TBUT) are strongly correlated. The tear volume tests are also related as measured by the phenol red thread (PRT) and tear meniscus height (TMH). Lid Parallel Conjunctival Folds (LIPCOF) and conjunctival staining are significantly correlated to one another. Symptomology and osmolarity were also found to be important tests in order to assess for dry eye. 2. Artificial tear supplements do work for ocular comfort, as well as the ocular surface as observed by conjunctival staining and the reduction LIPCOF. There is no strong evidence of one type of artificial tear supplement being more effective than others, and the data suggest that these improvements are more due to the time than the specific drops. 3. When trying to predict patient preference for artificial tears from baseline measurements, the individual category of artificial tear supplements appeared to have an improvement in at least 1 tear metric. Undoubtedly, from the study the patients preferred artificial tear supplements’ were rated much higher than the other three drops used in the study and their subjective responses were statistically significant than the signs. 4. Patients are also willing to pay for a community dry eye service in their area of £17. In conclusion, the dry eye tests conducted in the study correlate with one another and with the symptoms reported by the patient. Artificial tears do make a difference objectively as well as subjectively. There is no optimum artificial treatment for dry eye, however regular consistent use of artificial eye drops will improve the ocular surface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article the authors continue the Artificial Intelligence and the law debate begun with Moles' 1991 article. In it the authors answer the latest criticisms made by Moles and others as they explain and argue the case for the practical benefits to be gained by AI systems involving the law.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For goldfish (Carassius auratus), there are many varieties with different eye phenotypes due to artificial selection and adaptive evolution. Dragon eye is a variant eye characterized by a large-size eyeball protruding out of the socket similar to the eye of dragon in Chinese legends. In this study, anatomical structure of the goldfish dragon eye was compared with that of the common eye, and a stretching of the retina was observed in the enlarged dragon eye. Moreover, the homeobox-containing transcription factor Six3 cDNAs were cloned from the two types of goldfish, and the expression patterns were analyzed in both normal eye and dragon eye goldfish. No amino acid sequence differences were observed between the two deduced peptides, and the expression pattern of Six3 protein in dragon eye is quite similar to common eye during embryogenesis, but from 2 days after hatching, ectopic Six3 expression began to occur in the dragon eye, especially in the outer nuclear layer cells. With eye development, more predominant Six3 distribution was detected in the outer nuclear layer cells of dragon eye than that of normal eye, and fewer cell-layers in outer nuclear layer were observed in dragon eye retina than in normal eye retina. The highlight of this study is that higher Six3 expression occurs in dragon eye goldfish than in normal eye goldfish during retinal development of larvae. (C) 2007 Elsevier Inc. All rights reserved.