999 resultados para EXCHANGE KINETICS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ag+- and Zn2+-exchanged zeolites zeolites and clays have been used as coatings and in composites to confer broad-spectrum antimicrobial properties on a range of technical and biomedical materials. 11 angstrom tobermorite is a bioactive layer lattice ion exchanger whose potential as a carrier for Ag+ and Zn2+ ions in antimicrobial formulations has not yet been explored. In view of this, batch Ag+- and Zn2+-exchange kinetics of two structurally distinct synthetic 11 angstrom tobermorites and their subsequent bactericidal action against Staphylococcus aureus and Pseudomonas aeruginosa are reported. During the exchange reactions, Ag+ ions were found to replace labile interlayer cations; whereas, Zn2+ ions also displaced structural Ca2+ ions from the tobermorite lattice. In spite of these different mechanisms, a simple pseudo-second-order model provided a suitable description of both exchange processes (R-2 >= 0.996). The Ag+- and Zn2+-exchanged tobermorite phases exhibited marked bacteriostatic effects against both bacteria, and accordingly, their potential for use as antimicrobial materials for in situ bone tissue regeneration is discussed. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A sensitive test for kinetic unfolding intermediates in ribonuclease A (EC 3.1.27.5) is performed under conditions where the enzyme unfolds slowly (10 degrees C, pH 8.0, 4.5 M guanidinium chloride). Exchange of peptide NH protons (2H-1H) is used to monitor structural opening of individual hydrogen bonds during unfolding, and kinetic models are developed for hydrogen exchange during the process of protein unfolding. The analysis indicates that the kinetic process of unfolding can be monitored by EX1 exchange (limited by the rate of opening) for ribonuclease A in these conditions. Of the 49 protons whose unfolding/exchange kinetics was measured, 47 have known hydrogen bond acceptor groups. To test whether exchange during unfolding follows the EX2 (base-catalyzed) or the EX1 (uncatalyzed) mechanism, unfolding/exchange was measured both at pH 8.0 and at pH 9.0. A few faster-exchanging protons were found that undergo exchange by both EX1 and EX2 processes, but the 43 slower-exchanging protons at pH 8 undergo exchange only by the EX1 mechanism, and they have closely similar rates. Thus, it is likely that all 49 protons undergo EX1 exchange at the same rate. The results indicate that a single rate-limiting step in unfolding breaks the entire network of peptide hydrogen bonds and causes the overall unfolding of ribonuclease A. The additional exchange observed for some protons that follows the EX2 mechanism probably results from equilibrium unfolding intermediates and will be discussed elsewhere.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The objective of the present study was to compare pulmonary gas exchange kinetics (VO 2 kinetics) and time to exhaustion (Tlim) between trained and untrained individuals during severe exercise performed on a cycle ergometer and treadmill. Eleven untrained males in running (UR) and cycling (UC), nine endurance cyclists (EC), and seven endurance runners (ER) were submitted to the following tests on separate days: (i) incremental test for determination of maximal oxygen uptake (VO 2max) and the intensity associated with the achievement of VO 2max (IVO 2max) on a mechanical braked cycle ergometer (EC and UC) and on a treadmill (ER and UR); (ii) all-out exercise bout performed at IVO 2max to determine the time to exhaustion at IVO 2max (Tlim) and the time constant of oxygen uptake kinetics (τ). The τ was significantly faster in trained group, both in cycling (EC = 28.2 ± 4.7 s; UC = 63.8 ± 25.0 s) and in running (ER = 28.5 ± 8.5 s; UR = 59.3 ± 12.0 s). Tlim of untrained was significantly lower in cycling (EC = 384.4 ± 66.6 s vs. UC; 311.1 ± 105.7 s) and higher in running (ER = 309.2 ± 176.6 s vs. UR = 439.8 ± 104.2 s). We conclude that the VO 2 kinetic response at the onset of severe exercise, carried out at the same relative intensity is sensitive to endurance training, irrespective of the exercise type. The endurance training seems to differently influence Tlim during exercise at IVO 2max in running and cycling. © 2003 Taylor & Francis Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coal seam gas operations produce significant quantities of associated water which often require demineralization. Ion exchange with natural zeolites has been proposed as a possible approach. The interaction of natural zeolites with solutions of sodium chloride and sodium bicarbonate in addition to coal seam gas water is not clear. Hence, we investigated ion exchange kinetics, equilibrium, and column behaviour of an Australian natural zeolite. Kinetic tests suggested that the pseudo first order equation best simulated the data. Intraparticle diffusion was part of the rate limiting step and more than one diffusion process controlled the overall rate of