984 resultados para Esophageal transit time


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A hybrid magnetic instrumentation to detect a magnetic field from a permanent magnet, and to detect magnetic markers and tracers using alternating current biosusceptometry (ACB) is discussed. The instrument was used to in vitro evaluation of the esophageal transit time. The sensitivity between both magnetic methods was compared, showing sensitivity for in vivo applications. © 2013 Springer-Verlag.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study objectives: Currently, esophageal pressure monitoring is the "gold standard" measure for inspiratory efforts, hut its invasive nature necessitates a better tolerated and noninvasive method to be used on children. Pulse transit time (PTT) has demonstrated its potential as a noninvasive surrogate marker for inspiratory efforts. The principle velocity determinant of PTT is the change in stiffness of the arterial wall and is inversely correlated to BP. Moreover, PTT has been shown to identify changes in inspiratory effort via the BP fluctuations induced by negative pleural pressure swings. In this study, the capability of PTT to classify respiratory, events during sleep as either central or obstructive in nature was investigated. Setting and participants: PTT measure was used in adjunct to routine overnight polysomnographic studies performed on 33 children (26 boys and 7 girls; mean +/- SD age, 6.7 +/- 3.9 years). The accuracy of PTT measurements was then evaluated against scored corresponding respiratory events in the polysomnography recordings. Results: Three hundred thirty-four valid respiratory events occurred and were analyzed. One hundred twelve obstructive events (OEs) showed a decrease in mean PTT over a 10-sample window that had a probability of being correctly ranked below the baseline PTT during tidal breathing of 0.92 (p < 0.005); 222 central events (CEs) showed a decrease in the variance of PTT over a 10-sample window that had a probability of being ranked below the baseline PTT of 0.94 (p < 0.005). This indicates that, at a sensitivity of 0.90, OEs can be detected with a specificity of 0.82 and CEs can be detected with a specificity of 0.80. Conclusions: PTT is able to categorize CEs and OEs accordingly in the absence of motion artifacts, including hypopneas. Hence, PTT shows promise to differentiate respiratory, events accordingly and can be an important diagnostic tool in pediatric respiratory sleep studies.< 0.005); 222 central events (CEs) showed a decrease in the variance of PTT over a 10-sample window that had a probability of being ranked below the baseline PTT of 0.94 (p < 0.005). This indicates that, at a sensitivity of 0.90, OEs can be detected with a specificity of 0.82 and CEs can be detected with a specificity of 0.80. Conclusions: PTT is able to categorize CEs and OEs accordingly in the absence of motion artifacts, including hypopneas. Hence, PTT shows promise to differentiate respiratory, events accordingly and can be an important diagnostic tool in pediatric respiratory sleep studies.');"

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The measurement of broadband ultrasonic attenuation (BUA) in cancellous bone for the assessment of osteoporosis follows a parabolic-type dependence with bone volume fraction; having minima values corresponding to both entire bone and entire marrow. Langton has recently proposed that the primary BUA mechanism may be significant phase interference due to variations in propagation transit time through the test sample as detected over the phase-sensitive surface of the receive ultrasound transducer. This fundamentally simple concept assumes that the propagation of ultrasound through a complex solid : liquid composite sample such as cancellous bone may be considered by an array of parallel ‘sonic rays’. The transit time of each ray is defined by the proportion of bone and marrow propagated, being a minimum (tmin) solely through bone and a maximum (tmax) solely through marrow. A Transit Time Spectrum (TTS), ranging from tmin to tmax, may be defined describing the proportion of sonic rays having a particular transit time, effectively describing lateral inhomogeneity of transit time over the surface of the receive ultrasound transducer. Phase interference may result from interaction of ‘sonic rays’ of differing transit times. The aim of this study was to test the hypothesis that there is a dependence of phase interference upon the lateral inhomogenity of transit time by comparing experimental measurements and computer simulation predictions of ultrasound propagation through a range of relatively simplistic solid:liquid models exhibiting a range of lateral inhomogeneities. Methods: A range of test models was manufactured using acrylic and water as surrogates for bone and marrow respectively. The models varied in thickness in one dimension normal to the direction of propagation, hence exhibiting a range of transit time lateral inhomogeneities, ranging from minimal (single transit time) to maximal (wedge; ultimately the limiting case where each sonic ray has a unique transit time). For the experimental component of the study, two unfocused 1 MHz ¾” broadband diameter transducers were utilized in transmission mode; ultrasound signals were recorded for each of the models. The computer simulation was performed with Matlab, where the transit time and relative amplitude of each sonic ray was calculated. The transit time for each sonic ray was defined as the sum of transit times through acrylic and water components. The relative amplitude considered the reception area for each sonic ray along with absorption in the acrylic. To replicate phase-sensitive detection, all sonic rays were summed and the output signal plotted in comparison with the experimentally derived output signal. Results: From qualtitative and quantitative comparison of the experimental and computer simulation results, there is an extremely high degree of agreement of 94.2% to 99.0% between the two approaches, supporting the concept that propagation of an