sodium ion uptake. Using a constant mass of zeolite and variable concentration of either sodium chloride or sodium bicarbonate resulted in a convex isotherm which was fitted by a Langmuir model. However, using a variable mass of zeolite and constant concentration of sodium ions revealed that the exchange of sodium ions with the zeolite surface sites was in fact unfavourable. Sodium ion exchange from bicarbonate solutions (10.3 g Na/kg zeolite) was preferred relative to exchange from sodium chloride solutions (6.4 g Na/kg zeolite). The formation of calcium carbonate species was proposed to explain the observed behaviour. Column studies of coal seam gas water showed that natural zeolite had limited ability to reduce the concentration of sodium ions (loading 2.1 g Na/kg zeolite) with rapid breakthrough observed. It was concluded that natural zeolites may not be suitable for the removal of cations from coal seam gas water without improvement of their physical properties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Molecular motors are proteins that convert chemical energy into mechanical work. The viral packaging ATPase P4 is a hexameric molecular motor that translocates RNA into preformed viral capsids. P4 belongs to the ubiquitous class of hexameric helicases. Although its structure is known, the mechanism of RNA translocation remains elusive. Here we present a detailed kinetic study of nucleotide binding, hydrolysis, and product release by P4. We propose a stochastic-sequential cooperative model to describe the coordination of ATP hydrolysis within the hexamer. In this model the apparent cooperativity is a result of hydrolysis stimulation by ATP and RNA binding to neighboring subunits rather than cooperative nucleotide binding. Simultaneous interaction of neighboring subunits with RNA makes the otherwise random hydrolysis sequential and processive. Further, we use hydrogen/deuterium exchange detected by high resolution mass spectrometry to visualize P4 conformational dynamics during the catalytic cycle. Concerted changes of exchange kinetics reveal a cooperative unit that dynamically links ATP binding sites and the central RNA binding channel. The cooperative unit is compatible with the structure-based model in which translocation is effected by conformational changes of a limited protein region. Deuterium labeling also discloses the transition state associated with RNA loading which proceeds via opening of the hexameric ring. Hydrogen/deuterium exchange is further used to delineate the interactions of the P4 hexamer with the viral procapsid. P4 associates with the procapsid via its C-terminal face. The interactions stabilize subunit interfaces within the hexamer. The conformation of the virus-bound hexamer is more stable than the hexamer in solution, which is prone to spontaneous ring openings. We propose that the stabilization within the viral capsid increases the packaging processivity and confers selectivity during RNA loading. Finally, we use single molecule techniques to characterize P4 translocation along RNA. While the P4 hexamer encloses RNA topologically within the central channel, it diffuses randomly along the RNA. In the presence of ATP, unidirectional net movement is discernible in addition to the stochastic motion. The diffusion is hindered by activation energy barriers that depend on the nucleotide binding state. The results suggest that P4 employs an electrostatic clutch instead of cycling through stable, discrete, RNA binding states during translocation. Conformational changes coupled to ATP hydrolysis modify the electrostatic potential inside the central channel, which in turn biases RNA motion in one direction. Implications of the P4 model for other hexameric molecular motors are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O lixiviado gerado em aterro sanitário possui substâncias de difícil degradação e amônia, que dificulta o tratamento biológico. O tratamento do lixiviado gerado em aterros sanitários requer uma série de processos de elevado custo e, outras técnicas de tratamento têm sido investigadas no intuito de reduzir custos e aumentar a eficiência do tratamento. A evaporação do lixiviado é uma técnica que aproveita o gás de aterro como fonte de calor, e é utilizada na redução do volume a tratar; porém as emissões atmosféricas geradas durante essa evaporação indicam a presença de amônia, o que pode causar impactos negativos em torno do aterro. Desta forma, é importante a realização de estudos que aprimorem esta técnica, para que a evaporação torne-se ambientalmente e economicamente viável. A amônia presente em amostras com pH em torno de 8,0 e temperatura em torno de 25C, está na forma de íon amônio, o que favorece ao processo de troca iônica. A troca iônica é um processo que tem sido estudado por muitos pesquisadores e consiste na troca de um ou mais constituintes de uma fase fluida para a superfície de uma fase sólida (resinas poliméricas). Este trabalho apresenta a eficiência de quatro tipos diferentes de resinas poliméricas: Amberlyst 15 Wet, Lewatit VPOC 1800, Dowex Mac-3 e Purolite MN250 na remoção e posterior, recuperação do íon amônio presente nos vapores condensados da evaporação de lixiviados. A princípio foi investigado a quantidade e o momento em que o amônio é lançado durante o processo de evaporação. Em seguida, caracterizaram-se as resinas quanto à eficiência de remoção, o tempo de contato e a quantidade ideal da resina. Estão apresentadas neste estudo as isotermas de adsorção de Langmuir, Freundlich e Temkin em diferentes temperaturas (298-318 K) e as condições ideais do processo. Os resultados apontaram duas resinas com eficiência de remoção, em torno de 40%, para concentrações acima de 1000 mg dm-3 de amônio, utilizando 0,5 g de resina e um tempo de contato de 20 minutos. Diferentes modelos cinéticos foram aplicados: Pseudo-Primeira Ordem, Pseudo-Segunda Ordem, difusão intrapartícula, Elovich e o modelo cinético de difusão externa e os resultados discutidos. Foi possível tratar Através da condensação dos vapores emitidos durante a evaporação do lixiviado, foi possível tratar foi possível obter uma recuperação em torno de 70% do íon amônio contido no vapor condensado proveniente da evaporação do lixiviado.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The potentiometric and AC impedance characteristics of all solid-state sodium-selective electrodes based on planar screen-printed Ag/AgCl electrodes are described. Two solid-state designs have been investigated. The first was based on the deposition of a sodium-selective PVC membrane directly on top of a screen-printed Ag/AgCl electrode, The second design included a NaCl doped hydrogel layer, between the PVC and Ag\AgCl layers. The hydrogel provides a mechanism to relieve any blockage to charge transfer occurring when PVC membranes are used directly on top of Ag/AgCl and also improves adhesion between the two layers. Results suggest the electrodes display Fast ion exchange kinetics, low noise and drift. The performance compares favorably to that of a conventional ion-selective electrode with internal filling solution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

New Findings

What is the central question of this study?Exercise performance is limited during hypoxia by a critical reduction in cerebral and skeletal tissue oxygenation. To what extent an elevation in systemic free radical accumulation contributes to microvascular deoxygenation and the corresponding reduction in maximal aerobic capacity remains unknown.What is the main finding and its importance?We show that altered free radical metabolism is not a limiting factor for exercise performance in hypoxia, providing important insight into the fundamental mechanisms involved in the control of vascular oxygen transport.

Exercise performance in hypoxia may be limited by a critical reduction in cerebral and skeletal tissue oxygenation, although the underlying mechanisms remain unclear. We examined whether increased systemic free radical accumulation during hypoxia would be associated with elevated microvascular deoxygenation and reduced maximal aerobic capacity (). Eleven healthy men were randomly assigned single-blind to an incremental semi-recumbent cycling test to determine  in both normoxia (21% O2) and hypoxia (12% O2) separated by a week. Continuous-wave near-infrared spectroscopy was employed to monitor concentration changes in oxy- and deoxyhaemoglobin in the left vastus lateralis muscle and frontal cerebral cortex. Antecubital venous blood samples were obtained at rest and at  to determine oxidative (ascorbate radical by electron paramagnetic resonance spectroscopy), nitrosative (nitric oxide metabolites by ozone-based chemiluminescence and 3-nitrotyrosine by enzyme-linked immunosorbent assay) and inflammatory stress biomarkers (soluble intercellular/vascular cell adhesion 1 molecules by enzyme-linked immunosorbent assay). Hypoxia was associated with increased cerebral and muscle tissue deoxygenation and lower  (P < 0.05 versus normoxia). Despite an exercise-induced increase in oxidative–nitrosative–inflammatory stress, hypoxia per se did not have an additive effect (P > 0.05 versus normoxia). Consequently, we failed to observe correlations between any metabolic, haemodynamic and cardiorespiratory parameters (P > 0.05). Collectively, these findings suggest that altered free radical metabolism cannot explain the elevated microvascular deoxygenation and corresponding lower  in hypoxia. Further research is required to determine whether free radicals when present in excess do indeed contribute to the premature termination of exercise in hypoxia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O Mercúrio é um dos metais pesados mais tóxicos existentes no meio ambiente, é persistente e caracteriza-se por bioamplificar e bioacumular ao longo da cadeia trófica. A poluição com mercúrio é um problema à escala global devido à combinação de emissões naturais e emissões antropogénicas, o que obriga