ultrasound wave, for the models considered, may be approximated by a parallel sonic ray model where the transit time of each ray is defined by the proportion of ‘bone’ and ‘marrow’. Conclusions: This combined experimental and computer simulation study has successfully demonstrated that lateral inhomogeneity of transit time has significant potential for phase interference to occur if a phase-sensitive ultrasound receive transducer is implemented as in most commercial ultrasound bone analysis devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The acceptance of broadband ultrasound attenuation for the assessment of osteoporosis suffers from a limited understanding of ultrasound wave propagation through cancellous bone. It has recently been proposed that the ultrasound wave propagation can be described by a concept of parallel sonic rays. This concept approximates the detected transmission signal to be the superposition of all sonic rays that travel directly from transmitting to receiving transducer. The transit time of each ray is defined by the proportion of bone and marrow propagated. An ultrasound transit time spectrum describes the proportion of sonic rays having a particular transit time, effectively describing lateral inhomogeneity of transit times over the surface of the receiving ultrasound transducer. The aim of this study was to provide a proof of concept that a transit time spectrum may be derived from digital deconvolution of input and output ultrasound signals. We have applied the active-set method deconvolution algorithm to determine the ultrasound transit time spectra in the three orthogonal directions of four cancellous bone replica samples and have compared experimental data with the prediction from the computer simulation. The agreement between experimental and predicted ultrasound transit time spectrum analyses derived from Bland–Altman analysis ranged from 92% to 99%, thereby supporting the concept of parallel sonic rays for ultrasound propagation in cancellous bone. In addition to further validation of the parallel sonic ray concept, this technique offers the opportunity to consider quantitative characterisation of the material and structural properties of cancellous bone, not previously available utilising ultrasound.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent studies have shown that ultrasound transit time spectroscopy (UTTS) is an alternative method to describe ultrasound wave propagation through complex samples as an array of parallel sonic rays. This technique has the potential to characterize bone properties including volume fraction and may be implemented in clinical systems to predict osteoporotic fracture risk. In contrast to broadband ultrasound attenuation, which is highly frequency dependent, we hypothesise that UTTS is frequency independent. This study measured 1 MHz and 5 MHz broadband ultrasound signals through a set of acrylic step-wedge samples. Digital deconvolution of the signals through water and each sample was applied to derive a transit time spectrum. The resulting spectra at both 1 MHz and 5 MHz were compared to the predicted transit time values. Linear regression analysis yields agreement (R2) of 99.23% and 99.74% at 1 MHz and 5 MHz respectively indicating frequency independence of transit time spectra.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Considering ultrasound propagation through complex composite media as an array of parallel sonic rays, a comparison of computer simulated prediction with experimental data has previously been reported for transmission mode (where one transducer serves as transmitter, the other as receiver) in a series of ten acrylic step-wedge samples, immersed in water, exhibiting varying degrees of transit time inhomogeneity. In this study, the same samples were used but in pulse-echo mode, where the same ultrasound transducer served as both transmitter and receiver, detecting both ‘primary’ (internal sample interface) and ‘secondary’ (external sample interface) echoes. A transit time spectrum (TTS) was derived, describing the proportion of sonic rays with a particular transit time. A computer simulation was performed to predict the transit time and amplitude of various echoes created, and compared with experimental data. Applying an amplitude-tolerance analysis, 91.7±3.7% of the simulated data was within ±1 standard deviation (STD) of the experimentally measured amplitude-time data. Correlation of predicted and experimental transit time spectra provided coefficients of determination (R2) ranging from 100.0% to 96.8% for the various samples tested. The results acquired from this study provide good evidence for the concept of parallel sonic rays. Further, deconvolution of experimental input and output signals has been shown to provide an effective method to identify echoes otherwise lost due to phase cancellation. Potential applications of pulse-echo ultrasound transit time spectroscopy (PE-UTTS) include improvement of ultrasound image fidelity by improving spatial resolution and reducing phase interference artefacts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The acceptance of broadband ultrasound attenuation (BUA) for the assessment of osteoporosis suffers from a limited understanding of both ultrasound wave propagation through cancellous bone and its exact dependence upon the material and structural properties. It has recently been proposed that ultrasound wave propagation in cancellous bone may be described by a concept of parallel sonic rays; the transit time of each ray defined by the proportion of bone and marrow propagated. A Transit Time Spectrum (TTS) describes the proportion of sonic rays having a particular transit time, effectively describing the lateral inhomogeneity of transit times over the surface aperture of the receive ultrasound transducer. The aim of this study was to test the hypothesis that the solid volume fraction (SVF) of simplified bone:marrow replica models may be reliably estimated from the corresponding ultrasound transit time spectrum. Transit time spectra were derived via digital