a políticas ambientais mais restritivas sobre a descarga de metais pesados. Consequentemente o desenvolvimento de novos e eficientes materiais e de novas tecnologias para remover mercúrio de efluentes é necessário e urgente. Neste contexto, alguns materiais microporosos provenientes de duas famílias, titanossilicatos e zirconossilicatos, foram investigados com o objectivo de avaliar a sua capacidade para remover iões Hg2+ de soluções aquosas. De um modo geral, quase todos os materiais estudados apresentaram elevadas percentagens de remoção, confirmando que são bons permutadores iónicos e que têm capacidade para serem utilizados como agentes descontaminantes. O titanossilicato ETS-4 foi o material mais estudado devido à sua elevada eficiência de remoção (>98%), aliada à pequena quantidade de massa necessária para atingir essa elevada percentagem de remoção. Com apenas 4 mg⋅dm-3 de ETS-4 foi possível tratar uma solução com uma concentração igual ao valor máximo admissível para descargas de efluentes em cursos de água (50 μg⋅dm-3) e obter água com qualidade para consumo humano (<1.0 μg⋅dm-3), de acordo com a legislação Portuguesa (DL 236/98). Tal como para outros adsorbentes, a capacidade de remoção de Hg2+ do ETS- 4 depende de várias condições experimentais, tais como o tempo de contacto, a massa, a concentração inicial de mercúrio, o pH e a temperatura. Do ponto de vista industrial as condições óptimas para a aplicação do ETS-4 são bastante atractivas, uma vez que não requerem grandes quantidades de material e o tratamento da solução pode ser feito à temperatura ambiente. A aplicação do ETS-4 torna-se ainda mais interessante no caso de efluentes hospitalares, de processos de electro-deposição com níquel, metalúrgica, extracção de minérios, especialmente ouro, e indústrias de fabrico de cloro e soda cáustica, uma vez que estes efluentes apresentam valores de pH semelhantes ao valor de pH óptimo para a aplicação do ETS-4. A cinética do processo de troca iónica é bem descrita pelo modelo Nernst-Planck, enquanto que os dados de equilíbrio são bem ajustados pelas isotérmicas de Langmuir e de Freundlich. Os parâmetros termodinâmicos, ΔG° and ΔH° indicam que a remoção de Hg2+ pelo ETS-4 é um processo espontâneo e exotérmico. A elevada eficiência do ETS-4 é confirmada pelos valores da capacidade de remoção de outros materiais para os iões Hg2+, descritos na literatura. A utilização de coluna de ETS-4 preparada no nosso laboratório, para a remoção em contínuo de Hg2+ confirma que este material apresenta um grande potencial para ser utilizado no tratamento de águas. ABSTRACT: Mercury is one of the most toxic heavy metals, exhibiting a persistent character in the environment and biota as well as bioamplification and bioaccumulation along the food chain. Natural inputs combined with the global anthropogenic sources make mercury pollution a planetary-scale problem, and strict environmental policies on metal discharges have been enforced. The development of efficient new materials and clean-up technologies for removing mercury from effluents is, thus, timely. In this context, in my study, several microporous materials from two families, titanosilicates and zirconosilicates were investigated in order to assess their Hg2+ sorption capacity and removal efficiency, under different operating conditions. In general, almost all microporous materials studied exhibited high removal efficiencies, confirming that they are good ion exchangers and have potential to be used as Hg2+ decontaminant agents. Titanosilicate ETS-4 was the material most studied here, by its highest removal efficiency (>98%) and lowest mass necessary to attain it. Moreover, according with the Portuguese legislation (DL 236/98) it is possible to attain drinking water quality (i.e. [Hg2+]< 1.0 μg⋅dm-3) by treating a solution with a Hg2+ concentration equal to the maximum value admissible for effluents discharges into water bodies (50 μg⋅dm-3), using only 4 mg⋅dm-3 of ETS-4. Even in the presence of major freshwater cations, ETS-4 removal efficiency remains high. Like for other adsorbents, the sorption capacity of ETS-4 for Hg2+ ions is strongly dependent on the operating conditions, such as contact time, mass, initial Hg2+ concentration and solution pH and, to a lesser extent, temperature. The optimum operating conditions found for ETS-4 are very attractive from the industrial point of view because the application of ETS-4 for the treatment of wastewater and/or industrial effluents will not require larges amounts of adsorbent, neither energy supply for temperature adjustments becoming the removal process economically competitive. These conditions become even more interesting in the case of medical institutions liquid, nickel electroplating process, copper smelter, gold ore tailings and chlor-alkali effluents, since no significant pH adjustments to the effluent are necessary. The ion exchange kinetics of Hg2+ uptake is successfully described by the Nernst-Planck based model, while the ion