deconvolution of the experimentally measured input and output ultrasonic signals, and compared to predicted TTS based on the parallel sonic ray concept, demonstrating agreement in both position and amplitude of spectral peaks. Solid volume fraction was calculated from the TTS; agreement between true (geometric calculation) with predicted (computer simulation) and experimentally-derived values were R2=99.9% and R2=97.3% respectively. It is therefore envisaged that ultrasound transit time spectroscopy (UTTS) offers the potential to reliably estimate bone mineral density and hence the established T-score parameter for clinical osteoporosis assessment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quality of ultrasound computed tomography imaging is primarily determined by the accuracy of ultrasound transit time measurement. A major problem in analysis is the overlap of signals making it difficult to detect the correct transit time. The current standard is to apply a matched-filtering approach to the input and output signals. This study compares the matched-filtering technique with active set deconvolution to derive a transit time spectrum from a coded excitation chirp signal and the measured output signal. The ultrasound wave travels in a direct and a reflected path to the receiver, resulting in an overlap in the recorded output signal. The matched-filtering and deconvolution techniques were applied to determine the transit times associated with the two signal paths. Both techniques were able to detect the two different transit times; while matched-filtering has a better accuracy (0.13 μs vs. 0.18 μs standard deviation), deconvolution has a 3.5 times improved side-lobe to main-lobe ratio. A higher side-lobe suppression is important to further improve image fidelity. These results suggest that a future combination of both techniques would provide improved signal detection and hence improved image fidelity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study reports a noninvasive technique for the measurement of the pulse transit time differential (PTTD) from the pulse pressure waveforms obtained at the carotid artery and radial artery using fiber Bragg grating pulse recorders (FBGPR). PTTD is defined as the time difference between the arrivals of a pulse pressure waveform at the carotid and radial arterial sites. The PTTD is investigated as an indicator of variation in the systolic blood pressure. The results are validated against blood pressure variation obtained from a Mindray Patient Monitor. Furthermore, the pulse wave velocity computed from the obtained PTTD is compared with the pulse wave velocity obtained from the color Doppler ultrasound system and is found to be in good agreement. The major advantage of the PTTD measurement via FBGPRs is that the data acquisition system employed can simultaneously acquire pulse pressure waveforms from both FBGPRs placed at carotid and radial arterial sites with a single time scale, which eliminates time synchronization complexity. (C) 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accurate measurement of transit time for acoustic wave between two sensors installed on two sides of a furnace is a key to implementing the temperature field measurement technique based on acoustical method. A new method for measuring transit time of acoustic wave based on active acoustic source signal is proposed in this paper, which includes the followings: the time when the acoustic source signal arrives at the two sensors is measured first; then, the difference of two arriving time arguments is computed, thereby we get the transit time of the acoustic wave between two sensors installed on the two sides of the furnace. Avoiding the restriction on acoustic source signal and background noise, the new method can get the transit time of acoustic wave with higher precision and stronger ability of resisting noise interference.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study of diet and physiological peculiarities of the digestive system of neotropical deer is not well known and the literature shows inconsistencies. To better understand the digestive system of these mammals the difference in the gastro-intestinal transit time of four species of neotropical deer (Mazama americana, Mazama gouazoubira, Mazama nana, Blastocerus dichotomus), kept ill captivity, was evaluated. Four plants (Neonotonia wightii, Morus albans, Medicago sativa, Leucaena leucocephala) were utilized and two variables were measured, mean time of the beginning of the elimination (BE) and mean time of permanence (TP). The results obtained for BE indicated similarity among the deer species, with significant differences between M. gouazoubira (mean = 13.62 hr) and M. Americana (mean = 19.25 hr). For the plants, the BE was faster with N. wightii and L. leucocephala, and slower for M. sativa. The TP results for B. dichotomus showed longer time when compared to the other species, whereas M. gouazoubira had a lower permanence. Overall, N. wightii had the highest retention time in the digestive tract of all the deer species studied. Associated with this observation, N. wightii had the highest quantity of plant fiber of the plants tested. In a similar fashion M. sativa showed the lowest TP in the digestive tract of the deer and had the lowest quantity of acid detergent fiber. The data from this study showed that, within species, the shape of the excretion curve of the plants was similar when the animals consumed N. wightii or M. sativa. Blastocerus dichotomus and M. gouazoubira had the highest and the lowest gastro-intestinal transit time, respectively. This suggests that these species characterize different abilities to digest high fiber food, and consequently, represent the two extremities in the morphophysiological adaptation within the deer species evaluated. This information is vital because it is important to know the digestive physiology to define the diet of captive animals, particularly regarding the quantity and quality of fiber. Zoo Biol 25:47-57, 2006. (C) 2005 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)