exchange equilibrium is well fitted by both Langmuir and Freundlich isotherms. Moreover, the feasibility of the removal process was confirmed by the thermodynamic parameters (ΔG° and ΔH°) which indicate that the Hg2+ sorption by ETS-4 is spontaneous and exothermic. The higher efficiency of ETS-4 for Hg2+ ions is corroborate by the values reported in literature for the sorption capacity of other adsorbents for Hg2+ ions. The use of an ETS-4 fixed-bed ion exchange column, manufactured in our laboratory, in the continuous removal of Hg2+ ions from solutions confirms that this titanosilicate has potential to be used in industrial water treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present a new strategy for the label-free electrochemical detection of DNA hybridization for detecting hepatitis C virus based on electrostatic modulation of the ion-exchange kinetics of a polypyrrole film deposited at microelectrodes. Synthetic single-stranded 18-mer HCV genotype-1-specific probe DNA has been immobilized at a 2,5-bis(2-thienyl)-N-(3-phosphoryl-n-alkyl)pyrrole film established by electropolymerization at the previously formed polypyrrole layer. HCV DNA sequences (244-mer) resulting from the reverse transcriptase-linked polymerase chain reaction amplification of the original viral RNA were monitored by affecting the ion-exchange properties of the polypyrrole film. The performance of this miniaturized DNA sensor system was studied in respect to selectivity, sensitivity, and reproducibility. The limit of detection was determined at 1.82 x 10(-21) mol L-1. Control experiments were performed with cDNA from HCV genotypes 2a/c, 2b, and 3 and did not show any unspecific binding. Additionally, the influence of the spacer length of 2,5-bis(2-thienyl)-N-(3-phosphoryl-n-alkyl)pyrrole on the behavior of the DNA sensor was investigated. This biosensing scheme was finally extended to the electrochemical detection of DNA at submicrometer-sized DNA biosensors integrated into bifunctional atomic force scanning electrochemical microscopy probes. The 18-mer DNA target was again monitored by following the ion-exchange properties of the polypyrrole film. Control experiments were performed with 12-base pair mismatched sequences.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A label-free electrochemical detection method for DNA hybridization based on electrostatic modulation of the ion-exchange kinetics of a polypyrrole film deposited at microelectrodes is reported. Synthetic single-stranded 27-mer oligonucleotides (probe) have been immobilized at 2,5-bis(2-thienyl)-N-(3-phosphorylpropyl)pyrrole film formed by electropolymerization on the previously formed polypyrrole layer. The 27- or 18-mer target oligonucleotides were monitored via the electrochemically driven anion exchange of the inner polypyrrole film. The performance of the miniaturized DNA biosensor system was studied in respect to selectivity, sensitivity, reproducibility, and regeneration of the sensor. Control experiments were performed with a noncomplementary target of 27-mer DNA and 12 base-pair mismatched 18-mer sequences, respectively, and did not show any unspecific binding. Under optimized experimental conditions, the label-free electrochemical biosensor enabled the detection limits of 0.16 and 3.5 fmol for the 18- and 2 7-mer DNA strand, respectively. Furthermore, we demonstrate reusability of the electrochemical DNA biosensor after successful recovery of up to 100% of the original signal by regenerating the DNA label-free electrode with 50 mM HCl at room temperature.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Setf-supported asymmetric hollow-fiber membranes of mixed oxygen-ionic and electronic conducting perovskite Ba0.5Sr0.5Co0.8Fe0.2O3-delta (BSCF) were prepared by a combined phase-inversion and sintering technique. The starting inorganic powder was synthesized by combined EDTA-citrate complexing process followed by thermal treatment at 600 degrees C. The powder was dispersed in a polymer solution and then extruded into hollow-fiber precursors through a spinneret. ne fiber precursors were sintered at elevated temperatures to form gastight membranes, which were characterized by SEM and gas permeation tests. Performance of the hollow fibers in air separation was both experimentally and theoretically studied at various conditions. The results reveal that the oxygen permeation process was controlled by the slow oxygen surface exchange kinetics under the investigated conditions. The porous inner surface of the prepared perovskite hollow-fiber membranes considerably favored the oxygen permeation. The maximum oxygen flux measured was 0.031 mol-m(-2).s(-1) at 950 degrees C with the sweep gas flow rate of 0.522 mol(.)m(-2).s(-1). To improve the oxygen flux of BSCF perovskite membranes, future work should be focused on surface modification rather than reduction of the membrane thickness. (c) 2006 American Institute of Chemical Engineers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.